BBC COLOMBIA

BBC COLOMBIA is a 1986 freight ship. The Coast Guard has recorded 22 inspections since 1987, most recently in October 2004, along with 30 deficiencies — 3 with no resolution recorded — and 6 operational controls, 1 with no removal date recorded.

Records from 1987 to 2004. Most recent: operational control imposed, 28 October 2004.

Built
1986
Last inspected
22 October 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8611946 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
277640
Flag
GERMANY
—
Maury page id
psix-277640

Inspections, by type

…with no type recorded18
…past their stated due date3
Years with a record 11 calendar years (1987–2004)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1645 - Convention (Subpart B), Net Ton
4250 - Dead Weight, Ton
3236 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

22 October 2004 PII Safety Exam · ISPS II Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2227729
1 March 2004 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2015852
1 March 2004 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2015863
31 October 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1939472
23 October 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1934274
19 February 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1488377
8 January 2002 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1476651
21 May 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 290216
24 October 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 283373
3 August 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 431497
23 January 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 424763
23 August 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 206711
23 August 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 419293
23 August 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 771358
24 February 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 413110
24 August 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 407095
10 May 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 391197
17 April 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 765431
16 April 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 206712
16 April 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 390214
10 January 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 374017
21 February 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 314549

Deficiency record · 30

Electrical › Lighting (service) › Lighting Branch Circuit
Issued 22 October 2004 No resolution recorded
Discovered, (temporary repair with electrical tape) lighting cable in emergency generator room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 November 2004 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Piping
Issued 22 October 2004 No resolution recorded
Discovered soft patch on ballast water system, (below engine room deck plating, port side forward).
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 November 2004 — due date passed with no resolution recorded
Fire Fighting › Fire Main › Material
Issued 22 October 2004 No resolution recorded
Discovered soft patch, (engine room, above main fire pump, stbd side forward). Ship maintained adequate fire main pressure during test.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 November 2004 — due date passed with no resolution recorded
Fire Fighting › Structural - A Class Divisions
Issued 23 October 2003 Resolved
Two class "A" and two class "B" self closing fire fighting doors are inoperative. 74 Solas II-2 Reg 30 Repair to the satisfaction of Safety Construction Issuing Authority. Prior to departing port. LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2003
Resolution: Rcv''d class rpt atesting to repairs.
Fire Fighting › Ventilation Systems
Issued 23 October 2003 Resolved
Several fire damper and vent closures are inoperative. Prove proper operation of all fire dampers and vent closures to the Satisfaction of the Safety Construction Issuing Authority. Prior to departing port 74 Solas II-2 Reg 48
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2003
Resolution: Rcv''d class rpt attesting to repairs.
Fire Fighting › Fire Hoses
Issued 23 October 2003 Resolved
Replace all damaged and wasted fire hoses to the satisfaction of the Safety Equipment Certificate Issuing Authority. 74 Solas II-2 Reg 4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2003
Resolution: Rcv''d class rpt attesting to repairs.
Deck/Cargo › Holds/Tanks
Issued 23 October 2003 Resolved
Hydraulic oil lines to cargo hold rams are leaking. Repair to the satisfaction ot the Safety Construction Certificate Issuing Authority. Make repairs prior to 22 Nov 2003. 74 Solas II-1 Reg 45 LEGACY COMPONENT DESC: Hatch Hydraulic Rams
Due 22 November 2003
Resolved 17 November 2003
Electrical › Lighting (service)
Issued 23 October 2003 Resolved
Repair port side deck lighting insulation to the satisfaction of the Safety Construction Issuing Authority. Make repairs no later than 22 Nov 2003. 74 Solas II-1 Reg 21 LEGACY COMPONENT DESC: Lighting Fixture
Due 22 November 2003
Resolved 17 November 2003
Lifesaving › Buoyant Apparatus
Issued 23 October 2003 Resolved
Replace all damaged and wasted life rings, floating lights and applicable mounting hardware to the satisfaction ot he Safety Equipment Issuing Authority. Make repairs no later than 05 Nov 2003. 74 Solas III Reg 21 LEGACY COMPONENT DESC: Life Ring
Due 17 November 2003
Resolved 17 November 2003
Navigation
Issued 23 August 2001 Resolved
Charts and Pubs for Great Lakes to be supplied
Condition: Unknown
Due 1 September 2001
Resolved 8 January 2002
Resolution: CLEARED VIA FAX 01 DEFICIENCY THAT WAS ISSUED ON 23AUG01. 04 DEFICIENCIES REMAIN OUTSTANDING.
Navigation
Issued 21 May 2001 Resolved
VESSEL NEEDS TO CARRY CURRENT BA CHART 2564 BEFORE LEAVING THE PORT. AGENTWILL FAX COPY OF PURCHASE.
Condition: Unknown
Due 24 May 2001
Resolved 29 May 2001
Electrical
Issued 24 October 2000 Resolved
WRENCHES IN CONTROL PANEL SECURING HANDLE FOR WINCH. SOLAS 74 (AMD)II-1 REG 45/1.3
Condition: Unknown
Due 22 May 2001
Resolved 22 May 2001
Navigation
Issued 24 October 2000 Resolved
EXCESSIVE OIL IN VICINITY OF STEERING COMPARTMENT. SOLAS 74 (AMD) II-1 REG29/12.1
Condition: Unknown
Due 27 November 2000
Resolved 27 November 2000
Navigation
Issued 24 October 2000 Resolved
MORE THAN 5 DEGREES DIFFERENCE BETWEEN RUDDER ANGLE INDICATOR ON BRIDGE ANDIN STEERING COMPARTMENT. SOLAS 74 (AMD) II-1 REG29/2.1
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Navigation
Issued 24 October 2000 Resolved
DROOPING LINE INTERFERING WITH OPERATION OF STEERING GEAR. SOLAS 74 (AMD) II-2 REG 29/13
Condition: Unknown
Due 27 November 2000
Resolved 27 November 2000
Lifesaving
Issued 24 October 2000 Resolved
OILY RAGS STORED IN ENGINE ROOM. SOLAS 74 (AMD) REGI/11
Condition: Unknown
Due 27 November 2000
Resolved 27 November 2000
Accommodation/Occupational Safety
Issued 24 October 2000 Resolved
OBSTRUCTIONS STORED IN EMERGENCY EXITS. SOLAS 74 (AMD) II-2 REG 45/3
Condition: Unknown
Due 27 November 2000
Resolved 27 November 2000
Documentation
Issued 24 October 2000 Resolved
PROVIDE INSTRUCTIONS FOR OILY WATER SEPERATOR IN A LANGUAGE OF THE CREW. MARPOL 73/78 ANNEX I REG 16 (4&5)
Condition: Unknown
Due 27 November 2000
Resolved 27 November 2000
Navigation
Issued 3 August 1999 Resolved
Rudder stock leaking excessive water, unusual noise and vibration._x001C_ SOLAS 74 II-1/29
Condition: Unknown
Due 3 August 1999
Resolved 7 August 1999
Accommodation/Occupational Safety
Issued 24 February 1998 Resolved
MISSING SECTION OF HANDRAIL ABOVE MAIN DIESEL ENGINE PORT SIDE AS PER ILO- 147.
Condition: Unknown
Due 30 March 1998
Resolved 26 February 1998
Navigation
Issued 24 February 1998 Resolved
BRIDGE RUDDER ANGLE INDICATOR AND RUDDER POST INDICATOR MISALIGNED BY 5-9 DEGREES AS PER SOLAS 74 II-1/29.11
Condition: Unknown
Due 25 February 1998
Resolved 26 February 1998
Navigation
Issued 24 February 1998 Resolved
NO NAVIGATION CHARTS FOR THE HOUSTON SHIP CHANNEL AS PER SOLAS 74 V/20.
Condition: Unknown
Due 25 February 1998
Resolved 26 February 1998
Construction/Loadline
Issued 16 April 1996 Resolved
Provide class report on buckle/hairline fracture stbd side engine room above OWS discharge at hull.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Lifesaving
Issued 16 April 1996 Resolved
Properly stow paints and thinners out of steering room.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Construction/Loadline
Issued 16 April 1996 Resolved
Permanently mark and paint reference line for loadline prior to return to next U.S. port.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Documentation
Issued 16 April 1996 Resolved
Provide oil transfer procedures prior to any fuel transfer or bunkering.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Navigation
Issued 16 April 1996 Resolved
Provide current coast pilot and light list.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996
Documentation
Issued 16 April 1996 Resolved
Provide a SOLAS Safety Equipment Certificate using correct form. Existing certificate is not a SOLAS document.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Documentation
Issued 16 April 1996 Resolved
Provide evidence of valid licensed chief engineer on board prior to departure from MSO Miami COTP zone.
Condition: Unknown
Due 19 April 1996
Resolved 18 April 1996
Deck/Cargo
Issued 16 April 1996 Resolved
Provide fixed containment for bulk lube oil fills prior to receiving any lube oil.
Condition: Unknown
Due 14 May 1996
Resolved 14 May 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.