INVINCIBLE

Built
1987
Last inspected
1 November 2022
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 November 2022
…with no type recorded1
…past their stated due date4
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8833879
276546
Flag
UNITED STATES
Maury page id
psix-276546

Documentation record

Registered dimensions (L × B × D)199.7 ft × 43.0 ft × 20.0 ft
Registered tonnagegross 1,914 / net 574
ITC dimensions (L × B × D)Not recorded
ITC tonnagegross 1,914 / net 574
BuilderTACOMA BOAT · TACOMA, WA, UNITED STATES · built 1987
Hull materialSteel
PropulsionDiesel Electric
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itPublic Vessel, Unclassified
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1914 - Convention (Subpart B), Gross Ton
574 - Convention (Subpart B), Net Ton
786 - Dead Weight, Ton
2297 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 33 inspections, each with its date, unit and type; 30 deficiencies with the resolution recorded against each, 4 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 33

1 November 2022 Drydock Exam · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7587425
9 March 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7408524
24 February 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7401137
25 October 2021 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7339393
23 September 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7319414
20 August 2021 COI Inspection
Physical examination · Activities Europe · Activity 7291967
23 June 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7233452
24 May 2021 Administrative Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 7205009
18 February 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7142393
19 January 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7126486
8 December 2020 Administrative Inspection · Annual Inspection
Physical examination · Activities Europe · Activity 7108077
22 January 2020 Administrative Inspection
Administrative · Activities Europe · Activity 6893640
9 December 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6869818
18 October 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6837232
19 September 2019 Annual Inspection
Physical examination · Activities Europe · Activity 6804313
18 July 2019 Drydock Exam · Internal Structural Exam
Physical examination · Activities Europe · Activity 6753842
10 June 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6709280
15 January 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6610365
21 August 2018 Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6518375
29 July 2018 Drydock Exam · Examination of Repairs · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6494804
11 July 2018 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6475185
28 March 2018 Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6380951
24 February 2018 Deficiency Check
Physical examination · Activities Europe · Activity 6360816
21 February 2018 Administrative Inspection · Damage Survey
Physical examination · Activities Europe · Activity 6358634
29 January 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6346741
23 August 2017 Annual Inspection · Administrative Inspection
Physical examination · Activities Europe · Activity 6249180
28 June 2017 Internal Structural Exam · Drydock Exam
Physical examination · Activities Europe · Activity 6189314
13 March 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6103726
7 March 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6100133
7 March 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6302506
12 February 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6087122
29 August 2016 COI Inspection
Physical examination · Activities Europe · Activity 5987003
18 April 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5856690

Deficiency record · 30

07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 9 March 2022 No resolution recorded
Discrepancies possibly found with current fire plan for BLKH 67 STBD SIDE in between Fan Room & Workshop as A60. Also fire plan needs updated after removal of equipment. Submit new Fire Control plan to the USCG Marine Safety Center for review & approval.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2022 — due date passed with no resolution recorded
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 9 March 2022 No resolution recorded
Vessel removed large radar domes & multiple other pieces of equipment. ABS issued vessel's current Stability Letter. Provide information for any changes in vessel's lightship characteristics as per Marine Safety Center Note, MTN 04-95, CH-2 & conduct new stability test to the satisfaction of class or Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2022 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 March 2022 No resolution recorded
Complete load line survey & all associated steel repair in accordance with classification society's requirements.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2022 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 March 2022 No resolution recorded
Due to the installed bilge piping configuration, conduct testing of all bilge pumps.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2022 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 September 2021 Resolved
Where pipes, scuppers, electric cables, etc., are carried through watertight sub division bulkheads, arrangements shall be made to ensure the integrity of the watertightness of the bulkheads. ECR aft watertight bulkhead, next to watertight door has a cable pass that is not watertight. Make watertight bulkhead watertight. SOLAS 74 II-1/13(b)(I)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 September 2021
Resolved 8 September 2021
Resolution: Bulkhead was sealed and air tested to the satisfaction of Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. MI identified multiple small water leaks from the overhead insulation securing pins due to condensation from the above air conditioned space in the aft steering passageway. Particularly a few areas were located directly above electrical equipment in the space. Vsl will conduct rounds of the space while underway between the hours of 2100-0600 while the E/R is unmanned. SOLAS 14 I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 October 2021
Resolved 25 October 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 August 2021 Resolved
Wiring shall be supported in such a manner as to avoid chafing or other injury. The steering compartment has 2 exposed wires on the aft starboard overhead. Make wires so they cannot cause injury. 74 SOLAS 74 II-1/27(a)(1)(v)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 7 September 2021
Resolved 7 September 2021
Resolution: Wires were capped and unable to cause chafing or injury.
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 20 August 2021 Resolved
Test procedure documents must be in a step-by-step or checkoff list format. Each test instruction must specify equipment status, apparatus necessary to perform the tests, safety precautions, safety control and alarm setpoints, the procedure to be followed, and the expected test result. The setpoints were not being logged in accordance with approved automation procedures. Log set points in accorance with approved procedures. 46 CFR 61.40-10(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 September 2021
Resolved 8 September 2021
Resolution: Worked with CHENG to ensure all PSTP's will be logged in accorance with approved procedures.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 October 2019 Resolved
Vessel shall be equipped with 2 independently driven fire pumps. Fire pump #2 has failed due to a frozen impeller.
Action required: 15 - Rectify deficiencies by next port
Resolved 13 November 2019
Resolution: Fire pump repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 September 2019 Resolved
At least two lifebuoys on the vessel must be fitted with a self-activating smoke signal approved under approval series 160.157. The smoke signals on the bridge wing lifebuoys are not USCG approved. UPDATE: Approved signals installed, but expire on 30 November 2019. Vessel ordered new set, to be installed by 31 December.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 November 2019
Resolved 16 December 2019
Resolution: Vessel installed approved smoke floats.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 19 September 2019 Resolved
Means shall be provided to close off all vents and ventilators. Vent 1-77-1 is missing its closure.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 November 2019
Resolved 6 November 2019
Resolution: Added closure device
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 21 February 2018 Resolved
Emergency Diesel Generator fuel injection pump is leaking fuel. Repair fuel leak to the satisfaction of a USCG Inspector prior to departing Mina Salman.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2018
Resolved 1 March 2018
Resolution: Verified repairs.
Engineering › Lubricating Oil Service System › Cooler
Issued 21 February 2018 Resolved
Stbd propulsion motor's lube oil system is contaminated with sea water. Determine root cause and effect repairs to the satisfaction of a USCG Inspector prior to departing Mina Salman.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2018
Resolved 14 March 2018
Resolution: Oil coolers on both shafts were rebuilt and hydrostatically tested to 150 psi. ABS surveyor witnessed operational testing. Very light corrosion on bearings buffed off; all sat.
Lifesaving › Launching Appliances › Davit
Issued 29 January 2018 Resolved
Davit hydraulic unit failed to achieve the 200 bar pressure instead produced only 20 bars.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2018
Construction/Loadline › Structures › Superstructure
Issued 19 September 2017 Resolved
Repair/renew wasted steel in middle edge section behind the radar doom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 9 March 2018
Resolution: Navy has concerns with welding around radar. Vessel has until next DD to fix gusset, radar dome has more than enough support. Special note added.
Electrical › Electrical Distribution System (service) › Cable
Issued 19 September 2017 Resolved
Make permanent repairs to search light wiring on the port and starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 1 March 2018
Resolution: Repairs verified.
Deck/Cargo › Mooring/Anchoring › Clutch
Issued 19 September 2017 Resolved
Repair inoperable anchor windlass clutch control.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 1 March 2018
Resolution: Repairs completed.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 19 September 2017 Resolved
Repair/service port and stbd aft mooring winch motors. Provide report.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 1 March 2018
Resolution: Aft winch motors tested sat.
Electrical › Electrical Distribution System (service) › Cable
Issued 19 September 2017 Resolved
Thoroughly inspect/replace corroded or deteriorating port and stbd side aft mooring windlass cables exposed to the weather deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 1 March 2018
Resolution: Replaced corroded wiring.
Fire Fighting › Structural - A Class Divisions › Corridors
Issued 19 September 2017 Resolved
Provided proper A class fire boundary in the RIC Vestibule access way (tube) (bulkhead 1-72) IWO of bulkhead top. Use approved penetration to seal the bulkhead opening. Submit installation plan by 17 October.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 31 January 2018
Resolution: Rcvd service report attesting to complete repair.
Lifesaving › Immersion Suits › Not on Board
Issued 19 September 2017 Resolved
One crew member was not provided with a properly size immersion suit. Provide properly sized immersion suit prior to operating outside of area between 32N/32S longitude.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 18 October 2017
Resolution: Receiced notification that the crew member was provided with a properly sized immersion suit.
Communications › Radio Communications › Satellite Communications Capability
Issued 12 February 2017 Resolved
The GMDSS MF/HF receiver is not operating. Prove proper operation of the GMDSS suite no later than 12 Mar 2017.
Action required: 705 - Other - as specified
Due 12 March 2017
Resolved 11 March 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 September 2016 Resolved
Provide certificate of servicing for all fixed and portable fire extinguishing equipment to include the pull station for the gaylord hood system in the galley.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2016
Resolved 28 September 2016
Resolution: Received report of successful servicing of required fire extinguishing items.
Lifesaving › Inflatable Liferafts › Float Free
Issued 14 September 2016 Resolved
Provide pictures of proper installation of the inflatable liferafts
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2016
Resolved 28 September 2016
Resolution: Received required pictures showing the proper installation
Electrical › Electric Generation Source (service) › Generator
Issued 14 September 2016 Resolved
Provide CAT tech rep report of proper operation of all shut downs and alarms on # 1 SSDG.
Action required: 705 - Other - as specified
Due 28 September 2016
Resolved 22 September 2016
Resolution: Recieved report from ABS surveyor that the alarms and shut downs are fully operational.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 September 2016 Resolved
Demonstrate proper operation of the OWS. AMintain all oily waste onboard the vessel or discharge to a proper shore side facility.
Action required: 705 - Other - as specified
Due 28 September 2016
Resolved 25 September 2016
Resolution: Recieved report of proper operation of the OWS
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 14 September 2016 Resolved
Demonstrate proper operation of the forward mooring capstan
Action required: 705 - Other - as specified
Due 28 September 2016
Resolved 25 September 2016
Resolution: Received report of proper operation of the mooring capstan
Engineering › Bilge Water Management System › Pump
Issued 14 September 2016 Resolved
Demonstrate proper operation of the # 3 bilge pump
Action required: 705 - Other - as specified
Due 28 September 2016
Resolved 25 September 2016
Resolution: Received report of proper operation of the # 3 bilge pump
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 14 September 2016 Resolved
Remove all excess strorage from the hospital space
Action required: 705 - Other - as specified
Due 28 September 2016
Resolved 22 September 2016
Resolution: Received pictures showingt the removal of storage in the hospital space.
Navigation › Piloting/Steering › Gyro Compass
Issued 18 April 2016 Resolved
The vessel's gyro compass is not operating properly and is currently not a reliable means of navigation. Repairs shall be affected to the gyro compass prior to the departure of the next port of call, but no later than 26 Apr 2016. After this date, movement of the vessel is prohibited unless a request for a National Defense waiver has been submitted and approved.
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 24 April 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.