QUEEN MARY

QUEEN MARY is a 1987 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1987, most recently in April 2026, along with 40 deficiencies.

Records from 1987 to 2026. Most recent: inspection, 29 April 2026.

Built
1987
Last inspected
29 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ7526
277048
Flag
UNITED STATES
368007590
Maury page id
psix-277048

Inspections, by type

…with no type recorded2
Years with a record 36 calendar years (1987–2026)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.0 ft × 22.0 ft × 7.0 ft
Registered tonnagegross 83 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT, INC. · PATTERSON LA · built 1987
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPOINT PLEASANT BEACH, NJ
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 8 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Dead Weight, Gross Ton
32 - Displacement, Gross Ton
83 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ7526MMSI 368007590 · active · compulsorily equipped · granted 23 September 2017, expires 23 September 2027
WTQ7882MMSI 367343610 · expired · compulsorily equipped · granted 19 March 2008, cancelled 23 June 2018 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 64

29 April 2026 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8325159
12 March 2025 Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8092036
29 April 2024 Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7901734
1 May 2023 Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7678546
3 April 2023 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7662039
22 April 2022 Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7435966
10 February 2022 In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7393952
5 November 2021 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7345844
22 April 2021 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7398464
30 December 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7117706
5 May 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6948025
1 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6673688
6 December 2018 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6595801
7 May 2018 Administrative Inspection · Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6407871
21 March 2018 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6372900
22 September 2017 DAPI Audit · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6274835
13 April 2017 COI Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6123449
6 June 2016 Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5899313
11 December 2015 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5779628
15 May 2014 Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 4859062
15 December 2009 Hull Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3650817
3 June 2008 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3226303
22 April 2008 Hull Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3189909
9 April 2007 COI Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2906441
15 June 2006 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2679641
15 March 2006 Hull Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2603606
26 May 2005 Annual Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2386198
6 May 2004 Annual Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2061128
2 April 2004 Administrative Inspection
Administrative · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2036274
8 March 2004 Hull Examination · Internal Structural Exam
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2020231
7 May 2003 Re-Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1788359
11 April 2002 COI Inspection · Internal Structural Exam
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1603699
15 February 2002 Administrative Inspection
Administrative · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1486827
3 December 2001 Internal Structural Exam · Hull Examination
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1432592
8 May 2001 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1463656
23 May 2000 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1443022
26 January 2000 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1365557
19 May 1999 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1091995
23 April 1999 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1127137
12 May 1998 Re-Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1125955
21 January 1998 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 775879
18 November 1997 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1109090
29 April 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1093096
19 April 1996 Deficiency Check · COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1085720
13 February 1996 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1187522
10 January 1996 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1192222
25 April 1995 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 866767
15 April 1994 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1168092
24 March 1994 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1165867
8 April 1993 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1148279
2 April 1992 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1011934
6 March 1992 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1009388
3 April 1991 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 935193
3 April 1991 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1216710
7 March 1991 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1217809
17 April 1990 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1240201
29 March 1990 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 908806
27 November 1989 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1232160
21 September 1989 Drydock Extension
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 893435
30 March 1989 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1043391
31 March 1988 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 994615
5 March 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287347
13 May 1987 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1023465
5 March 1987 Hull Examination · Initial Certification
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017142

Deficiency record · 40

07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 April 2022 Resolved
The discharge ends of fuel tank vent pipes must be fitted with flame screens. There are holes in the sides of the vent pipe located above the flame screen. 46 CFR 182.450(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2022
Resolved 15 May 2022
Resolution: flame screen replaced on fuel vent
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2022 Resolved
Electrical equipment on a vessel must be maintained to protect passengers, crew, and other persons from electrical hazards. Identified a 1.5 amp ground from unknown source. 46 CFR 183.200(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2022
Resolved 15 May 2022
Resolution: Ground detection meter replaced with new.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 January 2021 Resolved
Nonmetallic material is permitted for use in piping systems with certain restrictions... Penetrations through watertight bulkheads must be accomplished using an acceptable metallic fitting and an acceptable metallic shutoff valve is installed adjacent to the through deck or through bulkhead fitting that is operable from above the bulkhead deck. Alternatively, two valves can be installed, one on each side of the bulkhead, that do not need to be operable from above the bulkhead deck as long as immediate access to both valves is possible. Install suitable valve arrangement for the nonmetallic sewage piping that leads from both heads and penetrates the watertight bulkhead between the engine room and lazarette compartments, or install all metallic piping for the system. - 46CFR182.40-1(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 5 November 2021
Resolution: Rec'd photo of cleared def. Photo uploaded into Docs as - QM_Cleared835Piping.pdf
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 January 2021 Resolved
Permanent 6" tall watertight coamings must be provided for weathertight doors to meet the applicable height requirements for the vessel's route. Observed openings in coamings on the port, starboard and aft weathertight doors. Provide acceptable means to make these coaming areas watertight. - 46CFR171.124(d)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2021
Resolved 22 February 2021
Resolution: Mechanical closures provided for all penetrations using compression plate and expanding seal. CG-835 cleared by photos.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 May 2019 Resolved
Provide a pressure gauge at the fire pump outlet. - 46 CFR 181.300b
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 3 May 2019
Resolution: Owner supplied a photograph of the new gauge, attached to the documents section.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 May 2019 Resolved
Make life jackets on main deck more accessible. Separate child life jackets from adult on main deck. - 46 CFR 180.78
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 30 May 2019
Resolution: An additional hatch was added to the top of the stowage area.
Construction/Loadline › Hull › Hull Plating
Issued 22 March 2018 Resolved
BS01. Crop and renew pitted plate along the keel in the second space aft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2018
Resolved 6 December 2018
Resolution: Rolled into credit dry dock activity 6595801
Construction/Loadline › Hull › Hull Plating
Issued 22 March 2018 Resolved
BS02. Crop and renew pitted port and starboard chine plates in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2018
Resolved 6 December 2018
Resolution: Rolled into credit dry dock activity 6595801
Construction/Loadline › Hull › Longitudinal Frame
Issued 22 March 2018 Resolved
BS03. Crop and renew keel longitudinal with pitting in the forward part of the lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2018
Resolved 6 December 2018
Resolution: Rolled into credit dry dock activity 6595801
Operations/Management › Drills/Instruction › Abandon Ship
Issued 22 September 2017 Resolved
Vessel was unable to conduct man overboard drill at time of inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2017
Resolution: Witnessed crwe conduct satisfactory man overboard drill.
Documentation › Certificates/Documents › FCC SSL
Issued 22 September 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2017
Resolution: Verified FCC documentation is on board the vessel.
Communications › Radio Communications › EPIRB
Issued 22 September 2017 Resolved
Provide EPIRB registration sticker prior to operating beyond 3 nm.
Action required: 705 - Other - as specified
Resolved 29 September 2017
Resolution: Sticker with updated vessel information arrived in the mail. Attached to EPIRB.
Documentation › Markings/Placards › Warning Signs
Issued 22 September 2017 Resolved
Provide emergency broadcast placard
Due 22 October 2017
Resolved 29 September 2017
Resolution: Placard placed in pilot house above operating station.
Navigation › Piloting/Steering › Marine Charts
Issued 8 June 2016 Resolved
Provide new charts for area.
Due 24 June 2016
Resolved 20 June 2016
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 8 June 2016 Resolved
Flex hoses deteriorated connecting gensets to exhuast piping in engine room.
Due 24 June 2016
Resolved 20 June 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 June 2006 Resolved
Provide Rescue Platform.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 29 June 2006
Resolution: Rigid Aluminum ladder provided.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 15 June 2006 Resolved
Replace plates for engine space ventilation openings.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 29 June 2006
Resolution: Covers provided.
Lifesaving › Lifefloat › Painter
Issued 15 June 2006 Resolved
Properly rig lifefloats.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 29 June 2006
Resolution: New lines provided and rigged correctly.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 May 2005 Resolved
Renew reflective tape on multiple lifejackets.
Condition: Improper/Lack of Maintenance
Due 26 May 2005
Resolved 26 May 2005
Resolution: Corrected as they were being stowed.
Engineering › Bilge Water Management System › Interface Detector
Issued 26 May 2005 Resolved
Repair FWD bilge hi level alarm.
Due 26 May 2005
Resolved 26 May 2005
Resolution: Corrected prior to departure.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 26 May 2005 Resolved
[name withheld] Passenger Count for Upper Deck.
Condition: Improper/Lack of Maintenance
Due 26 May 2005
Resolved 26 May 2005
Resolution: Corrected
Lifesaving › Buoyant Apparatus
Issued 6 May 2004 Resolved
Renew Grab Lines and pennant line on top lifefloats located starboard side. LEGACY COMPONENT DESC: Grab Lines
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2004
Resolved 12 May 2004
Resolution: Line renewed.
Lifesaving › Lifejacket/PFD (Type I)
Issued 6 May 2004 Resolved
Renew reflective material on all PFD's as needed. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2004
Resolved 12 May 2004
Resolution: Renewed as needed.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 11 April 2002 Resolved
PROVIDE CURRENT CREW LIST FOR DRUG TESTING PROGRAM
Due 25 April 2002
Resolved 11 April 2002
Resolution: DONE
Lifesaving
Issued 23 April 1999 Resolved
COMPLETE DRILLS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 23 April 1999
Resolved 23 April 1999
Lifesaving
Issued 12 May 1998 Resolved
RENEW EPIRB HYDROSTATIC RELEASE._x001C_ VESSEL RESTRICTED TO NMT 03 MILES FROM LAND UNTIL CORRECTED.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 April 1996 Resolved
STENCIL STARBOARD L/F PADDLES
Condition: Unknown
Due 26 April 1996
Resolved 1 May 1996
Lifesaving
Issued 19 April 1996 Resolved
RENEW ALL LIFESAVING EQUIPMENT BATTERIES
Condition: Unknown
Due 26 April 1996
Resolved 1 May 1996
Lifesaving
Issued 19 April 1996 Resolved
MAKE PORT L/F WATERLIGHTS ABLE TO FLOAT FREE
Condition: Unknown
Due 26 April 1996
Resolved 1 May 1996
Accommodation/Occupational Safety
Issued 19 April 1996 Resolved
LABEL UPPER DECK PASSENGER CAPACITY
Condition: Unknown
Due 26 April 1996
Resolved 1 May 1996
Construction/Loadline
Issued 25 April 1995 Resolved
REPAIR REACH ROD TO COLLISION COMPARTMENT BILGE SUCTION VALVE._x001C_ _x001C_ VALVE TO REMAIN CLOSED UNTIL CORRECTED
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Lifesaving
Issued 25 April 1995 Resolved
INSTALL NEW REFLECTIVE TAPE ON 4 ADULT PFD's_x001C_ _x001C_ VESSEL RESTRICTED TO NO MORE THAN 151 PERSON ONBOARD UNTIL CORRECTED
Condition: Unknown
Due 3 May 1995
Resolved 8 May 1995
Engineering
Issued 15 April 1994 Resolved
LABEL EMERGENCY FUEL SHUT OFF.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Lifesaving
Issued 15 April 1994 Resolved
RENEW TWO(02) RING BUOYS.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Fire Fighting
Issued 15 April 1994 Resolved
RENEW ONE(01) FIRE HOSE.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Construction/Loadline
Issued 24 March 1994 Resolved
DOUBLE CLAMP BOTH ENDS OF GEN S/W HOSES.
Condition: Unknown
Due 4 April 1994
Resolved 4 April 1994
Construction/Loadline
Issued 24 March 1994 Resolved
CAP SINK DRAIN OVERBOARD PIPING CONNECTION, PORT SIDE.
Condition: Unknown
Due 4 April 1994
Resolved 4 April 1994
Construction/Loadline
Issued 24 March 1994 Resolved
REPLACE INLET/OUTLET HOSE TO STBD BILGE PUMP.
Condition: Unknown
Due 4 April 1994
Resolved 4 April 1994
Construction/Loadline
Issued 24 March 1994 Resolved
REPAIR, REPLACE STBD BILGE OVERBOARD PIPING ELBOW.
Condition: Unknown
Due 4 April 1994
Resolved 4 April 1994
Construction/Loadline
Issued 24 March 1994 Resolved
REWELD HOLE IN SKEG 1/8".
Condition: Unknown
Due 4 April 1994
Resolved 4 April 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.