MAURY USCG vessel records Sign in
← All vessels

RED WING

RED WING is a 1976 tank ship. The Coast Guard has recorded 32 inspections since 1986, most recently in June 2005, along with 24 deficiencies and 1 operational control.

Records from 1986 to 2005. Most recent: inspection, 23 June 2005.

Built
1976
Last inspected
23 June 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7377256 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
274765
Flag
NORWAY
—
Maury page id
psix-274765

Inspections, by type

…with no type recorded22
Years with a record 11 calendar years (1986–2005)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it141179 - Dead Weight, Ton
72991 - Regulatory (Subpart C or D), Gross Ton
50021 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

23 June 2005 Administrative Inspection
Administrative · Activities Europe · Activity 2399884
7 October 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 433563
25 February 1999 In-Service Inspection
Physical examination · Activities Europe · Activity 426045
7 October 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 675030
12 September 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 199516
10 September 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 395177
5 February 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 458637
17 July 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 470920
1 November 1993 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1146424
30 October 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 510949
17 July 1993 Deficiency Check · Certificate of Compliance
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1158002
18 May 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 675028
4 May 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436755
5 March 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 459126
13 August 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 675029
15 July 1992 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1256870
12 July 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 153751
12 July 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 488944
19 March 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 675027
22 January 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 524471
7 April 1991 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1219623
21 November 1990 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1219201
17 April 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 336630
1 March 1990 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1233447
20 February 1989 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1196638
8 January 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 327589
17 October 1988 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 525649
27 July 1988 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 324634
21 February 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 321478
21 February 1988 MARPOL Annex II Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1330372
28 October 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 312400
28 October 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1013548

Deficiency record · 24

Construction/Loadline
Issued 25 February 1999 Resolved
Paint vessel's name, loadline and draft marks in contrasting colors. Complete prior to entry in U.S waters.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Lifesaving
Issued 25 February 1999 Resolved
Repair wasted rudder fittings on both lifeboats, and replace missing skate on port lifeboat. Complete prior to entry in U.S. waters.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Lifesaving
Issued 25 February 1999 Resolved
Renew wasted/frozen bails to both lifeboat fall hooks. Complete prior to entry in U.S. waters.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Unknown
Issued 25 February 1999 Resolved
Provide oil spill equipment as per 33 CFR 155.205. Complete prior to entry in U.S. waters.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Deck/Cargo › Ballast › CBT
Issued 25 February 1999 Resolved
Repair excessive leaks to the no. 4 cargo pump. Complete prior to entry in U.S. waters.
Condition: Unknown
Due 2 March 1999
Resolved 18 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Navigation
Issued 25 February 1999 Resolved
Prove proper operation of the gyro repeater in the steering room. Complete prior to entry in U.S. waters.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Lifesaving
Issued 25 February 1999 Resolved
Replace expired life jacket/exposure suit lights. Complete prior to entry in U.S. waters.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Documentation
Issued 25 February 1999 Resolved
Update/review SOPEP. Phone numbers incorrect. Complete prior to entry in U.S. waters.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Deck/Cargo › Ballast › Dedicated Clean Ballast Tanks
Issued 25 February 1999 Resolved
Submit annual user fees to Coast Guard Inspections Atlanta Georgia within 30 days.
Condition: Unknown
Due 2 March 1999
Resolved 18 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Lifesaving
Issued 10 September 1996 Resolved
The quick release smoke/light signals on both bridge wing need replacement,bodies cracked in numerous areas. solas ch III
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Documentation
Issued 17 July 1993 Resolved
Prior to return to U.S. waters provide a copy of the letter of receipt fromthe U.S. Coast Guard for the Vessel Response Plan, verifying that it was submitted for approval.
Condition: Unknown
Due 23 August 1993
Resolved 23 August 1993
Deck/Cargo
Issued 17 July 1993 Resolved
Prior to return to U.S. waters, make permanent repairs to the deck water seal where holed and provide a copy of the class society report accepting the repairs.
Condition: Unknown
Due 17 July 1993
Resolved 17 July 1993
Fire Fighting
Issued 17 July 1993 Resolved
Prior to return to U.S. waters, provide a copy of the foam analysis report to the cognizant OCMI.
Condition: Unknown
Due 17 July 1993
Resolved 17 July 1993
Deck/Cargo
Issued 4 May 1993 Resolved
THREE HOLES IN IGS LINES. (1) MAIN DECK, PORT AFT, 1" HOLE (2) MAIN SHUT OFF VALVE 1" HOLE; IN FRONT OF PILOT HOUSE. (3) LINE TO #4S 2" HOLE
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Deck/Cargo
Issued 15 July 1992 Resolved
PRIOR TO THE RETURN OF U.S. WATERS PROVIDE EVIDENCE OF SATISFACTORY HYDROSTATIC CARGO LINE TESTS AS REQUIRED BY 46CFR35.35-70.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Construction/Loadline
Issued 15 July 1992 Resolved
PRIOR TO THE RETURN OF U.S. WATERS, A DETERMINATION OF THE INTERMITTENT POLLUTION SOURCE SHALL BE MADE. PERMANENT REPAIRS SHALL BE EFFECTED TO THESATISFACTION OF VSL'S CLASSIFICATION SOCIETY, SO AS TO PREVENT SUCH A REOCCURRENCE.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Deck/Cargo
Issued 15 July 1992 Resolved
PRIOR TO THE RETURN OF U.S. WATERS MAKE PERMANENT REPAIRS TO TWO (2) SOFT PATCHES THAT ARE FORWARED OF THE DECK ISOLATION VALVE ON THE INERT GAS MAINLINE.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Engineering
Issued 15 July 1992 Resolved
PRIOR TO THE RETURN OF U.S. WATERS PROVIDE EVIDENCE OF A SATISFACTORY HYDROSTATIC BUNKER LINE TEST AS REQUIRED BY 46CFR35.35-70.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Construction/Loadline
Issued 21 November 1990 Resolved
PRIOR TO RETURING TO U.S. WATERS VESSEL MUST REPAIR STORM DAMAGE LOCATED IN FOREPEAKE AND OTHER AREAS TO THE SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 21 November 1990
Resolved 21 November 1990
Fire Fighting
Issued 1 March 1990 Resolved
REPAIR WELD IN THE FLANG TO THE AFTERMOST FOAM FIGHTING MONITOR. DEFICIENCY MUST BE COMPLETED PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 1 March 1990
Resolved 1 March 1990
Navigation
Issued 20 February 1989 Resolved
VESSEL MUST HAVE ON BOARD PRIOR TO DEPARTURE OF THE PORT OF PHILADELPHIA A US COAST PILOT VOL.3 AND COAST GUARD LIGHT LIST VOL.2
Condition: Unknown
Due 20 February 1989
Resolved 20 February 1989
Navigation
Issued 20 February 1989 Resolved
VESSEL MUST MAKE REPAIRS TO THE ARPA SYSTEM PRIOR TO DEPARTURE OF THE PORT OF PHILADELPHIA.
Condition: Unknown
Due 20 February 1989
Resolved 20 February 1989
Fire Fighting
Issued 21 February 1988 Resolved
PROVIDE A FIXED FIRE FIGHTING SYSTEM IN THE FORWARD PAINT LOCKER, OR REMOVE ALL PAINTS AND STORE IN AFT STORAGE ROOM.
Condition: Unknown
Due 21 February 1988
Resolved 21 February 1988
Documentation
Issued 21 February 1988 Resolved
PROVIDE PROOF OF ANNUAL MARPOL SURVEY ON BOARD.
Condition: Unknown
Due 21 February 1988
Resolved 21 February 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.