Records from 2016 to 2024. Most recent: inspection, 20 August 2024.
Documentation record
Registered dimensions (L × B × D)109.5 ft × 30.0 ft × 18.5 ft
Registered tonnagegross 263 / net 124
ITC dimensions (L × B × D)104.5 ft × 30.0 ft × 17.6 ft
ITC tonnagegross 351 / net 105
BuilderNot recorded
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 23 May 2025 · expires 30 June 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it351 - Convention (Subpart B), Gross Ton
263 - Regulatory (Subpart C or D), Gross Ton
105 - Convention (Subpart B), Net Ton
124 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
20 August 2024
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7985282
12 December 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7838647
29 November 2022
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7598689
7 June 2022
Hull Examination · Internal Structural Exam · Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7472828
7 June 2022
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7585011
18 February 2022
Hull Examination · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7457468
24 December 2021
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7372221
24 August 2021
Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7294251
18 November 2020
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7096430
5 October 2020
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7071647
20 February 2020
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6912160
27 June 2019
Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6727125
20 February 2019
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6628893
13 December 2018
DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6597412
20 March 2018
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6383507
10 July 2017
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6204245
16 November 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6042252
27 October 2016
DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6034243
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 December 2023
Resolved
Vessel's fixed CO2 systems have not been serviced since 2021. Have fixed systems serviced prior to carrying passengers.
Cite: 46 CFR 78.17-80
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2024
Resolution: System has been serviced by Aztec Fire & Safety on 22 December 2023.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 December 2023
Resolved
Vessel's bilge suction system was inoperable. Demonstrate operation of the bilge suction system prior to carrying passengers.
Cite: 46 CFR 56.50-50
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2024
Resolution: Witnessed satisfactory test.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 December 2023
Resolved
Vessel's radio/phone were missing/inoperable. Provide a working radio or phone for the vessel's crewman to allow for rapid notification of emergency prior to carrying passengers.
Cite: 46 CFR 71.01-2
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2024
Resolution: Portable VHF radio provided.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 December 2023
Resolved
No emergency lights near the rear stairwells. Install sufficient emergency lighting in the vicinity of the aft stairwells prior to carrying passengers.
Cite: 46 CFR 112.15-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2024
Resolution: Additional emergency lights were installed and tested satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 December 2023
Resolved
Remove or properly terminate dead-end wire at base of foremast on main deck prior to carrying passengers.
Cite: 46 CFR 11.60-17
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2023
Resolution: Wires were properly terminated in a junction box.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 December 2023
Resolved
VHF-FM radio is inoperable. Repair/replace VHF-FM radio for use while underway and acquire an FCC Marine Radio Safety Telephony Certificate.
Cite: 46 CFR 71.01-2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2024
Resolved 8 January 2024
Resolution: A portable VHF is being used instead of the tagged out permanently installed VHF, so FCC documentation isn't required anymore.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 December 2023
Resolved
Permanently mount the electrical junction boxes and switch boxes in the forepeak and forward bathroom.
Cite: 46 CFR 11.81-1(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2024
Resolved 8 January 2024
Resolution: Boxes mounted appropriately.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 December 2023
Resolved
Fire extinguisher in forward tank space was found laying on its side on a shelf. Provide a manufacturer approved mounting bracket for the identified fire extinguisher.
Cite: 46 CFR 76.50-10(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2024
Resolved 8 January 2024
Resolution: Extinguisher mounted on approrpriate bracket.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 November 2020
Resolved
Trice up cable resting on heater in compartment A.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2020
Resolved 30 November 2020
Resolution: Heater removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 November 2020
Resolved
Replace 02 light bulbs for emergency lighting & mount light fixture in compartment B.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2020
Resolved 30 November 2020
Resolution: Bulbs replaced and fixture mounted.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 18 November 2020
Resolved
Prove proper operation of bilge alarm in compartment C.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2020
Resolved 30 November 2020
Resolution: Alarm tested in Comp. C.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 18 November 2020
Resolved
Mount light fixture in forward tank room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2020
Resolved 30 November 2020
Resolution: Fixture mounted.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 November 2020
Resolved
Provide annual CO2 servicing report for engine compartment. Vessel machinery shall not be operated until servicing is completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2020
Resolved 24 December 2021
Resolution: Provided documentation that fire system was serviced by Johnson Controls on Dec 2 2021.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 November 2020
Resolved
Properly display #2 fire station sign.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2020
Resolved 30 November 2020
Resolution: Placard posted, debris removed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 November 2020
Resolved
Repair seized valves and prove operation of #2 & #3 fire station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2020
Resolved 30 November 2020
Resolution: Valves overhauled, tested SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 November 2020
Resolved
Remove daisy chained power strip/ extension cord and provide proper outlet in radio room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2020
Resolved 30 November 2020
Resolution: J-Box and outlets installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 March 2018
Resolved
Remove unauthorized electric sump pumps from d, c, and engine compartments.
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 19 April 2018
Resolution: Pumps removed.
Electrical › Electric Generation Source (service) › Conductor
Issued 20 March 2018
Resolved
Remove unauthorized electric box fans from D and engine compartments.
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 19 April 2018
Resolution: Box fans removed.
Fire Fighting › Combustible Materials › Stowage
Issued 20 March 2018
Resolved
Provide fire wires as noted on the COI.
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 19 April 2018
Resolution: This issue was removed for the OCI all together.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 20 March 2018
Resolved
Remove loose wire from emergency battery bank.
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 19 April 2018
Resolution: Loose wire removed.
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 20 March 2018
Resolved
Prove all emergency lighting is functioning on-board.
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 19 April 2018
Resolution: All emergency lighting functioning.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 March 2018
Resolved
Remove electrical wires from bilges.
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 19 April 2018
Resolution: Wires removed from bilges.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 March 2018
Resolved
Remove all electrical wiring that is not authorized from vessel. (Extension cords)
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 19 April 2018
Resolution: Wiring removed.