MAURY USCG vessel records Sign in
← All vessels

MSC ISABELLE

MSC ISABELLE is a 1985 freight ship. The Coast Guard has recorded 18 inspections since 1986, most recently in April 2003, along with 26 deficiencies and 1 operational control.

Records from 1986 to 2003. Most recent: operational control imposed, 18 April 2003.

Built
1985
Last inspected
18 April 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8414740 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
274733
Flag
PANAMA
—
Maury page id
psix-274733

Inspections, by type

…with no type recorded16
Years with a record 13 calendar years (1986–2003)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it9536 - Dead Weight, Ton
5974 - Regulatory (Subpart C or D), Gross Ton
3644 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 18

18 April 2003 Deficiency Check · Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1776239
22 December 2002 Ballast Water Examination · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1722255
30 August 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 293280
7 September 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 432351
23 July 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 418036
12 March 1997 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 401492
28 July 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 393705
31 May 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 391719
1 June 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 499954
30 October 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 503669
18 June 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 77945
19 March 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 648166
6 March 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 349337
2 March 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 500720
20 July 1991 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 649105
16 May 1991 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 343818
6 July 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 324289
21 October 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 312140

Deficiency record · 26

Engineering › Diesel Engine (propulsion-direct drive)
Issued 18 April 2003 Resolved
Propulsion main engine rocker arm connection O rings are leaking excessively (crew has installed rags to absorb leaks.)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 20 April 2003
Resolution: The "O" rings were renewed and excess has been wiped up.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 18 April 2003 Resolved
No. 2 cylinder on No. 2 auxiliary generator high pressure fuel oil injection line is leaking excessively. Do not operate until repaired to the satisfaction of the classification society.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 20 April 2003
Resolution: Overhauled the injector.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 18 April 2003 Resolved
Propulsion and auxiliary machinery are covered with oil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 20 April 2003
Resolution: Cleaned oil from engine.
Electrical › Electrical Distribution System (emergency)
Issued 18 April 2003 Resolved
There is a dead ground on the 220 volts emergency electrical distribution system. LEGACY COMPONENT DESC: Ground Detection
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 18 April 2003
Resolved 20 April 2003
Resolution: Renewed socket/plug of distribution system.
Pollution Prevention/Response › Prevention Equipment
Issued 18 April 2003 Resolved
Oily water separator piping system has been altered from original design (drainage piping has rubber hose installed to drain water to the bilges vice bilge tank.) LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 20 April 2003
Resolution: Rubber hose has been replaced with the original piping.
Engineering
Issued 18 April 2003 Resolved
Oily rags, combustibles and hazardous materials were found throughout machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 20 April 2003
Resolution: Rags, combustables, and hazerdous materials have been removed from machinerey spaces.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 18 April 2003 Resolved
Propulsion main engine injection cooler gasket is leaking excessively. LEGACY COMPONENT DESC: Injector (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2003
Resolved 20 April 2003
Resolution: Gasket has been renewed.
Engineering
Issued 18 April 2003 Resolved
Engine room sludge pump discharge piping has a patch installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 20 April 2003
Resolution: Piping has been renewed.
Electrical › Electric Supply System (service)
Issued 18 April 2003 Resolved
Lube oil transfer pump has improperly wired switch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 20 April 2003
Resolution: Wiring has been renewed.
Electrical › Electrical Distribution System (service)
Issued 18 April 2003 Resolved
Accommodation ladder winch remote switch is improperly wired in Tally office. LEGACY COMPONENT DESC: Switch
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 20 April 2003
Resolution: Switch connection renewed.
Fire Fighting › International Shore Connection
Issued 22 December 2002 Resolved
Provide gasket and washers for the international shore connection. LEGACY COMPONENT DESC: Gasket
Action required: 15 - Rectify deficiencies by next port
Resolved 18 May 2003
Resolution: Boarding team witnessed satisfactory repairs.
Electrical › Electrical Distribution System (service)
Issued 22 December 2002 Resolved
Secure live circuits in the Talley office and the shore connection compartment. LEGACY COMPONENT DESC: Wiring
Action required: 15 - Rectify deficiencies by next port
Resolved 18 April 2003
Resolution: Reissued deficiency under NEWMS activity number 1776239.
Accommodation/Occupational Safety › Occupational Safety
Issued 22 December 2002 Resolved
Remove items from electrical box in Talley office.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 April 2003
Resolution: Boarding team witnessed satisfactory repairs.
Fire Fighting › Combustible Materials
Issued 22 December 2002 Resolved
Remove flammables / combustibles from top shelf in paint locker (port side). LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Action required: 15 - Rectify deficiencies by next port
Resolved 18 April 2003
Resolution: Boarding team witnessed satisfactory repairs.
Engineering › Fuel Oil Storage/Transfer System
Issued 22 December 2002 Resolved
Install flame screens in all combustible vents on main deck. LEGACY COMPONENT DESC: Ventilation
Action required: 15 - Rectify deficiencies by next port
Resolved 18 April 2003
Resolution: Boarding team witnessed satisfactory repairs.
Fire Fighting › Combustible Materials
Issued 22 December 2002 Resolved
Remove all combustible materials from forecastle compartment.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 April 2003
Resolution: Boarding team witnessed satisfactory repairs.
Pollution Prevention/Response › Prevention Equipment
Issued 22 December 2002 Resolved
Prove proper operation of oily water separator upon arrival to next US port. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Resolved 18 April 2003
Resolution: Reissued deficiency under NEWMS activity number 1776239.
Navigation
Issued 12 March 1997 Resolved
NOAA chart 11370 was not corrected through the most current correction Notice to Mariners 5/97. The chart was only corrected to 3/96. No foreign equivalant was on board.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Fire Fighting
Issued 31 May 1996 Resolved
PRIOR TO DEPARTING NEXT US PORT, MAKE PERMANENT REPAIRS TO HOLED FIREMAIN AND PROVIDE CLASS ACCEPTANCE OF REPAIRS.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Lifesaving
Issued 31 May 1996 Resolved
PRIOR TO NEXT US PORT, PAINT VESSEL NAME ON STARBOARD SIDE, 01 DECK LIFERING.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Electrical
Issued 31 May 1996 Resolved
PRIOR TO DEPARTING NEXT US PORT, REPLACE MISSING LIGHT COVERS THROUGHOUT VESSEL.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Lifesaving
Issued 31 May 1996 Resolved
PRIOR TO DEPARTURE, REPAIR/REPLACE LIFELIGHT ON STARBOARD SIDE 01 DECK.
Condition: Unknown
Due 1 June 1996
Resolved 5 June 1996
Engineering
Issued 31 May 1996 Resolved
PRIOR TO BUNKERING IN US WATERS, REPLACE MISSING GASKET AND BOLTS IN BUNKERSTATIONS PORT AND STARBOARD.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Unknown
Issued 6 March 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995
Documentation
Issued 16 May 1991 Resolved
Vsl did not have a dangerous cargo manifest. Vsl was carrying 20 tons of EXPA explosives in a freight container._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 July 1991
Resolved 20 July 1991
Navigation
Issued 21 October 1986 Resolved
VESSEL CONDUCTED THE REQUIRED NAVIGATIONAL TESTS, BUT NOT WITHIN 12 HOURS PRIOR TO ENTRY.
Condition: Unknown
Due 21 October 1986
Resolved 21 October 1986

Ownership record