BLACK BEAR is a 1948 school ship. The Coast Guard has recorded 61 inspections since 1988, most recently in June 2025, along with 54 deficiencies and 1 operational control.
Records from 1988 to 2025. Most recent: operational control imposed, 3 June 2025.
- Built
- 1948
- Last inspected
- 3 June 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 54 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
WTE4208
275778
Flag
UNITED STATES
—
Maury page id
psix-275778
Inspections, by type
…with no type recorded6
Years with a record
34 calendar years (1988–2025)
The 61 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the School Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it80 - Simplified, Gross Ton
58 - Simplified, Net Ton
58 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 61
3 June 2025
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8149784
25 June 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7939106
26 June 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7721824
10 May 2023
Deficiency Check · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7685408
11 August 2022
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7501089
24 June 2021
Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7235202
28 July 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7018528
23 July 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6759331
31 October 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6570305
17 May 2018
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6417193
31 July 2017
Annual Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6226281
16 August 2016
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5966575
18 August 2015
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5220402
28 August 2014
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4887008
13 June 2012
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4337696
15 August 2011
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4116742
6 November 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3350099
24 September 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3065206
28 August 2006
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2758367
7 September 2005
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2478873
6 May 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2351069
5 April 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2326810
16 December 2004
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2260790
15 December 2004
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2259862
14 September 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2158133
3 October 2002
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1683784
23 August 2002
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1654397
7 August 2001
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1423622
18 September 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1373229
19 August 1999
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1361062
19 August 1998
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1130874
21 November 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1466486
24 October 1997
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1115082
25 September 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1418253
18 June 1997
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 776333
18 October 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 848346
20 September 1996
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1374747
23 August 1995
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1188800
14 November 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1174391
16 August 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1178762
15 July 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1179527
31 May 1994
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 861776
8 November 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1157680
16 August 1993
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1153616
30 October 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1242961
18 October 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 961412
14 October 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 957570
18 August 1992
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 847586
18 August 1992
COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1259637
13 April 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1267775
4 November 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 934768
8 August 1990
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 904501
6 September 1989
Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1342592
5 September 1989
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 898571
27 March 1989
Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1040240
18 November 1988
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1206423
9 September 1988
Initial Certification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1040311
1 September 1988
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1044653
31 August 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1041520
16 August 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1345070
31 July 1988
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1039126
Deficiency record · 54
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 June 2025
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. Main engine fuel shutoff assembly failed to close fuel supply valve. Correct prior to carriage of passengers. 46 CFR 182.455(b)(4)
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 3 June 2025
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] missing for secondary means of escape on watertight door forward in engine room and through forward void deck hatch. 46 CFR 185.606
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 3 June 2025
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Emergency broadcast instructions are missing. 46 CFR 184.506
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 June 2025
Resolved
Each vessel must be marked as required by part 67, subpart I, of this chapter. : The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel name not marked on bows and hailing port not visibly marked on stern. 46 CFR 185.602(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2024
Resolved
The marine inspector shall examine all accessible parts of the vessel's hull, machinery, and equipment to be assured that they are in satisfactory condition. The starboard generator raw water discharge piping was leaking at the elbow closest to the bulkhead. Repair issue to the satisfaction of the Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 June 2023
Resolved
Piping used in a vital system must: Be composed of ferrous materials. Temporary repair found on underside of fire pump intake piping just before the manifold leading into the fire pump. Submit repair details for making a permanent repair to fire pump piping. Alternatively, provide three, 2.5 gallon fire buckets onboard as a fire pump is not required on this vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 26 June 2023
Resolved
Each survival craft must be: secured to the vessel by a painter with a float free link permanently attached to the vessel. The link must be constructed essentially as shown in figure 160.073–10. The link must be formed from a single saltwater corrosion-resistant wire. A loop at least 50 mm (2 in.) in diameter must be provided at each end of the wire. Each loop must be permanently secured…. The breaking strength of each link must be between: 450 N (100 lb.) and 600 N (134 lb.) for links intended for life floats and buoyant apparatus of 10 persons and less capacity….. Float free link on life float is insufficient, replace with properly rated wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 June 2023
Resolved
A voltmeter and an ammeter shall be provided that can be used for measuring voltage and current of each generator that is in operation…..Repair or replace starboard generator ammeter.
46 CFR 183.10-5(g) Old T
09 - Working and Living Conditions › 092 - Working Conditions › Entry dangerous spaces
Issued 26 June 2023
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.”…. Entrance to engine room space does not have a CO2 warning placard, install placard in a visible location on the exterior area of entry into engine room space.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 26 June 2023
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: “EMERGENCY EXIT, KEEP CLEAR”. Emergency escape in forward portion of engine room not marked.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 June 2023
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coat Guard officials upon request. Test records for empolyees were not available onboard and crewmembers onboard were not listed under document showing which employees were subject to drug tests.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 11 August 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including the following: Operational test of all emergency electrical systems. General alarm did not sound despite it being on a closed emergency circuit at the time of the inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 August 2022
Resolved
Except as noted in paragraph (d) of this
section, the data shall be stamped directly on the pressure vessel. The data shall be legibly stamped and shall not be obliterated during the service life of
the pressure vessel. The data plate that meets the requirements of 46 CFR 54.10-20(a) regulations for the pressure vessels (air receivers) is missing.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 23 July 2019
Resolved
Exhaust piping shall be led to the point of escape with a minimum number of bends and elbows. It shall be gas-tight throughout its length and shall be properly supported by non-combustible hangers or blocks. MIs onboard and at least one crew member observed an apparent exhaust leak in the engine room while both generators and the main engine were running. Identify and prove that the engine room exhaust piping is gas-tight.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 July 2019
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Drills and training logs were not kept up to date. Logs were updated in the presence of the attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 October 2018
Resolved
46CFR 183.05-20 - Batteries shall be effectively screened by a cage or simliar structure to minimize the danger of accidental spark through dropping a metal object across terminals. Numerous storage conatiners of ships batteries not screened or covered as required.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 October 2018
Resolved
46CFR 176.25-25 - The fire pump shall be tested and teh fire hose shall be satisfactorily subjected to the available fire pump pressure. Fire hose tear witnessed during test. Replacement hose required.
Documentation › Logs/Records › Drug Test Records
Issued 2 August 2017
Resolved
Complete 2017 DAPI Audit 46CFR185.210
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 August 2017
Resolved
Provide proper operation of float light on life float. 46CFR180.710
Engineering › Steering Gear System › Hydraulic Hose
Issued 28 August 2014
Resolved
Properly secure hydraulic hose bracket for steering gear. 46CFR182.610
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 28 August 2014
Resolved
Replace raw water cooling hose on MDE with approved type. 46CFR182.200
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 August 2011
Resolved
Install lagging on both generator exhaust elbows
Construction/Loadline › Structures › Superstructure
Issued 22 August 2011
Resolved
Replace cracked window glass in pilothouse.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 August 2011
Resolved
Provide proof of acceptable navigational lights.
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 August 2011
Resolved
Properly label lifejacket stowage compartment
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 August 2011
Resolved
Replace lifefloat waterlight battery.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 November 2008
Resolved
Prove proper operation of the vessels anchor light.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 7 September 2005
Resolved
Provide lifesaving inspection log.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 16 December 2004
Resolved
Provide plans for location and equipment specifications to install approved Lifesaving appliances, i.e., Life float or IBA, in accordance with stowage requirements of 46 CFR180.130 and 46 CFR180.137 and the equipment requirements of 46 CFR 180.175. Such appliance must have at least 50% capacity of the total persons allowed onboard (15).
Lifesaving › Hand Flares › Expired
Issued 14 September 2004
Resolved
Replace expired day & night flares.
Lifesaving › Hand Flares › Storage
Issued 14 September 2004
Resolved
Label flare containers with the words Distress Signals.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 September 2004
Resolved
Provide burn cream for first aid kit.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 September 2004
Resolved
Apply retroreflective tape to the STBD Life Ring.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 September 2004
Resolved
Replace bulb in the lower towing light on mast.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 October 2002
Resolved
Replace all expired medications and saline solutions. LEGACY COMPONENT DESC: First Aid Kit
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 3 October 2002
Resolved
115V AC panel located in fore peak crew space: Replace tape with blank circuit breaker and label circuit breaker. LEGACY COMPONENT DESC: Panelboard
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 3 October 2002
Resolved
Anchor was not mounted or secured in aft well deck. Secure anchoring in order to prevent it from becoming adrift in heavy seas or wx. LEGACY COMPONENT DESC: Anchor
Construction/Loadline
Issued 18 September 2000
Resolved
INSTALL HIGH LEVEL BILGE ALARMS IAW 46 CFR 182.530 PRIOR TO 18OCT00 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Construction/Loadline
Issued 25 September 1997
Resolved
REPAIR CRACKED WELDS (3) IN TRANSVERSE MEMBER LOCATED IN CREW'S COMPARTMENT.
Engineering
Issued 20 September 1996
Resolved
CLEAN FLAME SCREEN FOR FUEL OIL TANK VENT TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Fire Fighting
Issued 20 September 1996
Resolved
PROVIDE EVIDENCE OF LATEST HYDRO TEST OF FIXED CO2 SYSTEM FLEX LOOPS TO THESATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Construction/Loadline
Issued 20 September 1996
Resolved
FREE UP, ADJUST AND PROVE PROPER OPERATION OF CREW ACCOMODATION SCUTTLE DOGS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Navigation
Issued 20 September 1996
Resolved
PROVIDE COPY OF DESIGNATED DECKHAND INSTRUCTION AND INSTRUCTORS (MASTERS) CHECK-OFF LIST INDICATING RESPONSIBILITY FOR VESSEL'S UPDATED CHARTS AND PUBS. THIS TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Construction/Loadline
Issued 20 September 1996
Resolved
INSTALL PROPER SIZE STRAINERS FOR ALL BILGE PIPE SUCTIONS TO THE_x001C_ SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Fire Fighting
Issued 20 September 1996
Resolved
PROVE PROPER OPERATION OF CO2 FIRE SYSTEM SIREN TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO THE CARRAIGE OF PASSENGERS.
Navigation
Issued 20 September 1996
Resolved
PROVIDE CURRENT COMPASS DEVIATION CHART TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Navigation
Issued 20 September 1996
Resolved
PROVE PROPER OPERATION OF BRIDGE RADAR TO THE SATISFACTION OF THE ATTENDINGMARINE INSPECTOR.
Documentation
Issued 23 August 1995
Resolved
Prior to operating more than 1000 feet from shore, demonstrate to the satisfaction of the cognizant OCMI that a valid FCC certificate is posted.
Documentation
Issued 16 August 1994
Resolved
PRIOR TO OPERATING MORE THAN 1000 FEET FROM SHORE, DEMONSTRATE TO THE SATISFACTION OF THE COGNIZANT O.C.M.I THAT A VALID FCC CERTIFICATE IS POSTED.
Documentation
Issued 31 May 1994
Resolved
PROVIDE A COPY OF HULL GUAGING REPORT FOR VESSEL'S FILES.
Engineering
Issued 18 August 1992
Resolved
OPEN AIR RECEIVERS FOR INSPECTION OR HYDROTEST, IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Engineering
Issued 9 September 1988
Resolved
VESSEL'S PORT (2) AND STARBOARD (2) FUEL OIL TANKS SHALL BE CONVERTED TO BALLAST TANKS; ALL ASSOCIATED PIPING SHALL BE DISCONNECTED FROM THE FUEL SYSTEM.
Engineering
Issued 9 September 1988
Resolved
VESSELS REMAINING FUEL OIL TANK (CENTER FORWARD) SHALL HAVE VALVES INSTALLED IN THE FILL, HIGH AND LOW SUCTION LINES; REMOTELY OPERATED REACH RODS SHALL BE INSTALLED FOR EACH.
Documentation
Issued 9 September 1988
Resolved
PLANS DETAILING THE PROPOSED CONVERSION OF THE FUEL OIL SYSTEM SHALL BE SUBIMTTED TO [name withheld] FOR REVIEW AND APPROVAL.