Documentation record
Registered dimensions (L × B × D)64.8 ft × 19.0 ft × 8.0 ft
Registered tonnagegross 65 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBONNER YACHTS · WETUMPKA, AL, UNITED STATES · built 1986
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Simplified, Gross Ton
52 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
27 February 2026
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8317721
20 November 2025
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8271872
4 April 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8097628
12 April 2024
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7894329
4 January 2024
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7882489
27 February 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7642763
2 May 2022
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7442120
21 March 2022
Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7417307
21 September 2021
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7317864
9 March 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7152612
7 May 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6949947
26 February 2020
Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6916327
5 November 2019
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6850217
1 October 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814643
25 February 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6631862
23 July 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6489684
3 April 2018
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6384085
30 January 2018
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6346431
2 May 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6137944
8 March 2017
Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6101139
16 February 2016
Hull Examination · COI Inspection · Examination of Repairs · Internal Structural Exam · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5815986
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 April 2024
Resolved
An interconnected detection and alarm system must be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405 (c) to be protected by the interconnected detection and alarm system. Install an interconnected fire detection system as required within 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 April 2024
Resolved 30 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 April 2024
Resolved
a vessel must have one ring life buoy with a floating waterlight. vessel was found with a ring life buoy waterlight incapable of being illuminated due to water intrusion. Replace the light.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2024
Resolved 30 April 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 May 2022
Resolved
The rules concerning lights shall be complied with from sunrise to sunset.
-Daylight operations only.
Action required: 705 - Other - as specified
Resolved 24 June 2022
Resolution: Received photos. Uploaded to docs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 22 September 2021
Resolved
A hatch exposed to the weather must be watertight. The fore peak hatch would not completely dog and found water in forward compartment. Hatch must be adjusted to ensure it is watertight to prevent water in space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2021
Resolved 5 October 2021
Resolution: Owner tighted dogs on forward hatch.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 March 2021
Resolved
Deck rails must be designed and constructed to withstand a point load of 200lbs. The handrails were found with a crack in the fiberglass supports which effect the strength of the hand rails. Repair cracked fiberglass to the satisfaction of attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 2 April 2021
Resolution: Photo was sent with repairs to FRP. Def cleared.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 9 March 2021
Resolved
Passenger accomodations must be arranged and equiped to provide for the safety of the passengers and crew. Two egress door windows were broken during Hurricane Sally. Replace both broken windows.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 7 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 9 March 2021
Resolved
water tight hatches must be maintained in operating condition. T-handle collar was found missing or broken on multiple hatches. Repair or replace T-handle collars.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 2 April 2021
Resolution: collars were replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 9 March 2021
Resolved
Electrical equipment must be installed and maintained to protect passengers and crew from electrial hazards. Dead end wires wer noted on the bow and must be removed or light that was removed replaced.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 2 April 2021
Resolution: Lights were replaced and properly connected to electrical wires.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 March 2021
Resolved
Water heater relief valve must be rated at more than 100psi or the heater must be approved under UL 174 UL 1453.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 7 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 9 March 2021
Resolved
Survival craft must be of good quality and maintained. The float was found with torn storage net. Net to be repaired or replaced to the satisfaction of attending marine inspector. Net was temporarily repaired.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 2 April 2021
Resolution: life float net was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2019
Resolved
Receptacle outlets operating at 100 V or more shall provide a grounding conductor. Noted all outlets have an open ground. Rewire IAW 46 CFR 183 (New T Applicable)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2019
Resolved 13 November 2019
Resolution: All electrical outlets were either repaired or rewired to the satisfaction of the Coast Guard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 1 October 2019
Resolved
Noted lazarette "T" handle sheared off. Replace and repair as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 17 October 2019
Resolution: Lazarette "T" Handle replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 1 October 2019
Resolved
Noted ball valve handle for port main sea chest missing locking nut. Replace as necessary.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2019
Resolution: ball valve handle reattached with locking nut
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 23 April 2018
Resolved
Renew expired FCC Safety Radiotelephony Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 23 July 2018
Resolution: Renewed FCC radiotelephone certificate.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 April 2018
Resolved
Provide proof of DAPI enrollment and supervisor training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 23 July 2018
Resolution: Master provided proof of DAPI enrollment and supervisor training.
Engineering › Fuel Oil Service System › Valve
Issued 23 April 2018
Resolved
Emergency fuel shutoff valve not properly working. Fix so that valves fully close.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 23 July 2018
Resolution: Inspected emergency fuel shutoff valve; found working properly.
Operations/Management › Drills/Instruction › Fire
Issued 23 April 2018
Resolved
Get underway to conduct drills in the presence of a USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 23 July 2018
Resolution: Got underway and conducted man overboard, fire and abandoned ship drills.
Engineering › Bilge Water Management System › Piping
Issued 26 April 2017
Resolved
Replace PVC piping in bilge system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 2 May 2017
Resolution: Piping was replaced with rigid non-metallic hose.
Documentation › Certificates/Documents › FCC SSL
Issued 26 April 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 2 May 2017
Resolution: Radio station licence renewed and on board
Engineering › Steering Gear System › Linkage
Issued 26 April 2017
Resolved
Repair cracked weld on stbd rudder post.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 2 May 2017
Resolution: Satisfactory weld was laid on strbd post
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 April 2017
Resolved
Install running lights properly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 2 May 2017
Resolution: Nav lights were satifactorily installed
Stability › Watertight Integrity › General
Issued 26 April 2017
Resolved
Deck penetration under fish box needs to be properly sealed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 2 May 2017
Resolution: Deck penetration was properly sealed