MAURY USCG vessel records
← All vessels

BOSTON BELLE

Built
1986
Last inspected
19 September 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 September 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ6666
277347
Flag
UNITED STATES
Maury page id
psix-277347

Documentation record

Registered dimensions (L × B × D)52.0 ft × 16.3 ft × 4.9 ft
Registered tonnagegross 63 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSKIPPERLINER INDUSTRIES · LA CROSSE, WI, UNITED STATES · built 1986
Hull materialSteel
PropulsionDiesel Outdrive
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBOSTON, MA
Endorsements, as the file codes themcw_un, fi, rec
DocumentationValid · issued 8 July 2025 · expires 30 June 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Simplified, Gross Ton
50 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 20 inspections, each with its date, unit and type; 43 deficiencies with the resolution recorded against each, 3 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

19 September 2025 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8235906
19 March 2025 Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8096168
5 September 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7991294
14 September 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7787826
27 June 2023 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7725249
27 June 2023 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7727068
19 January 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7620689
12 September 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7543129
16 June 2021 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7218339
12 November 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7094089
24 February 2020 Hull Examination · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6914208
25 June 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6724165
31 January 2019 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6618099
4 September 2018 Deficiency Check · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6533285
3 September 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6533640
29 June 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6459638
27 June 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6188038
1 December 2016 Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6051398
6 May 2016 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5869366
3 March 2016 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5826340

Deficiency record · 43

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 September 2025 No resolution recorded
Nonmetallic flexible hose must be in accordance with SAE J1942 and may be installed only in vital and non vital fresh and salt water systems... Fire main piping was found with nonmetallic flexible hose not built to SAE-J1942. 705: No more than 49 passengers may be carried and vessel must meet 46 CFR 181.610 for fire buckets or 46 CFR 181.10-5 for a 5GPM hand fire pump.
Condition: Invalid
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 25 September 2025 No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull... Deck plating wastage observed in the compartment below forward stairs, approx. 1" diameter, below the interface between the starboard stair stringer and deck plating.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2027
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 September 2025 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. Forepeak bilge pipe coupling aft of isolation valve in compartment below forward stairs observed leaking.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2025
Resolved 9 October 2025
Resolution: Tested forepeak bilge pipe. No leaks detected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2025 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Ring Life buoy is not marked with retroreflective material.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2025
Resolved 9 October 2025
Resolution: Retro applied to ring lifebuoy.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 September 2025 No resolution recorded
Penetrations and openings in watertight bulkheads must...have means to make them watertight. Fire main piping penetrating the aft main traverse bulkhead is not watertight. 705: No more than 49 passengers may be carried.
Condition: Improper Installation
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 September 2025 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in § 176.500(b)(1) and your Certificate of Inspection must be endorsed. Required annual inspection was missed and due no later than September 17, 2025. 46 CFR 176.502
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2025
Resolution: COI Renewal Inspection completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 March 2025 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel did not complete required drydock exam by due date. Credit hull/ISE to be completed prior to carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2025
Resolution: Vessel was issued credit hull/ise.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 September 2024 Resolved
Waste receptacle must be constructed of non-combustible materials with no openings in the side or bottom. The waste receptacles on the vessel's passenger deck were found to be made of plastic.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 19 September 2024
Resolution: Operator provided photograph of metal trash cans on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 September 2024 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Extinguisher in pilothouse was found to not be mounted securely.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 19 September 2024
Resolution: Operator provided photograph showing fire extinguisher properly mounted.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 5 September 2024 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter: The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred, unless precluded by safety concerns directly related to the incident. MI found that there were no alcohol swabs on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 23 September 2024
Resolution: Operator submitted a photograph showing alcohol test strips were on board.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 5 September 2024 Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. MI found corrosion in the overhead of the aft engine space, and a hole in the aft deck leading down to the engine space. MI also found the lower course on the STBD bow handrail to be corroded and broken. To be corrected prior to next credit hull inspection.
Action required: 705 - Other - as specified
Resolved 14 April 2025
Resolution: New insert welded in the aft bulkhead and an approved doubler installed on the deck.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2024 Resolved
All lights, recepticles and switches exposed to the weather shall be watertight. MI found 02 light fixtures and 01 outlet on the weatherdecks missing watertight covers. Old T: 46 CFR 183.05-35(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 23 September 2024
Resolution: Operator submitted a photograph showing weathertight covers on exterior electrical equipment.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2024 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. MI found an extension cord used as a permanent wire to the air compressor as well as several dead-ended wires throughout the main hold and engine compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 19 September 2024
Resolution: Operator provided photograph showing dead-end wires had been cut back and power source for air compressor has been hard-wired in.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 September 2024 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. MI found bilge piping leaking at a union. 46 CFR 182.25-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 23 September 2024
Resolution: Operator submitted photograph showing a new union had been installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 September 2023 Resolved
Each hatch exposed to the weather must be watertight. Vessel forward forecastle scuttle hatch gasket was ripped in multiple places rendering it inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2023
Resolved 26 September 2023
Resolution: O/O replaced forward forecastle scuttle hatch gasket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 September 2023 Resolved
Each vessel must carry one life buoy with floating waterlight. Vessel's waterlight was not operating. O/O to provide one properly function waterlight for ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2023
Resolved 26 September 2023
Resolution: O/O fixed life ring buoy water light to satisfaction of attending marine inspector.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 14 September 2023 Resolved
Vessels are to properly display the garbage pollution prevention placard. Vessel was missing the garbage placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2023
Resolved 26 September 2023
Resolution: O/O purchase new garbage pollution prevention placard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 September 2023 Resolved
Portable fire extinguishers mus be located so that they are clearly visible and readily accessible from the space being protected. The location and installation must be to the satisfaction of the OCMI. 46 CFR 181.520 46 CFR 175.600(k)(I)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2023
Resolved 26 September 2023
Resolution: O/O installed fire extinguishers in brackets at proper locations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 June 2023 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Vessel lost steering control while underway with passengers. Repair steering system and perform operational test with attending Marine Inspector. 46 CFR 182.610(a)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 June 2023
Resolution: Operator re-pressurized the steering system. MI witnessed satisfactory op-test while underway.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 12 September 2022 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: (1) Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. (2) Where the station power exceeds 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a general radiotelephone operator license or higher class license. Captain of the vessel must hold a radio operator license. 47 CFR 80.159 (e)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2022
Resolved 21 October 2022
Resolution: Master presented valid permit
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 September 2022 Resolved
Glass and other glazing material used in windows accessible to passengers and crew must be of material that will not break into dangerous fragments if fractured. Marine Inspector observed a broken window on port side main deck that was taped. Replace window to the satisfaction of the attending Marine Inspector. 46 CFR 177.1010
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 21 October 2022
Resolution: Window replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 June 2021 Resolved
Bilge alarm in bow void #2 inoperable. Repair, demonstrated proper operation.
Action required: 10 - Deficiency Rectified
Resolved 16 June 2021
Resolution: Cleared on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2019 Resolved
Electrical Equipment exposed to the weather must be watertight.No lighting fixtures on the main deck. Provide light covers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 8 July 2019
Resolution: Lighting fixures were fitted with light covers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by origiating in electrical equipment, and electrical shock. Electrical cable found in the bilge of tank foward port side from removed ait conditioner unit. Install box for unused wires or remove cable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 10 July 2019
Resolution: Vessel installed a box for the unused wiring.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 25 June 2019 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station must carry a radio operator who meets the following requirments: where the station power doe snot exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator permit or higher class license.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 July 2019
Resolution: A radio operator permit was provided from the captain.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 June 2019 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by the FCC-licensed technician in accordance with 80.59 once every five years. Expired permit onboard. Have radio installation inspected. 47CFR80.903
Action required: 705 - Other - as specified
Resolved 8 July 2019
Resolution: Radio installation was inspected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 September 2018 Resolved
Operation of main engine shall be observed by [name withheld] repairs to port outdrive casing are made, sea trails with Marine Inspector must occur.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 September 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2018 Resolved
Replace fuel hoses in fuel system with approved type.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2018
Resolved 26 July 2018
Resolution: Hoses replaced.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 June 2018 Resolved
Provide copy of FCC Station License. 47 CFR 80.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2018
Resolved 9 July 2018
Resolution: FCC SL Provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 June 2018 Resolved
Repair/replace bilge piping for forepeak.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2018
Resolved 26 July 2018
Resolution: Piping replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2018 Resolved
Install battery tray cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2018
Resolved 26 July 2018
Resolution: New tray installed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 June 2018 Resolved
Prove proper operation of E/R bilge high level alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2018
Resolved 26 July 2018
Resolution: Tested SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 29 June 2018 Resolved
Provide COD.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2018
Resolution: COD provided.
Documentation › Certificates/Documents › FCC SSL
Issued 27 June 2017 Resolved
Provide current FCC Station License.
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 27 September 2017
Resolution: New Station license issued.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 27 June 2017 Resolved
Provide proof of drug and alcohol test program enrollment for all employees.
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 27 September 2017
Resolution: Proof of enrolment of employees provided.
Engineering › Bilge Water Management System › Piping
Issued 9 May 2016 Resolved
Ensure bilge piping has check valves for all spaces.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 11 May 2016
Resolution: Ensured footvalves were included in strainers at the temmination of each bilge pipe in each space. Valves were included. SAT.
Engineering › Bilge Water Management System › Piping
Issued 9 May 2016 Resolved
Repair/replace cracked bilge piping (fwd peak) at valve.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 25 May 2016
Engineering › Bilge Water Management System › Not Operational
Issued 9 May 2016 Resolved
Ensure proper Operation of bilge system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 May 2016
Resolution: Corrected on the spot.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 9 May 2016 Resolved
Repair exhaust leak on STBD engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 11 May 2016
Resolution: Exhaust leak had been fixrd prior to arrival and checked.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 9 May 2016 Resolved
Provide blank for open space in distribution panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 25 May 2016
Engineering › Generator (propulsion/auxiliary-electric) › Measurement Circuitry
Issued 9 May 2016 Resolved
Provide Amp meter for generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 May 2016
Resolution: Amp meter installed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 May 2016 Resolved
Complete MOB drills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 11 May 2016
Resolution: Complete MOB drill. UNDWY MOB drill was conducted. SAT.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 6 May 2016 Resolved
Provide donning plackard or all same type PFD.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 25 May 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.