← All vessels
BARBARA LEE
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named BARBARA LEE
BARBARA LEE is a 1986 passenger vessel (inspected). The Coast Guard has recorded 115 inspections since 1986, most recently in January 2026, along with 231 deficiencies, 1 operational control and 11 casualty investigations between 2005 and 2025.
Records from 1986 to 2026. Most recent: inspection, 13 January 2026.
- Built
- 1986
- Last inspected
- 13 January 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Inspections
- 115
- Deficiencies
- 231 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 11 investigations · 2005–2025
Identity
907707
WDJ6693
275784
Flag
UNITED STATES
367999290
Maury page id
psix-275784
Inspections, by type
…with no type recorded26
Years with a record
38 calendar years (1986–2026)
The 115 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)85.0 ft × 30.0 ft × 6.1 ft
Registered tonnagegross 94 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPATTI SHIPYARD INC · PENSACOLA · built 1986
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSANFORD, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
63 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ6693MMSI 367999290 · active · compulsorily equipped · granted 18 July 2017, expires 18 July 2027
WTS2246MMSI 367142920 · expired · compulsorily equipped · granted 3 October 2006, cancelled 18 February 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 115
13 January 2026
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8295952
4 January 2026
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8297132
16 October 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8253756
4 October 2025
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8270887
5 March 2025
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8090218
10 January 2025
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8070490
17 June 2024
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7936362
16 June 2024
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7953328
1 February 2024
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7861386
14 December 2023
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7839092
6 December 2023
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7835837
6 December 2023
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7835990
14 November 2023
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7825155
16 August 2023
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7786273
6 June 2023
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7705014
5 December 2022
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7597864
17 August 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7536665
12 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7431251
30 November 2021
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7359583
8 December 2020
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7108383
20 October 2020
Administrative Inspection · Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7072297
3 October 2019
MTSA Verification · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6826752
3 August 2019
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6774885
23 October 2018
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6566371
9 October 2018
Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6558495
1 August 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6513803
8 December 2017
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6320949
3 November 2017
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6298975
22 August 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6247505
6 March 2017
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6099457
14 November 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6041539
12 February 2016
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5820749
9 November 2015
DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5761084
12 December 2011
Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4207995
29 August 2011
Drydock Exam · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4129843
20 January 2011
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3929724
19 January 2011
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3929877
10 January 2011
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3923838
19 December 2010
Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3907300
11 December 2010
Type not recorded
No type recorded · Station Ponce De Leon Inlet · USCG Southeast District (CGD-SE) · Activity 3909463
10 December 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3908731
10 December 2010
Damage Survey · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3909418
7 December 2009
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3644334
27 October 2008
Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3352007
10 May 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3203348
9 May 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3203328
2 January 2008
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3123787
17 November 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3105049
10 September 2007
Examination of Repairs · COI Inspection · MTSA Verification · Hull Examination · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3054299
19 July 2007
Drydock Extension
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3019362
22 September 2006
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2784865
22 August 2005
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2470848
22 August 2005
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2471143
21 August 2005
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2470706
5 August 2005
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2448980
19 November 2004
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2246009
25 October 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2225520
8 July 2004
MTSA Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2114969
29 October 2003
Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1929738
22 August 2003
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1867430
8 May 2003
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1788494
19 September 2002
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1668149
7 May 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1614583
22 October 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1399731
14 August 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1472285
3 May 2001
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1062375
31 October 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1449391
22 November 1999
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 809779
4 October 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1404841
12 July 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1436259
2 November 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1451385
29 November 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 166578
17 November 1997
Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1364600
30 September 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 665311
3 September 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 785491
12 August 1997
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1364598
5 August 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 84701
20 June 1997
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1112025
1 February 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 48883
15 October 1996
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1433109
7 March 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 764161
2 March 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 196694
16 October 1995
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1193555
1 August 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 73261
1 August 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 227348
12 July 1995
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1188402
6 December 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 834550
17 October 1994
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1179298
19 November 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1156074
1 November 1993
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 848412
27 May 1993
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 837433
2 November 1992
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1134554
4 February 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 179155
5 December 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 954424
4 November 1991
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 942359
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1249267
8 August 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1246472
1 August 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 935789
10 June 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1308464
11 December 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 923851
5 November 1990
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1217482
4 January 1990
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1219870
13 November 1989
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 998441
14 November 1988
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 893225
8 August 1988
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1038476
7 March 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1027526
30 December 1987
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1318058
10 December 1987
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1003443
23 November 1987
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1027801
5 May 1987
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1331085
13 February 1987
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1308893
30 January 1987
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1014341
14 January 1987
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1006758
2 December 1986
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1023685
26 November 1986
Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1023121
Deficiency record · 231
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 January 2026
Resolved
Each life jacket must be marked with Type I retro-reflective material approved in accordance with § 164.018 in sub-chapter Q of this chapter, or other standard specified by the Commandant. 21 child life jackets need to have reflective tape replaced. Total children allowed reduced to 15.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 January 2026
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Letters and numbers must be at least 50 millimeters (2 inches) high.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 January 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to:Protect passengers, crew, other persons, and the vessel from electrical hazards caused by or originating in electrical equipment, and electrical shock. Install proper electrical mating in front of electric switchboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel is incapable of operating in astern propulsion due to an undiagnosed mechanical issue. Rapier to the satisfaction of a USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 December 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements. Five boards on the stbd paddle wheel outboard side have dings and chips from allision. Replace in kind.
46 CFR 119.200
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 November 2023
Resolved
A vessel must carry one floating waterlight unless it is restricted to daylight only operation. The battery in the waterlight was expired.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 November 2023
Resolved
A self propelled vessel 65 feet or greater in commercial service must have a class A AIS. The 5 year deviation from AIS requirement has expired and installation of an AIS is required.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 June 2023
Resolved
Emergency exits shall be clearly marked "EMERGENCY EXIT, KEEP CLEAR" on both sides of the escape door. Emergency escape was not posted on the outside of the door from the engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2022
Resolved
All electrical equipment and circuits must be clearly marked and identified. Electrical panel in the galley on the stbd side is mislabeled/not clearly marked. Clearly mark panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. Light cover in the galley on the stbd side is broken. Replace broken light cover.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2022
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew spaces located below the main deck. Emergency light inoperable in "girl's side" storage area. Prove proper operation of emergency light.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2022
Resolved
All cable and wire must: Be installed with metal supports spaced not more than 24 inches apart. Hanging wires in "girl's side" storage area not properly supported. Properly support hanging wires.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 December 2022
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel name not fully legible on ring life buoys. Re-stencil vessel name on ring life buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 December 2022
Resolved
Each life jacket must be marked with Type I retroreflective material approved in accordance with § 164.018. Retroreflective material on multiple child lifejackets not serviceable. Renew deteriorated retro material.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 December 2022
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with § 164.018. Retroreflective material on ring life buoys throughout not serviceable. Renew deteriorated retro material.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 December 2022
Resolved
At least one ring life buoy must be fitted with a lifeline. Fitted lifeline on ring life buoy forward of the house is deteriorated. Renew lifeline.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 December 2022
Resolved
A door in a fire control boundary must meet the following requirements: A door must be capable of operation from either side by one person. Galley door will not close. Prove proper operation of door.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 December 2022
Resolved
A-Class bulkheads or decks must be so insulated with approved structural insulation, bulkhead panels, or deck covering. Various structural fire protection missing/damaged/poor material condition in the engine room. Renew damaged structural fire protection.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 December 2022
Resolved
The following spaces must be equipped with a fire detection and alarm system of an approved type that is installed in accordance with part 76 in subchapter H of this chapter: A space containing an internal combustion engine of more than 37.3 kW (50 hp). Heat detector in engine room is inoperable/crew unable to test. Prove proper operation of detector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 December 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Replace missing bolts on aft railing below flagpole. Renew stanchion on flying bridge.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 5 December 2022
Resolved
Watertight doors and watertight hatches must be marked on both sides in clearly legible letters. Escape hatch from galley challenging to open/confusing to operate. Prove proper functioning of hatch.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 5 December 2022
Resolved
Vessel control systems and other miscellaneous systems and equipment required by this part must be suitable for the purposes intended. Prove operation of watertight door indicator on bridge.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 December 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Port side water tank access leaking into storage/workshop area. Repair leak.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2022
Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of 46 CFR 4.06. Alcohol test strips expired. Renew alcohol test strips.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 November 2021
Resolved
The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Repair lagging on the exhaust on starboard generator.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 November 2021
Resolved
The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Repair damper to galley to ensure it is capable of fully closing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 October 2020
Resolved
A voltmeter and an ammeter, which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. The ammeter for both generators was not operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 October 2020
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Oil leaks identified on both generators.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 October 2019
Resolved
Replace wasted grabline on ring buoys on port and starboard bridge wings.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 October 2019
Resolved
Service door (hatch) between galley and storeroom is not operable from both sides. Make door operable from the galley side.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 October 2019
Resolved
Replace broken window on starboard side in upper dining room.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 October 2019
Resolved
Repair wasted gooseneck vent on main deck starboard side under stairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2019
Resolved
Remove or permanently protect exposed wires IWO upper deck A/C units and upper sevice station overhead.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 October 2019
Resolved
Provide alcohol test kits.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 October 2019
Resolved
Post stability letter and establish a waste management plan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 October 2018
Resolved
Pack bilge pump seal.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 9 October 2018
Resolved
Provide guard for rotating machinery on bilge pump.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 3 November 2017
Resolved
Provide 10 adult size type I PFD's. Persons allowed onbaord reduced to 350 until provided.
Documentation › Certificates/Documents › FCC SSL
Issued 3 November 2017
Resolved
Provide FCC Safety Certificate.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 November 2017
Resolved
Renew broken windows.
Engineering › Lubricating Oil Service System › Gauge
Issued 14 November 2016
Resolved
Prove proper operation of port MDE oil pressure gauge.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 14 November 2016
Resolved
Provide 1st aid/CPR training for 50% of crew.
Construction/Loadline › Penetrations › Pipe Flange
Issued 14 November 2016
Resolved
Remove and properly repair the stbd side aft stern side shell in the rudder room.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 November 2016
Resolved
Provide cover for light in galley port side.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 November 2016
Resolved
Label breakers in galley breaker box.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 November 2016
Resolved
Repair / renew electric panelboard.
Electrical › Electrical Distribution System (service) › Switch
Issued 14 November 2016
Resolved
Install switch for ammeter.
Electrical › Electrical Distribution System (service) › Switch
Issued 14 November 2016
Resolved
Properly label switches on bridge panel.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 9 November 2015
Resolved
Prove proper operation of port engine oil pressure gauge.
Construction/Loadline › Structures › Deck Plating
Issued 9 November 2015
Resolved
Properly stuff hole in deck 3 over junction box on deck 2.
Electrical › Electrical Distribution System (service) › Conductor
Issued 9 November 2015
Resolved
Properly secure conduit on port aft spud.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 9 November 2015
Resolved
Vessel restricted to 325 total persons until additional 35 PFD's are provided.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 20 December 2010
Resolved
PROVIDE AND ENSURE THAT ALL LIFE JACKETS HAVE PROPER RETROREFLECTIVE MATERIAL.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 20 December 2010
Resolved
REPLACE AND RENEW FIRE DAMPER CABLE IN ENGINE ROOM PORTSIDE.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 December 2010
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING IN GALLEY AREA.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 December 2010
Resolved
RE-LABEL LIFE JACKET SOTRAGE CONTAINER WITH "10 ADULT LIFE JACKETS".
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 20 December 2010
Resolved
CLEAN WATER AND DEBRIS THAT HAS COLLECTED IN THE BOTTOM OF BATTERY BOX
Construction/Loadline › Hull › Bottom Plating
Issued 10 December 2010
Resolved
Due to vsl grounding, conduct survey of vsl's bottom shell for damage. POC was instructed to haul vsl or conduct underwater dive survey.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 10 December 2010
Resolved
Provide proof of Drug and Alcohol Testing for captain and crew on duty 10Dec2010 when vsl grounded.
Operations/Management › Drug and Alcohol Testing › Testing, Reasonable Cause
Issued 10 December 2010
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Personnel › Certificates/Documents/Licenses › License, Master
Issued 10 December 2010
Resolved
Due to vsl grounding, master was instructed to submit to sobriety test. Master (Gerald wade Ross) declined, he then was informed that his master's license was temporarily suspended pending a Coast Guard investigation.
Engineering › Thrusters › Strut
Issued 27 October 2008
Resolved
Repair broken spokes (3) on stbd outboard paddlewheel.
Engineering › Thrusters › Strut
Issued 27 October 2008
Resolved
Repair broken spoke on the port outboard paddlewheel.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 27 October 2008
Resolved
Provide emergency light for stairwell 2nd deck.
Documentation › Logs/Records › Drug Test Records
Issued 21 September 2007
Resolved
Provide drug program consortium testing statistics for CY2006.
Documentation › Logs/Records › Drug Test Records
Issued 21 September 2007
Resolved
Provide documentation to prove EAP training for all covered employees per 46CFR16.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 September 2007
Resolved
Provide lifesaving equipment maintenace record logbook per 46 CFR 122.702.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 21 September 2007
Resolved
Relabel lifejacket storage containers on the 3rd deck, stbd side and change child lifejacket count to reflect actual number of child lifejackets.
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 21 September 2007
Resolved
Provide latch on aft side of fire damper in galley.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 21 September 2007
Resolved
Relocate BII portable fire extinguisher from 1st deck to inside the engineroom.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 September 2007
Resolved
Provide GFI's for bar and galley.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 21 September 2007
Resolved
Provide means of latching 2nd deck port aft double fire doors and 1st deck men's head door.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 21 September 2007
Resolved
Update fire control plan to reflect 1sr deck forward 4 of 5 fire station.
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 21 September 2007
Resolved
Replace missing structural fire protection insulation in the beverage storage rooms as marked. In addition, provide insulation to A15 standard in engineroom. All deck longitudinals/framing & inboard blkhds (12 inches from ceiling) where fitted must be CG approved insulation. Recommend addressing concerns/receiving proposal from a naval architect. Reduce mid-void combustibles to below .5 lb sq ft
Engineering › Generator (propulsion-electric) › Generator Voltage Regulator Circuitry
Issued 21 September 2007
Resolved
Repair 140kW port generator. In lieu of the port generator, a mobile 100kW generator may be used.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 21 September 2007
Resolved
Stencil/label engineroom means of escape as "Emergency Exit, Keep Clear."
Electrical › Electrical Distribution System (service) › Switchboard
Issued 21 September 2007
Resolved
Repair manual voltage control knobs on main switchboard.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 21 September 2007
Resolved
Replace air intake housing on port main engine.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 September 2007
Resolved
Provide two light covers; one in the lazarette and one in the engine room.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 21 September 2007
Resolved
Repair hydraulic oil leaks in the engine room.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 21 September 2007
Resolved
Remove all absorbent rags from engine room bilges.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 21 September 2007
Resolved
Install junction box for loose wired connection in lazarette and provide junction box cover for existing box.
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 21 September 2007
Resolved
Insert fire stop for beverage deck penetration on 1st deck. Also provide fire stop specification prior to installing to ensure CG approved and adequate for A15 boundary.
Construction/Loadline › Structures › Superstructure
Issued 21 September 2007
Resolved
Crop and renew waster steel around windows as necessary.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 21 September 2007
Resolved
Repair exhaust leak in stbd engine exhaust piping.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 21 September 2007
Resolved
Remove stagnant water from galley and other food/beverage servicing areas. General cleanliness of these areas leaves much to be desired.
Electrical › Electric Generation Source (service) › Generator
Issued 22 August 2005
Resolved
Have both generator windings clean and inspected. The STBD GENSET is coated with oil and dirt and the PORT was covered with dirt. Both filters on GENSET housings were completely blocked with dirt and oil. When filters were removed, a large amount of oil and dirt build-up was noted. Installed new filters until GENSET's can be cleaned.
Engineering › Steering Gear System › Fastener
Issued 22 August 2005
Resolved
Replace steering hydraulic rams as discussed and mounting plate for same on STBD side. POC stated that they have new rams but have not had the time to replace.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 August 2005
Resolved
Replace missing insulation in engine room as discussed. They ordered some more insullation that was thrown out during latest yard period. It's an area of about 3 ft x 3ft located on the PORT side of the AFT engine room BLKHD.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 August 2005
Resolved
Prior to night time operation, replace strobe light. Light broken.
Fire Fighting › Firemans Outfit › Axe
Issued 25 October 2004
Resolved
PROVIDE FIRE AXE IN PILOT HOUSE.
Fire Fighting › Fire Hoses › Connections
Issued 25 October 2004
Resolved
INSTALL SPANNER WRENCH IN AFT MEZZANINE FIRE STATION PRIOR TO CARRIAGE OF PASSENGERS.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 25 October 2004
Resolved
REPAIR STRUCTURAL FIRE PROTECTION IN MID VOID AREA OVERHEAD.
Electrical › Electrical Distribution System (service)
Issued 29 October 2003
Resolved
INSTALL GFI OUTLET BOX UNDER GALLEY DISHWASHER. LEGACY COMPONENT DESC: Outlet Box
Electrical › Lighting (service)
Issued 29 October 2003
Resolved
REPAIR BROKEN LIGHT IN WAY OF GALLEY OVEN. LEGACY COMPONENT DESC: Lighting Fixture
Electrical › Electrical Distribution System (service)
Issued 29 October 2003
Resolved
REPAIR REFRIGERATOR CORD IN GALLEY. LEGACY COMPONENT DESC: Cable
Fire Fighting › Fire Pumps
Issued 29 October 2003
Resolved
REPLACE FIRE PUMP GAUGE. LEGACY COMPONENT DESC: Pressure
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 29 October 2003
Resolved
PROVIDE SAFETY CAGES OVER PULLEY ASSEMBLEY ON BOTH MDE'S. LEGACY COMPONENT DESC: Guard
Engineering › Bilge Water Management System
Issued 29 October 2003
Resolved
REPAIR AUDIBLE ALARM ON HIGH LEVEL BILGE PANEL. LEGACY COMPONENT DESC: Alarm
Engineering › Lubricating Oil Service System
Issued 29 October 2003
Resolved
REPAIR OR REPLACE OIL PRESSURE GAUGES ON BRIDGE. LEGACY COMPONENT DESC: Gauge
Construction/Loadline › Structures
Issued 13 August 2003
Resolved
CROP AND RENEW STARBOARD BOTTOM SUPPORT BEAM FOR PADDLE WHEEL. LEGACY COMPONENT DESC: Paddle Wheel
Construction/Loadline › Hull
Issued 13 August 2003
Resolved
SUBMIT PLATE SUMMARY DETAILING ALL PLATE REPLACEMENT DURING CREDIT DRYDOCK. LEGACY COMPONENT DESC: Bottom Plating
Fire Fighting › Structural Fire Protection - General
Issued 19 September 2002
Resolved
REPAIR WASTED PORTION OF FIRE SCREEN DOOR FROM GALLEY USING ACCEPTABLE IN KIND MATERIAL AS TO MAINTAIN INTEGRITY OF STURCTURAL FIRE PROTECTION CLASSIFICATION. MAKE AVAILABLE SPECS FOR ALL MATERIAL USED FOR REPAIRS. LEGACY COMPONENT DESC: Cooking Area
Engineering › Diesel Engine (auxiliary)
Issued 19 September 2002
Resolved
CLEAN OILY RESIDUE FROM ENGINE ROOM. SUBMIT PROPOSAL FOR CLEANING / REPLACING FIRE RETARDANT INSULATION. LEGACY COMPONENT DESC: Housecleaning
Engineering › Diesel Engine (propulsion-direct drive)
Issued 19 September 2002
Resolved
REPLACE EXHAUST LAGGING ON BOTH MAIN DIESEL ENGINES. LEGACY COMPONENT DESC: Piping (exhaust)
Pollution Prevention/Response › Prevention Equipment
Issued 19 September 2002
Resolved
REPAIR SEWAGE VENT PIPING. LEGACY COMPONENT DESC: Sewage System Piping
Engineering › Diesel Engine (propulsion-direct drive)
Issued 19 September 2002
Resolved
PROPERLY MOUNT HYDRAULIC FILTERS IN ENGINEROOM. LEGACY COMPONENT DESC: FILTERS
Engineering › Diesel Engine (propulsion-direct drive)
Issued 19 September 2002
Resolved
REPLACE HYDRAULIC HOSES TO FILTERS IN ENGINE ROOM. LEGACY COMPONENT DESC: HYDRAULIC LINES
Construction/Loadline › Hull
Issued 19 September 2002
Resolved
REPAIR WASTED DECK PLATES IN COMPARTMENT FORWARD OF GALLEY. . LEGACY COMPONENT DESC: Deck plating
Construction/Loadline › Structures
Issued 8 May 2002
Resolved
Repair PORT engine room ventillation duct BLKHDS prior to completion of next drydock. ( This was issued on 22OCT01 from activity case # 1399731 and cleared by mistake) LEGACY COMPONENT DESC: Machinery Space Opening
Lifesaving
Issued 22 October 2001
Resolved
ADJUST PASSENGER SAFETY ORIENTATION TO MEET CURRENT REGULATIONS.
Construction/Loadline
Issued 22 October 2001
Resolved
REPAIR PORT ENGINE ROOM VENTILLATION DUCT BULKHEADS PRIOR TO COMPLETION OF NEXT DRYDOCK.
Fire Fighting
Issued 22 October 2001
Resolved
INSTALL NON COMBUSTIBLE TRASH CANS THROUGHOUT VESSEL.
Fire Fighting
Issued 22 October 2001
Resolved
REPAIR INSULATION IN ENGINE ROOM AS NEEDED.
Lifesaving
Issued 22 October 2001
Resolved
POST EMERGENCY EVACUATION PLAN AND FIRE CONTROL PLAN IAW 46CFR116.530.
Lifesaving
Issued 22 October 2001
Resolved
PROVIDE EEP TRAINING GUIDE FOR CREW.
Lifesaving
Issued 22 October 2001
Resolved
PROVIDE MAINTENANCE INSTRUCTIONS FOR SURVIVAL CRAFT.
Electrical
Issued 22 October 2001
Resolved
INSTALL ACID RESISTANT BATTERY BOXES IN ENGINE ROOM.
Electrical
Issued 22 October 2001
Resolved
INSTALL BLANK IN GALLEY DISTRIBUTION PANEL.
Fire Fighting
Issued 22 October 2001
Resolved
MAKE PORT ENGINE ROOM VENT AIR TIGHT.
Fire Fighting
Issued 22 October 2001
Resolved
RENEW TO ORIGINAL OR MEET "K" REGULATIONS ON SIX (02 MAIN DECK, 04 01 DECK)D-11 DOORS OR PROVIDE PROFESSIONAL ENGINEERING REPORT STATING CURRENT DOORSARE EQUIVALENT PRIOR TO COMPLETION OF NEXT D/D.
Fire Fighting
Issued 22 October 2001
Resolved
REPAIR GALLEY DOOR FRAME AT BOTTOM.
Fire Fighting
Issued 22 October 2001
Resolved
INSULATE PORT MAIN DECK HVAC STAIRWELL TO A-60.
Fire Fighting
Issued 22 October 2001
Resolved
REPAIR INSULATION ON FWD BULKHEAD OF SERVICE AREA.
Fire Fighting
Issued 22 October 2001
Resolved
REPAIR/REPLACE INSULATION IN PORT ENGINE ROOM VENT SHAFT.
Fire Fighting
Issued 22 October 2001
Resolved
REPAIR REMOTE GALLEY EXHAUST FAN SHUT OFF.
Lifesaving
Issued 22 October 2001
Resolved
SECURE ALL GALLEY EQUIPMENT FOR SEA.
Lifesaving
Issued 22 October 2001
Resolved
INSTALL TWO PADDLE ON EACH LIFEFLOAT.
Lifesaving
Issued 22 October 2001
Resolved
POST STATION BILL.
Electrical
Issued 22 October 2001
Resolved
INSTALL WET LOCATION OUTLETS IN GALLEY, WET BARS AND ICE MACHINE DRAIN SUMP.
Engineering
Issued 22 October 2001
Resolved
REPLACE PORT FLEX FUEL LINE.
Lifesaving
Issued 22 October 2001
Resolved
REPLACE SEA PAINTER ON EACH LIFESAVING STACK.
Lifesaving
Issued 22 October 2001
Resolved
PLACE SLATS BETWEEN EACH LIFEFLOAT/BA.
Construction/Loadline
Issued 14 August 2001
Resolved
Renew forepeak hatch/coaming.
Engineering
Issued 14 August 2001
Resolved
Provide condition report from hydraulic propulsion motor overhaul.
Construction/Loadline
Issued 14 August 2001
Resolved
Provide vsl worklist.
Engineering
Issued 14 August 2001
Resolved
Repair cracked welds (gouge/reweld) at base of paddle wheel spokes and renew wasted sections of spokes as indicated.
Accommodation/Occupational Safety
Issued 14 August 2001
Resolved
Repair vent cover port side galley exhaust (make wx-tight). Flanged edge connecting louver to superstructure wasted.
Construction/Loadline
Issued 14 August 2001
Resolved
C/R epoxied spool piece on ovbd in stbd midvoid workshop.
Construction/Loadline
Issued 14 August 2001
Resolved
C/R wasted rub bar stiffeners as needed (>25% wastage).
Construction/Loadline
Issued 14 August 2001
Resolved
Seal port sewage ovbd as discussed w/ at least 1/4" circular steel plate w/continuous welds both sides. Permanently seal sewage tank ovbd piping. Vsl only operates on inland route. At O/O request, sewage ovbd removed to avoidillegal inadvertent discharge.
Construction/Loadline
Issued 14 August 2001
Resolved
V/W port fwd #1 transverse under deck/rub bar stiffener. Crack near vsl centerline.
Construction/Loadline
Issued 14 August 2001
Resolved
Make permanent repairs to air cond condensate drain ovbd. (Silicone sealantinside)
Lifesaving
Issued 14 August 2001
Resolved
Clean oil in engineroom (IE. electrical panels, equipment, blowers, etc.)
Construction/Loadline
Issued 14 August 2001
Resolved
Mechanically clean wasted/eroded welds & cap weld in forepeak.
Accommodation/Occupational Safety
Issued 14 August 2001
Resolved
Unclog all gooseneck vents to all underdeck spaces.
Construction/Loadline
Issued 14 August 2001
Resolved
Seal aft hull penetrations in aft steering void (stuffing tubes).
Accommodation/Occupational Safety
Issued 14 August 2001
Resolved
Repair broken deck drain in fuel tank void from men's head drain.
Construction/Loadline
Issued 14 August 2001
Resolved
Renew bilge piping in forepeak from first elbow.
Engineering
Issued 31 October 2000
Resolved
CLEAN STBD FUEL VENT FLAME SCREEN.
Lifesaving
Issued 31 October 2000
Resolved
INSTALL FLAME SCREEN IN SEWAGE VENT.
Documentation
Issued 31 October 2000
Resolved
INITIATE/POST STATION BILL.
Engineering
Issued 31 October 2000
Resolved
REPAIR HYDRAULIC LEAK ON PORT MAIN DIESEL ENGINE. _x001C_ _x001C_ _x001C_
Lifesaving
Issued 4 October 1999
Resolved
REPLACE RETROFLECTIVE MATERIAL ON PFD'S AS NEEDED.
Electrical
Issued 4 October 1999
Resolved
INSTALL DEADMAN COVER ON PILOTHOUSE DISTRIBUTION PANELS.
Electrical
Issued 4 October 1999
Resolved
REPAIR DISTRIBUTION PANEL IN MID BODY VOID.
Electrical
Issued 4 October 1999
Resolved
DEGREASE GALLEY HOOD VENT AND ENGINE ROOM BLOWER SYSTEM.
Engineering
Issued 4 October 1999
Resolved
INSTALL FLAME BOWLS ON PORT/STBD MAIN DIESEL ENGINE FUEL STRAINERS.
Fire Fighting
Issued 2 November 1998
Resolved
PROVIDE FIREFIGHTING EQUIPMENT SERVICING REPORT.
Fire Fighting
Issued 2 November 1998
Resolved
REPAIR FIRE SCREEN DOOR (GALLEY) SO THAT OPENING BETWEEN DOOR AND FRAME IS NOT GREATER THAN 1/2".
Lifesaving
Issued 17 November 1997
Resolved
REPLACE WATERLIGHT BATTERIES.
Fire Fighting
Issued 17 November 1997
Resolved
REPAIR CLOSURE DEVICES FOR ENGRM AND GALLEY DOORS.
Lifesaving
Issued 17 November 1997
Resolved
INSTALL RETRO-REFLECTIVE MATERIAL ON ALL LIFERINGS.
Electrical
Issued 17 November 1997
Resolved
INSTALL BATTERY SWITCHES IN BATTERY MAIN SUPPLY CONDUCTORS.
Fire Fighting
Issued 17 November 1997
Resolved
REMOVE HOLD BACK DEVICE FROM GALLEY DOOR.
Construction/Loadline
Issued 17 November 1997
Resolved
PROPERLY MARK WTD IN E/R AFT BLKHD.
Electrical
Issued 17 November 1997
Resolved
PROTECT BATTERY CONDUCTORS FROM MECHANICAL DAMAGE.
Electrical
Issued 17 November 1997
Resolved
PROCURE DI-ELECTRIC MAT FOR SWITCHBOARD.
Lifesaving
Issued 15 October 1996
Resolved
RENEW REFLECTIVE TAPE ON ALL (10) LIFE FLOATS.
Lifesaving
Issued 16 October 1995
Resolved
Secure all pfd boxes to the vessel.
Documentation
Issued 16 October 1995
Resolved
Provide and post employee assistance program information as required by 46CFR 16.401.
Accommodation/Occupational Safety
Issued 16 October 1995
Resolved
Secure bench seats on top deck or back to back.
Documentation
Issued 16 October 1995
Resolved
Provide drug testing records for all persons on the vessel involved with passenger safety.
Accommodation/Occupational Safety
Issued 12 July 1995
Resolved
Remove all clothing and linens from forward A/C rooms port and starboard.
Construction/Loadline
Issued 12 July 1995
Resolved
Repair reach rod to valve forward of collision bulkhead bilge suction.
Fire Fighting
Issued 12 July 1995
Resolved
When work complete replace missing insulation in engineroom.
Navigation
Issued 12 July 1995
Resolved
Demonstrate operation steering system; intalled new hydrolic piping.
Lifesaving
Issued 17 October 1994
Resolved
Provide on board 4 additional adult pfd's total passengers reduced to 366 until complete.
Electrical
Issued 17 October 1994
Resolved
Replace damaged or missing electrical cover plates - second deck bar.
Navigation
Issued 17 October 1994
Resolved
Straighten forward ruddder cross bar and align all 4 rudders to center.
Lifesaving
Issued 1 November 1993
Resolved
Provide two additional child pfd's.
Lifesaving
Issued 1 November 1993
Resolved
Stencil two life ring buoys with vessels name.
Electrical
Issued 1 November 1993
Resolved
Provide wire hangers for all electrical wiring under main deck stage and onstanchon to overhead & secure outlet boxes to stage.
Lifesaving
Issued 1 November 1993
Resolved
Repair bilge & watertight door alarm panel located in Pilot House.
Engineering
Issued 1 November 1993
Resolved
Properly mark emergency fuel shutdown valve.
Deck/Cargo
Issued 2 November 1992
Resolved
Secure guard on port side spud winch motor.
Accommodation/Occupational Safety
Issued 2 November 1992
Resolved
Replace relief valve on air compressor receiver port side.
Navigation
Issued 2 November 1992
Resolved
Double nut steering ram starboard and port side.
Engineering
Issued 4 November 1991
Resolved
REPAIR PORT MAIN ENG OIL PRESS GAGE-W.H.
Documentation
Issued 4 November 1991
Resolved
RENEW FCC STATION LICENSE.
Lifesaving
Issued 4 November 1991
Resolved
REMOUNT 1 OF 4 L/F LIGHT HOLDERS.
Lifesaving
Issued 4 November 1991
Resolved
PROVIDE 2 ADULT & 2 CHILD PFD'S
Documentation
Issued 4 November 1991
Resolved
RENEW FCC RADIOTELEPHONY CERT.
Accommodation/Occupational Safety
Issued 1 August 1991
Resolved
PROVIDE SIDE COVER FOR SECOND DECK ICE MACHINE.
Electrical
Issued 1 August 1991
Resolved
PROVIDE COVER FOR REFRIGERATION SPACE FLORESCENT LIGHT AND ALL OTHER SPACESWHERE MISSING
Electrical
Issued 1 August 1991
Resolved
PROVIDE COVER FOR BOTH AFT (OUTSIDE) SPEAKER JUNCTION BOXES.
Lifesaving
Issued 1 August 1991
Resolved
PROVIDE WATER LIGHTS FOR ALL BUOYANT APPARATUS. VESSEL IS LIMITED TO 1 MILE FROM LAND UNTIL THIS ITEM IS CORRECTED AND HAS BEEN CHECKED BY A MARINE INSPECTOR.
Lifesaving
Issued 5 November 1990
Resolved
CORRECT STENCILLING ONE PFD BOX.
Accommodation/Occupational Safety
Issued 5 November 1990
Resolved
CLOSE OPENING 2ND DECK ICE MACHINE.
Lifesaving
Issued 5 November 1990
Resolved
REPLACE 3 RING BUOYS PRIOR TO CARRYING PASSENGERS.
Engineering
Issued 5 November 1990
Resolved
REPAIR PORT ENGINE OIL PRESSURE GAGE - WH.
Electrical
Issued 5 November 1990
Resolved
REPAIR POWER AVAILABLE LIGHTS - SWITCHBOARD.
Documentation
Issued 5 November 1990
Resolved
POST GARBAGE STICKER EACH DECK AND PROVIDE GARBAGE MANAGEMENT PLAN.
Lifesaving
Issued 5 November 1990
Resolved
PAINT ALL LIFEFLOATS ORANGE.
Lifesaving
Issued 5 November 1990
Resolved
PLACE SPACERS BETWEEN ALL LIFEFLOATS.
Lifesaving
Issued 5 November 1990
Resolved
OVERHAUL ALL LIFEFLOAT NETTING.
Electrical
Issued 5 November 1990
Resolved
PROVIDE OUTLETS MAIN DECK BAND AREA FOR ALL CONSUMERS.
Fire Fighting
Issued 5 November 1990
Resolved
PROVIDE MARINE TYPE FIRE EXTINGUISHER BRACKETS.
Electrical
Issued 5 November 1990
Resolved
REPAIR MOTOR WIRING STBD FLAG POLE.
Electrical
Issued 5 November 1990
Resolved
PROVIDE GUARD AND GLOBES 2ND DECK AFT (4).
Engineering
Issued 5 November 1990
Resolved
REPAIR PORT ENGINE OIL LEAK (FUEL PUMP).
Fire Fighting
Issued 5 November 1990
Resolved
MARK FIRE STATION MAIN DECK BEHIND CURTAIN.
Documentation
Issued 4 January 1990
Resolved
CREDIT DRYDOCK DUE 04JUN91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULED THIS INSPECTION.
Lifesaving
Issued 13 November 1989
Resolved
REPLACE 60' PAINTER ATTACHING WATERLIGHT TO RING BUOY (AT STBD DECKHOUSE).
Lifesaving
Issued 13 November 1989
Resolved
REPAIR EMERGENCY LIGHT IN ENGINEROOM.
Lifesaving
Issued 13 November 1989
Resolved
PROVIDE 18' PAINTERS TO ATTACH WATERLIGHTS TO ALL LIFEFLOATS.
Lifesaving
Issued 13 November 1989
Resolved
PROVIDE 4' PADDLES FOR ALL LIFEFLOATS.
Engineering
Issued 14 November 1988
Resolved
PROVIDE PERMANENT MOUNT FOR HYDRAULIC OIL FILTERS BY NEXT DRYDOCK EXAM. AS A TEMPORARY REPAIR, STEEL CABLE SHALL BE PROVIDED.
Lifesaving
Issued 23 November 1987
Resolved
PROVIDE PADDLES FOR ALL LIFEFLOATS. ALL PADDLE ARE TO BE STENCILED WITH VESSELS NAME AND SECURED TO LIFEFLOATS .
Accommodation/Occupational Safety
Issued 23 November 1987
Resolved
REPAIR AND PROVE OPERATION OF EMERGENCY VENT SHUT DOWNS IN PILOTHOUSE.
Fire Fighting
Issued 23 November 1987
Resolved
PROVIDE FIVE (5) FIREHOSE MEETING THE REQUIREMENTS OF 46 CFR 181.15-5 (D)1.
Electrical
Issued 23 November 1987
Resolved
DEMONSTRATE THE OPERATION OF BOTH GENERATOR OVERSPEED TRIPS.
Fire Fighting
Issued 23 November 1987
Resolved
PROVIDE HAND FIRE PUMP IN ACCORDANCE WITH 46 CFR 181.10-5.
Lifesaving
Issued 23 November 1987
Resolved
PROVIDE LABEL FOR LIFEJACKET STORAGE LOCKER MAINDECK FWD ON STBD SIDE INDICATING HOW MANY LIFEJACKETS ARE STORED.
Fire Fighting
Issued 23 November 1987
Resolved
PROVIDE ONE (1) FIRE AXE.
Navigation
Issued 23 November 1987
Resolved
REPAIR BOW LIGHT PRIOR TO OPERATING AT NIGHT.
Lifesaving
Issued 13 February 1987
Resolved
PROVIDE COAST GUARD APPROVED WATERLIGHTS FOR LIFEFLOATS (10 TOTAL). VESSELIS RESTRICTED TO ONE (1) MILE FROM SHORE UNTIL LIGHTS INSTALLED. THE ABOVEITEM TO BE COMPLETED PRIOR TO 13MAR87 TO THE SATISFACTORY OF THE OFFICER INCHARGE OF MARINE INSPECTION.
Engineering
Issued 26 November 1986
Resolved
INSTALL A SUITABLE MEANS OF DETERMINING THE LIQUID LEVEL OF FUEL TANK.
Lifesaving
Issued 26 November 1986
Resolved
PROVIDE ELEVEN (11) ADDITIONAL ADULT LIFE PRESERVERS FOR A TOTAL OF 370.
Lifesaving
Issued 26 November 1986
Resolved
PROVIDE TWO (2) ADDITIONAL CHILD LIFE PRESERVERS FOR A TOTAL OF 37.
Documentation
Issued 26 November 1986
Resolved
PROVIDE ONBOARD THE VESSEL A VALID CERTIFICATE OF DOCUMENTATION FOR THIS VESSEL.
Casualty record · 11
22 August 2005Routine · role: Involved in a Marine Casualty · at BAYWAY STRUCTURE C · activity 2470848
17 November 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 3105049
9 May 2008Routine · role: Acknowledged Pollution Source · activity 3203328
10 December 2010Routine · role: Involved in a Marine Casualty · activity 3908731
19 January 2011Routine · role: Involved in a Marine Casualty · activity 3929877
1 August 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6513803
3 August 2019Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 6774885
6 December 2023Routine · role: Involved in a Marine Casualty · activity 7835837
1 February 2024Routine · role: Involved in a Marine Casualty · activity 7861386
16 June 2024Routine · role: Involved in a Marine Casualty · activity 7953328
4 October 2025Routine · role: Involved in a Marine Casualty · activity 8270887
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
STARLITE PRINCESS (2005–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.