MAURY USCG vessel records Sign in
← All vessels

MARATHON LADY

MARATHON LADY is a 1986 passenger vessel (inspected). The Coast Guard has recorded 63 inspections since 1986, most recently in September 2025, along with 77 deficiencies.

Records from 1986 to 2025. Most recent: inspection, 15 September 2025.

Built
1986
Last inspected
15 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI4017
276329
Flag
UNITED STATES
367073210
Maury page id
psix-276329

Inspections, by type

…with no type recorded4
Years with a record 35 calendar years (1986–2025)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 20.0 ft × 7.0 ft
Registered tonnagegross 60 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX BROTHERS ENTERPRIS · LOREAUVILLE, LA, UNITED STATES · built 1986
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMARATHON, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 20 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it60 - Simplified, Gross Ton
48 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI4017MMSI 367073210 · active · compulsorily equipped · granted 7 August 2025, expires 30 September 2035
WAP5155MMSI 367073210 · cancelled · compulsorily equipped · granted 22 October 2005, cancelled 17 September 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 63

15 September 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8170285
25 September 2024 Internal Structural Exam · COI Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7969580
3 October 2023 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7812981
5 October 2022 Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7572266
4 October 2021 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7326406
7 October 2020 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7074511
23 September 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7063689
24 September 2019 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6789345
25 September 2018 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6548512
24 October 2017 Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294301
20 October 2017 Internal Structural Exam · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294998
26 September 2016 Internal Structural Exam · Hull Examination · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6025941
6 October 2015 Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5234001
28 September 2011 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4158261
28 September 2010 COI Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3859595
22 September 2008 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3330402
18 September 2008 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3327255
14 September 2007 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3057378
21 May 2007 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2936065
15 August 2006 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2748961
1 November 2005 Re-Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2518318
16 May 2005 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2358870
14 October 2004 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2220197
21 October 2003 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1943154
1 October 2003 MARPOL Annex V Examination · Deficiency Check · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1899849
2 July 2003 Type not recorded
No type recorded · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1862056
8 May 2003 Welding Related Inspections Qualification Testing · Examination of Repairs · Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1788927
24 October 2002 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1695409
17 September 2002 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1674080
30 August 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1073219
20 August 2001 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1431091
16 May 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1384769
12 October 2000 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 823388
11 September 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1417122
18 October 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 797792
22 September 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1384254
1 September 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1119793
18 May 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1460305
19 August 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1131612
23 October 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 780387
26 September 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1115672
27 August 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 785145
4 September 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 940540
23 October 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 880970
24 August 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 879819
9 September 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1172303
16 December 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1159990
2 November 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1138351
22 September 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1149828
8 September 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 945861
13 February 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1005625
7 January 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1265931
5 September 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 925450
9 August 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1227728
19 March 1990 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 924796
22 September 1989 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1221388
24 April 1989 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1339503
27 October 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 890189
26 May 1988 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1208627
10 May 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1037803
10 March 1987 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1321043
9 March 1987 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1009659
18 November 1986 Initial Certification
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316910

Deficiency record · 77

11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 September 2025 Resolved
EMERGENCY PROCEDURES need to be posted on vessel for crew and passengers to be able to view.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2025
Resolved 22 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 September 2025 Resolved
Renew retro tape on the 10 person life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2025
Resolved 22 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2024 Resolved
Have fittings of brass or other suitable corrsion-resistant material that comply with NFPA 1963. Replace nozzle for the fire hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2024
Resolved 14 October 2024
Resolution: Vessel has purchased a new fire nozzle.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 October 2021 Resolved
Missing crew training log. Must provide proof of crew training for each new hire and for every 3 months.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 3 November 2021
Resolution: Received pictures showing crew training documented and signed by each crew member
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 4 October 2021 Resolved
Log for abandon ship, MOB and Fire drills are not being logged properly. Must make new log and enter info as required in 46 CFR 185.20 & 185.524
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2021
Resolved 3 November 2021
Resolution: Received pictures of drill logs properly filled out.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 4 October 2021 Resolved
[name withheld] was missing his FCC operators permit. Must provide proof of FCC operators permit for any Captain operating a vessel with more than 6 passengers. 47 CFR 80.159(e)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2021
Resolved 4 October 2021
Resolution: Sent picture of his FCC operators permit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 October 2020 Resolved
Update Coast Pilot and update charts.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 19 October 2020
Resolution: Printed out all new Coast Pilot and Light list. Bought new correct Nav Chart.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 October 2020 Resolved
Clean or replace stbd nav light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 19 October 2020
Resolution: Cleaned STBD side Nav light, Took picture at night time, all SAT
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 October 2020 Resolved
Bottom life float needs new reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 19 October 2020
Resolution: Replace retro on life float
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 October 2020 Resolved
Replace 01 adult life jacket. Passenger count is reduced by 1 until replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 19 October 2020
Resolution: Bought new life jacket and labeled with vessels name, showed receipt too.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 October 2020 Resolved
replaced. 180.71 Log MOB and Fire Drills as required.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 19 October 2020
Resolution: Showed new logs for drill and training to show all info required
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 October 2020 Resolved
Log EPIRB test monthly.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 19 October 2020
Resolution: Showed new log for monthly EPRIB test.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 23 September 2020 Resolved
Found pitting more than the 25 percent wastage allowed on port side hull about 1/3 of the way back around the sewage discharge pipe. Cut out and replace approx 12 inch section. 46 CFR 177.310
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2020
Resolved 28 September 2020
Resolution: cropped and renewed hull plate and 6 inches of pipe. Tested welds with 2800 psi pressure washer, All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 September 2020 Resolved
Replace port shaft strut cutless bearing and the STBD rudder cutless bearing. 46 CFR 176.610
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2020
Resolved 28 September 2020
Resolution: replaced with new bearings
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 September 2020 Resolved
Deck penatrations for anchor wiring needs to be resealed. 46 CFR 179.360
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2020
Resolved 28 September 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 September 2020 Resolved
Bulkhead penatrations need cleaned out and re sealed throught vessel 46 CFR 179.360
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2020
Resolved 28 September 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 23 September 2020 Resolved
STBD MDE STBD FWD motor mount has some pitting more that 25 percent. Gouge out and re weld pitts. 46 CFR 176.610
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2020
Resolved 28 September 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019 Resolved
All wires (conductors) shall be Marine grade or UL boat cable and of the stranded type, multiple wire runs were found to be solid copper cable (house wire). Remove and replace solid copper wires with Marine grade cables.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: All non boat/UL cables/wires removed and or replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 September 2019 Resolved
Make battery box lining available for re-inspection, boxes are corroded and holed at bottom.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Both battery boxes and lead lining replaced/repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019 Resolved
Provide insulated pressure type connectors at wire slices or splices shall be mechanically secure and made inside junction box and taped. (VHF radio, multiple connections behind operating station, and any other connections throughout vessel)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Proper connections utilized.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 September 2019 Resolved
Provide gaskets on main deck cabin doors to make them watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Gaskets added to both Aft and Portside doors.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 24 September 2019 Resolved
Provide positive shutoff valve on generator exhaust to prevent the back flow of water or permanently cap overboard penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Exhaust outlet properly plugged to the satisfaction of attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019 Resolved
Provide metal wire supports spaced not more than 24inches for all electrical wire runs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Vessels electrical system complies.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 September 2019 Resolved
Reinstall and ensure weak-link in life float is properly mounted so that painter-line is not obstructed and so that the full point load pull is directly on the weak link.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Weak link reconfigured to provide non-obstructed release.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 September 2019 Resolved
Fit each life float with a pair of paddles.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Paddles attached to each LF.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 September 2019 Resolved
Repair/replace fixed bilge metallic piping in forward compartment and lazarette compartment. Bilge piping is a vital system and required to be metallic. Flexible hoses found attached to bilge piping.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: All piping in Forward and Lazarette compartments were replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019 Resolved
Provide over current protection for windlass winch, over-current protection shall be rated or set at no more than 125 percent of the motor full-load current rating.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: 50amp inline thermal BLUESEAS breaker added within 24inches of battery terminal on the ungrounded circuit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 September 2019 Resolved
Replace flexible exhaust hose on secondary exhaust on Port Engine, hose found damaged at overboard penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Exhaust piping replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 September 2019 Resolved
Replace/repair electrical conduit under port main engine. Conduit found chaffed and exposed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Electrical conduit replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 September 2019 Resolved
STBD Power switch wire in way of main engine found with sharp bend and exposed wires. Repair/relocate switch to reduce bend in cable and repair wire insulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Switch mounting location relocated to prevent sharp bend, wire insulation repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019 Resolved
High water bilge alarms appeared to be wired with non Marine grade/boat cable, provide documentation that current wire is Marine Grade or replace wire using Boat cable or UL Marine cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Wire replaced with UL boat cable.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 September 2019 Resolved
Label high level indicators at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: HW labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 September 2018 Resolved
The float free link for the life floats does not comply with the requirement to be of sufficient breaking strenght for the combined capacity of all three floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 16 October 2018
Resolution: Float free link replaced with appropriate size.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 September 2018 Resolved
Emergency broadcast placard does not comply with 184.506
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 16 October 2018
Resolution: Emergency Broadcast placard replaced with appropriate verbiage.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 September 2018 Resolved
Vessel's vhf radio does not display lat and long
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 16 October 2018
Resolution: VHF radio repaired to display Lat and Long
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 25 September 2018 Resolved
Vessel must demonstrate that it can safely recover an incapacitated person. Plans must be submitted to provide arrangements and a drill must be conducted to show adequacy in the presence of a marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 16 October 2018
Resolution: Vessel made appropriate changes to procedures and equipment used to recover an unconscious person from the water.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 20 October 2017 Resolved
All 3 lifefloats strobe lights are broken and must be renewed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 3 November 2017
Resolution: Strobes were renewed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 October 2017 Resolved
AVH02: life ring is not serviceable, renew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 3 November 2017
Resolution: New strobe and life ring were provided. all sat.
Fire Fighting › Fire Hoses › Connections
Issued 20 October 2017 Resolved
AVH03: Fire hose is missing a nozzle. provide a non corrosive adjustable nozzle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 3 November 2017
Resolution: New fire nozzle was provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 October 2017 Resolved
AVH04: All charts, light list and Coast Pilot must be renewed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 3 November 2017
Resolution: New navigationn publications were provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 October 2017 Resolved
AVH05: First aid kit is missing contents. Provide contents per 46CFR160.041-4.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 3 November 2017
Resolution: New CG approved first aid kit was provided.
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 October 2017 Resolved
AVH06: Re-worked drill log and survival gear maintenance, per conversation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 3 November 2017
Resolution: Logs were changed to add survival gear and will be tracked monthly.
Engineering › Bilge Water Management System › Piping
Issued 28 September 2010 Resolved
Remove long section of hose installed in bilge suction line in engine room, replace with metal pipe.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 November 2010
Resolved 15 October 2010
Resolution: New section of pipe installed. All sat.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 28 September 2010 Resolved
Make additions to Drug and Alcohol Testing program to include alcohol testing requirement, provide scientific method for random employee testing. Employees must sign copy of drug testing program, program administrator must be identified in writing. Drug and Alcohol Testing program must be in compliance with all applicable regulations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2010
Resolved 15 October 2010
Resolution: All changes and additions to drug and alcohol program completed. All sat.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 28 September 2010 Resolved
Alcohol testing equipment not available. Provide approved alcohol testing equipment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2010
Resolution: New alcohol breathalyzer provided. All sat.
Navigation › Piloting/Steering › US Coast Pilot
Issued 15 August 2006 Resolved
Provide U.S. Coast Pilot Pub and light list.
Action required: 705 - Other - as specified
Due 16 September 2006
Resolved 21 August 2006
Navigation › Piloting/Steering › US Coast Pilot
Issued 1 November 2005 Resolved
Provide current navigational charts and publications IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 2 November 2005
Engineering › Bilge Water Management System › Piping
Issued 16 May 2005 Resolved
Make repairs to weld in way of bilge piping in #2 compartment.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 1 June 2005
Engineering › Bilge Water Management System › Strainer
Issued 16 May 2005 Resolved
Install strainers on all bilge pick-ups.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 1 June 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 May 2005 Resolved
Permanently cap all obsolete thru-hull fittings.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 1 June 2005
Navigation › Collision/Grounding Avoidance
Issued 1 October 2003 Resolved
Renew cloudy navigation light lenses for masthead and anchor light prior to operating in reduced visibility. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 21 October 2003
Resolution: Corrected. Master installed a new light and replacement bulb.
Lifesaving › Lifebuoys
Issued 1 October 2003 Resolved
Renew or repair ring buoy in accordance with subchapter Q. LEGACY COMPONENT DESC: Condition
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 21 October 2003
Resolution: Corrected
Lifesaving › Buoyant Apparatus
Issued 1 October 2003 Resolved
Repair outer covering to 6-person life float using manufacturer's approved patch kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 21 October 2003
Resolution: Corrected. Master purchased repair kit and affected adequate repairs to cracks in outer covering.
Operations/Management › Drug and Alcohol Testing
Issued 1 October 2003 Resolved
Provide proof that the Marine Employer's drug testing program complies with the annual training and employee assistance program. LEGACY COMPONENT DESC: EAP Training Requirements
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 21 October 2003
Resolution: Corrected
Construction/Loadline › Hull
Issued 8 May 2003 Resolved
Submit a repair proposal to repair pitting localized under the head discharge, port side. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2003
Resolved 15 May 2003
Construction/Loadline › Penetrations
Issued 8 May 2003 Resolved
Vee and re-weld through-hull fitting for generator exhaust where weld is fractured. LEGACY COMPONENT DESC: Weld
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 May 2003
Resolved 16 May 2003
Construction/Loadline › Structures
Issued 8 May 2003 Resolved
Re-weld inboard starboard engine mount in way of fracture. LEGACY COMPONENT DESC: Engine mounts
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 May 2003
Resolved 16 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 8 May 2003 Resolved
Install mesh, netting or additional course rails between top rail and bulwark so that no space is greater than 4 inches. LEGACY COMPONENT DESC: Deck Rail
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 September 2003
Resolved 1 October 2003
Resolution: Corrected. Owner installed 1/4 inch aluminum plate between rails so no space is greater than 4 inches.
Construction/Loadline › Hull
Issued 8 May 2003 Resolved
Crop and renew a 45 inch by 25 inch area of pitted bottom plate located in No. 3 compartment, just forward of the engine room bulkhead and aft of the fuel tank, starboard of the keel and extending 3 frame bays.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 19 May 2003
Communications › Radio Communications
Issued 17 September 2002 Resolved
Renew battery in EPIRB. Vessel is limited to not more than 3 miles from shore until completed. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 24 October 2002
Resolution: Corrected.
Lifesaving
Issued 20 August 2001 Resolved
Renew retro-reflective tape on lifefloats & ringbuoy.
Condition: Unknown
Due 4 September 2001
Resolved 31 August 2001
Lifesaving
Issued 20 August 2001 Resolved
Renew hydrostatic release on EPIRB and properly mount EPIRB and register with NOAA.
Condition: Unknown
Due 4 September 2001
Resolved 31 August 2001
Lifesaving
Issued 11 September 2000 Resolved
Replace the hydrostatic release on the EPIRB._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Construction/Loadline
Issued 11 September 2000 Resolved
Repair the high-level bilge alarm in the steering compartment._x001C_ _x001C_ This item to be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Engineering
Issued 11 September 2000 Resolved
Replace the clamps on the starboard M/E shaft stuffing box._x001C_ _x001C_ This item to be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Documentation
Issued 22 September 1999 Resolved
Provide a random drug testing program as required._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 September 1999
Resolved 22 September 1999
Construction/Loadline
Issued 22 September 1999 Resolved
Provide high level bilge alarms as required._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 September 1999
Resolved 22 September 1999
Lifesaving
Issued 27 August 1997 Resolved
Properly affix retro-reflective tape and supply new line (poly) to the ringbuoy._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Lifesaving
Issued 27 August 1997 Resolved
Provide a ladder to retrieve a person from the water._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Navigation
Issued 27 August 1997 Resolved
Replace worn bolts and parts on the steering system._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Engineering
Issued 27 August 1997 Resolved
Properly support the cooling line on the port main engine._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Documentation
Issued 22 September 1993 Resolved
Provide evidence of a drug testing program for your company that meets the requirements of 46 CFR part 16.
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Documentation
Issued 26 May 1988 Resolved
PROVIDE VALID FCC STATION LICENSE.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Engineering
Issued 26 May 1988 Resolved
DEMONSTRATE PROPER OPERATION OF STARBOARD MAIN ENGINE.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Fire Fighting
Issued 26 May 1988 Resolved
HAVE 1 B-I AND 3 B-II FIRE EXTINGUISHERS SERVICED BY QUALIFIED FACILITY.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Engineering
Issued 10 May 1988 Resolved
PROVIDE DOCUMENTATION FROM SERIVCING FACILITY THAT BOTH PROPELLERS WERE RE-CONDITIONED.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Engineering
Issued 10 May 1988 Resolved
RE-NEW PORT CUTLESS BEARING.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.