← All vessels
MSC ISABELLE
MSC ISABELLE is a 1985 freight ship. The Coast Guard has recorded 18 inspections since 1986, most recently in April 2003, along with 26 deficiencies and 1 operational control.
Records from 1986 to 2003. Most recent: operational control imposed, 18 April 2003.
- Built
- 1985
- Last inspected
- 18 April 2003
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 26 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8414740 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
PGWB
274733
Flag
PANAMA
—
Maury page id
psix-274733
Inspections, by type
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it9536 - Dead Weight, Ton
5974 - Regulatory (Subpart C or D), Gross Ton
3644 - Regulatory (Subpart C or D), Net Ton
5974 - Regulatory (Subpart C or D), Gross Ton
3644 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 18
18 April 2003
Deficiency Check · Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1776239
22 December 2002
Ballast Water Examination · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1722255
30 August 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 293280
7 September 1999
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 432351
23 July 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 418036
12 March 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 401492
28 July 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 393705
31 May 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 391719
1 June 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 499954
30 October 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 503669
18 June 1992
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 77945
19 March 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 648166
6 March 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 349337
2 March 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 500720
20 July 1991
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 649105
16 May 1991
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 343818
6 July 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 324289
21 October 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 312140
Deficiency record · 26
Engineering › Diesel Engine (propulsion-direct drive)
Issued 18 April 2003
Resolved
Propulsion main engine rocker arm connection O rings are leaking excessively (crew has installed rags to absorb leaks.)
Engineering › Generator (propulsion/auxiliary-electric)
Issued 18 April 2003
Resolved
No. 2 cylinder on No. 2 auxiliary generator high pressure fuel oil injection line is leaking excessively. Do not operate until repaired to the satisfaction of the classification society.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 18 April 2003
Resolved
Propulsion and auxiliary machinery are covered with oil.
Electrical › Electrical Distribution System (emergency)
Issued 18 April 2003
Resolved
There is a dead ground on the 220 volts emergency electrical distribution system. LEGACY COMPONENT DESC: Ground Detection
Pollution Prevention/Response › Prevention Equipment
Issued 18 April 2003
Resolved
Oily water separator piping system has been altered from original design (drainage piping has rubber hose installed to drain water to the bilges vice bilge tank.) LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Engineering
Issued 18 April 2003
Resolved
Oily rags, combustibles and hazardous materials were found throughout machinery space.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 18 April 2003
Resolved
Propulsion main engine injection cooler gasket is leaking excessively.
LEGACY COMPONENT DESC: Injector (fuel injection)
Engineering
Issued 18 April 2003
Resolved
Engine room sludge pump discharge piping has a patch installed.
Electrical › Electric Supply System (service)
Issued 18 April 2003
Resolved
Lube oil transfer pump has improperly wired switch.
Electrical › Electrical Distribution System (service)
Issued 18 April 2003
Resolved
Accommodation ladder winch remote switch is improperly wired in Tally office. LEGACY COMPONENT DESC: Switch
Fire Fighting › International Shore Connection
Issued 22 December 2002
Resolved
Provide gasket and washers for the international shore connection. LEGACY COMPONENT DESC: Gasket
Electrical › Electrical Distribution System (service)
Issued 22 December 2002
Resolved
Secure live circuits in the Talley office and the shore connection compartment. LEGACY COMPONENT DESC: Wiring
Accommodation/Occupational Safety › Occupational Safety
Issued 22 December 2002
Resolved
Remove items from electrical box in Talley office.
Fire Fighting › Combustible Materials
Issued 22 December 2002
Resolved
Remove flammables / combustibles from top shelf in paint locker (port side). LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Engineering › Fuel Oil Storage/Transfer System
Issued 22 December 2002
Resolved
Install flame screens in all combustible vents on main deck. LEGACY COMPONENT DESC: Ventilation
Fire Fighting › Combustible Materials
Issued 22 December 2002
Resolved
Remove all combustible materials from forecastle compartment.
Pollution Prevention/Response › Prevention Equipment
Issued 22 December 2002
Resolved
Prove proper operation of oily water separator upon arrival to next US port. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Navigation
Issued 12 March 1997
Resolved
NOAA chart 11370 was not corrected through the most current correction Notice to Mariners 5/97. The chart was only corrected to 3/96. No foreign equivalant was on board.
Fire Fighting
Issued 31 May 1996
Resolved
PRIOR TO DEPARTING NEXT US PORT, MAKE PERMANENT REPAIRS TO HOLED FIREMAIN AND PROVIDE CLASS ACCEPTANCE OF REPAIRS.
Lifesaving
Issued 31 May 1996
Resolved
PRIOR TO NEXT US PORT, PAINT VESSEL NAME ON STARBOARD SIDE, 01 DECK LIFERING.
Electrical
Issued 31 May 1996
Resolved
PRIOR TO DEPARTING NEXT US PORT, REPLACE MISSING LIGHT COVERS THROUGHOUT VESSEL.
Lifesaving
Issued 31 May 1996
Resolved
PRIOR TO DEPARTURE, REPAIR/REPLACE LIFELIGHT ON STARBOARD SIDE 01 DECK.
Engineering
Issued 31 May 1996
Resolved
PRIOR TO BUNKERING IN US WATERS, REPLACE MISSING GASKET AND BOLTS IN BUNKERSTATIONS PORT AND STARBOARD.
Unknown
Issued 6 March 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation
Issued 16 May 1991
Resolved
Vsl did not have a dangerous cargo manifest. Vsl was carrying 20 tons of EXPA explosives in a freight container._x001C_ _x001C_ _x001C_
Navigation
Issued 21 October 1986
Resolved
VESSEL CONDUCTED THE REQUIRED NAVIGATIONAL TESTS, BUT NOT WITHIN 12 HOURS PRIOR TO ENTRY.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.