Records from 2005 to 2026. Most recent: inspection, 13 January 2026.
Inspection history · 32
13 January 2026
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8295952
4 January 2026
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8297132
16 October 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8253756
4 October 2025
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8270887
5 March 2025
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8090218
10 January 2025
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8070490
17 June 2024
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7936362
16 June 2024
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7953328
1 February 2024
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7861386
14 December 2023
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7839092
6 December 2023
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7835837
6 December 2023
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7835990
14 November 2023
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7825155
16 August 2023
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7786273
6 June 2023
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7705014
5 December 2022
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7597864
17 August 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7536665
12 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7431251
30 November 2021
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7359583
8 December 2020
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7108383
20 October 2020
Administrative Inspection · Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7072297
3 October 2019
MTSA Verification · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6826752
3 August 2019
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6774885
23 October 2018
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6566371
9 October 2018
Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6558495
1 August 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6513803
8 December 2017
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6320949
3 November 2017
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6298975
22 August 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6247505
6 March 2017
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6099457
14 November 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6041539
12 February 2016
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5820749
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 January 2026
Resolved
Each life jacket must be marked with Type I retro-reflective material approved in accordance with § 164.018 in sub-chapter Q of this chapter, or other standard specified by the Commandant. 21 child life jackets need to have reflective tape replaced. Total children allowed reduced to 15.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 January 2026
Resolution: MI received photo evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 January 2026
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Letters and numbers must be at least 50 millimeters (2 inches) high.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 January 2026
Resolution: MI received photo evidence.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 January 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to:Protect passengers, crew, other persons, and the vessel from electrical hazards caused by or originating in electrical equipment, and electrical shock. Install proper electrical mating in front of electric switchboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2026
Resolved 2 February 2026
Resolution: MI received photo evidence.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel is incapable of operating in astern propulsion due to an undiagnosed mechanical issue. Rapier to the satisfaction of a USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2024
Resolved 18 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 December 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements. Five boards on the stbd paddle wheel outboard side have dings and chips from allision. Replace in kind.
46 CFR 119.200
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2023
Resolved 18 December 2023
Resolution: Boards replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 November 2023
Resolved
A vessel must carry one floating waterlight unless it is restricted to daylight only operation. The battery in the waterlight was expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2023
Resolved 14 December 2023
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 November 2023
Resolved
A self propelled vessel 65 feet or greater in commercial service must have a class A AIS. The 5 year deviation from AIS requirement has expired and installation of an AIS is required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2023
Resolved 14 December 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 June 2023
Resolved
Emergency exits shall be clearly marked "EMERGENCY EXIT, KEEP CLEAR" on both sides of the escape door. Emergency escape was not posted on the outside of the door from the engine room.
Action required: 10 - Deficiency Rectified
Due 8 June 2023
Resolved 8 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2022
Resolved
All electrical equipment and circuits must be clearly marked and identified. Electrical panel in the galley on the stbd side is mislabeled/not clearly marked. Clearly mark panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 13 January 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. Light cover in the galley on the stbd side is broken. Replace broken light cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 13 January 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2022
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew spaces located below the main deck. Emergency light inoperable in "girl's side" storage area. Prove proper operation of emergency light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 13 January 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2022
Resolved
All cable and wire must: Be installed with metal supports spaced not more than 24 inches apart. Hanging wires in "girl's side" storage area not properly supported. Properly support hanging wires.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 13 January 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 December 2022
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel name not fully legible on ring life buoys. Re-stencil vessel name on ring life buoys.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 5 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 December 2022
Resolved
Each life jacket must be marked with Type I retroreflective material approved in accordance with § 164.018. Retroreflective material on multiple child lifejackets not serviceable. Renew deteriorated retro material.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 5 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 December 2022
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with § 164.018. Retroreflective material on ring life buoys throughout not serviceable. Renew deteriorated retro material.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 5 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 December 2022
Resolved
At least one ring life buoy must be fitted with a lifeline. Fitted lifeline on ring life buoy forward of the house is deteriorated. Renew lifeline.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2022
Resolved 5 December 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 December 2022
Resolved
A door in a fire control boundary must meet the following requirements: A door must be capable of operation from either side by one person. Galley door will not close. Prove proper operation of door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 13 January 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 December 2022
Resolved
A-Class bulkheads or decks must be so insulated with approved structural insulation, bulkhead panels, or deck covering. Various structural fire protection missing/damaged/poor material condition in the engine room. Renew damaged structural fire protection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 13 January 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 December 2022
Resolved
The following spaces must be equipped with a fire detection and alarm system of an approved type that is installed in accordance with part 76 in subchapter H of this chapter: A space containing an internal combustion engine of more than 37.3 kW (50 hp). Heat detector in engine room is inoperable/crew unable to test. Prove proper operation of detector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 13 January 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 December 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Replace missing bolts on aft railing below flagpole. Renew stanchion on flying bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 13 January 2023
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 5 December 2022
Resolved
Watertight doors and watertight hatches must be marked on both sides in clearly legible letters. Escape hatch from galley challenging to open/confusing to operate. Prove proper functioning of hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 13 January 2023
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 5 December 2022
Resolved
Vessel control systems and other miscellaneous systems and equipment required by this part must be suitable for the purposes intended. Prove operation of watertight door indicator on bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 13 January 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 December 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Port side water tank access leaking into storage/workshop area. Repair leak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 13 January 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2022
Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of 46 CFR 4.06. Alcohol test strips expired. Renew alcohol test strips.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 13 January 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 November 2021
Resolved
The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Repair lagging on the exhaust on starboard generator.
Action required: 10 - Deficiency Rectified
Due 30 November 2021
Resolved 30 November 2021
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 November 2021
Resolved
The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Repair damper to galley to ensure it is capable of fully closing.
Action required: 10 - Deficiency Rectified
Due 30 November 2021
Resolved 30 November 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 October 2020
Resolved
A voltmeter and an ammeter, which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. The ammeter for both generators was not operable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2020
Resolved 8 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 October 2020
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Oil leaks identified on both generators.
Action required: 705 - Other - as specified
Due 27 October 2020
Resolved 4 November 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 October 2019
Resolved
Replace wasted grabline on ring buoys on port and starboard bridge wings.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2019
Resolved 3 October 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 October 2019
Resolved
Service door (hatch) between galley and storeroom is not operable from both sides. Make door operable from the galley side.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 8 October 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 October 2019
Resolved
Replace broken window on starboard side in upper dining room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 30 October 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 October 2019
Resolved
Repair wasted gooseneck vent on main deck starboard side under stairs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 30 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2019
Resolved
Remove or permanently protect exposed wires IWO upper deck A/C units and upper sevice station overhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 8 October 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 October 2019
Resolved
Provide alcohol test kits.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 8 October 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 October 2019
Resolved
Post stability letter and establish a waste management plan.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 8 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 October 2018
Resolved
Pack bilge pump seal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2018
Resolved 23 October 2018
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 9 October 2018
Resolved
Provide guard for rotating machinery on bilge pump.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2018
Resolved 23 October 2018
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 3 November 2017
Resolved
Provide 10 adult size type I PFD's. Persons allowed onbaord reduced to 350 until provided.
Condition: Improper/Lack of Maintenance
Due 7 December 2017
Resolved 8 December 2017
Resolution: corrected
Documentation › Certificates/Documents › FCC SSL
Issued 3 November 2017
Resolved
Provide FCC Safety Certificate.
Condition: Improper/Lack of Maintenance
Due 7 December 2017
Resolved 8 December 2017
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 November 2017
Resolved
Renew broken windows.
Condition: Damaged By Earlier Event
Due 7 December 2017
Resolved 8 December 2017
Resolution: Corrected
Engineering › Lubricating Oil Service System › Gauge
Issued 14 November 2016
Resolved
Prove proper operation of port MDE oil pressure gauge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 6 March 2017
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 14 November 2016
Resolved
Provide 1st aid/CPR training for 50% of crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 6 March 2017
Construction/Loadline › Penetrations › Pipe Flange
Issued 14 November 2016
Resolved
Remove and properly repair the stbd side aft stern side shell in the rudder room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 3 November 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 14 November 2016
Resolved
Provide cover for light in galley port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 6 March 2017
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 November 2016
Resolved
Label breakers in galley breaker box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 6 March 2017
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 November 2016
Resolved
Repair / renew electric panelboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 3 November 2017
Electrical › Electrical Distribution System (service) › Switch
Issued 14 November 2016
Resolved
Install switch for ammeter.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 6 March 2017
Electrical › Electrical Distribution System (service) › Switch
Issued 14 November 2016
Resolved
Properly label switches on bridge panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 6 March 2017