08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 December 2022
No resolution recorded
A visual and audible bilge high level alarm must be provided at the operating station. High level alarm did not function. 46CFR182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 December 2022
No resolution recorded
The owner or managing operator of a vessel shall ensure
that the vessel complies with the laws and regulations
applicable to the vessel and that the vessel is
otherwise satisfactory for the intended service. The
initial inspection may include an inspection of the
following items: (1) The arrangement, installation,
materials, and scantlings of the structure including the
hull and superstructure, yards, masts, spars,rigging,
sails.
The following areas were identified that required repair or further inspection.
-Jib sheet is missing cleate on STBD side.
-Submited pictures of foremast spreaders attachment for further inspection.
-Port fwd chain plate attachment hardware is resting on frame edge. Reposition hardware.
-port running back stay hardware is undersized.
-twisting shackles on main/fore gaff lifting halyard undersized.
-main sheet aft attachment hardware undersized.
-flying jib boom attachment points shows signed of wear. jib requires removal for further inspection.
-submit pictures of main mast cheeck replacement for further inspection.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 December 2022
No resolution recorded
Portable watertight containers for distress flares shall be clearly marked with legible letters DISTRESS FLARES. Flare container was not marked in accordance with 46CFR185.614.
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 December 2022
No resolution recorded
The name of a vessel must be marked or painted in clearly legible letters and numbers on each life buoy. Buoy was not marked with vessel name. 46CFR185.604
Action required: 50 - Rectify deficiencies w/in 30 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2022
No resolution recorded
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation for the purpose intended. Handle on valve on fuel return line near tank was missing. 46CFR182.100
Action required: 50 - Rectify deficiencies w/in 30 days
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 November 2022
No resolution recorded
The owner or managing operator of a vessel shall ensure
that the vessel complies with the laws and regulations
applicable to the vessel and that the vessel is
otherwise satisfactory for the intended service. The
initial inspection may include an inspection of the
following items: (1) The arrangement, installation,
materials, and scantlings of the structure including the
hull and superstructure, yards, masts, spars,rigging,
sails.
The following portions of the rigging require repair/
replacement. Submit repair plan to include receipts and
materials used.
-Foremast throat halliard gaff lifting attachment
hardware is bent.
-Staysail lower turnbuckle attachment hardware not
seized
-Foremast port fwd lower shroud has a bent arm
-Foremast port lower shroud loose
-Outter bobstay turnbuckle bottomed out and rigging is
loose.
-P/S whiskey stays are loose
-Main sail gaff topping lifts have elongated attachment
hardware. (peak halliard)
-Boom collar for main sheet is appx 12in fwd of original
position. Traveler running rigging is chaffing on wheel
house.
-Pin rail for main mast not properly secured. Two
attachment screws are missing on top of house.
-Main sail gaff throat has damage to spar. Section
coming off (possibly a previous repair) near lifting
hardware.
-Port running back stay attachment hardware at block is
undersized and bent.
-Multiple sections of rigging found not fully tightened
or hardware is not fully installed, inspect rigging to
identify all hardware not installed properly.
46CFR176.402(c)
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 November 2022
No resolution recorded
Inspect all railings and bulwarks and their attachment
to the hull structure. Handrail is not attached to deck,
in way of STBD main mast shroud. 46CFR176-25-5
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2022
No resolution recorded
This part is intended to provide a minimum standard of
regulations for electrical installations and equipment
that will result in a vessel that is reasonably safe
from fire caused by and/or originating in electrical
equipment and reasonably safety of electrical shock of
persons. Multiple dead end wires through out vessel
cabin, machinery space, and on deck. 46CFR183.01-5
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 November 2022
No resolution recorded
Except as otherwise provided in this section, machinery
and fuel tank spaces shall be separated from
accommodation spaces by watertight and/or vapor tight
bulkheads of double diagonal wood, marine plywood, steel
plate,or equivalent construction. Multiple sections of
machinery space are not vapor tight. 46CFR183-25.1
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 November 2022
No resolution recorded
A portable hand bilge pump must be: (2) Provided with
suitable suction hose capable of reaching the bilge of
each watertight compartment and discharging overboard
Hand bilge pump missing discharge hose. 46CFR182.520(b)
Action required: 701 - Prior to carriage of passengers/cargo
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 November 2022
No resolution recorded
Individual power pumps used for separate spaces are to
be controlled from a central control point and must
have a light or other visual means at the control point
to indicate operation. One of the submersible bilge
pumps is indicating it is in operation when it is off. 46CFR182.520(a)
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 November 2022
No resolution recorded
Foremast nav light wiring is not watertight at deck.
Action required: 705 - Other - as specified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 10 November 2022
No resolution recorded
Deck planking above main cabin port side has significant
flex when weight is applied. (above Carlin repair)
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 November 2022
No resolution recorded
Cracked Plank STBD side under main sail shroud. Submit repair plan.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 September 2021
Resolved
Starboard
Provide repair plan for the following loose or damaged planks.
Plank above sheer strike in vicinity of frames 5-7 (under bowsprit chain plate)
Plank D in vicinity of frames 21-22
Plank D in vicinity of frames 28-29
Plank above sheer strike in vicinity of frames 27-29.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2022
Resolution: Vessel adequately repaired all areas identified
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 September 2021
Resolved
Vessel has multiple portions of the hull with water ingress. Forward bilge area in between frames 12 and 13 had signficant water ingress and needs to be evaluated at drydock. Shaft packing also had significant drippage into the bilge. Operator had two submersible pumps actively running that were not keeping up with the rate of flooding. Fastener on bow sticking out 4-5".
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2022
Resolution: Multiple planks have been replaced and keel damage repaired. Conducted underway exam after repairs with no water ingress noted.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 September 2021
No resolution recorded
Rigging was not ready for inspection, multiple blocks and fitting were worn, masts were leaning and not true, rigging was not tuned. Lead inspector issued requirement for third party rigging surveyor referencing NVIC 02-16.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 September 2021
No resolution recorded
The operator was unable to provide an adequate preventative maintenance plan IAW NVIC 02-16.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 September 2021
No resolution recorded
Port and starboard wire railing had excessive slack along with multiple support stanchions that could not bare required weight.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2021
Resolved
Multiple runs of non marine grade wiring throughout boat. Wiring to forward mast light and multiple sections of unathorized repairs. Multiple sections of extension cords daisy chained together.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 November 2022
Resolution: Seperated defs into multiple for ease of sign offs and deferments.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2021
Resolved
A vessel of more than 7.9 meters(26 feet) in length, but not more than19.8 meters (65 feet), must carry a min-imum of one life buoy of not less than610 millimeters (24 inches) in diameter;and. Each ring life buoy on a vessel must:(1) Be approved in accordance with §160.050 in subchapter Q of this chapter.Life ring buoy was deteriorated had no water light or throw line attached. 46CFR180.70
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 December 2022
Resolution: Vessel installed proper ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 10 September 2021
Resolved
Hydrostatic release unit was improperly marked. The expiration date was marked to 2024 exceeding the 2 year requirement.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 November 2022
Resolution: Vessel installed and properly marked hydrostatic release.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 September 2021
Resolved
Vessel operator could not provide the Safety Radiotelephony Certificate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 December 2022
Resolution: Vessel had a valid radiotelephony certificate.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 9 June 2021
Resolved
Provide Cat I 406 Mhz EPIRB with registration and properly mount and mark hydrostatic release with expiry date.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2021
Resolved 22 June 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 May 2021
Resolved
Shroud spreader for topmast of main mast (aft mast) was damaged and non-functional. Provide repair proposal and make permanent repairs to spreader.
Action required: 705 - Other - as specified
Due 31 July 2021
Resolved 3 February 2022
Resolution: Spreader was repaired and appeared satisfactory for single voyage without passengers.
Vessel now in SecNY zone and undergoing repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 July 2019
Resolved
Vessel is required to carry 12 flares. Vessel only carried 8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 2 August 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2019
Resolved
Provide proof of enrollment in and pre-employment test for all new crewmembers.
Due 2 August 2019
Resolved 1 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 July 2019
Resolved
Each lifebouy must be marked with type II retroreflective material as specified in IMO Res A.658(k)
Due 30 August 2019
Resolved 2 August 2019
Construction/Loadline › Hull › Side Shell
Issued 2 October 2017
Resolved
Deterioration/wood rot noted in way of stbd side frame #10, 4th plank down from gunwhale. Renew affected plank section or effect repair using an approved wood restoration technique.
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 3 May 2018
Resolution: Renewed affected area
Construction/Loadline › Hull › Transverse Frame
Issued 2 October 2017
Resolved
Deterioration/wood rot noted in way of stbd side partial bulwark frames #15 & 16. Renew partial frames 15 & 16 stbd side from bulwark through deck to existing joints.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 3 May 2018
Resolution: Renewed affected section(s)
Construction/Loadline › Hull › Stringer
Issued 2 October 2017
Resolved
Bulwarks planking damaged/fractured in way of freeing port stbd side Fr 15/16. Renew/repair affected damaged bulwarks.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 3 May 2018
Resolution: Renewed affected area(s).
Stability › Watertight Integrity › General
Issued 2 October 2017
Resolved
Areas of deck planking Port side from frame #10-19 indicate rot and non-watertight seal. Seal port side deck sheer plank area frame 10-19 and make watertight and/or renew deck planking in way of affected area.
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 3 May 2018
Resolution: Planks and associated underdeck beams renewed affected areas.
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 September 2017
Resolved
Bilge high level alarm not functioning. Prove proper operation of audible and visual alarm.
Due 2 October 2017
Resolved 2 October 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 September 2017
Resolved
Port running light fixture not functioning. Prove proper operation of all navigation lights.
Vessel is restricted to daylight operation until all lights prove to be illuminating properly
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 7 September 2018
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 September 2016
Resolved
Remote emergency fuel cutoff valve does not fully close. Adjust as necessary and prove proper operation/closure. 46 CFR 182.455(b)(4)
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 18 September 2017
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 September 2016
Resolved
Original COD not onboard. Provide original certificate of documentation.
Due 30 September 2016
Resolved 3 May 2018
Resolution: Verified Certificate of Documentation renewed and valid
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 15 September 2016
Resolved
EAP hotline and contact information not posted. Post hotline and pertinent EAP information. 46CFR 16.401
Due 30 September 2016
Resolved 18 September 2017
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 15 September 2016
Resolved
Record of supervisor training not available. Provide proof of supervisor training.
Due 30 September 2016
Resolved 19 September 2016
Resolution: Received Email afficavit of training from consortium administrator.
Construction/Loadline › Hull › Side Shell
Issued 15 September 2016
Resolved
Rubrails were damaged and associated planking may have damage beneath rubrails. Make repairs to damageed rubrails and associated planking.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 18 September 2017