Records from 1986 to 2026. Most recent: inspection, 9 March 2026.
Inspection history · 117
9 March 2026
Annual Inspection · Vessel Attendance
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8323449
16 April 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8112747
13 March 2025
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8092840
26 September 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8010054
7 March 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7874320
20 February 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7864930
18 January 2024
Internal Structural Exam · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7851046
9 May 2023
In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7683868
16 March 2023
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7651911
3 March 2022
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7400334
18 January 2022
Plan Review (Other than "T")
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7382092
2 March 2021
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7148124
4 March 2020
DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6920399
9 December 2019
Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6870532
7 March 2019
Annual Inspection · DAPI Audit · Deficiency Check · Security Plan Review - ASP
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6638794
12 December 2018
In-Service Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6599795
6 November 2018
Plan Review (Other than "T")
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6575793
8 March 2018
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6368697
7 November 2017
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6302530
2 March 2017
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6095507
20 January 2017
Plan Review "T" Boat
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6074343
4 January 2017
In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6065916
8 November 2016
In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6040950
22 March 2016
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5848034
18 February 2016
In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5818538
2 February 2016
Excursion Permit · In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5795539
1 August 2015
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5205778
29 October 2014
Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4953713
4 March 2014
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4782385
9 March 2010
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3674009
19 March 2009
Annual Inspection · Drydock Extension
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3416290
29 October 2008
In-Service Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3158388
11 March 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3130346
16 October 2007
Examination of Repairs
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3080618
21 March 2007
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2893110
6 March 2007
COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2861592
10 October 2006
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2797367
2 October 2006
Damage Survey
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2791932
28 September 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2794292
6 September 2006
Plan Review (Other than "T") · In-Service Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2776823
14 March 2006
Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2569060
14 March 2006
MTSA Verification
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2602975
25 May 2005
MTSA Verification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2369193
17 March 2005
Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2294066
18 February 2005
Damage Survey · Administrative Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2298552
18 August 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2176174
18 June 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2106968
12 April 2004
Annual Inspection · Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1952278
25 July 2003
In-Service Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1856942
18 March 2003
Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1709449
3 February 2003
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1736411
26 February 2002
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1476934
15 August 2001
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1070482
13 August 2001
Sanitary Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1069672
19 April 2001
Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1060746
6 March 2001
Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1463636
1 February 2001
Hull Examination · Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1376472
28 January 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 179274
14 April 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 817315
1 March 2000
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1446882
14 April 1999
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1122784
17 March 1999
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1390964
24 November 1998
Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1372425
26 October 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1411751
10 September 1998
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 804600
8 September 1998
Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1381331
6 September 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 101353
1 September 1998
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1123140
4 June 1998
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1128343
22 May 1998
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 791699
14 April 1998
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 788384
19 March 1998
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1430525
24 February 1998
Deficiency Check · Inclining Experiment
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1434677
30 September 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 143642
11 April 1997
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1098270
4 March 1997
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1421279
17 May 1996
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1082285
23 March 1996
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1417902
24 October 1995
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 873286
11 July 1995
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 883373
31 May 1995
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1183473
8 May 1995
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1350692
24 April 1995
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 858845
23 March 1995
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1360050
14 July 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 868519
20 June 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 702277
6 June 1994
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1014334
31 May 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 104435
6 May 1994
Examination of Repairs · COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1425445
25 March 1994
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1409097
4 March 1994
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1425418
16 February 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1379907
15 September 1993
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 835420
6 September 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 146410
3 June 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 165449
25 February 1993
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1148169
4 June 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1261585
30 April 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 960162
20 April 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 958602
6 April 1992
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1012177
3 March 1992
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 961007
21 November 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 107100
23 July 1991
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 940014
6 June 1991
Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1241289
4 March 1991
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1240641
27 November 1990
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1213909
5 March 1990
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 908624
18 August 1989
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1200512
7 July 1989
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1036191
22 June 1989
Deficiency Check · Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1342874
17 March 1989
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1353001
21 December 1988
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1340580
15 August 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1036385
24 August 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030509
2 March 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1027329
2 March 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1028526
27 August 1986
Hull Examination · Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1020714
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2025
Resolved
46 CFR 54.01-2 - Pressure vessels must be designed, constructed, and inspected in accordance with Section VIII of the ASME BPVC (incorporated by reference, see § 54.01-1), as limited, modified, or replaced by specific requirements in this part. (02) air tanks with compressors installed in the engine room do not meet the ASME BPV Code. Remove both tanks and compressors to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2025
Resolved 16 April 2025
Resolution: Received photos of newly installed "U" stamped UPVs.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 March 2021
Resolved
46 CFR 116.415(a)(2)(i): A-Class bulkheads or decks must be composed of steel or equivalent material...In addition, they must be so insulated with approved structural insulation...
A-Class boundary above starboard MDE in machinery space is missing insulation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2021
Resolved 2 March 2022
Resolution: Insulation in this space was installed and the boundary is satisfactory.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 March 2021
Resolved
46 CFR 118.400(a)(1): The following spaces must be equipped with a fixed gas fire extinguishing system...A space containing propulsion machinery.
After fire equipment servicing company attended to test proper operation of fixed CO2 system, the hoses from the head assy to the manifold were both found loose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2021
Resolved 2 March 2022
Resolution: Fire equipment servicer onsite tightened the hose and rectified this deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 2 March 2021
Resolved
46 CFR 116.960: An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard, or rail.
Both Port/Stbd shafts have no cover to protect crew from rotating machinery.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2021
Resolved 30 March 2022
Resolution: Operator will fabricate material and install guards.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 March 2021
Resolved
46 CFR 119.100: Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended.
Stbd MDE heat exchanger leaking water onto alternator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2021
Resolved 2 March 2022
Resolution: Leak corrected by operator before inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 March 2019
Resolved
CR01 - Install missing but required portable fire extinguisher IVO forward bar and pantry on main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2019
Resolved 14 March 2019
Resolution: 60-B:C extinguisher added to bulkhead between forward pantry and bar on main deck.
Construction/Loadline › Structures › Superstructure
Issued 8 November 2016
Resolved
PROVIDE A REPAIR PROPOSAL AND UPON USCG MSU PORTLAND APPROVAL CONDUCT REPAIRS TO THE SCULLERY SIDESHELL EXTENDING FROM JUST STBD OF THE GALLEYS AFT WEATHERTIGHT DOOR TO FORWARD OF THE FORWARD MOST GALLEY BULKHEAD TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 115.700
Action required: 705 - Other - as specified
Due 30 January 2017
Resolved 15 March 2018
Resolution: Verified repairs to sideshell, all sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (fuel injection)
Issued 28 October 2014
Resolved
Repair the port MDE fuel return line in accordance with the drawing submitted by the vessel Chief Engineer dtd 28OCT14 to the satisfaction of the attending marine inspector.
Due 13 November 2014
Resolved 19 November 2014
Resolution: Witnessed an operational test of the new port mde return fuel line, all sat.
Engineering › Bilge Water Management System › Piping
Issued 28 October 2014
Resolved
Repair deteriorated bilge pipe void 3 and other affected areas to the satisfaction of the attending Marine Inspector.
Due 23 November 2014
Resolved 19 November 2014
Resolution: Conducted a visual examination of the repaired bilge system piping and welds, all sat. Witnessed an operational test of the #3 voids bilge piping system, all sat.
Construction/Loadline › Penetrations › Pipe Flange
Issued 6 March 2007
Resolved
Make watertight the hot and cold water piping penetrations through watertight bulkheads leading to the main deck forward bar.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 20 March 2007
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 6 March 2007
Resolved
Replace missing insulation on engine room overhead starboard side.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 20 March 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 6 March 2007
Resolved
Renew 86 failed life jackets. Vessel restricted to carrying not more than 470 passengers until life jackets are replaced.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 20 March 2007
Construction/Loadline › Hull › Bottom Plating
Issued 2 October 2006
Resolved
Drydock vessel or provide underwater survey report relative to damage on starboard propeller as a result of striking a submerged object on 28 SEP 06.
Due 6 October 2006
Resolved 4 October 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 14 March 2006
Resolved
Renew time delay for fixed CO2 fire extinguishing system. NFPA 12
Due 28 March 2006
Resolved 30 March 2006
Resolution: Time delay sat.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 14 March 2006
Resolved
Clean out pressure vessel and have ready for visual Coast Guard inspection.
Due 14 April 2006
Resolved 30 March 2006
Resolution: Pressure vessel visually inspected, sat.
Engineering › Generator (propulsion/auxiliary-electric) › Measurement Circuitry
Issued 14 March 2006
Resolved
Demonstrate loss of lube oil for both generators.
Due 14 April 2006
Resolved 30 March 2006
Resolution: Loss of lube oil shutdowns for both generators demonstrated.
Accommodation/Occupational Safety › Potable Water System › General
Issued 17 March 2005
Resolved
Provide a plan to re-pipe the potable water piping so that it is not running thru the sewage tank. Include a timeframe for completion of this project in the plan. Complete no later than 25MAR05.
Due 25 March 2005
Resolved 25 March 2005
Construction/Loadline › Structures › Deck Plating
Issued 15 April 2004
Resolved
Provide a written proposal to correct the fire protection issues discovered on the 09Mar04 Hull inspection ( see CG-835's TJN01 thru TJN03). LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Due 31 May 2004
Resolved 18 August 2004
Fire Fighting › Structural - A Class Divisions › Doors
Issued 15 April 2004
Resolved
Replace all "B-Class" doors with approved "A-Class" doors. Numerous fire screen doors are "B-Class" vice "A-Class" as required by the approved the vessel plans. Several of these doors are in the stairways. 46 CFR 72.05 LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper Installation
Due 31 May 2004
Resolved 18 June 2004
Resolution: SEE VESSEL FILE AND NARITIVE FOR DETAILS
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 15 April 2004
Resolved
Install approved insulation where missing in overhead of all "A-Class" decks/boundaries. 46 CFR 72.05 LEGACY COMPONENT DESC: Overhead Insulation
Condition: Improper/Lack of Maintenance
Due 31 May 2004
Resolved 18 August 2004
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 15 April 2004
Resolved
Provide/install approved fire stop material for all cable penetrations in "A-Class" boundaries LEGACY COMPONENT DESC: "A-Class" Boundry Penetrations
Condition: Improper/Lack of Maintenance
Due 31 May 2004
Resolved 18 August 2004
Accommodation/Occupational Safety › Cooking Systems
Issued 18 March 2003
Resolved
Clean galley exhaust vent ducting. LEGACY COMPONENT DESC: Exhaust Vent
Due 28 March 2003
Resolved 25 March 2003
Operations/Management › Drug and Alcohol Testing
Issued 18 March 2003
Resolved
Enroll all crewmwmbers, bartenders, wait staff, and other employees that have safety sensitive duties in random drug testing program that complies with 46 CFR part 16 (See G-MOA policy letter 1-97). LEGACY COMPONENT DESC: Employee Coverage
Due 19 April 2003
Resolved 24 April 2003
Resolution: [name withheld], [name withheld], elected to shift crewmember responsibilities on the station bill in lieu of enrolling all crew members in random test pool. All bartenders and service managers are now the required deckhands [name withheld] 1-97.
Fire Fighting › Fire Pumps
Issued 18 March 2003
Resolved
Demonstrate operation of fire pump controller in CO2 room. LEGACY COMPONENT DESC: Power Source
Due 28 March 2003
Resolved 25 March 2003
Electrical › Electrical Distribution System (service)
Issued 26 February 2002
Resolved
In the pump room, permanently wire sanitary pumps and the reefer compressor/condensor unit. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 26 March 2002
Resolved 26 March 2002
Electrical › Electrical Distribution System (service)
Issued 26 February 2002
Resolved
Make the wire penetrations, adjacent to the stbd generator exhaust piping, in way of the aft engineroom bulkhead watertight. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 1 April 2002
Resolved 26 March 2002
Electrical › Electrical Distribution System (service)
Issued 26 February 2002
Resolved
Replace all under-size and plastic wire hangars with 5/8ths wide steel bands so tha they support overhead electrical cable runs every 24 inches. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 1 May 2002
Resolved 25 April 2002
Accommodation/Occupational Safety › Potable Water System
Issued 26 February 2002
Resolved
In the lower pumproom, properly bracket 2 ea. 1/2 -inch pipe runs (water piping) located on the fwd bulkhead. One pipe is resting on an electrical connection box. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 26 March 2002
Resolved 26 March 2002
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 26 February 2002
Resolved
In the lower pumproom walk-in chill box, clean storage racks and clear condensate drain lines. (Fan blades are spinning through backed-up condensate) LEGACY COMPONENT DESC: walk-in chill box in pumproom
Condition: Improper/Lack of Maintenance
Due 26 March 2002
Resolved 26 March 2002
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 26 February 2002
Resolved
In the lower pumproom, remove the small reach-in freezer from the vessel. (The door is severely wasted). LEGACY COMPONENT DESC: Reach-in Freezer
Condition: Improper/Lack of Maintenance
Due 26 March 2002
Resolved 26 March 2002
Accommodation/Occupational Safety › Potable Water System
Issued 26 February 2002
Resolved
In the lower pumproom, clean/sanatize the hopper (ice storage) in the ice maker machine. Also, re-attach condensate drain line inside the hopper; repair/renew the hopper door; repair/reseal the housing joints to prevent excessive drainage into the hopper. LEGACY COMPONENT DESC: Ice Machine
Condition: Improper/Lack of Maintenance
Due 26 March 2002
Resolved 26 March 2002
Accommodation/Occupational Safety › Messroom
Issued 26 February 2002
Resolved
Repair/renew all buckled/loose deck covering in the galley behind the dishwasher assy. This area is collecting water which remains trapped to corrode the steel deck foundation. LEGACY COMPONENT DESC: Galley deck
Condition: Improper Installation
Due 26 April 2002
Resolved 25 April 2002
Lifesaving › Lifebuoys
Issued 26 February 2002
Resolved
Renew grab lines on ring buoys which are deteriorated (3 identified). LEGACY COMPONENT DESC: Grab lines
Due 26 March 2002
Resolved 12 March 2002
Resolution: Lines renewed.
Documentation › Certificates/Documents
Issued 26 February 2002
Resolved
Obtain new or ammended Certificate of DOCUMENTATIO (COD) that reflects an endorsement for Coastwise trade. (Vessel had this endorsement ammended to the original cert. but ammendment sticker was missing) LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 26 March 2002
Resolved 26 March 2002
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 26 February 2002
Resolved
In the galley walk-in chill box (reefer): repair/renew the door latch as original; clean the stowage racks, floor, and the fan guard. LEGACY COMPONENT DESC: Galley Walk-in Reefer
Condition: Improper/Lack of Maintenance
Due 26 March 2002
Resolved 21 March 2002
Accommodation/Occupational Safety › Messroom
Issued 26 February 2002
Resolved
In the galley, Clean the metal surfaces on the under side of the food warmers. LEGACY COMPONENT DESC: Food warmers
Condition: Improper/Lack of Maintenance
Due 26 March 2002
Resolved 21 March 2002
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 26 February 2002
Resolved
In the galley, thoroughly clean all accumulated grease from the range exhaust ducting and fan housing.
Condition: Improper/Lack of Maintenance
Due 26 March 2002
Resolved 28 February 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 26 February 2002
Resolved
In the engineroom, renew/replace missing exhaust pipe hangar bolt for the port MDE exhaust piping system. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper Installation
Due 26 March 2002
Resolved 28 February 2002
Engineering › Steering Gear System
Issued 26 February 2002
Resolved
Renew motor mounts for the steering pump (flex mounts deteriorated/softened by hydraulic fluid contact -excessive leakage). Also, repair excessive leakage. LEGACY COMPONENT DESC: Motor
Due 26 March 2002
Resolved 26 March 2002
Construction/Loadline › Structures › Deck Plating
Issued 26 February 2002
Resolved
Crop and renew overhead steel deck (main deck under galley walk-in reefer) in way of the stbd exhaust piping and aft bulkhead in the engineroom. Submit proposal for repairs prior to commencing work. Vessel may not sail until this is corrected.
Condition: Improper/Lack of Maintenance
Due 5 March 2002
Resolved 8 March 2002
Engineering › Steering Gear System
Issued 26 February 2002
Resolved
Renew cracked hydraulic hoses in the hydraulic steering rames. Three were noted with outer jacket cracks - the remaining appear to be fairly aged. Hoses to be SAE J-1942. LEGACY COMPONENT DESC: Hydraulic Hose
Due 26 March 2002
Resolved 26 March 2002
Fire Fighting › Structural - A Class Divisions
Issued 26 February 2002
Resolved
Restore the structural fire protection insulation to A-60 level in the galley forward bulkhead and the enginroom overhead . In the galley fwd bulkhead, all drilled holes (from previous mountings) must be filled. This may be done by inserting steel screws in the holes. LEGACY COMPONENT DESC: Bulkheads - Main Galleys
Condition: Improper Installation
Due 1 April 2002
Resolved 25 April 2002
Fire Fighting › Ventilation Systems
Issued 26 February 2002
Resolved
Prove proper operation of all fire damper closing devices, identified on 28FEB02, as they were located above the drop-ceiling panels in way of the galley entrance door. Also, provide markings indicating their location. LEGACY COMPONENT DESC: Ducts
Condition: Improper Installation
Due 1 April 2002
Resolved 26 March 2002
Documentation
Issued 13 August 2001
Resolved
POST CERTIFICATE OF INSPECTION IN A LOCATION LIKELY TO BE SEEN BY PASSENGERS.
Condition: Unknown
Due 13 August 2001
Resolved 13 August 2001
Accommodation/Occupational Safety
Issued 13 August 2001
Resolved
THOROUGHLY CLEAN GALLEY TO A SANITARY CONDITION. VENT HOODS, BULKHEADS AND DECKS AROUND AND UNDER GRILLS, WALK IN REFRIGERATOR, INSIDE FOOD WARMERS AND OVENS AND ALL COOKING SURFACES.
Condition: Unknown
Due 13 August 2001
Resolved 13 August 2001
Accommodation/Occupational Safety
Issued 13 August 2001
Resolved
SUBMIT FOR REVIEW AND APPROVAL PROPOSAL TO RENEW OR REMOVE OVERHEAD FIBERGLASS INSULATION WITH EXPOSED FIBERGLASS FIBERS IN GALLEY. PROPOSAL MUST INCLUDE SCOPE OF WORK AND TIME FRAME TO ACCOMPLISH WORK.
Condition: Unknown
Due 13 August 2001
Resolved 13 August 2001
Fire Fighting
Issued 6 March 2001
Resolved
PROVIDE PROOF OF SERVICING AND PROPER OPERATION OF GALLEY HOOD FIRE EXTINGUISHING SYSTEM PRIOR TO USE OF ANY GALLEY EQUIPMENT PROTECTED BY SYSTEM. TESTING TO BE WITNESSED AND TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 6 March 2001
Resolved 6 March 2001
Construction/Loadline
Issued 1 February 2001
Resolved
Complete proper permanent repairs to temporary repair on bow approximately 8ft above waterline and located internally in fwd storage closet. To be completed to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Documentation
Issued 1 March 2000
Resolved
OBTAIN VALID FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Documentation
Issued 1 March 2000
Resolved
OBTAIN VALID SHIP RADIO STATION LICENSE.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Accommodation/Occupational Safety
Issued 17 March 1999
Resolved
Reinstall upper deck passenger limit sign in entranceway visible to passengers.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Fire Fighting
Issued 17 March 1999
Resolved
Prove proper operation of the starboard generator shutdown for fixed CO2 fire fighting system.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Fire Fighting
Issued 17 March 1999
Resolved
Re-install insulation for forepeak above overhead, for second deck underdeck.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Fire Fighting
Issued 17 March 1999
Resolved
Reconnect the dampers in the galley.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Construction/Loadline
Issued 17 March 1999
Resolved
Renew the drain for the upper deck, port side.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Lifesaving
Issued 17 March 1999
Resolved
Properly insulate the bare manifold for the starboard generator exhaust.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Electrical
Issued 8 September 1998
Resolved
Replace as original the port running light.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Accommodation/Occupational Safety
Issued 19 March 1998
Resolved
PROPERLY SECURE THE COMPRESSED GAS CYLINDERS OUTSIDE GALLEY AND IN THE PUMPROOM.
Condition: Unknown
Due 14 April 1998
Resolved 14 April 1998
Documentation
Issued 19 March 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Lifesaving
Issued 19 March 1998
Resolved
CONDUCT TEST TO ENSURE THE RELIEF VALVE IS WORKING PROPERLY ON THE PRESSUREVESSELS.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Documentation
Issued 19 March 1998
Resolved
PROVIDE A RADIO STATION LICENSE.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Fire Fighting
Issued 19 March 1998
Resolved
HAVE NEW FIXED ENGINE ROOM CO2 SYSTEM INSPECTED BY A USCG INSPECTOR PRIOR TO PLACING THE SYSTEM ON LINE.
Condition: Unknown
Due 14 April 1998
Resolved 14 April 1998
Electrical
Issued 19 March 1998
Resolved
CONDUCT OVERSPEED, LOW LUBE, AND HIGH TEMP SHUT DOWNS ON BOTH SHIP SERVICE GENERATORS.
Condition: Unknown
Due 14 April 1998
Resolved 14 April 1998
Lifesaving
Issued 19 March 1998
Resolved
PROVIDE A PFD DONNING PLACARD FOR EACH TYPE OF PFD CARRIED ON BOARD VESSEL.
Condition: Unknown
Due 14 April 1998
Resolved 14 April 1998
Electrical
Issued 19 March 1998
Resolved
PROPERLY SECURE BATTERY BOX UNDER BRIDGE CONTROL PANEL.
Condition: Unknown
Due 14 April 1998
Resolved 14 April 1998
Lifesaving
Issued 24 February 1998
Resolved
PROVIDE SATISFACTORY STABILITY TEST REVIEW FROM USCG MARINE SAFETY CENTER. VESSEL IS RESTRICTED TO 400 PASSENGERS UNTIL SATISFACTORY REVIEW IS COMPLETED.
Condition: Unknown
Due 14 April 1998
Resolved 14 April 1998
Engineering
Issued 24 February 1998
Resolved
RECONNECT INTAKE AIR FILTER TO THE PORT MAIN ENGINE.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Engineering
Issued 11 April 1997
Resolved
SUBMIT PLANS TO INSTALL ADAQUATE SUPPLY AND EXHAUST VENTILATION IN THE MACHINERY SPACE.
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Engineering
Issued 11 April 1997
Resolved
INSTALL/MODIFY VENTILATION SYSTEM IN THE MACHINERY SPACE IN ACCORDANCE WITHCOAST GUARD APPROVED PLANS.
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Engineering
Issued 11 April 1997
Resolved
RECONNECT INTAKE AIR FILTERS TO PORT AND STARBOARD MAIN ENGINES OR PROVIDE OTHER MEANS ACCEPTABLE TO MANUFACTURER AND ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Lifesaving
Issued 4 March 1997
Resolved
PROVIDE A DETACHABLE NON CORROSIVE CLIP FOR THE RING BUOY WATERLIGHT.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Unknown
Issued 4 March 1997
Resolved
UPDATE STATION BILL TO REFLECT SPECIFIC DUTIES OF CREWMEMBERS.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Navigation
Issued 4 March 1997
Resolved
UPDATE CHARTS CURRENTLY IN USE OR PROVIDE NEW CHARTS.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Engineering
Issued 4 March 1997
Resolved
MAKE REPAIRS AS NECESSARY TO ALLOW FOR FULL CLOSURE WITH THE PORT REMOTE FUEL SHUTOFF.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Fire Fighting
Issued 4 March 1997
Resolved
CORRECT THE ALIGNMENT OF THE FIRE DOOR TO THE UPPER DECK (COLUMBIA) TO ALLOW FOR PROPER CLOSURE.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Electrical
Issued 4 March 1997
Resolved
DEMONSTRATE OVERSPEED FOR THE GENERATORS.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Lifesaving
Issued 4 March 1997
Resolved
PROVIDE A LOCK FOR THE AIR CONDITIONER POWER BOX.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Lifesaving
Issued 4 March 1997
Resolved
REMOVE THE TWO BARBEQUE GRILL UNITS FROM THE VESSEL, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Unknown
Issued 4 March 1997
Resolved
PROVIDE PLANS FOR THE INSTALLATION OF THE NEW AIR COMPRESSOR.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Lifesaving
Issued 4 March 1997
Resolved
PENDING RESOLUTION OF RESCUE BOAT REQUIREMENTS, PROVIDE A QUALIFIED RESCUE SWIMMER WITH DRY SUIT AND ALL ASSOCIATED ACCESSORIES.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Lifesaving
Issued 4 March 1997
Resolved
PROVIDE RETROREFLECTIVE TAPE FOR THE RING BUOYS.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Accommodation/Occupational Safety
Issued 4 March 1997
Resolved
PROVIDE REQUIRED MARKINGS AT UPPER LEVEL ENTRIES FOR MAXIMUM PASSENGER RESTRICTIONS.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Accommodation/Occupational Safety
Issued 4 March 1997
Resolved
MARK THE ESCAPE HATCH COVERS FOR THE ENGINE ROOM AND PUMP ROOM AS REQUIRED.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Electrical
Issued 4 March 1997
Resolved
INSTALL PROPER ELECTRICAL MATTING FOR THE ENGINE ROOM SWITCHBOARD.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Electrical
Issued 4 March 1997
Resolved
PROVIDE DRIPPROOF ELECTRICAL RECEPTACLES FOR THE ENGINEROOM.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Electrical
Issued 4 March 1997
Resolved
REPAIR THE INOPERATIVE EMERGENCY LIGHT AT ENTRANCE TO THE ENGINE ROOM.
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Electrical
Issued 23 March 1996
Resolved
REPLACE ANTENA BOX COVER. (LOWER BAR FWD)
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Electrical
Issued 23 March 1996
Resolved
REMOVE GANG OUTLET AND/OR PROVIDE STRIP OUTLET W/BREAKER.(UPPER AFT BAR)
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Electrical
Issued 23 March 1996
Resolved
STENCIL "STOVE DISCONNECT" ON BREAKER PANEL BOX.
Condition: Unknown
Due 23 March 1996
Resolved 23 March 1996
Lifesaving
Issued 23 March 1996
Resolved
PROVIDE RESCUE BOAT OR SUITABLE PLATFORM.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Electrical
Issued 23 March 1996
Resolved
PROVIDE EXTERNAL ON/OFF BUTTONS ON SEWAGE PUMP CONTROLER BOX.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Electrical
Issued 23 March 1996
Resolved
PROVIDE COVER ON FOURPLEX OUTLET (LOWER AFT BAR, AFT WALL)
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Electrical
Issued 23 March 1996
Resolved
REMOVE ELEC CORD OFF FLOOR OR PROVIDE STEP COVER (LOWER AFT BAR)
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Lifesaving
Issued 23 March 1996
Resolved
REMOVE LINEN FROM FWD PFD LOCKER.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Accommodation/Occupational Safety
Issued 23 March 1996
Resolved
CLEAN UP AND RESEAL PUMP DISCHARGE PIPING (WATER SUPPLY FOR SEWAGE SYSTEM).
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Fire Fighting
Issued 23 March 1996
Resolved
REPLACE FIRE PUMP DISCHARGE GAUGE.
Condition: Unknown
Due 23 March 1996
Resolved 23 March 1996
Accommodation/Occupational Safety
Issued 23 March 1996
Resolved
PROVIDE 200PSI OR GREATER VALVES (2) AND CHECK VALVES (2) ON AIR RECEIVER TANK PIPING.
Condition: Unknown
Due 23 March 1996
Resolved 23 March 1996
Electrical
Issued 23 March 1996
Resolved
PROVE PROPER OPERATION OF STBD GENERATOR OVERSPEED DEVICE.
Condition: Unknown
Due 23 March 1996
Resolved 23 March 1996
Electrical
Issued 23 March 1996
Resolved
MOUNT JUNCTION BOX AND CLEAN DUST FROM ELEC. WIRES (LOWER DISCO LIGHTS)
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Accommodation/Occupational Safety
Issued 23 March 1996
Resolved
STENCIL HATCH IN LOWER LOUNGE " COLLISION BLKHD BILGE VALVE SHUTOFF".
Condition: Unknown
Due 23 March 1996
Resolved 23 March 1996
Electrical
Issued 23 March 1996
Resolved
PROVIDE OUTLET COVER AND MOUNT STRIP OUTLET (LOWER BAR FWD)
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Electrical
Issued 23 March 1996
Resolved
REPLACE SPLICED ELEC. WIRE FOR A/C COMPRESSOR (LOWER BAR FWD)
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Electrical
Issued 23 March 1996
Resolved
REMOVE DEAD END WIRES ON UPPER AND LOWER DISCO LIGHTS
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Electrical
Issued 23 March 1996
Resolved
ROUTE CASH REGISTER WIRE IN GALLEY USING EXISTING WIRE WAYS
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Electrical
Issued 23 March 1996
Resolved
REPLACE SHORTED ELEC OUTLET IN GALLEY ON FWD BLKHD.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Electrical
Issued 23 March 1996
Resolved
HARD WIRE DISHWASHER CHEMICAL DISPENCER.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Electrical
Issued 23 March 1996
Resolved
REPAIR OR REPLACE OVERHEAD FLUORESCENT LIGHTS AND COVER IN GALLEY.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Electrical
Issued 23 March 1996
Resolved
SEAL UP ELEC DECK PENETRATION (GALLEY AFT)
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Fire Fighting
Issued 23 March 1995
Resolved
Provide proof of hydrostatic testing of fixed halon in galley._x001C_
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Lifesaving
Issued 23 March 1995
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE 2 ADDITIONAL VALID ORANGE SMOKE FLARES.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Engineering
Issued 23 March 1995
Resolved
Prove proper operation of relief valve on air receiver and hydrostatically test or provide for visual inspection of air receiver._x001C_
Condition: Unknown
Due 5 April 1995
Resolved 10 April 1995
Documentation
Issued 23 March 1995
Resolved
Provide proof of valid FCC operators license for mate. Vsl restricted to routes not more than 1000 feet from land._x001C_
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Documentation
Issued 23 March 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Accommodation/Occupational Safety
Issued 6 May 1994
Resolved
PERFORM PROPER TEST OF AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Navigation
Issued 16 February 1994
Resolved
RENEW RUDDER ANGLE INDICATOR SENDING UNIT.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Accommodation/Occupational Safety
Issued 20 April 1992
Resolved
INSTALL RAILS PORT AND STBD OF THE ROOF TOP TO THE 02 DECK AT THE EDGE IN WAY OF THE AREA WHERE THE BUOYANT APPARATUS ARE STOWED AND LAUNCHED. RAILSSHALL BE A LEAST 1 COURSE 36" HIGH AND AT LEAST 8 FEET LONG.
Condition: Unknown
Due 20 April 1992
Resolved 20 April 1992
Lifesaving
Issued 20 April 1992
Resolved
INSTALL STOWAGE BINS ON THE 01 DECK SO THAT AT LEAST 100 ADULT AND 10 CHILDREN LIFE PRESERVERS WILL BE CONVENIENTLY AVAILABLE TO PASSENGERS LOCATED ON THAT DECK.
Condition: Unknown
Due 20 April 1992
Resolved 20 April 1992
Accommodation/Occupational Safety
Issued 20 April 1992
Resolved
REPLACE THE 30 INCH WIDE CENTERLINE DOOR IN THE AFT BULKHEAD OF THE 01 DECKWITH AT LEAST A 36 INCH WIDE DOOR SO IT CAN EFFECTIVELY BE USED AS A MEANS OF ESCAPE DURING EMERGENCIES. (RE: 46CFR TABLE 72.05-20(S) AND NVIC 14-91)
Condition: Unknown
Due 20 April 1992
Resolved 20 April 1992
Construction/Loadline
Issued 6 April 1992
Resolved
RENEW BILGE STRAINER IN WAY OF POTABLE WATER TANK.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Construction/Loadline
Issued 6 April 1992
Resolved
RENEW BILGE STRAINER IN LAZARETTE.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Construction/Loadline
Issued 6 April 1992
Resolved
RENEW BILGE STRAINER IN SUCTION LINE FORWARD OF MSD STORAGE TANK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Electrical
Issued 3 March 1992
Resolved
PERMANENTLY MOUNT THE BATTERY SWITCH FOR THE #2 GENERATOR.
Condition: Unknown
Due 3 March 1992
Resolved 3 March 1992
Navigation
Issued 3 March 1992
Resolved
REPAINT THE NAVIGATION LIGHT SCREENS FLAT BLACK OR MATTE BLACK.
Condition: Unknown
Due 3 March 1992
Resolved 3 March 1992
Unknown
Issued 6 June 1991
Resolved
REPLACE 01 WEATHER DECK DOORS WITH 1.75" THICK HARDWOOD DOORS IN ACCORDANCEWITH 46CFR72.05-25(B)(8). GLASS FITTED INTO THESE DOORS SHALL BE OF THE WIRE INSERTED TYPE.
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Unknown
Issued 6 June 1991
Resolved
TAG ALL FIRE DAMPER MANUAL RELEASE CABLES SO THAT THEY CAN BE EASILY IDENTIFIED.
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Unknown
Issued 6 June 1991
Resolved
REPLACE ALL REMAINING WOODEN FRAMED CHAIRS WITH METALLIC FRAMED TYPES.
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Unknown
Issued 6 June 1991
Resolved
REPLACE PLYWOOD INSERT PANELS IN PILOTHOUSE AND STORAGE SPACE DOOR (AFT OF PILOT HOUSE) WITH 1.75" HARDWOOD INSERTS.
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Lifesaving
Issued 5 March 1990
Resolved
PROVIDE TWO OPERABLE WATERLIGHTS FOR TWO BUOYANT APPARATUS.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Electrical
Issued 5 March 1990
Resolved
PROVIDE SOCKET COVERS AS NEEDED THROUGHOUT VESSEL.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Fire Fighting
Issued 5 March 1990
Resolved
PROVIDE EVIDENCE OF SERVICING FOR 5 B-II PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Navigation
Issued 5 March 1990
Resolved
DOUBLE NUT TILLER ARM FITTING FOR STBD STEERING GEAR.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Electrical
Issued 5 March 1990
Resolved
PROVIDE JUNCTION BOX FOR EXPOSED LIGHT WIRING IN PUMP ROOM.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Engineering
Issued 7 July 1989
Resolved
RECONNECT FOREPEAK BILGE SUCTION LINE SO THAT IT CAN BE OPERATED FROM THE BILGE MANIFOLD LOCATED IN THE ENGINE ROOM. FOREPEAK BILGE CONTROL VALVE NOW LOCATED IN VOID NO. 5. (REF 46 CFR 182.25-5(C).) (ADMINISTRATIVELY ISSUED).
Condition: Unknown
Due 7 July 1989
Resolved 7 July 1989
Engineering
Issued 22 June 1989
Resolved
TEST THE PORT AND STARBOARD MAIN ENGINES, ALL GENERATORS, AND PERFORM A STEERING GEAR TEST PRIOR TO DEPARTURE FROM PORT OF SAN DIEGO.
Condition: Unknown
Due 22 June 1989
Resolved 22 June 1989
Engineering
Issued 22 June 1989
Resolved
REPAIR AS ORIGINAL ALL DAMAGED INSULLATION IN THE ENGINEROOM OVERHEAD IN WAY OF THE PORT ENGINE.
Condition: Unknown
Due 22 June 1989
Resolved 22 June 1989
Engineering
Issued 22 June 1989
Resolved
PROVIDE PLANS TO [name withheld] FOR MODIFICATION TO MAIN ENGINE EXHAUSTS. WORKMANSHIP TO BE COMPLETED IN ACCORDANCE WITH GOOD MARINE PRACTICE AND TO THE SATISFACTION OF [name withheld].
Condition: Unknown
Due 22 June 1989
Resolved 22 June 1989
Engineering
Issued 17 March 1989
Resolved
INSTALL A REACHROD FOR THE FOREPEAK BILGE SUCTION VALVE SO AS TO BE OPERABLE FROM THE MAIN DECK, PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Navigation
Issued 17 March 1989
Resolved
CCONTACT THE COGNIZANT [name withheld] IN THE HONOLULU, HI MARINE INSPECTION ZONE.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Documentation
Issued 17 March 1989
Resolved
PROVIDE ON BOARD THE CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Documentation
Issued 17 March 1989
Resolved
PROVIDE ON BOARD A VALID FCC SAFETY ACT RADIOTELEPHONY CERTIFICATE AND SHIPSTATION LICENSE PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Unknown
Issued 21 December 1988
Resolved
MAKE THE SIGHT GLASSES ON THE POTABLE WATER TANKS SAFE FROM DAMAGE AND ACCIDENTAL DISCHARGE OF THE WATER INTO THE BILGES. THE ABOVE REQUIREMENT ISTO BE COMPLETED PRIOR TO DEPARTURE FOR HAWAII.
Condition: Unknown
Due 21 December 1988
Resolved 21 December 1988
Engineering
Issued 15 August 1988
Resolved
REPAIR THE PILOT HOUSE MAIN ENGINE ALARM PANEL TO WORKING CONDITION.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Documentation
Issued 15 August 1988
Resolved
OBTAIN AND PLACE ONBOARD A VALID FCC RADIOTELEPHONE CERTIFICATE,
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Fire Fighting
Issued 15 August 1988
Resolved
ADJUST ALL FIRE HYDRANTS SO THE SPANNER WRENCHES MAY BE PROPERLY USED TO ATTACH THE FIRE HOSES.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988