Records from 2012 to 2026. Most recent: inspection, 11 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)64.5 ft × 23.5 ft × 6.4 ft
Registered tonnagegross 47 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKVICHAK MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portLONG BEACH, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Simplified, Net Ton
47 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
11 March 2026
Vessel Attendance · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8235599
12 June 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8087645
19 February 2025
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8004986
7 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7868409
8 January 2024
Damage Survey · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7846540
8 May 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7684005
6 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7626994
8 February 2023
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7606429
15 February 2022
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7396983
27 April 2021
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7175752
3 February 2021
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7135219
15 July 2020
Internal Structural Exam · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6928242
20 May 2019
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6641380
19 February 2019
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6624832
6 June 2018
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6436318
26 April 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6379696
1 September 2017
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6257214
31 August 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6259901
16 March 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6104630
19 January 2017
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6069644
16 December 2016
Plan Review "T" Boat · Deficiency Check · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6084048
27 April 2016
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5828623
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 May 2024
Resolved
All equipment including switches, fuses, lampholders, etc., must be suitable for the voltage and current utilized. Electrical equipment was found plugged into a series of daisy-chained extension cords in vessel's electronics room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2024
Resolved 17 May 2024
Resolution: Removed all extension cords and plugged equipment into approved receptacles and outlets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2024
Resolved
A vessel with an electrical system operating at more than 50 volts, which is provided with a means to connect to shore power, a shore power connection box or receptacle must be permanently installed at a convenient location. Shore power receptacle was found damaged due to an incident where the shore power plug was not disconnected prior to vessel leaving the dock. Repair or replace vessels shore power receptacle, all electrical installations shall be conducted in accordance with requirements listed in 46 CFR 183 or those incorporated by reference.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2024
Resolved 31 January 2024
Resolution: Proper repairs made to shore tie connection.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 6 April 2023
Resolved
Each vessel must be equipped with a public address system. The external speakers for the vessel's public address system were found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2023
Resolved 18 April 2023
Resolution: Operators installed new speakers and conducted a satisfactory PA system test.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 April 2023
Resolved
Each vessel must be marked as required by 46 CFR 67,
subpart I. The name of the vessel must be marked on
some clearly visible exterior part of the bow and stern
of the vessel. The vessel name marked on the hull does
not match that of the name listed on official
documentation.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2023
Resolved 18 April 2023
Resolution: Operators confirmed that vessel will continue to use AQUALINK name and have marked all areas of hull as such.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 October 2020
Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free. Vessel was discovered with straps over life floats, preventing them from floating free in the event of an emergency. Vessel must provide an appropriate float free arrangement for life floats before carrying passengers.
46 CFR 180.130(a)(2); 701c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2020
Resolved 7 October 2020
Resolution: Vessel proved proper float-free arrangement of the life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 October 2020
Resolved
The lifeline and pendants must be as furnished by the manufacturer with the approved life float or buoyant apparatus. Replacement lifelines and pendants must meet the requirements in Subpart 160.010 of this chapter. Approx 50% of the lifelines on both life floats were deteriorated enough that they had come apart. Pendants on both life floats must be replaced/serviced by an authorized servicing facility.
46 CFR 180.175(f)(1); 50c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2020
Resolved 7 October 2020
Resolution: Vessel replaced all lifelines and pendants on both life floats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 May 2019
Resolved
Shipps crew could not immediately draw suction utilizing fixed bilge pumping system
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2019
Resolved 20 May 2019
Resolution: proper operation of bilge suction was finally properly demonstrated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 May 2019
Resolved
02 life buoys had unservicable life line. Replace life line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2019
Resolved 21 May 2019
Resolution: Verified life lines were replaced
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 26 April 2018
Resolved
Improper installation of Bratberg MCT compression block in watertight bulkheads
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2018
Resolution: Corrected on the spot with fireblock. Correction is not as per MCT design but meets criteria for a T-boat.
Lifesaving › Lifebuoys › Serviceable
Issued 26 April 2018
Resolved
Line needs replacement on port stern life ring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2018
Resolution: Replaced on the spot.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, Positive Displacement
Issued 1 September 2017
Resolved
Prove proper operation of the STBD MDE to the satisfaction of the attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2017
Resolution: Operator installed new raw water pump.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 1 September 2017
Resolved
Service/restore STBD engine room CO2 system to the satisfaction of the attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2017
Resolution: CO2 system was serviced and 75 LBS CO2 replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 1 September 2017
Resolved
Replace discharged B-II portable fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2017
Resolution: Dry-chem portable extinguisher was replaced with new.
Engineering › Diesel Engine (propulsion-direct drive) › Waste Heat Recovery
Issued 1 September 2017
Resolved
Conduct sea-trial to the satisfaction of the attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2017
Resolution: Conducted satisfactory sea-trial.
Lifesaving › Lifefloat › Retroreflective Material
Issued 16 March 2017
Resolved
Renew life floats retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 16 March 2017
Resolution: Vessel replaced all retro reflective tape
Communications › Radio Communications › VHF Radiotelephone
Issued 16 March 2017
Resolved
Provide a DSC capable VHF radio.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 16 March 2017
Resolution: Vessel purchased and installed new DSC capable VHF radio
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 January 2017
Resolved
Replace missing bulkhead cable penetrations (cable transit blocks) identified throughout vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 February 2017
Resolved 1 February 2017
Construction/Loadline › Structures › Superstructure
Issued 19 January 2017
Resolved
Replace seals on forward facing windows.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 February 2017
Resolved 1 February 2017
Engineering › Bilge Water Management System › Pump
Issued 27 April 2016
Resolved
Provide portable hand bilge pump that is capable of pumping all bilge spaces as per 46 CFR 182.520(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 20 May 2016
Resolution: Provided operable portable hand bilge pump.
Fire Fighting › Fire Main › Condition
Issued 27 April 2016
Resolved
Make permanent repairs to 02 holes on firemain in port and starboard engine room as per 46 CFR 181.310(b) and 46 CFR 182.700
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 20 May 2016
Resolution: Repaired 02 holes.
Lifesaving › Rigid Liferafts › Weak Link
Issued 27 April 2016
Resolved
Provide new weak link with identification tag for port life float as per 46 CFR 180.137(b)(2)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 20 May 2016
Resolution: Provided new weak link.
Lifesaving › Lifefloat › Markings
Issued 27 April 2016
Resolved
Properly label all life floats with number of persons capacity as per 46 CFR 185.604(e)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 20 May 2016
Resolution: Labeled all lifefloats with persons capacity.