MAURY USCG vessel records Sign in
← All vessels

TALISMAN

TALISMAN is a 1961 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 1987, most recently in October 2002, along with 33 deficiencies.

Records from 1987 to 2002. Most recent: inspection, 3 October 2002.

Built
1961
Last inspected
3 October 2002
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

276614
Flag
UNITED STATES
—
Maury page id
psix-276614

Inspections, by type

Years with a record 16 calendar years (1987–2002)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.0 ft × 16.0 ft × 3.0 ft
Registered tonnagegross 24 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · DUBUQUE IA, UNITED STATES · built 1961
Hull materialSteel
PropulsionCombination Types
Hull shapeBox
Hull configurationMonohull
Hailing portPORT OF PETERSBURG, IL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 21 June 2000 · expires 30 June 2002
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Simplified, Net Ton
24 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 24

3 October 2002 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1683957
20 June 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1366535
22 August 2000 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1397481
3 June 1999 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1446774
14 May 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1430556
25 June 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1109583
20 June 1996 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1405929
4 June 1996 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1371475
3 July 1995 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 872158
22 June 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1456283
30 June 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1173050
26 May 1994 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1453041
25 June 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1154356
4 June 1993 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 827214
23 April 1992 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1458035
11 February 1992 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 959558
20 June 1991 Hull Examination · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 900170
5 June 1990 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1213233
26 July 1989 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1340702
9 June 1989 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1202880
27 April 1988 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1201297
1 September 1987 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1004928
15 July 1987 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1325335
10 June 1987 Hull Examination · Initial Certification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1317610

Deficiency record · 33

Engineering
Issued 20 June 2001 Resolved
Replace all rotten wooden boards, nuts and bolts on vessels paddlewheel.
Condition: Unknown
Due 3 June 2002
Resolved 3 October 2002
Resolution: Vessel was deactivated on 10/03/02. Cleared all deficiencies in MISLE files for administrative purposes. See activity #1683957 narrative for cleared deficiencies prior to reactivating COI.
Lifesaving
Issued 20 June 2001 Resolved
Prior to carrying passengers prove operation of all vessel operating systems.
Condition: Unknown
Due 3 June 2002
Resolved 3 October 2002
Resolution: Vessel was deactivated on 10/03/02. Cleared all deficiencies in MISLE files for administrative purposes. See activity #1683957 narrative for cleared deficiencies prior to reactivating COI.
Construction/Loadline
Issued 20 June 2001 Resolved
Prior to carrying passengers, conduct ultrasonic testing of hull thickness and replace to as original conditions.
Condition: Unknown
Due 3 June 2002
Resolved 3 October 2002
Resolution: Vessel was deactivated on 10/03/02. Cleared all deficiencies in MISLE files for administrative purposes. See activity #1683957 narrative for cleared deficiencies prior to reactivating COI.
Lifesaving
Issued 20 June 2001 Resolved
Prior to carrying passengers, conduct satisfactory emergency drills.
Condition: Unknown
Due 3 June 2002
Resolved 3 October 2002
Resolution: Vessel was deactivated on 10/03/02. Cleared all deficiencies in MISLE files for administrative purposes. See activity #1683957 narrative for cleared deficiencies prior to reactivating COI.
Lifesaving
Issued 20 June 2001 Resolved
Complete installation of bilge alarm system as per 46 CFR 182.115(d) and 182.530.
Condition: Unknown
Due 3 June 2002
Resolved 3 October 2002
Resolution: Vessel was deactivated on 10/03/02. Cleared all deficiencies in MISLE files for administrative purposes. See activity #1683957 narrative for cleared deficiencies prior to reactivating COI.
Accommodation/Occupational Safety
Issued 20 June 2001 Resolved
Replace all rotten wooden rails on passenger decks.
Condition: Unknown
Due 3 October 2002
Resolved 3 October 2002
Resolution: Vessel was deactivated on 10/03/02. Cleared all deficiencies in MISLE files for administrative purposes. See activity #1683957 narrative for cleared deficiencies prior to reactivating COI.
Accommodation/Occupational Safety
Issued 20 June 2001 Resolved
Replace flooring system on upper deck of passenger area.
Condition: Unknown
Due 3 October 2002
Resolved 3 October 2002
Resolution: Vessel was deactivated on 10/03/02. Cleared all deficiencies in MISLE files for administrative purposes. See activity #1683957 narrative for cleared deficiencies prior to reactivating COI.
Navigation
Issued 20 June 2001 Resolved
Replace center rudder to original condition prior to getting underway w/ passengers.
Condition: Unknown
Due 3 June 2002
Resolved 3 October 2002
Resolution: Vessel was deactivated on 10/03/02. Cleared all deficiencies in MISLE files for administrative purposes. See activity #1683957 narrative for cleared deficiencies prior to reactivating COI.
Engineering
Issued 20 June 2001 Resolved
Replace wooden bearing pads for stern paddlewheel.
Condition: Unknown
Due 3 October 2002
Resolved 3 October 2002
Resolution: Vessel was deactivated on 10/03/02. Cleared all deficiencies in MISLE files for administrative purposes. See activity #1683957 narrative for cleared deficiencies prior to reactivating COI.
Lifesaving
Issued 22 August 2000 Resolved
PRIOR TO CARRYING PASSENGERS CONDUCT SATISFACTORY EMERGENCY DRILLS.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Lifesaving
Issued 22 August 2000 Resolved
COMPLETE INSTALLATION OF BILGE ALARM SYSTEM AS PER 46 CFR 182.115(d) AND 182.530.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Lifesaving
Issued 22 August 2000 Resolved
PRIOR TO CARRYING PASSENGERS PROVE PROPER OPERATION OF ALL VESSEL OPERATINGSYSTEMS.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Construction/Loadline
Issued 22 August 2000 Resolved
PRIOR TO CARRYING PASSENGERS MAKE REPAIRS TO VESSEL HULL AND DECK PLATING AS NECESSARY.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Lifesaving
Issued 3 June 1999 Resolved
PRIOR TO CARRYING PASSENGERS CONDUCT SATISFACTORY EMERGENCY DRILLS.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Lifesaving
Issued 3 June 1999 Resolved
COMPLETE INSTALLATION OF BILGE ALARM SYSTEM AS PER 46 CFR 182.115(d) AND 182.530.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Lifesaving
Issued 3 June 1999 Resolved
PRIOR TO CARRYING PASSENGERS PROVE PROPER OPERATION OF ALL VESSEL SYSTEMS.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Documentation
Issued 3 June 1999 Resolved
PROVIDE PROOF OF VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Electrical
Issued 14 May 1998 Resolved
MARK LOCATIONS ON ELECTRICAL BREAKER, THAT IS LOCATED ON MAIN DECK, BY POPCORN MACHINE
Condition: Unknown
Due 14 May 1998
Resolved 15 May 1998
Lifesaving
Issued 25 June 1997 Resolved
PRIOR TO CARRIAGE OF PASSENGERS, CONDUCT EXAMINATION FOR RE-INSPECTION AS REQUIED BY LOCAL CG MARINE INSPECTOR.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Navigation
Issued 22 June 1995 Resolved
PROVIDE KEYED PIN (OR EQUIVALENT) FOR CENTER RUDDER HINGE.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Fire Fighting
Issued 22 June 1995 Resolved
PRIOR TO CARRYING PASSENGER, PROVIDE HOSE FOR PORTABLE FIRE/BILGE PUMP.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Lifesaving
Issued 22 June 1995 Resolved
REPLACE BROKEN WINDOWS IN PILOTHOUSE.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Engineering
Issued 26 May 1994 Resolved
REPLACE FLAME SCREEN FOR FUEL TANK VENT
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Lifesaving
Issued 26 May 1994 Resolved
REPLACE LINE FOR RING BUOY.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Lifesaving
Issued 4 June 1993 Resolved
PROVIDE (2) ADULT PFDS. TOTAL PERSONS ALLOWED ONBOARD REDUCED TO (98) UNTIL COMPLIANCE.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Lifesaving
Issued 5 June 1990 Resolved
PLACE ONBOARD 4 ADULT TYPE I PFD'S TO BRING TOTAL TO 100 AS PER COI.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Accommodation/Occupational Safety
Issued 9 June 1989 Resolved
PROVIDE THE MINIMUM REQUIRED VENTILATION IN THE FUEL TANK COMPARTMENT AND THE AFT TWO COMPARTMENTS.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Electrical
Issued 9 June 1989 Resolved
INSTALL BATTERY DISCONNECT SWITCH.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Documentation
Issued 10 June 1987 Resolved
COMPLETE WORKLIST ISSUED ON 10 JUN 1986 TO THE SATISFACTION OF THE COGNIZANT [name withheld] OF VESSEL BUT NOT LATER THAT 10 JUL 87.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Lifesaving
Issued 10 June 1987 Resolved
POST EMERGENCY CHECKLIST PER 46CFR182.25-5
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Accommodation/Occupational Safety
Issued 10 June 1987 Resolved
DEMONSTRATE USE OF PUBLIC ADDRESS SYSTEM.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Fire Fighting
Issued 10 June 1987 Resolved
REPLACE PRESENT FIRE HOSE WITH U.L. APPROVED HOSE.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Deck/Cargo
Issued 10 June 1987 Resolved
REPLACE ANCHOR LINE.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.