MARINA HORNBLOWER
MARINA HORNBLOWER is a 1986 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in October 2025, along with 29 deficiencies, 3 operational controls and 2 casualty investigations between 2012 and 2016.
Records from 2012 to 2025. Most recent: inspection, 7 October 2025.
- Built
- 1986
- Last inspected
- 7 October 2025
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 29 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2012–2016
Identity
907063
WDE3327
275994
Flag
UNITED STATES
Maury page id
psix-275994
Inspections, by type
…with no type recorded1
Years with a record
10 calendar years (2016–2025)
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Registered dimensions (L × B × D)69.0 ft × 24.8 ft × 6.5 ft
Registered tonnagegross 82 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHILLS MARINE · SEAL BEACH, CA, UNITED STATES · built 1986
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMARINA DEL REY, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 6 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 22
7 October 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8064870
10 September 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7843506
19 September 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7606287
17 May 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7675581
20 March 2023
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7606492
20 October 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7484354
6 August 2021
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7278609
5 August 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7278333
10 March 2021
Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7153174
1 December 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7103708
25 June 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6926234
26 July 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6763129
31 October 2018
Plan Review (Other than "T") · Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6559590
13 December 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6323649
28 November 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6299037
6 January 2017
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6073144
29 December 2016
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6040768
15 November 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6040752
6 July 2016
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5939472
5 July 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5983458
29 March 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5822226
4 February 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5809504
Deficiency record · 29
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 September 2023
Resolved
Bilge high water alarm in lazarette failed to provide a visual indicator at the operating station. Needs repair.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 March 2023
Resolved
Provide documentation on identified newly installed fire insulation in engine room. If no documentation, install appropriate fire installation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 March 2023
Resolved
Identified top deck middle rail slightly worn. Reinforce affected area.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 October 2022
Resolved
Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. STBD Generator fuel filtwe flame bowl has an unapproved flame shield plug.
46 CFR 119.455
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 October 2022
Resolved
The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. MI discovered deteriorated fire protection insulation located above stbd main engine.
46 CFR 116.405 (a)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 October 2022
Resolved
All cable and wire must: Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart. Electrical cable IVO STBD engine has cables that are not properly secured.
46 CFR 120.340(b)(4)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 October 2022
Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards. MI discovered two dead end wires above STBD engine electrical cable run.
46 CFR 120.200(b)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 October 2022
Resolved
The installation and location must be to the satisfaction of the cognizant [name withheld] do not secure 02 fire extingushers within galley.
46 CFR 118.520
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 October 2022
Resolved
Electrical equipment on a vessel must be installed and maintained: MI discorved unapproved power strip on bridge and port stairway. Loose wire nut connected to bus panel under bridge console.
46 CFR 120.200(a)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 August 2021
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. Observed wheelhouse and galley panels with open access to exposed wiring. Switch found with open front in galley.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 August 2021
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date of the COI. Vessel exceeded 3 month interval on 31MAR2021. Vessel is required to complete a satisfactory annual inspection prior to carrying passengers.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 December 2020
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has not completed drydock examination IAW the required timeline. Vessel must complete an examination for credit drydock prior to the carriage of passengers.
46 CFR 115.600(c)(1); 701c
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 25 June 2020
Resolved
Each window and its means of attachment to the hull or deckhouse must be capable of withstanding the maximum load from wave and wind conditions. 02 windows at the operating station had small cracks around the edges. Replace cracked windows.
46 CFR 116.1020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 June 2020
Resolved
Minimum capacity of the fire pump shall be 50 gpm at a pressure of not less than 60 psi at the outlet. Fire pump pressure was not rising above 40-45 psi. Prove proper pressure at the fire pump outlet.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 June 2020
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate high water level. The light on the high bilge alarm for the lazarette is inoperable. Prove proper operation of the lazarette high bilge alarm.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 June 2020
Resolved
A power-driven vessel underway shall exhibit: A stern light. The stern light was found to be inoperable. Prove proper operation of stern light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2020
Resolved
The [fuel] shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The stbd fuel shutoff valve was initially inaccessible due to chair storage over the cover for the valve reach rod. When crew got to the valve, upon turning it, the reach rod broke. Prove proper operation of the valve from outside the space, and ensure the accessibility of the valve.
46 CFR 182.20-40(b)(3)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 July 2019
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel exceeded 3 month interval on 29MAR019. Vessel required to undergo satisfactory annual inspection prior to carrying passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2019
Resolved
shut off valves installed so as to be fitted in the fuel supply lines to stop fuel flow. Stbd fuel oil shut off is inoperable. Repair or replace shut off valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 November 2018
Resolved
MAKE CORRECTIONS TO DVTP'S AS DISCUSSED AND SUBMIT TO MSC FOR APPROVAL.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 28 November 2017
Resolved
Properly label vessel name on the Port & STBD Bow as indicated.
Stability › Watertight Integrity › General
Issued 15 November 2016
Resolved
REPLACE PORT GENERATOR INTAKE FWD 2.5IN BALL VALVE THRU HULL.
Stability › Watertight Integrity › General
Issued 15 November 2016
Resolved
REPLACE STBD GENERATOR INTAKE AFT 2.5IN BALL VALVE THRU HULL.
Construction/Loadline › Hull › Longitudinal Frame
Issued 15 November 2016
Resolved
CROP + RENEW STBD LONGITUDINAL FRAME IN GALLEY AS INDICATED.
Construction/Loadline › Hull › Hull Plating
Issued 15 November 2016
Resolved
CROP + RENEW RUB RAIL AS INDICATED (PORT + STBD AMIDSHIP, STBD QUARTER).
Construction/Loadline › Hull › Side Shell
Issued 6 July 2016
Resolved
3' X 1/4" Gouge in hull 1' above waterline stbd side
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 29 March 2016
Resolved
Provide 41 adult and 01 child lifejackes, vessel restricted to 132 adult passengers and 18 children passengers.
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 5 February 2016
Resolved
Replace fire protection insulation in port side engine room as original
Construction/Loadline › Hull › Longitudinal Frame
Issued 5 February 2016
Resolved
Treat for minor termite damage as indicated in forepeak along deck center support beam, fuel compartment, and lazarette.
Casualty record · 2
22 July 2012Routine · role: Involved in a Marine Casualty · activity 4403238
5 July 2016Routine · role: Involved in a Marine Casualty · activity 5983458
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.