MAURY USCG vessel records Sign in
← All vessels

ASSERTIVE

ASSERTIVE is a 1986 unclassified. The Coast Guard has recorded 64 inspections since 1986, most recently in June 2021, along with 72 deficiencies.

Records from 1986 to 2021. Most recent: inspection, 7 June 2021.

Built
1986
Last inspected
7 June 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8835504 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
274959
Flag
UNITED STATES
—
Maury page id
psix-274959

Inspections, by type

…with no type recorded21
Years with a record 17 calendar years (1986–2021)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it1072 - Regulatory (Subpart C or D), Net Ton
970 - Dead Weight, Ton
618 - Convention (Subpart B), Net Ton
2535 - Displacement, Ton
1576 - Regulatory (Subpart C or D), Gross Ton
2060 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 64

7 June 2021 Exemption
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7215710
9 September 2002 Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1670988
19 October 2001 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1074945
20 September 2001 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1468671
29 August 2001 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 170271
21 August 2001 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1403467
1 October 1999 COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1365397
12 February 1999 Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1472923
19 October 1998 Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1364979
17 June 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 225360
17 December 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 781386
19 November 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1425993
17 October 1997 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1111789
6 October 1997 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 775521
5 September 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1122129
18 May 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 65921
22 April 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1406095
4 November 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 99646
25 October 1996 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1166729
15 October 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 41818
25 September 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 829863
3 September 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1428691
26 August 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1086739
18 July 1996 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 229768
30 May 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 938581
8 May 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355788
3 May 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1443698
2 May 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1081998
4 October 1995 Deficiency Check · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1383069
20 March 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 871443
2 February 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 132145
12 August 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356773
26 July 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 147413
28 April 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356621
10 March 1994 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 855289
10 March 1994 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1382707
14 December 1993 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1163144
13 December 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 153999
3 September 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 60451
28 July 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 41751
11 May 1993 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1135438
29 April 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 159544
20 October 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1246446
20 August 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1254777
24 July 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 958921
8 October 1991 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1245677
3 September 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 939965
19 July 1991 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 939273
11 January 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 913194
16 October 1990 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1231688
26 August 1990 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 930500
23 August 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 929302
11 June 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 911838
27 November 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 927472
5 September 1989 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 891310
23 February 1989 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1209063
10 August 1988 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 896885
22 July 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1029731
15 July 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1021309
14 July 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1019348
3 April 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1330412
20 March 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1326348
19 November 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1018554
8 September 1986 Initial Certification · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1323355

Deficiency record · 72

Engineering › Compressed Air System (start air)
Issued 9 September 2002 Resolved
Prior to getting underway but not later than September 25, 2002 demonstrate satisfactory operation of number two starting air tank (PV) safety relief valve. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2002
Resolved 24 September 2002
Resolution: Cleared with Fax from Master.
Electrical › Electric Generation Source (service)
Issued 9 September 2002 Resolved
Prior to getting underway but not later than September 25, 2002 make repairs and demonstrate satisfactory operation of overspeed trip for number one diesel engine. LEGACY COMPONENT DESC: Generator
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2002
Resolved 24 September 2002
Resolution: Cleared with Fax from Master.
Engineering › Sea-water System (primary cooling)
Issued 9 September 2002 Resolved
Prior to getting underway but no later than September 25, 2002 make repairs to remote valve operation for aft port asw sea chest valve and demonstrate satisfactory operation of the same. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2002
Resolved 24 September 2002
Resolution: Cleared with Fax from Master.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 9 September 2002 Resolved
Prior to getting underway but no later than September 25, 2002 make satisfactory permanent repairs to sewage overboard discharge pipe to the satisfaction of the attending marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2002
Resolved 24 September 2002
Resolution: Cleared with Fax from Master.
Deck/Cargo › Vapor Control Systems
Issued 9 September 2002 Resolved
Cleas all flame screens on fuel oil vents prior to getting underway but no later than September 25, 2002. LEGACY COMPONENT DESC: Flame Screens
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2002
Resolved 24 September 2002
Resolution: Cleared with Fax from Master.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 9 September 2002 Resolved
Provide copy of sewage discharge policy not later than September 25, 2002.
Condition: Unknown
Due 25 September 2002
Resolved 24 September 2002
Resolution: Cleared with Fax from Master.
Deck/Cargo
Issued 20 September 2001 Resolved
Prove proper operation of starboard anchor winch brake.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Lifesaving
Issued 20 September 2001 Resolved
Provide proper instructions for life raft launching.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Fire Fighting
Issued 20 September 2001 Resolved
Repair port and starboard ventilation closure gaskets to steering room.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Navigation
Issued 20 September 2001 Resolved
Provide magnetic compass.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Accommodation/Occupational Safety
Issued 20 September 2001 Resolved
Adjust dogs and prove proper operation of escape scuttle from steering room.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Lifesaving
Issued 20 September 2001 Resolved
Provide embarkation ladders of sufficient length.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Lifesaving
Issued 20 September 2001 Resolved
Load test life raft davits.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Fire Fighting
Issued 20 September 2001 Resolved
Provide International Shore Connection.
Condition: Unknown
Due 20 September 2001
Resolved 20 September 2001
Accommodation/Occupational Safety
Issued 19 October 1998 Resolved
Replace window in aft steering station.
Condition: Unknown
Due 19 October 1998
Resolved 19 October 1998
Accommodation/Occupational Safety
Issued 19 October 1998 Resolved
Replace broken glass on both sewage discharge pumps gauges and recalibrate them.
Condition: Unknown
Due 19 October 1998
Resolved 19 October 1998
Construction/Loadline
Issued 19 October 1998 Resolved
Remove unauthorized piping modification to oily bilge piping system, centerline, aft blkhead of generator room.
Condition: Unknown
Due 19 October 1998
Resolved 19 October 1998
Engineering
Issued 19 October 1998 Resolved
Provide data plates for all pressure vessels in accordance with 46 CFR 54.10-20
Condition: Unknown
Due 19 October 1998
Resolved 19 October 1998
Engineering
Issued 19 October 1998 Resolved
Replace or repair all 4 spring loaded ball valves in the generator emergency manual shutdown system.
Condition: Unknown
Due 19 October 1998
Resolved 19 October 1998
Engineering
Issued 19 October 1998 Resolved
Repair or replace oily water seperator system.
Condition: Unknown
Due 19 October 1998
Resolved 19 October 1998
Lifesaving
Issued 19 October 1998 Resolved
Repair or replace fuel gauge for rescue boat.
Condition: Unknown
Due 19 October 1998
Resolved 19 October 1998
Engineering
Issued 19 November 1997 Resolved
Replace single 20X20 mesh screen with two 20X20 or one 30X30 screens on allfuel and oil vents.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Electrical
Issued 5 September 1997 Resolved
Until automation is repaired and fully functional, vessel must sail with one additional licensed engineer. Engineroom must be manned by a licensed engineer at all times.
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Lifesaving
Issued 22 April 1997 Resolved
CONDUCT WEIGHT TESTS ON BOTH LIFERAFT DAVITS IN THE PRESENCE OF A CG INSPECTOR AFTER THE FALLS HAVE BEEN RENEWED.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Engineering
Issued 22 April 1997 Resolved
Replace and renew cracked and deteriorated Fuel Oil supply and return flexible hoses for all four SSDG's.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 22 April 1997 Resolved
Renew cracked/holed ball checks for both potable water tank vents and install screen for the main tank vent.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Lifesaving
Issued 22 April 1997 Resolved
REPLACE (3) MISSING HANDHELD VHF PORTABLE RADIOS.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Engineering
Issued 22 April 1997 Resolved
Prove proper operation of the machinery space Oily Water Separator in the presence of a CG Marine Inspector.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Fire Fighting
Issued 22 April 1997 Resolved
Extend the port and starboard stack vent damper shutdown devices to a remote position outside of the newly installed stack enclosures on the 01 deck and properly label each damper shutdown device.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Fire Fighting
Issued 22 April 1997 Resolved
Make repairs to, provide an inspection cover for, and prove proper operation of the E/R starboard supply vent damper on the 01 deck.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Fire Fighting
Issued 22 April 1997 Resolved
Remove "STACK DAMPER" placards/labels for the port and starboard E/R supplyvent dampers.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Lifesaving
Issued 22 April 1997 Resolved
REPLACE TWO EMBARKATION LADDERS.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Fire Fighting
Issued 22 April 1997 Resolved
Repair and prove proper operation of the broken/detached vent louver for the starboard vent stack damper on the 01 deck.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Fire Fighting
Issued 22 April 1997 Resolved
DEMONSTRATE THAT THE HALON PRESSURE SWITCHES SHUTDOWN THE #3 AND #4 GENERATORS.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Engineering
Issued 22 April 1997 Resolved
Prove proper operation of #4SSDG air damper overspeed shutdown device.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Lifesaving
Issued 22 April 1997 Resolved
RENEW LIFERAFT FALLS ON BOTH LIFERAFT DAVITS.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Fire Fighting
Issued 3 May 1996 Resolved
Demonstrate proper operation of all the smoke detectors in the propulsion motor space and aft steering room. The indicator light in the detector_x001C_ will light when activated.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Electrical
Issued 3 May 1996 Resolved
Install an audible alarm that sounds upon low lube oil pressure for the Emergency Diesel Generator.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Fire Fighting
Issued 3 May 1996 Resolved
Install and demonstrate proper operation of the required smoke detector in the main control room.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Electrical
Issued 3 May 1996 Resolved
Install ground detection systems for all the secondary sides of all power and lighting transformer banks not equipped with ground detection.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Lifesaving
Issued 3 May 1996 Resolved
Recharge all EEBA air bottles throughout the machinery spaces to proper levels.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Engineering
Issued 3 May 1996 Resolved
Install high temperature alarms for the Propulsion SCR's that activates prior to high temperature shutdown of main propulsion motors.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Engineering
Issued 3 May 1996 Resolved
Demonstrate proper operation of the following manually operated remote fueloil valves: 4-80-1, 4-80-2, 4-72-1, 4-72-2, 4-72-3, 4-72-4, 4-12-1, and 4-12-2.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Accommodation/Occupational Safety
Issued 3 May 1996 Resolved
Repair all the leaks in the salt water flushing system pipes concealed above the ceilings in the long passageways.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Fire Fighting
Issued 3 May 1996 Resolved
Prove proper operation of the audible alarm function in the fire alarm_x001C_ panel for the propulsion motor space and the aft steering room.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Construction/Loadline
Issued 3 May 1996 Resolved
Make fume tight/gas tight all the breached cable penetrations in the bulkheads and decks in all stairwells.
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Documentation
Issued 20 March 1995 Resolved
HAVE THE VESSEL INSPECTED BY A COAST GUARD MARINE INSPECTOR PRIOR TO PLACING VESSEL BACK INTO SERVICE. THIS VESSEL IS NOT TO OPERATED UNTIL AN INSPECTION CAN BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Navigation
Issued 28 April 1994 Resolved
INSTALL DOUBLE LOCKNUTS FOR PORT AND STBD RUDDER POSTS.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Engineering
Issued 28 April 1994 Resolved
PROVIDE MISSING MICRO SWITCH FOR STBD MOTOR BARRING BAR.
Condition: Unknown
Due 28 April 1994
Resolved 16 May 1994
Engineering
Issued 28 April 1994 Resolved
PROVIDE REPLACEMENT FOR THE DEFECTIVE REMOTE THERMAL DEVICE FOR THE PORT MOTOR CASING.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Electrical
Issued 28 April 1994 Resolved
DEMONSTRATE THE PROPER OPERATION OF THE NO. 3 GENERATOR POWER REVERSE RELAY.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Construction/Loadline
Issued 28 April 1994 Resolved
INSTALL MISSING BILGE PUMP MOTOR FOR THE UPPER STBD BILGE PUMP IN THE MOTORROOM.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Engineering
Issued 28 April 1994 Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR AND ALL OIL CONTENT METERS.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Construction/Loadline
Issued 28 April 1994 Resolved
DEMONSTRATE THE PROPER OPERATION OF THE AUTOMATIC BILGE PUMP FOR MACHINERY SPACES.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Construction/Loadline
Issued 10 March 1994 Resolved
Replace or renew the following ten sea valves; three 5.05cm (2") swing checks, two 2.54cm (1") gates, two 15.24cm (6") swing checks, two 2.54cm (1") stop checks and one 3.81cm (1.5") globe.
Condition: Unknown
Due 15 March 1994
Resolved 15 March 1994
Construction/Loadline
Issued 10 March 1994 Resolved
Perform following sea valve repair work: Replace boot assemblies on four 10.2cm (4") and two 20.3cm (8") butterfly valves. Straighten stem of one 10.2cm (4") butterfly valve. Work shall be accomplished to the satisfactionof the attending Marine Inspector prior to placing back in service.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Engineering
Issued 10 March 1994 Resolved
Repair 15.2cm (6") indication in stbd propeller where blade meets hub. Using ABS approved weld procedure, grind out indication, fill, stress relieve and conduct dye penetrant NDT to the satisfaction of the attending Marine Inspector prior to placing propeller back on vessel.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Engineering
Issued 10 March 1994 Resolved
Make repairs to pitted areas in stbd shaft seal liner. Grind out pits and build up affected areas using manufacturer's weld procedure. Perform repairs to the satisfaction of the attending Marine Inspector prior to placing the liner back on the shaft.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Construction/Loadline
Issued 14 December 1993 Resolved
MAKE PERMANENT REPAIRS TO BALLAST TANK 4-23-3, IN WAY OF DAMAGED TANK TOP AND FORWARD BULKHEAD.
Condition: Unknown
Due 14 December 1993
Resolved 14 December 1993
Electrical
Issued 24 July 1992 Resolved
PROVE PROPER OPERATION OF NO.2 GENERATOR PRIMEMOVER LOW LUBE OIL PRESSURE AND OVERSPEED ALARMS AND TRIPS. THIS REQUIREMENT TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 24 July 1992
Resolved 24 July 1992
Lifesaving
Issued 3 September 1991 Resolved
PROVIDE APPROVED PLANS FOR LIFERAFT DAVIT INSTALLATION AND CONDUCT WEIGHT TEST OF BOTH DAVITS.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Lifesaving
Issued 26 August 1990 Resolved
REPLACE ALL BATTERIES FOR WATERLIGHTS ON IMMERSION SUITS.
Condition: Unknown
Due 26 August 1990
Resolved 26 August 1990
Fire Fighting
Issued 26 August 1990 Resolved
HAVE ALL FIRE EXTINGUISHING SYSTEMS SERVICES. SEND COPIES OF ALL PAPERWORK TO MSO.
Condition: Unknown
Due 26 August 1990
Resolved 26 August 1990
Engineering
Issued 26 August 1990 Resolved
INTERNALLY INSPECT OR HYDRO ALL PRESSURE VESSELS IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 26 August 1990
Resolved 26 August 1990
Engineering
Issued 26 August 1990 Resolved
TEST OILY WATER SEPERATOR AUTOMATIC START AND STOP SWITCHES, LOCATED IN MOTOR AND GENERATOR ROOMS WITH WATER PROVE SUCTIONSOF EACH WELL.
Condition: Unknown
Due 26 August 1990
Resolved 26 August 1990
Lifesaving
Issued 26 August 1990 Resolved
REPLACE CONTROL CABLE ON RESCUE BOAT.
Condition: Unknown
Due 26 August 1990
Resolved 26 August 1990
Lifesaving
Issued 26 August 1990 Resolved
REPLACE OR REPAIR WORM GEAR ON RESUE BOAT DAVIT.
Condition: Unknown
Due 26 August 1990
Resolved 26 August 1990
Lifesaving
Issued 27 November 1989 Resolved
MOVE OR INSTALL DECK LIGHTING FROM 02 TO 01 DECK TO PROPERLY ILLUMINATE LIFERAFT EMBARKATION AREAS AND PROPERLY INSTALL EMBARKATION LADDERS.
Condition: Unknown
Due 27 November 1989
Resolved 27 November 1989
Construction/Loadline
Issued 27 November 1989 Resolved
PROVIDE MINIMUM 1 BBL. CAP. FIXED CONTAINMENT FOR ALL FUEL VENTS AS REQUIRED BY RECENT TONNAGE INCREASE OUTLINED IN MILITARY SEALIFT COMMAND LTR 20JUN89.
Condition: Unknown
Due 27 November 1989
Resolved 27 November 1989
Deck/Cargo
Issued 5 September 1989 Resolved
REPAIR/REPLACE BILGE PUMP FLOAT SWITCHES IN BOTH THE MOTOR AND GENERATOR COMPARTMENTS. UPON COMPLETION OF SAME, CONDUCT OPERATIONAL TEST IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 5 September 1989
Resolved 5 September 1989
Fire Fighting
Issued 5 September 1989 Resolved
PROVIDE A COAST GUARD APPROVED SELF CONTAINED BREATHING APPARATUS FOR EACH FIREMAN'S OUTFIT, 2 TOTAL (RE: 46 CFR 96.35-5(B))(ADMINISTRATIVELY ISSUED)
Condition: Unknown
Due 5 September 1989
Resolved 5 September 1989
Unknown
Issued 10 August 1988 Resolved
MAKE PERMANENT REPAIRS TO INOPERABLE REACH RODS 4-12-1/1/2 (FUEL OIL SUCTION), 4-18-0 (FUEL OIL SUCTION), 4-24-3/4 (BALLAST), AND 4-66-1/2 (OILY WATER).
Condition: Unknown
Due 10 August 1988
Resolved 10 August 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.