← All vessels
JACK D
JACK D is a 1986 tank ship. The Coast Guard has recorded 60 inspections since 1986, most recently in January 2007, along with 35 deficiencies and 4 operational controls.
Records from 1986 to 2007. Most recent: inspection, 17 January 2007.
- Built
- 1986
- Last inspected
- 17 January 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 35 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7915632 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6EZ2
275744
Flag
BAHAMAS, THE
—
Maury page id
psix-275744
Inspections, by type
…with no type recorded42
Years with a record
22 calendar years (1986–2007)
The 60 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it31108 - Regulatory (Subpart C or D), Net Ton
122587 - Displacement, Ton
98358 - Dead Weight, Ton
59850 - Regulatory (Subpart C or D), Gross Ton
122587 - Displacement, Ton
98358 - Dead Weight, Ton
59850 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 60
17 January 2007
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2857224
14 March 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2602536
14 March 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2611023
13 March 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2601727
10 March 2006
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2600250
7 October 2005
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2509817
5 May 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2060118
21 April 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2049156
20 April 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2048415
3 June 2003
Certificate of Compliance · Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1805438
21 January 2003
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1733097
25 May 2002
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1617924
13 August 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 292623
13 August 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 757001
12 August 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 209462
19 March 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 288079
19 March 2001
Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1061257
24 March 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 275725
1 February 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 274118
1 February 2000
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 814901
4 April 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 427314
2 February 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 425226
8 August 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 418950
10 October 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 408583
2 October 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 408645
2 October 1997
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1110804
25 September 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 757578
24 September 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 191901
28 March 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 402048
16 January 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 758661
15 January 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 191896
12 October 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 396102
15 November 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 384980
28 August 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 382084
16 April 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 376978
22 August 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 871246
17 August 1994
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 369398
17 August 1994
Tank Vessel Examination · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1179869
1 April 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 445732
1 July 1993
MARPOL Annex I Examination · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1157430
9 January 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 355510
14 September 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261490
3 September 1992
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 668013
18 August 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 530489
10 August 1992
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 116608
20 May 1992
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 958797
19 May 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 343877
19 May 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1229937
29 September 1990
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 444539
15 March 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 335974
15 March 1990
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 923935
12 December 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 478027
11 March 1989
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 891191
7 September 1988
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 524610
5 March 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 321677
5 March 1988
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1033365
1 December 1987
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 510304
29 June 1987
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 519822
1 December 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 313104
1 December 1986
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1022914
Deficiency record · 35
Deck/Cargo › Mooring/Anchoring › Winch
Issued 7 October 2005
Resolved
ALL 3 MOORING WINCHES HYDRAULIC PUMPS ARE LEAKING AT SEALS, CAUSING ACCUMILATION. TO THE SATISFACTION OF THE ADMINISTRATION.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Electric Bonding
Issued 7 October 2005
Resolved
SEVERAL PIPE CONNECTIONS, FLANGES, BRACKETS AND OR GROUNDING STRAPS ARE SEVERLY WASTED AND WORN OR BROKEN ON CARGO LINE ON DECK.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 October 2005
Resolved
CONDUIT FOR ELECTRICAL CABLES ON CARGO DECK HAS EXTENSIVE WASTAGE.
Fire Fighting › Fire Hoses › Condition
Issued 7 October 2005
Resolved
FIRE HOSE IN ENGINE ROOM PUNCTURED.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 7 October 2005
Resolved
HYDRAULIC PIPE TO #5 CARGO HATCH BROKEN.
Deck/Cargo › Ballast › Piping
Issued 7 October 2005
Resolved
BALLAST WATER PIPING HAS HOLE/WASTAGE ( IN CARGO PUMP ROOM).
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 7 October 2005
Resolved
CARGO PUMP ROOM HAS SEVERAL IMPROPERLY SEALED OR DAMAGED ELECTRICAL CONNECTIONS.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 7 October 2005
Resolved
CARGO PUMP ROOM HAS EVIDENCE OF SEVERAL CARGO LEAKS IN VACINITY OF PUMPS/ STRAINERS.
Engineering › Bilge Water Management System › Valve
Issued 7 October 2005
Resolved
BILDGE SYSTEM REACH RODS IN CARGO PUMP ROOM ARE DAMAGED, WASTED AND OR INOPERABLE.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 3 June 2003
Resolved
Vsl was issued a letter of deviation to enter the Port of Corpus Christi with an inoperable primary radar (33CFR 164.35(a)).
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 25 May 2002
Resolved
Patch on boiler intake to scrubber, inspection plate on scrubber with improper seal. SOLAS 74(Amend) CH II-2 Reg 62.8.I. Show class surveyor report verifying permanent repairs.
Deck/Cargo › Inert Gas System
Issued 25 May 2002
Resolved
IGS span gas/02 sensing point not located on IGS main line. SOLAS 74(Amend) CH II-2 Reg 62.16.I.2. Show class surveyor report verifying system operation arrangement.
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 25 May 2002
Resolved
Excessive soot/exhaust leaks from both auxiliary boilers. SOLAS 74(Amend) CH I-Reg II. Show class report on inspection and survey of auxiliary boilers.
Engineering
Issued 25 May 2002
Resolved
Possible leak (water) from #steam turbine/#cargo pumps. SOLAS 74(Amend) Reg 56/CH I-Reg II. Show class surveyor report verifying gas tight arrangement between pumproom/engine room.
Engineering
Issued 25 May 2002
Resolved
Excessive water/steam leaks on all cargo pump steam turbines. SOLAS 74(Amend) CH I-Reg II/CH II-I Reg 26. Show class surveyor report verifying repairs/operation.
Engineering › Compressed Air System (control)
Issued 25 May 2002
Resolved
Air compressor in engine room with portable air duct for cooling. SOLAS 74(Amend) CH I-Reg II/CH II-I Reg 26. Submit class surveyor report verifying proper operation. LEGACY COMPONENT DESC: Compressor
Lifesaving
Issued 1 February 2000
Resolved
STARBOARD LIFEBOAT FORWARD, LOWER WHEEL/ROLLER IS MISSING RUBBER. REPLACE TO SATISFACTION OF CLASS BY 01MAR00. FAX COPY TO USCG.
Deck/Cargo
Issued 2 February 1999
Resolved
PRIOR TO NEXT U.S. PORT, MAKE PERMANENT AND PROPER REPAIRS TO THE FIXED OXYGEN ANALYZER (INERT GAS SYSTEM), AND SHOW PROPER OPERATION INCLUDING PROPER CALIBRATION OF METER. VESSEL IS TO ENSURE ALL CARGO TANKS REMAIN PROPERLY INERTED AND A LOGBOOK KEPT OF ALL TANK O2 READINGS OBTAINED.
Documentation
Issued 2 February 1999
Resolved
VESSEL NOT PROPERLY MANNED IN ACCORDANCE WITH SAFE MANNING CERTIFICATE (C/ELICENSE EXPIRED). PRIOR TO DEPARTURE FROM THE PORT OF NEW ORLEANS, ENSURE THE VESSEL IS PROPERLY MANNED, AND A PROPERLY LICENSED C/E IS ON BOARD.
Lifesaving
Issued 2 February 1999
Resolved
PROVIDE PROPER PHONE LIST NUMBERS FOR PHONE IN STEERING GEAR SPACE.
Deck/Cargo
Issued 2 October 1997
Resolved
CARGO PUMP #1 IS TO BE TAKEN OUT OF SERVICE UNTIL THE EMERGENCY SHUTDOWN SYSTEM IS REPAIRED AND VERIFIED.
Deck/Cargo
Issued 2 October 1997
Resolved
REPAIR/ PROVIDE THE AUTOMATIC SHUTDOWN DEVICE FOR LOSS OF NORMAL WATER SUPPLY TO THE DECK WATER SEAL IAW 46 CFR 32.53-70(B)(3) PRIOR TO NEXT U.S. PORT.
Deck/Cargo
Issued 2 October 1997
Resolved
REPAIR THE ENGINE ROOM/ CONTROL ROOM ALARMS FOR THE CARGO PUMP EMERGENCY SHUTDOWN SYSTEM PRIOR TO NEXT U.S. PORT.
Construction/Loadline
Issued 2 October 1997
Resolved
REPAIR AND PROVE PROPER OPERATION OF THE 15 PPM OILY WATER SEPERATOR ALARM PRIOR TO NEXT U.S. PORT.
Lifesaving
Issued 2 October 1997
Resolved
PROVIDE DOCUMENTATION THAT THE LIFERAFTS AND CO2 CYLINDERS (42 ASHORE FROM FIXED CO2 SYSTEM) ARE SERVICED AND PROPERLY INSTALLED ON BOARD PRIOR TO DEPARTURE FROM PORT.
Documentation
Issued 17 August 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Fire Fighting
Issued 17 August 1994
Resolved
PROVIDE DOCUMENTATION OF UP TO DATE FOAM ANALYSIS ON BOARD PRIOR TO RETURN TO U.S. WATERS.
Deck/Cargo
Issued 17 August 1994
Resolved
REPLACE/RENEW THE FLAME SCREEN (NO LESS THAN 30X30 MESH) ON THE COMMON RISER VENT MAST.
Deck/Cargo
Issued 17 August 1994
Resolved
PROVE PROPER OPERATION OF THE IGS INSTRUMENT AIR FAILURE ALARM.
Deck/Cargo
Issued 17 August 1994
Resolved
PROVE PROPER OPERATION OF THE IGS FIXED OXIGEN ANALYZER AND CALIBRATION OF SAME PRIOR TO RETURN TO U.S. WATERS.
Engineering
Issued 17 August 1994
Resolved
MAKE PROPER REPAIRS TO AND PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR 15 PPM ALARM/AUTOMATIC STOPPING DEVICE.
Documentation
Issued 17 August 1994
Resolved
PROVIDE COPY OF SAFEY EQUIPMENT CERTICATE ENDORSEMENT FOR EXTENSION PRIOR TO DEPARTING THE PORT OF ST. CROIX.
Navigation
Issued 1 July 1993
Resolved
PROVIDE SERVICING TECHNICIANS REPORT UPON COMPLETION AND OPERATION OF RADARTO MARINE INSPECTION OFFICE._x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 20 May 1992
Resolved
REPAIR MINOR LEAK ON DRAIN MANIFOLD OF DECK WATER SEAL AND PROVIDE COPY OF SATISFACTORY REPAIR SURVEY FROM CLASS SOCIETY. THIS REQUIREMENT MAY BE SATISFIED BY FAX, AND MUST BE COMPLETED PRIOR TO RETURNING TO U.S. WATERS.
Fire Fighting
Issued 1 December 1986
Resolved
RENEW THE ISOLATION VALVE TO THE NO. 2 FOAM MONITOR. VALVE LOCATED BY MONITOR. TO BE COMPLETED PRIOR TO NEXT US PORT CALL.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.