Records from 2016 to 2025. Most recent: inspection, 15 September 2025.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 September 2025
Resolved
EMERGENCY PROCEDURES need to be posted on vessel for crew and passengers to be able to view.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2025
Resolved 22 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 September 2025
Resolved
Renew retro tape on the 10 person life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2025
Resolved 22 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2024
Resolved
Have fittings of brass or other suitable corrsion-resistant material that comply with NFPA 1963. Replace nozzle for the fire hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2024
Resolved 14 October 2024
Resolution: Vessel has purchased a new fire nozzle.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 October 2021
Resolved
Missing crew training log. Must provide proof of crew training for each new hire and for every 3 months.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 3 November 2021
Resolution: Received pictures showing crew training documented and signed by each crew member
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 4 October 2021
Resolved
Log for abandon ship, MOB and Fire drills are not being logged properly. Must make new log and enter info as required in 46 CFR 185.20 & 185.524
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2021
Resolved 3 November 2021
Resolution: Received pictures of drill logs properly filled out.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 4 October 2021
Resolved
[name withheld] was missing his FCC operators permit. Must provide proof of FCC operators permit for any Captain operating a vessel with more than 6 passengers.
47 CFR 80.159(e)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2021
Resolved 4 October 2021
Resolution: Sent picture of his FCC operators permit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 October 2020
Resolved
Update Coast Pilot and update charts.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 19 October 2020
Resolution: Printed out all new Coast Pilot and Light list. Bought new correct Nav Chart.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 October 2020
Resolved
Clean or replace stbd nav light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2020
Resolved 19 October 2020
Resolution: Cleaned STBD side Nav light, Took picture at night time, all SAT
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 October 2020
Resolved
Bottom life float needs new reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 19 October 2020
Resolution: Replace retro on life float
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 October 2020
Resolved
Replace 01 adult life jacket. Passenger count is reduced by 1 until replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 19 October 2020
Resolution: Bought new life jacket and labeled with vessels name, showed receipt too.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 October 2020
Resolved
replaced. 180.71
Log MOB and Fire Drills as required.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 19 October 2020
Resolution: Showed new logs for drill and training to show all info required
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 October 2020
Resolved
Log EPIRB test monthly.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 19 October 2020
Resolution: Showed new log for monthly EPRIB test.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 23 September 2020
Resolved
Found pitting more than the 25 percent wastage allowed on port side hull about 1/3 of the way back around the sewage discharge pipe. Cut out and replace approx 12 inch section.
46 CFR 177.310
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2020
Resolved 28 September 2020
Resolution: cropped and renewed hull plate and 6 inches of pipe. Tested welds with 2800 psi pressure washer, All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 September 2020
Resolved
Replace port shaft strut cutless bearing and the STBD rudder cutless bearing.
46 CFR 176.610
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2020
Resolved 28 September 2020
Resolution: replaced with new bearings
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 September 2020
Resolved
Deck penatrations for anchor wiring needs to be resealed.
46 CFR 179.360
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2020
Resolved 28 September 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 September 2020
Resolved
Bulkhead penatrations need cleaned out and re sealed throught vessel
46 CFR 179.360
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2020
Resolved 28 September 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 23 September 2020
Resolved
STBD MDE STBD FWD motor mount has some pitting more that 25 percent. Gouge out and re weld pitts.
46 CFR 176.610
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2020
Resolved 28 September 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019
Resolved
All wires (conductors) shall be Marine grade or UL boat cable and of the stranded type, multiple wire runs were found to be solid copper cable (house wire). Remove and replace solid copper wires with Marine grade cables.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: All non boat/UL cables/wires removed and or replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 September 2019
Resolved
Make battery box lining available for re-inspection, boxes are corroded and holed at bottom.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Both battery boxes and lead lining replaced/repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019
Resolved
Provide insulated pressure type connectors at wire slices or splices shall be mechanically secure and made inside junction box and taped. (VHF radio, multiple connections behind operating station, and any other connections throughout vessel)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Proper connections utilized.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 September 2019
Resolved
Provide gaskets on main deck cabin doors to make them watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Gaskets added to both Aft and Portside doors.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 24 September 2019
Resolved
Provide positive shutoff valve on generator exhaust to prevent the back flow of water or permanently cap overboard penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Exhaust outlet properly plugged to the satisfaction of attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019
Resolved
Provide metal wire supports spaced not more than 24inches for all electrical wire runs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Vessels electrical system complies.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 September 2019
Resolved
Reinstall and ensure weak-link in life float is properly mounted so that painter-line is not obstructed and so that the full point load pull is directly on the weak link.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Weak link reconfigured to provide non-obstructed release.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 September 2019
Resolved
Fit each life float with a pair of paddles.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Paddles attached to each LF.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 September 2019
Resolved
Repair/replace fixed bilge metallic piping in forward compartment and lazarette compartment. Bilge piping is a vital system and required to be metallic. Flexible hoses found attached to bilge piping.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: All piping in Forward and Lazarette compartments were replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019
Resolved
Provide over current protection for windlass winch, over-current protection shall be rated or set at no more than 125 percent of the motor full-load current rating.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: 50amp inline thermal BLUESEAS breaker added within 24inches of battery terminal on the ungrounded circuit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 September 2019
Resolved
Replace flexible exhaust hose on secondary exhaust on Port Engine, hose found damaged at overboard penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Exhaust piping replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 September 2019
Resolved
Replace/repair electrical conduit under port main engine. Conduit found chaffed and exposed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Electrical conduit replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 September 2019
Resolved
STBD Power switch wire in way of main engine found with sharp bend and exposed wires. Repair/relocate switch to reduce bend in cable and repair wire insulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Switch mounting location relocated to prevent sharp bend, wire insulation repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019
Resolved
High water bilge alarms appeared to be wired with non Marine grade/boat cable, provide documentation that current wire is Marine Grade or replace wire using Boat cable or UL Marine cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Wire replaced with UL boat cable.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 September 2019
Resolved
Label high level indicators at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: HW labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 September 2018
Resolved
The float free link for the life floats does not comply with the requirement to be of sufficient breaking strenght for the combined capacity of all three floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 16 October 2018
Resolution: Float free link replaced with appropriate size.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 September 2018
Resolved
Emergency broadcast placard does not comply with 184.506
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 16 October 2018
Resolution: Emergency Broadcast placard replaced with appropriate verbiage.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 September 2018
Resolved
Vessel's vhf radio does not display lat and long
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 16 October 2018
Resolution: VHF radio repaired to display Lat and Long
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 25 September 2018
Resolved
Vessel must demonstrate that it can safely recover an incapacitated person. Plans must be submitted to provide arrangements and a drill must be conducted to show adequacy in the presence of a marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 16 October 2018
Resolution: Vessel made appropriate changes to procedures and equipment used to recover an unconscious person from the water.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 20 October 2017
Resolved
All 3 lifefloats strobe lights are broken and must be renewed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 3 November 2017
Resolution: Strobes were renewed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 October 2017
Resolved
AVH02: life ring is not serviceable, renew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 3 November 2017
Resolution: New strobe and life ring were provided. all sat.
Fire Fighting › Fire Hoses › Connections
Issued 20 October 2017
Resolved
AVH03: Fire hose is missing a nozzle. provide a non corrosive adjustable nozzle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 3 November 2017
Resolution: New fire nozzle was provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 October 2017
Resolved
AVH04: All charts, light list and Coast Pilot must be renewed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 3 November 2017
Resolution: New navigationn publications were provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 October 2017
Resolved
AVH05: First aid kit is missing contents. Provide contents per 46CFR160.041-4.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 3 November 2017
Resolution: New CG approved first aid kit was provided.
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 October 2017
Resolved
AVH06: Re-worked drill log and survival gear maintenance, per conversation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 3 November 2017
Resolution: Logs were changed to add survival gear and will be tracked monthly.