MAURY USCG vessel records Sign in
← All vessels

MARE DORO

MARE DORO is a 1985 freight ship. The Coast Guard has recorded 19 inspections since 1986, most recently in July 2012, along with 10 deficiencies — 5 with no resolution recorded — and 3 operational controls, 1 with no removal date recorded.

Records from 1986 to 2012. Most recent: inspection, 27 July 2012.

Built
1985
Last inspected
27 July 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8401298 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
275950
Flag
INDIA
—
Maury page id
psix-275950

Inspections, by type

…with no type recorded14
…past their stated due date5
Years with a record 10 calendar years (1986–2012)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it13871 - Convention (Subpart B), Net Ton
42628 - Dead Weight, Ton
49967 - Displacement, Ton
24639 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

27 July 2012 ISPS I Exam · PI Safety Exam · Ballast Water Examination · COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4383284
24 July 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4388671
23 July 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4384209
23 July 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4389206
13 September 2005 MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2492141
3 March 2004 Passenger/Freight Vessel Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2017018
1 March 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2016149
30 July 2003 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1861331
15 December 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1718891
15 November 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 493646
12 November 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 179407
10 November 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 362232
5 November 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 362153
6 April 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 357255
17 January 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 529900
26 September 1990 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 339318
8 November 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 326719
9 March 1987 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 450486
28 December 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 313555

Deficiency record · 10

Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 27 July 2012 No resolution recorded
0715-Detection- Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed a plastic bag over flame detector in engineering workshop. -SOLAS 74 am II-2/14
Action required: 705 - Other - as specified
Due 27 August 2012 — due date passed with no resolution recorded
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 27 July 2012 No resolution recorded
0715-Detection- Fire protection systems and fire-fighting systems and appliances shall be properly tested and inspected. C/E stated that the vessel has no test medium for flame detector on board the ship. Provide corrective action plan attesting to maintenance of fire detection systems. -SOLAS 74 am II-2/14
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 July 2012 — due date passed with no resolution recorded
Engineering › Lubricating Oil Service System › Tank
Issued 27 July 2012 No resolution recorded
0710-Fire prevention- The arrangements for the storage of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and person on board. PSCO observed a modified 55 gallon drum of low sulfur cylinder oil installed into the ships lubricating system. -SOLAS 74 am II-2/4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 July 2012 — due date passed with no resolution recorded
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 27 July 2012 No resolution recorded
1510-Navigation equipment- To assist in casualty investigations, cargo ships shall be fitted with a VDR which may a SVDR. PSCO observed an Audio 2 failure and capsule failure alarms on SVDR. -SOLAS 74 am V/20
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 July 2012 — due date passed with no resolution recorded
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 27 July 2012 No resolution recorded
0899-Other (acid prevention0- Each bunker line transfer pipe must be hydrostatically tested at least 1.5 MAWP. -33 CFR 156.170
Action required: 703 - Prior to bunkering operations
Due 29 July 2012 — due date passed with no resolution recorded
Construction/Loadline › Markings
Issued 3 March 2004 Resolved
paint load line markings a contrasting color to the hull to the satisfaction of class w/in 30 days. LEGACY COMPONENT DESC: Load Line Mark
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 3 March 2004
Resolution: Recieved class report attesting to proper repairs
Deck/Cargo › Holds/Tanks
Issued 3 March 2004 Resolved
make permanent repairs to bracket on #3 cargo hold, port side aft to the satisfaction of class w/in 30 days. LEGACY COMPONENT DESC: Coaming
Action required: 705 - Other - as specified
Due 4 April 2004
Resolved 10 March 2004
Resolution: Received class report attesting to proper repairs
Fire Fighting › Emergency Fire Pumps
Issued 15 December 2002 Resolved
EMERGENCY FIRE PUMP DOES NOT HAVE PRESSURE NOR SUCTION TO PROVIDE WATER DISCHARGE THROUGH FIRE MAIN INTO 2 HOSES, A VIOLATION OF SOLAS 74/78 II-2/2. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 December 2002
Resolved 16 December 2002
Resolution: CONDUCTED PSC FOLLOW-UP. CLEARED DEFICIENCY.
Navigation
Issued 26 September 1990 Resolved
UPON INSPECTION OF VSLS CHARTS OF THE AREA IT WAS NOTED CHARTS WERE NOT _x001C_ CURRENTLY CORRECTED IAW 33CFR164.33(a)(1)(ii)
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Navigation
Issued 28 December 1986 Resolved
NOS CHARTS 18720, 18740, 18746, 18749 AND 18751 NOT CORRECTED UP TO DATE. USCG LIGHT LIST VOL. III NOT CORRECTED TO DATE.
Condition: Unknown
Due 28 December 1986
Resolved 28 December 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.