← All vessels
STOLT COMMITMENT
STOLT COMMITMENT is a 2000 tank ship. The Coast Guard has recorded 42 inspections since 2000, most recently in October 2025, along with 5 deficiencies and 10 operational controls.
Records from 2000 to 2025. Most recent: inspection, 22 October 2025.
- Built
- 2000
- Last inspected
- 22 October 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9168647 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ZGBH8
2754
Flag
CAYMAN ISLANDS
—
Maury page id
psix-2754
Inspections, by type
…with no type recorded12
Years with a record
21 calendar years (2000–2025)
The 42 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it37438 - Dead Weight, Metric Ton
48498 - Displacement, Metric Ton
23206 - Convention (Subpart B), Gross Ton
11915 - Convention (Subpart B), Net Ton
48498 - Displacement, Metric Ton
23206 - Convention (Subpart B), Gross Ton
11915 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 42
22 October 2025
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8253868
14 May 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8136292
30 September 2024
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8009961
3 October 2023
Administrative Inspection · PSC B · COC-CHEM Renew
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7799852
29 August 2021
PSC B · COC-CHEM Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7299213
23 June 2020
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6984698
2 May 2020
PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6944025
13 May 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6682932
17 June 2018
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6443015
13 June 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6443033
23 June 2017
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6184682
22 September 2016
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6006632
1 May 2016
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5861732
23 May 2012
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4319650
18 May 2012
In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4315256
11 May 2012
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4308208
22 December 2011
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4212749
22 August 2011
ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4117062
29 March 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3705131
25 March 2010
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3700682
7 July 2009
PII Safety Exam · Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3527062
29 May 2008
ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · COC-TVE Renew · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3221501
19 January 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2858835
23 August 2006
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2757553
17 August 2006
Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2750771
31 January 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2573987
29 September 2004
ISPS II Exam · COC-CHEM Renew
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2208531
24 March 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2030180
23 March 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2029705
17 June 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1819608
23 March 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1763278
4 January 2003
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1725811
23 October 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1697076
24 July 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1651460
17 July 2002
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1647780
12 July 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1645357
23 June 2002
Ballast Water Examination · Certificate of Compliance
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1636186
22 June 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1634956
30 July 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 292392
13 May 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 77410
27 April 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 277107
27 April 2000
Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 817349
Deficiency record · 5
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 18 May 2012
Resolved
The rescue boat davit winch break is inoperable. The rescue boat davit winch must be repaired. (Flag state has authorized transit to Houston for repairs. Repairs must be made no later than 1 June 12.)
Navigation › Collision/Grounding Avoidance › Speed Near Ice
Issued 22 December 2011
Resolved
2040- Speed Log- All ships of 300 GT shall have speed and distance and measuring device or other means to indicate speed and distance through the water. Vessel's Administration provided condition that the vessel's speed log is inoperable. 74 SOLAS (09 Cons) V/19.2.3.4
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 August 2011
Resolved
2199-MARPOL Other- The oil record book shall be completed in accordance with the convention. The PSCO reviewed the oil record book part I in comparison with the 15ppm bilge alarm. The PSCO noted inconsistencies on several dates 18,19, and 20 Aug 2011. Provide corrective action plan from company with concurrence from Administration. MARPOL 73/78 ANN 1/17
Engineering › Steering Gear System › Pump
Issued 22 August 2011
Resolved
0936 Steering gear- Chemical tankers 10,000 gt and upward. PSCO observed that there was not an auto start arrangement upon loss of steering for secondary steering. The crew stated that when power is lost to primary that they must manually start from the bridge the second steering system. Request clarification from certificate issuing authority as to the adequacy of the condiction.SOLAS74 II-1/29
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 17 August 2006
Resolved
No Ballast Water Plan on Board. Vessel Addresses Ballast Water Procedures in their SMS, but they do NOT meet the requirements of 33CFR 151. 2035 (a) (7). Rectify to the satisfaction of the USCG.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.