MAURY USCG vessel records Sign in
← All vessels

RED SEA

RED SEA is a 1986 passenger vessel (inspected). The Coast Guard has recorded 86 inspections since 1986, most recently in November 2023, along with 159 deficiencies — 17 with no resolution recorded —, 1 operational control and 4 casualty investigations between 2006 and 2022.

Records from 1986 to 2023. Most recent: inspection, 7 November 2023.

Built
1986
Last inspected
7 November 2023
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM4299
275926
Flag
UNITED STATES
368205130
Maury page id
psix-275926

Inspections, by type

…with no type recorded10
Years with a record 35 calendar years (1986–2023)
The 86 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)54.8 ft × 16.6 ft × 9.0 ft
Registered tonnagegross 41 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNATHANIEL ZIRLOTT · MOBILE, AL, UNITED STATES · built 1986
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Simplified, Gross Ton
41 - Simplified, Net Ton
0 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM4299MMSI 368205130 · active · compulsorily equipped · granted 16 June 2021, expires 16 June 2031
WDF7905MMSI 367489360 · expired · compulsorily equipped · granted 7 May 2011, cancelled 17 July 2021
WDC5284MMSI 367038750 · terminated · compulsorily equipped · granted 3 May 2005, cancelled 16 June 2015
WCW6859MMSI not assigned · expired · voluntarily equipped · granted 20 June 1996, cancelled 26 August 2006
WCK3226MMSI not assigned · expired · compulsorily equipped · granted 28 July 1994, cancelled 2 October 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 86

7 November 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7821266
15 December 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7610003
15 December 2022 Administrative Inspection · Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7610057
10 September 2021 Hull Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7296916
21 May 2021 COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7206827
17 June 2020 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6979122
30 July 2019 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6826847
7 September 2018 Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6559226
2 October 2017 Drydock Exam · Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6279909
18 September 2017 Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6266002
15 September 2016 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5984172
29 August 2016 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5986140
27 July 2016 Attraction Vessel Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5961190
29 August 2014 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4972026
1 May 2012 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4299324
9 September 2011 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4183850
8 September 2011 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4143396
11 August 2011 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4113173
8 May 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3472033
8 April 2009 Inclining Experiment
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3449925
13 January 2009 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3393147
17 September 2008 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3325590
27 August 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3310412
8 August 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3296136
5 August 2008 Simplified Stability Test
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3289883
31 July 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3285191
31 July 2008 Examination of Repairs
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 3285291
24 July 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3277873
23 July 2008 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3339584
19 July 2008 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3339540
13 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3205384
21 April 2008 Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3188805
17 October 2007 Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3080930
10 September 2007 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3048726
8 September 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2775358
7 August 2006 Attraction Vessel Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2738882
26 June 2006 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2691918
12 June 2006 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2677329
9 June 2006 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2689460
30 May 2006 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2664207
9 October 2005 Type not recorded
No type recorded · Station Kenosha · USCG Great Lakes District (CGD-GL) · Activity 2513966
16 May 2005 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2359173
9 May 2005 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2353152
9 July 2004 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2127079
24 July 2003 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1859551
24 June 2003 Periodic Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1825701
5 May 2003 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1786716
1 July 2002 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1728087
21 June 2001 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1408760
13 September 2000 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1053650
8 June 2000 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1443035
23 August 1999 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1114318
22 June 1999 Plan Review "T" Boat · Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1375834
19 June 1998 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1130238
18 May 1998 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1445349
30 April 1997 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1458388
8 August 1996 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1087461
7 June 1996 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1363658
3 May 1996 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1088079
18 April 1996 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1355748
23 October 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1182595
22 July 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1448674
18 April 1995 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1367370
27 May 1994 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1321626
25 March 1994 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1419240
10 December 1993 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1385170
16 March 1993 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1320869
28 January 1993 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1447212
11 May 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1473392
15 April 1992 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 943085
31 March 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 963034
22 January 1992 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 947554
30 September 1991 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 937214
30 September 1991 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1403509
24 January 1991 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1238569
18 December 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 901041
16 March 1990 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1234130
28 November 1989 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1235394
10 October 1989 Drydock Extension · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1335291
13 May 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 889041
11 May 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1043133
15 March 1988 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1031295
15 June 1987 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1030344
3 June 1987 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1335174
12 February 1987 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1321198
9 December 1986 Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1000288

Deficiency record · 159

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 December 2022 No resolution recorded
A visual and audible bilge high level alarm must be provided at the operating station. High level alarm did not function. 46CFR182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 December 2022 No resolution recorded
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. The initial inspection may include an inspection of the following items: (1) The arrangement, installation, materials, and scantlings of the structure including the hull and superstructure, yards, masts, spars,rigging, sails. The following areas were identified that required repair or further inspection. -Jib sheet is missing cleate on STBD side. -Submited pictures of foremast spreaders attachment for further inspection. -Port fwd chain plate attachment hardware is resting on frame edge. Reposition hardware. -port running back stay hardware is undersized. -twisting shackles on main/fore gaff lifting halyard undersized. -main sheet aft attachment hardware undersized. -flying jib boom attachment points shows signed of wear. jib requires removal for further inspection. -submit pictures of main mast cheeck replacement for further inspection.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 December 2022 No resolution recorded
Portable watertight containers for distress flares shall be clearly marked with legible letters DISTRESS FLARES. Flare container was not marked in accordance with 46CFR185.614.
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 December 2022 No resolution recorded
The name of a vessel must be marked or painted in clearly legible letters and numbers on each life buoy. Buoy was not marked with vessel name. 46CFR185.604
Action required: 50 - Rectify deficiencies w/in 30 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2022 No resolution recorded
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation for the purpose intended. Handle on valve on fuel return line near tank was missing. 46CFR182.100
Action required: 50 - Rectify deficiencies w/in 30 days
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 November 2022 No resolution recorded
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. The initial inspection may include an inspection of the following items: (1) The arrangement, installation, materials, and scantlings of the structure including the hull and superstructure, yards, masts, spars,rigging, sails. The following portions of the rigging require repair/ replacement. Submit repair plan to include receipts and materials used. -Foremast throat halliard gaff lifting attachment hardware is bent. -Staysail lower turnbuckle attachment hardware not seized -Foremast port fwd lower shroud has a bent arm -Foremast port lower shroud loose -Outter bobstay turnbuckle bottomed out and rigging is loose. -P/S whiskey stays are loose -Main sail gaff topping lifts have elongated attachment hardware. (peak halliard) -Boom collar for main sheet is appx 12in fwd of original position. Traveler running rigging is chaffing on wheel house. -Pin rail for main mast not properly secured. Two attachment screws are missing on top of house. -Main sail gaff throat has damage to spar. Section coming off (possibly a previous repair) near lifting hardware. -Port running back stay attachment hardware at block is undersized and bent. -Multiple sections of rigging found not fully tightened or hardware is not fully installed, inspect rigging to identify all hardware not installed properly. 46CFR176.402(c)
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 November 2022 No resolution recorded
Inspect all railings and bulwarks and their attachment to the hull structure. Handrail is not attached to deck, in way of STBD main mast shroud. 46CFR176-25-5
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2022 No resolution recorded
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment and reasonably safety of electrical shock of persons. Multiple dead end wires through out vessel cabin, machinery space, and on deck. 46CFR183.01-5
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 November 2022 No resolution recorded
Except as otherwise provided in this section, machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads of double diagonal wood, marine plywood, steel plate,or equivalent construction. Multiple sections of machinery space are not vapor tight. 46CFR183-25.1
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 November 2022 No resolution recorded
A portable hand bilge pump must be: (2) Provided with suitable suction hose capable of reaching the bilge of each watertight compartment and discharging overboard Hand bilge pump missing discharge hose. 46CFR182.520(b)
Action required: 701 - Prior to carriage of passengers/cargo
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 November 2022 No resolution recorded
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. One of the submersible bilge pumps is indicating it is in operation when it is off. 46CFR182.520(a)
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 November 2022 No resolution recorded
Foremast nav light wiring is not watertight at deck.
Action required: 705 - Other - as specified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 10 November 2022 No resolution recorded
Deck planking above main cabin port side has significant flex when weight is applied. (above Carlin repair)
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 November 2022 No resolution recorded
Cracked Plank STBD side under main sail shroud. Submit repair plan.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 September 2021 Resolved
Starboard Provide repair plan for the following loose or damaged planks. Plank above sheer strike in vicinity of frames 5-7 (under bowsprit chain plate) Plank D in vicinity of frames 21-22 Plank D in vicinity of frames 28-29 Plank above sheer strike in vicinity of frames 27-29.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2022
Resolution: Vessel adequately repaired all areas identified
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 September 2021 Resolved
Vessel has multiple portions of the hull with water ingress. Forward bilge area in between frames 12 and 13 had signficant water ingress and needs to be evaluated at drydock. Shaft packing also had significant drippage into the bilge. Operator had two submersible pumps actively running that were not keeping up with the rate of flooding. Fastener on bow sticking out 4-5".
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2022
Resolution: Multiple planks have been replaced and keel damage repaired. Conducted underway exam after repairs with no water ingress noted.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 September 2021 No resolution recorded
Rigging was not ready for inspection, multiple blocks and fitting were worn, masts were leaning and not true, rigging was not tuned. Lead inspector issued requirement for third party rigging surveyor referencing NVIC 02-16.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 September 2021 No resolution recorded
The operator was unable to provide an adequate preventative maintenance plan IAW NVIC 02-16.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 September 2021 No resolution recorded
Port and starboard wire railing had excessive slack along with multiple support stanchions that could not bare required weight.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2021 Resolved
Multiple runs of non marine grade wiring throughout boat. Wiring to forward mast light and multiple sections of unathorized repairs. Multiple sections of extension cords daisy chained together.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 November 2022
Resolution: Seperated defs into multiple for ease of sign offs and deferments.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2021 Resolved
A vessel of more than 7.9 meters(26 feet) in length, but not more than19.8 meters (65 feet), must carry a min-imum of one life buoy of not less than610 millimeters (24 inches) in diameter;and. Each ring life buoy on a vessel must:(1) Be approved in accordance with §160.050 in subchapter Q of this chapter.Life ring buoy was deteriorated had no water light or throw line attached. 46CFR180.70
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 December 2022
Resolution: Vessel installed proper ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 10 September 2021 Resolved
Hydrostatic release unit was improperly marked. The expiration date was marked to 2024 exceeding the 2 year requirement.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 November 2022
Resolution: Vessel installed and properly marked hydrostatic release.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 September 2021 Resolved
Vessel operator could not provide the Safety Radiotelephony Certificate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 December 2022
Resolution: Vessel had a valid radiotelephony certificate.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 9 June 2021 Resolved
Provide Cat I 406 Mhz EPIRB with registration and properly mount and mark hydrostatic release with expiry date.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2021
Resolved 22 June 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 May 2021 Resolved
Shroud spreader for topmast of main mast (aft mast) was damaged and non-functional. Provide repair proposal and make permanent repairs to spreader.
Action required: 705 - Other - as specified
Due 31 July 2021
Resolved 3 February 2022
Resolution: Spreader was repaired and appeared satisfactory for single voyage without passengers. Vessel now in SecNY zone and undergoing repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 July 2019 Resolved
Vessel is required to carry 12 flares. Vessel only carried 8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 2 August 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2019 Resolved
Provide proof of enrollment in and pre-employment test for all new crewmembers.
Due 2 August 2019
Resolved 1 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 July 2019 Resolved
Each lifebouy must be marked with type II retroreflective material as specified in IMO Res A.658(k)
Due 30 August 2019
Resolved 2 August 2019
Construction/Loadline › Hull › Side Shell
Issued 2 October 2017 Resolved
Deterioration/wood rot noted in way of stbd side frame #10, 4th plank down from gunwhale. Renew affected plank section or effect repair using an approved wood restoration technique.
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 3 May 2018
Resolution: Renewed affected area
Construction/Loadline › Hull › Transverse Frame
Issued 2 October 2017 Resolved
Deterioration/wood rot noted in way of stbd side partial bulwark frames #15 & 16. Renew partial frames 15 & 16 stbd side from bulwark through deck to existing joints.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 3 May 2018
Resolution: Renewed affected section(s)
Construction/Loadline › Hull › Stringer
Issued 2 October 2017 Resolved
Bulwarks planking damaged/fractured in way of freeing port stbd side Fr 15/16. Renew/repair affected damaged bulwarks.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 3 May 2018
Resolution: Renewed affected area(s).
Stability › Watertight Integrity › General
Issued 2 October 2017 Resolved
Areas of deck planking Port side from frame #10-19 indicate rot and non-watertight seal. Seal port side deck sheer plank area frame 10-19 and make watertight and/or renew deck planking in way of affected area.
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 3 May 2018
Resolution: Planks and associated underdeck beams renewed affected areas.
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 September 2017 Resolved
Bilge high level alarm not functioning. Prove proper operation of audible and visual alarm.
Due 2 October 2017
Resolved 2 October 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 September 2017 Resolved
Port running light fixture not functioning. Prove proper operation of all navigation lights. Vessel is restricted to daylight operation until all lights prove to be illuminating properly
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 7 September 2018
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 September 2016 Resolved
Remote emergency fuel cutoff valve does not fully close. Adjust as necessary and prove proper operation/closure. 46 CFR 182.455(b)(4)
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 18 September 2017
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 September 2016 Resolved
Original COD not onboard. Provide original certificate of documentation.
Due 30 September 2016
Resolved 3 May 2018
Resolution: Verified Certificate of Documentation renewed and valid
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 15 September 2016 Resolved
EAP hotline and contact information not posted. Post hotline and pertinent EAP information. 46CFR 16.401
Due 30 September 2016
Resolved 18 September 2017
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 15 September 2016 Resolved
Record of supervisor training not available. Provide proof of supervisor training.
Due 30 September 2016
Resolved 19 September 2016
Resolution: Received Email afficavit of training from consortium administrator.
Construction/Loadline › Hull › Side Shell
Issued 15 September 2016 Resolved
Rubrails were damaged and associated planking may have damage beneath rubrails. Make repairs to damageed rubrails and associated planking.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 18 September 2017
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 29 August 2014 Resolved
Ensure all fuses are suitable for the service intended and are installed as per approved one line electrical diagram
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2014
Resolved 29 August 2014
Resolution: O/O replaced 4 fuses to match approved one line diagram.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 August 2014 Resolved
Provide USCG approved First Aid kit
Action required: 705 - Other - as specified
Due 29 September 2014
Resolved 9 October 2014
Resolution: Purchased new USCG Approved First aid kit
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 August 2014 Resolved
Provide COD
Action required: 705 - Other - as specified
Due 29 September 2014
Resolved 23 September 2014
Resolution: New COD is on board vessel
Construction/Loadline › Hull › Sheerstrake
Issued 29 August 2014 Resolved
Repair wooden rub rail during winter lay up.
Action required: 705 - Other - as specified
Due 1 April 2015
Resolved 1 April 2015
Resolution: Rub Rail repaired.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 September 2011 Resolved
Prior to carrying passengers conduct emergency drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2011
Resolved 9 September 2011
Resolution: Company replaced ladder used during man overboard recovery. Attended vessel and witnessed man overboard recovery drill at the pier. Operation and condition of equipment used for evolution was sat. Crew aptitude and knowledge of performing task sat.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 September 2008 Resolved
Provide sufficient means of recovering man overboard IAW 46 CFR 185.520 and 46 CFR 176.800(a) prior to 2009 operating season. (April 15, 2009)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 8 May 2009
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 September 2008 Resolved
Provide lifeline for ring buoy on STBD side IAW 46 CFR 180-070(c).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 8 May 2009
Stability › Incline Test › General
Issued 31 July 2008 Resolved
Prior to carrying passengers conduct a satisfactory stability test in the presence of a CG Marine Inspector and place on board a stability letter.
Due 11 August 2008
Resolved 6 August 2008
Resolution: Simplified stability test conducted and stability letter isssued.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 31 July 2008 Resolved
Prior to carrying passengers demonstrate proper operation and installation of engine and reduction gear to the satisfaction of the attending CG Marine Inspector
Due 11 August 2008
Resolved 11 August 2008
Resolution: Engine and reduction gear tested sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 31 July 2008 Resolved
Prior to carrying passengers demonstrate proper operation and installation of engine and reduction gear to the satisfaction of the attending CG Marine Inspector
Due 11 August 2008
Resolved 11 August 2008
Resolution: Engine and reduction gear tested sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 24 July 2008 Resolved
Vessel reported mechanical problems with their transmission. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2008
Resolved 11 August 2008
Resolution: Reduction gear tested sat.
Construction/Loadline › Penetrations › Pipe Flange
Issued 17 October 2007 Resolved
Remove and make available for inspection the forward though hull fitting and valve in the vessel's head in accordance with 46 CFR 176.610, or remove the through hull fitting and it deteriorated piping.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2008
Resolution: Received an E-Mail from the vessel Master [name withheld] verifying the vessels deteriorated through hull fitting and piping had been replaced and capped off. [name withheld] included a picture of the corrected piping.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 10 September 2007 Resolved
Prior to operation with passengers on board provide (5) additional child sized type I PFDs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 12 June 2006 Resolved
Troubleshoot and effect proper repairs to the engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2006
Stability › Watertight Integrity › General
Issued 12 June 2006 Resolved
Effect repairs to damaged bulwarlks, rub rails, and hull structures.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2006
Stability › Unintentional Flooding › General
Issued 12 June 2006 Resolved
Make bilges clean and dry
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2006
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 12 June 2006 Resolved
Ensure crewmembers conduct and pass a pre-employment drug test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 12 June 2006 Resolved
Properly install flame guard on fuel filters.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 8 September 2006
Resolution: Flame guards installed as required.
Construction/Loadline › Hull › Hull Plating
Issued 12 June 2006 Resolved
Properly effect repairs to backing blocks for chain plates on the port side fwd.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 22 June 2006
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 12 June 2006 Resolved
Provide proof of training meeting the requirements of company's own drug and alcohol program.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 22 June 2006
Construction/Loadline › Structures › Superstructure
Issued 30 May 2006 Resolved
Replace broken port light glass in foward lazarrett 46 CFR 117.116(f)
Action required: 705 - Other - as specified
Due 26 June 2006
Resolved 22 June 2006
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 30 May 2006 Resolved
Prove periodic servicing of hydrostatic release and unit must be marked with 2 year expiration date.
Action required: 705 - Other - as specified
Due 26 June 2006
Resolved 22 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 May 2006 Resolved
Remove dead end wires from old stove area 46 CFR 183.200
Action required: 705 - Other - as specified
Due 26 June 2006
Resolved 22 June 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 May 2006 Resolved
Provide updated first aid kit 46 CFR 184.710
Action required: 705 - Other - as specified
Due 26 June 2006
Resolved 22 June 2006
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 30 May 2006 Resolved
Provide updated notice to mariners.
Action required: 705 - Other - as specified
Due 26 June 2006
Resolved 22 June 2006
Personnel › Training › First Aid/CPR
Issued 30 May 2006 Resolved
Prove proper first aid training to 50% of deckhands in guidance with NVIC 1-91
Action required: 705 - Other - as specified
Due 26 June 2006
Resolved 22 June 2006
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 May 2006 Resolved
Put new retro tape on 4 life jackets, rign bouy and on BA's. Retro currently on these is wearing out and has not reflective material left.
Action required: 705 - Other - as specified
Due 26 June 2006
Resolved 22 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2005 Resolved
Properly wire all electrical connections throughout the vessel making sure they are properly secured and terminating with in junction boxes.
Action required: 705 - Other - as specified
Due 14 September 2005
Resolved 16 June 2006
Electrical › Electric Generation Source (service) › Panelboard
Issued 16 May 2005 Resolved
Provide cover for electrical connections located in diesel machinery space.
Action required: 705 - Other - as specified
Due 14 September 2005
Resolved 26 May 2006
Resolution: Covers for electrical connections were in place.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 16 May 2005 Resolved
Provide weak link for IBA's.
Action required: 705 - Other - as specified
Resolved 15 July 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 May 2005 Resolved
Update and provide copy of certificate of documentation.
Action required: 705 - Other - as specified
Resolved 14 June 2005
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 16 May 2005 Resolved
Provide DAPI program information.
Action required: 705 - Other - as specified
Resolved 31 May 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 16 May 2005 Resolved
Have logs and training logs ready and up to date.
Action required: 705 - Other - as specified
Resolved 31 May 2005
Communications › Audible Communications › Horn/Whistle
Issued 16 May 2005 Resolved
Install ships whistle and bell.
Action required: 705 - Other - as specified
Resolved 31 May 2005
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 16 May 2005 Resolved
Remove rubber trash cans and provid non- flammable type.
Action required: 705 - Other - as specified
Resolved 31 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 May 2005 Resolved
Have on board an Coast Guard approved first aid kit.
Action required: 705 - Other - as specified
Resolved 31 May 2005
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 16 May 2005 Resolved
Lock valve on overboard discharge line for sewage
Action required: 705 - Other - as specified
Resolved 31 May 2005
Engineering › Bilge Water Management System › Piping
Issued 16 May 2005 Resolved
Reduce the amount of water in the aft bilge.
Action required: 705 - Other - as specified
Resolved 31 May 2005
Stability › Watertight Integrity › Deadlight Cover
Issued 16 May 2005 Resolved
Check and replace all gaskets on portholes. Gaskets are severely deteriorated.
Action required: 705 - Other - as specified
Resolved 31 May 2005
Construction/Loadline › Structures › Superstructure
Issued 16 May 2005 Resolved
Renew yoke on gaff since it is broken and several mast hoops are cracked or broken.
Action required: 705 - Other - as specified
Resolved 31 May 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 July 2004 Resolved
Properly splice fore peak electrical wires.
Due 6 August 2004
Resolved 3 August 2004
Personnel › Certificates/Documents/Licenses › License, Master
Issued 9 July 2004 Resolved
Ensure Master's and radio licenses are onboard.
Due 6 August 2004
Resolved 3 August 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 July 2004 Resolved
Secure raw water discharge hose.
Condition: Improper/Lack of Maintenance
Due 6 August 2004
Resolved 3 August 2004
Engineering › Fuel Oil Service System › Hose
Issued 9 July 2004 Resolved
Replace fuel oil return line.
Condition: Improper/Lack of Maintenance
Due 6 August 2004
Resolved 3 August 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 July 2004 Resolved
Double hose clamp engine raw water lines.
Condition: Improper/Lack of Maintenance
Due 6 August 2004
Resolved 3 August 2004
Engineering › Fuel Oil Service System › Valve
Issued 9 July 2004 Resolved
Install fuel shut-off valve at the engine.
Condition: Placed in Improper Service
Due 6 August 2004
Resolved 3 August 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 July 2004 Resolved
Install vessel's name and retro tape on lifering/lifebuoy.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2004
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 9 July 2004 Resolved
Foundation mounting bolts were loose and engine would move when engaged in forward or reverse.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2004
Resolution: Bolts were tightened and system was tested.
Communications › Audible Communications
Issued 24 June 2003 Resolved
Install a P/A system in the vessel's cabin area. LEGACY COMPONENT DESC: P/A System
Condition: Improper/Lack of Maintenance
Due 27 July 2003
Resolved 18 July 2003
Engineering › Bilge Water Management System
Issued 24 June 2003 Resolved
Replace aft bilge pump with an U/L approved one. LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Due 27 July 2003
Resolved 18 July 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 24 June 2003 Resolved
Post lifejacket donning instructions. LEGACY COMPONENT DESC: Donning Instructions
Condition: Improper/Lack of Maintenance
Due 27 July 2003
Resolved 18 July 2003
Documentation › Safety/Response Plans/Programs
Issued 24 June 2003 Resolved
Post stability letter. LEGACY COMPONENT DESC: Stability letter
Condition: Improper/Lack of Maintenance
Due 24 June 2003
Resolved 24 June 2003
Navigation › Piloting/Steering
Issued 24 June 2003 Resolved
Ensure vessel has current Nav. rules, Light List, and Coast Pilot. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Improper/Lack of Maintenance
Due 24 June 2003
Resolved 24 June 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 24 June 2003 Resolved
Properly support the fuel line in the steering compartment. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Due 24 June 2003
Resolved 24 June 2003
Fire Fighting
Issued 1 July 2002 Resolved
DIESEL ENGINE DID NOT AUTO SECURE WHEN FIXED F/F SYSTEM TESTED, SHUTDOWN MANUALLY FROM REMOTE LOCATION.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2002
Resolution: NEW SHUTDOWN SOLENOID INSTALLED, AUTO SHUTDOWN TESTED SAT
Engineering
Issued 8 June 2000 Resolved
Demonstrate proper operation of engine shut down switch.
Condition: Unknown
Due 3 July 2000
Resolved 3 July 2000
Lifesaving
Issued 8 June 2000 Resolved
Conduct man overboard and fire drill to satisfaction of attending Marine Instructor.
Condition: Unknown
Due 3 July 2000
Resolved 3 July 2000
Lifesaving
Issued 8 June 2000 Resolved
Provide proof of EPIRB registration.
Condition: Unknown
Due 3 July 2000
Resolved 3 July 2000
Fire Fighting
Issued 22 June 1999 Resolved
SHOW/PROVE PROPER OPERATION/INSTALLATION OF FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 30 June 1999
Resolved 7 July 1999
Documentation
Issued 22 June 1999 Resolved
SHOW PROPER EVIDENCE OF SUPERVISOR SUCCESSFULLY COMPLETING 60 MINUTES OF SUPERVISORY TRAINING.
Condition: Unknown
Due 22 June 1999
Resolved 22 June 1999
Deck/Cargo
Issued 22 June 1999 Resolved
PROVE PROPER OPERATION OF ANCHOR WINDLESS
Condition: Unknown
Due 30 June 1999
Resolved 7 July 1999
Construction/Loadline
Issued 22 June 1999 Resolved
PROVE PROPER OPERATION OF AUTOMATIC BILGE PUMP VISUAL INDICATORS.
Condition: Unknown
Due 30 June 1999
Resolved 7 July 1999
Unknown
Issued 19 June 1998 Resolved
Provide proof of compliance with USCG Chemical testing program. Specifically, employee assistance info and MIS report filing.
Condition: Unknown
Due 19 July 1998
Resolved 27 July 1998
Documentation
Issued 19 June 1998 Resolved
Provide proof of GLA inspection for vessel's 2 VHF radios.
Condition: Unknown
Due 19 July 1998
Resolved 27 July 1998
Navigation
Issued 18 April 1996 Resolved
Provide .6 meter day shape.
Condition: Unknown
Due 19 April 1996
Resolved 19 April 1996
Lifesaving
Issued 18 April 1996 Resolved
Provide rope ladder for retrieval purposes in man overboard drill.
Condition: Unknown
Due 19 April 1996
Resolved 19 April 1996
Documentation
Issued 18 April 1996 Resolved
Provide MARPOL V garbage plan.
Condition: Unknown
Due 19 April 1996
Resolved 19 April 1996
Documentation
Issued 18 April 1996 Resolved
Provide Comms Act Safety Radiotelephony Certificate.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Lifesaving
Issued 18 April 1996 Resolved
provide floating electric water light for 15 man life float.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Documentation
Issued 18 April 1996 Resolved
Provide original copy of COI for endorsement
Condition: Unknown
Due 23 April 1996
Resolved 19 April 1996
Lifesaving
Issued 18 April 1996 Resolved
provide PFD stowage label for 6 adult PFD's.
Condition: Unknown
Due 23 April 1996
Resolved 19 April 1996
Lifesaving
Issued 18 April 1996 Resolved
provide 2 four foot paddles for ecah life float._x001C_
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Engineering
Issued 18 April 1996 Resolved
Provide flame bowl for Dahl fuel filters in engine room.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Fire Fighting
Issued 18 April 1996 Resolved
Provide servicing of B-II portable extinguisher in main salon.
Condition: Unknown
Due 19 April 1996
Resolved 19 April 1996
Navigation
Issued 18 April 1996 Resolved
Properly align mast head light in accordance with nav rules.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Lifesaving
Issued 18 April 1996 Resolved
Provide 3 currently dated red flares.
Condition: Unknown
Due 19 April 1996
Resolved 19 April 1996
Lifesaving
Issued 18 April 1995 Resolved
Bouyant apparatus not float free.
Condition: Unknown
Due 26 April 1995
Resolved 10 May 1995
Lifesaving
Issued 28 January 1993 Resolved
PROVIDE 6 RED FLARES AND 6 ORANGE SMOKES.
Condition: Unknown
Due 28 January 1993
Resolved 28 January 1993
Lifesaving
Issued 28 January 1993 Resolved
RENEW THE MAN OVERBOARD POLE.
Condition: Unknown
Due 28 January 1993
Resolved 28 January 1993
Engineering
Issued 28 January 1993 Resolved
REPAIR EMERGENCY FUEL CUT OFF VALVE HANDLE.
Condition: Unknown
Due 28 January 1993
Resolved 28 January 1993
Accommodation/Occupational Safety
Issued 15 April 1992 Resolved
PROVIDE ADEQUATE DEVICE TO KEEP PASSENGERS OFF OF THE DECK AREAS ON THE FORE AND AFT WEATHER DECK WHERE THERE ARE NO HAND RAILS PROVIDED.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Deck/Cargo
Issued 15 April 1992 Resolved
MAKE REPAIR TO ELECTRIC ANCHOR WINDLASS AND MAKE READY FOR OPERATIONAL TEST.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Fire Fighting
Issued 15 April 1992 Resolved
PROPERLY SERVICE ALL HAND PORTABLE EXTINGUISHERS.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Navigation
Issued 15 April 1992 Resolved
PROVIDE CONICAL DAYSHAPE TO DISPLAY WHEN VESSEL OPERATES IN MOTOR SAILING MODE.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Navigation
Issued 15 April 1992 Resolved
MAKE REPAIR TO PORT RUNNING LIGHT TO FIX BULB INTO FOCAL PLANE OF THE LENSE.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Lifesaving
Issued 15 April 1992 Resolved
PROVIDE REQUIRED 60 FEET OF LINE TO LIFE RING.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Documentation
Issued 15 April 1992 Resolved
PROVIDE DOCUMENTATION TO SUPPORT COMPLIANCE WITH THE PROGRAM FOR CHEMICAL DRUG AND ALCOHOL TESTING OF COMMERCIAL VESSEL PERSONNEL IN ACCORDANCE WITH 46 CFR 16.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Accommodation/Occupational Safety
Issued 15 April 1992 Resolved
SECURE OVERBOARD DISCHARGE VALVE TO THE MSD WITH A CHAIN AND LOCK.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Engineering
Issued 24 January 1991 Resolved
RE-INSTALL SALIS TO CONFIRM UES/SUITABILITY
Condition: Unknown
Due 24 January 1991
Resolved 24 January 1991
Documentation
Issued 24 January 1991 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 January 1991
Resolved 24 January 1991
Navigation
Issued 24 January 1991 Resolved
GET BESSEL UNDERWAY WITH CREW AND CONDUCT DRILLS TO COAST GUARD SATISFACTION
Condition: Unknown
Due 24 January 1991
Resolved 24 January 1991
Deck/Cargo
Issued 24 January 1991 Resolved
REPAIR BILGE PUMP IN AFT SALON
Condition: Unknown
Due 24 January 1991
Resolved 24 January 1991
Lifesaving
Issued 24 January 1991 Resolved
PROVIDE 6 DATED NIGHT FLARES
Condition: Unknown
Due 24 January 1991
Resolved 24 January 1991
Accommodation/Occupational Safety
Issued 24 January 1991 Resolved
PROVIDE DOCUMENTATION OF MSD HOLDING TANK CAPACITY
Condition: Unknown
Due 24 January 1991
Resolved 24 January 1991
Navigation
Issued 24 January 1991 Resolved
RE-INSTALL AND PROVE OPERATION OF NAVIGATION LIGHTS
Condition: Unknown
Due 24 January 1991
Resolved 24 January 1991
Unknown
Issued 10 October 1989 Resolved
PAINT NAME ON VESSEL'S BOW.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Unknown
Issued 10 October 1989 Resolved
PROVIDE FUEL TANK VENT WITH 30 X 30 MESH FLAME SCREEN.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Fire Fighting
Issued 10 October 1989 Resolved
PORTABLE FIRE EXTINGUISHERS LAST SERVICED MAY88. PROVIDE SERVICING REPORT FOR ALL PORTABLE EXTINGUISHERS.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Lifesaving
Issued 10 October 1989 Resolved
PROVIDE 6 HAND DAY AND 6 HAND NIGHT FLARES OR 12 HAND COMBINATION DAY/NIGHTFLARES.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Navigation
Issued 10 October 1989 Resolved
RENEW OR REPAIR STERNLIGHT.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Unknown
Issued 10 October 1989 Resolved
REPLACE FUEL TANK SUPPORT WEDGES.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Lifesaving
Issued 10 October 1989 Resolved
CHANGE AND RENEW ALL BATTERIES IN WATERLIGHTS.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Lifesaving
Issued 10 October 1989 Resolved
RENEW RING BUOY WITH PROPER MARKINGS.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Navigation
Issued 10 October 1989 Resolved
REPAIR STARBOARD SIDELIGHT LIGHT BOARD.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Electrical
Issued 10 October 1989 Resolved
REPAIR SHORETIE CONNECTION.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Documentation
Issued 13 May 1988 Resolved
PROVIDE COPY OF FCC FORM 824, VESSEL RESTRICTED TO OPERATION WITHIN 1000 FTFROM SHORE UNTIL CORRECTED.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Fire Fighting
Issued 13 May 1988 Resolved
PRIOR TO OPERATION, SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Fire Fighting
Issued 13 May 1988 Resolved
PRIOR TO OPERATION, PROVIDE HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Documentation
Issued 13 May 1988 Resolved
IN ACCORDANCE WITH STABILITY LETTER, VESSEL IS RESTRICTED TO CARRIAGE OF UPTO 49 PASSENGERS.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Lifesaving
Issued 13 May 1988 Resolved
PROVIDE 7 ADDITIONAL (53 TOTAL) ADULT LIFE-JACKETS PROPERLY STENCILED AND RETROED. PASSENGER TOTAL RESTRICTED TO 42 UNTIL CORRECTED.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Lifesaving
Issued 13 May 1988 Resolved
PRIOR TO OPERATION, REPAIR/REPLACE RING BOUY.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Lifesaving
Issued 12 February 1987 Resolved
MARK BOUYANT APPARATUS WITH CAPACITY AND HAILING PORT IN AT LEAST 1.5 INCH LETTERS. MARK LIFE RING WITH HAILING PORT IN AT LEAST 2 INCH LETTERS.
Condition: Unknown
Due 12 February 1987
Resolved 12 February 1987
Navigation
Issued 12 February 1987 Resolved
PAINT RUNNING LIGHT SCREENS MATT BLACK( OUTBOARD SURFACE).
Condition: Unknown
Due 12 February 1987
Resolved 12 February 1987
Accommodation/Occupational Safety
Issued 12 February 1987 Resolved
ADD STANCHIONS PORT AND STBD SIDES AT DECK STEP TO INCREASE HEIGTH OF LIFE-LINES. ADD STANCHIONS BETWEEN GANGWAY ENTRANCE AND STAYS TO PROVIDE MORE SUPPORT FOR LIFELINES PORT AND STBD SIDES.
Condition: Unknown
Due 12 February 1987
Resolved 12 February 1987
Lifesaving
Issued 12 February 1987 Resolved
PROPERLY ATTACH PAINTER FOR BOUYANT APPARATUS TO VESSEL VIA WEAK LINK.
Condition: Unknown
Due 12 February 1987
Resolved 12 February 1987
Construction/Loadline
Issued 9 December 1986 Resolved
SUBMIT TO [name withheld], AL A COMPLETE SET OF "AS BUILT" PLANS FOR REVIEW PRIOR TO 01APR87.
Condition: Unknown
Due 9 December 1986
Resolved 9 December 1986
Documentation
Issued 9 December 1986 Resolved
PROVIDE A RADIOTELEPHONY CERTIFICATE ABOARD.
Condition: Unknown
Due 9 December 1986
Resolved 9 December 1986
Documentation
Issued 9 December 1986 Resolved
PROVIDE A FCC RADIO STATION LICENSE ABOARD.
Condition: Unknown
Due 9 December 1986
Resolved 9 December 1986
Accommodation/Occupational Safety
Issued 9 December 1986 Resolved
PROVIDE GUARD RAILS AROUND THE STOVE VENT ON TOP OF MAIN CABIN.
Condition: Unknown
Due 9 December 1986
Resolved 9 December 1986
Documentation
Issued 9 December 1986 Resolved
POST REQUIRED LICENSES: I.E. 3RD CLASS RADIO OPERATORS LICENSE, OCEAN OPERATORS LICENSE, DOCUMENT, STABILITY LETTER, CERTIFICATE OF INSPECTION, FCC STATION LICENSE, RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 9 December 1986
Resolved 9 December 1986

Casualty record · 4

9 June 2006Routine · role: Involved in a Marine Casualty · activity 2689460
19 July 2008Routine · role: Involved in a Marine Casualty · activity 3339540
23 July 2008Routine · role: Involved in a Marine Casualty · activity 3339584
15 December 2022Routine · role: Involved in a Marine Casualty · activity 7610003
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

RED WITCH (2006–2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.