ISLAND SPIRIT III

ISLAND SPIRIT III is a 1986 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2016, most recently in May 2026, along with 38 deficiencies, 1 operational control and 2 casualty investigations between 2005 and 2014.

Records from 2005 to 2026. Most recent: inspection, 1 May 2026.

Built
1986
Last inspected
1 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP4129
276032
Flag
UNITED STATES
Maury page id
psix-276032

Documentation record

Registered dimensions (L × B × D)62.0 ft × 22.0 ft × 7.0 ft
Registered tonnagegross 83 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1986
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 7 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it83 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

25 inspections, each with its date, unit and type; 38 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; 2 other recorded names, with years; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 25

1 May 2026 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8361881
30 March 2026 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8334326
5 May 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8127575
7 February 2024 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7858425
30 January 2024 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7856086
26 January 2024 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7856121
29 August 2023 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7780075
22 May 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7692298
23 March 2023 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7654378
11 January 2023 Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 7619758
4 January 2023 Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7615632
26 December 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7613050
19 May 2022 Appeal
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7459643
5 April 2022 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7425076
4 November 2021 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7352064
26 May 2021 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7189207
22 April 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7180699
18 August 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7030087
19 November 2019 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6858185
30 September 2019 DAPI Audit · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6824833
4 September 2018 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6531363
30 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6297809
24 October 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6293807
1 August 2017 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6226972
15 June 2016 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5908544

Deficiency record · 38

05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 5 May 2025 Resolved
Properly label hydrostatic release.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 5 May 2025
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 February 2024 Resolved
Provide an additional 3 hand held flares.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 February 2024
Resolved 14 February 2024
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 August 2023 Resolved
When damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space. Vsl self reported allision with an aid to navigation in the vicinity of Morehead City/ Beufort, NC. Vsl must be made available for non-credit internal structural exam prior to resuming operations. 46 CFR 176.600(d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2023
Resolution: ISE Complete Neg Results
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 April 2022 Resolved
On passenger decks of vessels engaged in a ferry or excursion type operation, rails shall be at least 42 inches high. The space below the rail shall be fitted with bulwarks, chain link fencing, wire mesh, or the equivalent. During New to Zone/Annual inspection, MI's verified with owner/operator the intended service for the vessel. The vessel will be conducting a combination of excursion and fishing trips. MI's verified deck is rail height is 36 inches throughout vessel. Submit plans to local OCMI for approval prior to making any modifications/repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2022
Resolved 11 January 2023
Resolution: Vessel's owner appealed requirement. January 11, 2023, D5 approved appeal, see MISLE activities: 7619758, 7459643 and 7425076 for details.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 26 May 2021 Resolved
Place registration sticker on EPIRB
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 2 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 May 2021 Resolved
Replace leaking coolant hose on Port MDE
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 26 May 2021
Resolved 26 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 August 2020 Resolved
Identified batteries installed in all floating electric water lights not IAW approved batteries listed on the floating electric water light. Issued code 705-Other for restriction of operations to less than 3 miles from shore until EPIRB is satisfactory
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 9 September 2020
Resolution: RCVD scanned receipt of newly correct purchased batteries.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 18 August 2020 Resolved
Restrict operations to less than 3 miles from shore. EPIRB battery expired 1-20-2020
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 September 2020
Resolved 9 September 2020
Resolution: RCVD reciept amnd photograph of newly purchased EPIRB. O/O sent over EPIRB registration form for new EPIRB
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 30 September 2019 Resolved
Secure Sewage overboard discharge valve by closing and removing the handle, padlock, or non releasable wire tie.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 24 October 2019
Resolution: valve was padlocked
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2019 Resolved
Update circuit labeling in distribution panel on forward bulkhead of engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 24 October 2019
Resolution: Operator provided photo of labled panel
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 September 2019 Resolved
Stow all portable fire extinguishers with approved bracket as denoted on the extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 24 October 2019
Resolution: Operator provided photos of all extiguishers and brackets
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 September 2019 Resolved
Install fire stop in wire run from fishing pole hold to forward life jacket storage compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 24 October 2019
Resolution: operator provided photos of repair
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 30 September 2019 Resolved
Renew lines for all 4 life float lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 24 October 2019
Resolution: operator provided photo of installed lines
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 September 2019 Resolved
Owner agreed to replace 2 dated life float lights, replace and date batteries in all 4, and log battery installation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 24 October 2019
Resolution: operator provided photo of new lights and marked battery install dates on all 4 lights
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 September 2019 Resolved
install 2-A portable fire extinguisher in concession area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 24 October 2019
Resolution: operator provided photo of extinguisher in approved bracket
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2019 Resolved
install water contamination prevention device and 30x30 mesh at the termination of the fuel tank vent.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 24 October 2019
Resolution: operator provided photo of new fitting.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 30 September 2019 Resolved
Provide on board the most recent editions of navigation publications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 24 October 2019
Resolution: operator provided photo of all 2019 publications
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 September 2019 Resolved
Place on board 01 child life jacket and 02 adult life jackets. Total passenger count is reduced to 147 adults until replacement is complete.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 24 October 2019
Resolution: operator provided photo of new life jackets
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 September 2018 Resolved
46 CFR 182.100 ALL MACHINERY AND EQUIPMENT MUST BE INSTALLED AND MAINTAINED TO AFFORD ADEQUATE PROTECTION FROM CAUSING FIRE AND PERSONNEL INJURY. THE FOLLOWING DEFICIENCIES WERE IDENTIFIED: (1) 04 DEAD END WIRES ON TOP DECK. REMOVE. (2) ZIP TIED ELECTRICAL CABLING SUPPORTS FOUND THROUGHOUT SHIP. REPLACE WITH METAL SUPPORTS IN SUCH A MANNER TO AVOID CHAFING. (3) NUMEROUS DEAD END WIRES AND LEADS NO LONGER SUPPLYING POWER TO BRIDGE EQUIPMENT FOUND. REMOVE. (4) ALL SAE J-1942 FLEXIBLE NON-METALLIC HOSE USED IN LUBRICATION OIL LINES FOUND CHAFING WHERE IN CONTACT WITH VIBRATING SURFACES. AFFIX WITH CHAFING GEAR WHERE IN CONTACT.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 10 October 2018
Resolution: Wires housed in junction boxes and hoses fitted with chaffing gear.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 September 2018 Resolved
46 CFR 183.324(c) GROUND DETECTION MUST BE PROVIDED. GROUND DETECTION SYSTEM FOUND WITH 2 AMP GROUND AND GAUGE NOT FULLY FUNCTIONAL. ISOLATE AND RECTIFY GROUND. REPLACE GAUGE IN KIND. ****DUE IN SEVEN DAYS 9/12/2018****
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2018
Resolved 10 October 2018
Resolution: Gauge replaced and tested sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 September 2018 Resolved
46 CFR 176.800(a) ARRANGEMENTS MAY BE INSPECTED IN ACCORDANCE WITH THE STANDARDS ACCEPTABLE TO THE [name withheld] OFF VALVE DECAL NOT LOCATED ADJACENT TO PULL MECHANISM. POST DECAL ADJACENT TO FULL SHUT OFF PUEL MECHANISM.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2018
Resolved 10 October 2018
Resolution: Pull cable identified and labeled correctly on bulkhead.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ship's occupational safety and health policies and programmes
Issued 4 September 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2018
Resolution: RESOLVED VIA CORRESPONDENCE WITH LEAD INSPECTOR.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 4 September 2018 Resolved
46 CFR 40.11 VESSEL MUST HAVE ONBOARD A FCC ISSUED SAFETY CERTIFICATE TO PROVE INSTALLATION OF RADIO TRANSMITTING EQUIPMENT.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 10 October 2018
Resolution: FCC Tech completed radio suite tests and issued certificates.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 September 2018 Resolved
46 CFR 185.728 ACH EPIRB MUST BE TESTED MONTHLY. TEST SHALL BE LOGGED.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2018
Resolution: RESOLVED VIA CORRESPONDENCE WITH LEAD INSPECTOR.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 4 September 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2018
Resolution: RESOLVED VIA CORRESPONDENCE WITH LEAD INSPECTOR.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Minimum requirements)
Issued 4 September 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2018
Resolved 10 October 2018
Resolution: Operator purchased new first aid kits.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 September 2018 Resolved
46 CFR 185.614 PORTABLE WATER TIGHT CONTAINERS FOR DISTRESS FLARES SHALL BE CLEARLY MARKED "DISTRESS SIGNALS" .5" HIGH. CONTAINER IMPROPERLY MARKED. MARK AS REQURIED.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2018
Resolved 10 October 2018
Resolution: Container labeled correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 September 2018 Resolved
46 CFR 185.700(a) EACH SURVIVAL CRAFT MUST BE IN GOOD WORKING ORDER AND READY FOR IMMEDIATE USE AT ALL TIMES UNDERWAY. SURVIVAL CRAFTS RETRO-TAPE IS WASTED. REPLACE WITH SOLAS TAPE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2018
Resolution: RESOLVED VIA CORRESPONDENCE WITH LEAD INSPECTOR.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 September 2018 Resolved
46 CFR 180.71(a) AN ADULT LIFE JACKET MUST BE PROVIDED FOR EACH PERSON CARRIED ONBOARD. MISSING 06 LIFE JACKETS. REPLACE WITH COAST GUARD APPROVED LIFE JACKET ANALGOUS TO DONNING PLACARD. PASSENGER COUNT REDUCED TO 144 TILL CORRECTED.
Action required: 705 - Other - as specified
Resolved 10 October 2018
Resolution: Operator purchased new jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 September 2018 Resolved
46 CFR 180.70(d)(2) EACH RING LIFE BUOY WITH A FLOATING WATER LIGHT MUST HAVE A LANYARD OF ATLEAST 3' BUT NOT MORE THAN 6'. LANYARD IS LESS THAN 3'. REPLACE WITH PROPER LENGTH MARINE GRADE LINE AND CORROSION-RESISTANT CLIP.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2018
Resolution: RESOLVED VIA CORRESPONDENCE WITH LEAD INSPECTOR.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 September 2018 Resolved
46 CFR 180.70(b)(1) EACH RING LIFE BUOY ON A VESSEL MUST BE APPROVED IN ACCORDANCE WITH SUBCHAPTER Q. TWO LIFE RINGS HAVE WASTED GRAB LINES. REPLACE IN KIND.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2018
Resolution: RESOLVED VIA CORRESPONDENCE WITH LEAD INSPECTOR.
Communications › Radio Communications › EPIRB
Issued 1 August 2017 Resolved
Replace hydrostaic release for EPIRB. Vessel is resrticted to 3 miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 4 October 2017
Resolution: Attended vessel and verified installation of new hydrostatic release.
Lifesaving › Lifefloat › Serviceable
Issued 1 August 2017 Resolved
Repaint all life floats and patch 02 lifefloats. Vessel is resrticted to 3 miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 4 October 2017
Resolution: Attened vessel and verified repairs of all lifefloats.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 1 August 2017 Resolved
Provide 88 Type I PFD's with lights. Vessel is resrticted to 20 miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 4 October 2017
Resolution: Attened vessel and verified 88 PFD's with lights.
Construction/Loadline › Penetrations › Bottom Plug
Issued 15 June 2016 Resolved
Make permanent repairs to transducer plug in the #2 Compt port side. Current configuration has wood plug which is wasted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2016
Resolution: Vessel replaced wasted wood plug with plastic transducer plug.
Engineering › Bilge Water Management System › Piping
Issued 15 June 2016 Resolved
Make permanent repairs to the bilge piping in fwd compt and #2 compt and prove remaining bilge piping system is intact.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2016
Resolution: Completed satisfactory repairs to the bilge piping system, and pumped water overboard, thus proving its integrity.
Navigation › Piloting/Steering › Marine Charts
Issued 15 June 2016 Resolved
Vessel does not have current charts and nautical publications for intended area of operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2016
Resolution: Vessel is now carrying corrected navigational charts with required nav pubs.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 June 2016 Resolved
Demonstrate satisfactorily a man overboard drill to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2016
Resolution: Vessel's crew demonstrated a satisfactory man overboard drill to attending CG marine inspectors.

Casualty record · 2

12 August 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2463596
22 May 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4866238
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

CAPT. LOU VI (2005), CRYSTAL COAST LADY (2014). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.