MAURY USCG vessel records Sign in
← All vessels

JACK D

JACK D is a 1986 tank ship. The Coast Guard has recorded 60 inspections since 1986, most recently in January 2007, along with 35 deficiencies and 4 operational controls.

Records from 1986 to 2007. Most recent: inspection, 17 January 2007.

Built
1986
Last inspected
17 January 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7915632 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
275744
Flag
BAHAMAS, THE
—
Maury page id
psix-275744

Inspections, by type

…with no type recorded42
Years with a record 22 calendar years (1986–2007)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it31108 - Regulatory (Subpart C or D), Net Ton
122587 - Displacement, Ton
98358 - Dead Weight, Ton
59850 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 60

17 January 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2857224
14 March 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2602536
14 March 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2611023
13 March 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2601727
10 March 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2600250
7 October 2005 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2509817
5 May 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2060118
21 April 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2049156
20 April 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2048415
3 June 2003 Certificate of Compliance · Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1805438
21 January 2003 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1733097
25 May 2002 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1617924
13 August 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 292623
13 August 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 757001
12 August 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 209462
19 March 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 288079
19 March 2001 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1061257
24 March 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 275725
1 February 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 274118
1 February 2000 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 814901
4 April 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 427314
2 February 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 425226
8 August 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 418950
10 October 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 408583
2 October 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 408645
2 October 1997 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1110804
25 September 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 757578
24 September 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 191901
28 March 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 402048
16 January 1997 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 758661
15 January 1997 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 191896
12 October 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 396102
15 November 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 384980
28 August 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 382084
16 April 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 376978
22 August 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 871246
17 August 1994 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 369398
17 August 1994 Tank Vessel Examination · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1179869
1 April 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 445732
1 July 1993 MARPOL Annex I Examination · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1157430
9 January 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 355510
14 September 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261490
3 September 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 668013
18 August 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 530489
10 August 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 116608
20 May 1992 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 958797
19 May 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 343877
19 May 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1229937
29 September 1990 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 444539
15 March 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 335974
15 March 1990 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 923935
12 December 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 478027
11 March 1989 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 891191
7 September 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 524610
5 March 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 321677
5 March 1988 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1033365
1 December 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 510304
29 June 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 519822
1 December 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 313104
1 December 1986 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1022914

Deficiency record · 35

Deck/Cargo › Mooring/Anchoring › Winch
Issued 7 October 2005 Resolved
ALL 3 MOORING WINCHES HYDRAULIC PUMPS ARE LEAKING AT SEALS, CAUSING ACCUMILATION. TO THE SATISFACTION OF THE ADMINISTRATION.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 November 2005
Resolved 10 March 2006
Resolution: Received Class report stating that Class is now aware and will ensure repairs are made.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Electric Bonding
Issued 7 October 2005 Resolved
SEVERAL PIPE CONNECTIONS, FLANGES, BRACKETS AND OR GROUNDING STRAPS ARE SEVERLY WASTED AND WORN OR BROKEN ON CARGO LINE ON DECK.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 November 2005
Resolved 10 March 2006
Resolution: Received Class report stating that repairs have been made.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 October 2005 Resolved
CONDUIT FOR ELECTRICAL CABLES ON CARGO DECK HAS EXTENSIVE WASTAGE.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 November 2005
Resolved 10 March 2006
Resolution: Received Class report stating that repairs have been made
Fire Fighting › Fire Hoses › Condition
Issued 7 October 2005 Resolved
FIRE HOSE IN ENGINE ROOM PUNCTURED.
Condition: Improper/Lack of Maintenance
Due 7 October 2005
Resolved 7 October 2005
Resolution: REPLACED HODE ON SCENE.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 7 October 2005 Resolved
HYDRAULIC PIPE TO #5 CARGO HATCH BROKEN.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 October 2005
Resolved 10 March 2006
Resolution: Received Class report stating repairs have been made.
Deck/Cargo › Ballast › Piping
Issued 7 October 2005 Resolved
BALLAST WATER PIPING HAS HOLE/WASTAGE ( IN CARGO PUMP ROOM).
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 November 2005
Resolved 10 March 2006
Resolution: Received Class report stating that repairs have been made.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 7 October 2005 Resolved
CARGO PUMP ROOM HAS SEVERAL IMPROPERLY SEALED OR DAMAGED ELECTRICAL CONNECTIONS.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 November 2005
Resolved 10 March 2006
Resolution: Received Class report stating that Class is now aware and will ensure repairs are made.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 7 October 2005 Resolved
CARGO PUMP ROOM HAS EVIDENCE OF SEVERAL CARGO LEAKS IN VACINITY OF PUMPS/ STRAINERS.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 November 2005
Resolved 10 March 2006
Resolution: Received Class report stating that Class is now aware and will ensure repairs are made.
Engineering › Bilge Water Management System › Valve
Issued 7 October 2005 Resolved
BILDGE SYSTEM REACH RODS IN CARGO PUMP ROOM ARE DAMAGED, WASTED AND OR INOPERABLE.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 November 2005
Resolved 10 March 2006
Resolution: Received Class report stating that repairs have been made.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 3 June 2003 Resolved
Vsl was issued a letter of deviation to enter the Port of Corpus Christi with an inoperable primary radar (33CFR 164.35(a)).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2003
Resolution: Rec''d service rpt dated 03JUN03 attesting to sat repairs/operation of radar equipment via fax from agent.
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 25 May 2002 Resolved
Patch on boiler intake to scrubber, inspection plate on scrubber with improper seal. SOLAS 74(Amend) CH II-2 Reg 62.8.I. Show class surveyor report verifying permanent repairs.
Due 25 June 2002
Resolved 18 June 2002
Resolution: Item corrected.
Deck/Cargo › Inert Gas System
Issued 25 May 2002 Resolved
IGS span gas/02 sensing point not located on IGS main line. SOLAS 74(Amend) CH II-2 Reg 62.16.I.2. Show class surveyor report verifying system operation arrangement.
Due 25 June 2002
Resolved 18 June 2002
Resolution: Item corrected.
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 25 May 2002 Resolved
Excessive soot/exhaust leaks from both auxiliary boilers. SOLAS 74(Amend) CH I-Reg II. Show class report on inspection and survey of auxiliary boilers.
Due 15 August 2002
Resolved 18 June 2002
Resolution: Item corrected.
Engineering
Issued 25 May 2002 Resolved
Possible leak (water) from #steam turbine/#cargo pumps. SOLAS 74(Amend) Reg 56/CH I-Reg II. Show class surveyor report verifying gas tight arrangement between pumproom/engine room.
Due 25 June 2002
Resolved 18 June 2002
Resolution: Item corrected.
Engineering
Issued 25 May 2002 Resolved
Excessive water/steam leaks on all cargo pump steam turbines. SOLAS 74(Amend) CH I-Reg II/CH II-I Reg 26. Show class surveyor report verifying repairs/operation.
Due 25 June 2002
Resolved 18 June 2002
Resolution: Item corrected.
Engineering › Compressed Air System (control)
Issued 25 May 2002 Resolved
Air compressor in engine room with portable air duct for cooling. SOLAS 74(Amend) CH I-Reg II/CH II-I Reg 26. Submit class surveyor report verifying proper operation. LEGACY COMPONENT DESC: Compressor
Due 25 June 2002
Resolved 18 June 2002
Resolution: Item corrected.
Lifesaving
Issued 1 February 2000 Resolved
STARBOARD LIFEBOAT FORWARD, LOWER WHEEL/ROLLER IS MISSING RUBBER. REPLACE TO SATISFACTION OF CLASS BY 01MAR00. FAX COPY TO USCG.
Condition: Unknown
Due 14 March 2000
Resolved 14 March 2000
Deck/Cargo
Issued 2 February 1999 Resolved
PRIOR TO NEXT U.S. PORT, MAKE PERMANENT AND PROPER REPAIRS TO THE FIXED OXYGEN ANALYZER (INERT GAS SYSTEM), AND SHOW PROPER OPERATION INCLUDING PROPER CALIBRATION OF METER. VESSEL IS TO ENSURE ALL CARGO TANKS REMAIN PROPERLY INERTED AND A LOGBOOK KEPT OF ALL TANK O2 READINGS OBTAINED.
Condition: Unknown
Due 7 April 1999
Resolved 7 April 1999
Documentation
Issued 2 February 1999 Resolved
VESSEL NOT PROPERLY MANNED IN ACCORDANCE WITH SAFE MANNING CERTIFICATE (C/ELICENSE EXPIRED). PRIOR TO DEPARTURE FROM THE PORT OF NEW ORLEANS, ENSURE THE VESSEL IS PROPERLY MANNED, AND A PROPERLY LICENSED C/E IS ON BOARD.
Condition: Unknown
Due 3 February 1999
Resolved 4 February 1999
Lifesaving
Issued 2 February 1999 Resolved
PROVIDE PROPER PHONE LIST NUMBERS FOR PHONE IN STEERING GEAR SPACE.
Condition: Unknown
Due 2 February 1999
Resolved 4 February 1999
Deck/Cargo
Issued 2 October 1997 Resolved
CARGO PUMP #1 IS TO BE TAKEN OUT OF SERVICE UNTIL THE EMERGENCY SHUTDOWN SYSTEM IS REPAIRED AND VERIFIED.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Deck/Cargo
Issued 2 October 1997 Resolved
REPAIR/ PROVIDE THE AUTOMATIC SHUTDOWN DEVICE FOR LOSS OF NORMAL WATER SUPPLY TO THE DECK WATER SEAL IAW 46 CFR 32.53-70(B)(3) PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Deck/Cargo
Issued 2 October 1997 Resolved
REPAIR THE ENGINE ROOM/ CONTROL ROOM ALARMS FOR THE CARGO PUMP EMERGENCY SHUTDOWN SYSTEM PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Construction/Loadline
Issued 2 October 1997 Resolved
REPAIR AND PROVE PROPER OPERATION OF THE 15 PPM OILY WATER SEPERATOR ALARM PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 2 October 1997 Resolved
PROVIDE DOCUMENTATION THAT THE LIFERAFTS AND CO2 CYLINDERS (42 ASHORE FROM FIXED CO2 SYSTEM) ARE SERVICED AND PROPERLY INSTALLED ON BOARD PRIOR TO DEPARTURE FROM PORT.
Condition: Unknown
Due 5 October 1997
Resolved 6 October 1997
Documentation
Issued 17 August 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 August 1994
Resolved 17 August 1994
Fire Fighting
Issued 17 August 1994 Resolved
PROVIDE DOCUMENTATION OF UP TO DATE FOAM ANALYSIS ON BOARD PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 19 August 1994
Resolved 22 September 1994
Deck/Cargo
Issued 17 August 1994 Resolved
REPLACE/RENEW THE FLAME SCREEN (NO LESS THAN 30X30 MESH) ON THE COMMON RISER VENT MAST.
Condition: Unknown
Due 19 August 1994
Resolved 22 September 1994
Deck/Cargo
Issued 17 August 1994 Resolved
PROVE PROPER OPERATION OF THE IGS INSTRUMENT AIR FAILURE ALARM.
Condition: Unknown
Due 19 August 1994
Resolved 22 September 1994
Deck/Cargo
Issued 17 August 1994 Resolved
PROVE PROPER OPERATION OF THE IGS FIXED OXIGEN ANALYZER AND CALIBRATION OF SAME PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 19 August 1994
Resolved 22 September 1994
Engineering
Issued 17 August 1994 Resolved
MAKE PROPER REPAIRS TO AND PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR 15 PPM ALARM/AUTOMATIC STOPPING DEVICE.
Condition: Unknown
Due 19 August 1994
Resolved 22 September 1994
Documentation
Issued 17 August 1994 Resolved
PROVIDE COPY OF SAFEY EQUIPMENT CERTICATE ENDORSEMENT FOR EXTENSION PRIOR TO DEPARTING THE PORT OF ST. CROIX.
Condition: Unknown
Due 19 August 1994
Resolved 22 September 1994
Navigation
Issued 1 July 1993 Resolved
PROVIDE SERVICING TECHNICIANS REPORT UPON COMPLETION AND OPERATION OF RADARTO MARINE INSPECTION OFFICE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Deck/Cargo
Issued 20 May 1992 Resolved
REPAIR MINOR LEAK ON DRAIN MANIFOLD OF DECK WATER SEAL AND PROVIDE COPY OF SATISFACTORY REPAIR SURVEY FROM CLASS SOCIETY. THIS REQUIREMENT MAY BE SATISFIED BY FAX, AND MUST BE COMPLETED PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Fire Fighting
Issued 1 December 1986 Resolved
RENEW THE ISOLATION VALVE TO THE NO. 2 FOAM MONITOR. VALVE LOCATED BY MONITOR. TO BE COMPLETED PRIOR TO NEXT US PORT CALL.
Condition: Unknown
Due 1 December 1986
Resolved 1 December 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.