GRAND CELEBRATION is a 1987 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2016, most recently in September 2020, along with 16 deficiencies and 2 operational controls.
Records from 2016 to 2020. Most recent: inspection, 3 September 2020.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it47262 - Convention (Subpart B), Gross Ton 6453 - Dead Weight, Ton 26944 - Displacement, Ton 25387 - Convention (Subpart B), Net Ton 47262 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 28
3 September 2020MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7049937
8 April 2020In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6937111
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 February 2020Resolved
01 Code 07113 An independent power pump shall be provided solely for the purpose of continuing automatically the discharge of the water from the sprinklers. During testing of section valves the sprinkler pump motor failed to operate and was unable to provide sufficient pressure to the sprinkler system.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 4 February 2020
Resolved 4 February 2020
Resolution: Recieved class report attesting to the proper operation of the newly installed fire pump. BV ran test of pump for 30 minutes and tested 9 section valves with no discrepencies noted. Vessel is cleared to depart.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 4 February 2020Resolved
02 Code 15109 The company shall establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations... In meeting these requirements the company shall ensure inspections are held at appropriate intervals. PSCO found conflicting test intervals for the sprinkler section valve test, some being weekly, some being monthly as per manufacturer recommendations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 18 February 2020
Resolution: Verified updated testing procedures for sprinkler system and fire pump.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 February 2020Resolved
03 Code 07105 Fire door in main vertical zone bulkheads shall be of the self-closing type. The speed of the door closure shall be controlled so as to prevent undue danger to persons. Found the following fire screen doors not operating as designed. FSD09.5.03 SD09.5.56A FSD08.501B SD09.5.56 FSD08.5.51A FSD08.2.51B SD8.3.00 SD07.4.18
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 18 February 2020
Resolution: Verified operations of FSD's. Doors on average took 1 1/2 minutes to close, but did not pose hazard to passengers from closing speed. Due to the age of the vessel, there is no time requirement for the closing speed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 July 2019Resolved
01 Code 07101 The minimum fire integrity of the bulkheads and decks shall be as prescribed in tables 26.1-26.4. PSCOs found penetrations in A60 boundary located on deck 3 (03.3.28) above door. 74 SOLAS(81 AMENDMENTS)11-2/26.1.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 July 2019
Resolved 31 July 2019
Resolution: Vessel had welder on board. Sealed penetrations. Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 31 July 2019Resolved
02 code 11108 Liferafts shall be stowed with a float-free arrangement, so that each floats free and if inflatable, inflates automatically when the ship sinks. 03 liferafts on starboard side station and 01 liferafts at port station were improperly installed and were not able to automatically inflate due to improper installation of the painter lines to weak link line of release device. 74SOLAS(04 CONS)111/31.3.1.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 31 July 2019
Resolved 31 July 2019
Resolution: Painter lines porperly connected to weak link as designed. PSCO attested to proper installation. Corrected on spot.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 July 2019Resolved
03 code 18408 Electrical installations shall be such that the safety of passengers, crew, and the ship will be ensured. Housekeeping office on deck 3 aft has temporary 110 volt and 220 volt wiring not in permanent setting. 74SOLAS(14 CONS)11-1/40.1.3.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 August 2019
Resolved 2 August 2019
Resolution: Vessel provided documentation clearing deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 1 February 2019Resolved
Davits, Falls, Blocks and all other gear shall be of such strength that the lifeboats can be turned out, manned by a launching crew and then safely lowered. The lower sheave on the aft davit for lifeboat No. 12 was damaged during lowering operation performed prior to exam. Lowereing of LB # 12 was not possible and the RO issued an interim PSSC reducing capacity to 2218. Upon further inspection, lifeboat 11 was also identified to have issues related to wastage in the vicinity of the sheaves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2019
Resolved 17 July 2019
Resolution: Received class report for the satisfactory completion of repairs to #11 & #12 lifeboat davits.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 August 2018Resolved
Before a ship leaves port and at all times during the voyage, all live saving applipances shall be in working order and ready to immediate use. Lifeboat #7 port side propeller had a 1/4 to 1/2 inch crack on one of the blades. 74SOLAS 92 Cons. CH III/Reg 19.2.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 8 August 2018
Resolved 8 August 2018
Resolution: Vessel replaced propeller with spare propeller onboard vessel.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 August 2018Resolved
Fire integrity values identified in regulation 26, table 26.2 shall apply to bulkheads not bounding either main vertical zones or horizontal zones. Liquor was found in a category 13 space, deck 2, frames 12-24. 74SOLAS 92 cons. CH II-2/Reg 26.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2018
Resolved 19 September 2018
Resolution: A-Class FSD installed, converting the space to category 14 from 13.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 2 February 2017Resolved
0799-The minimum fire integrity of the bulkheads and decks shall be as prescribed in tables 26.1 to 26.4. PSCO found penetrations on A0 boundary in galley deck 8 and A/C locker 801/802 SOLAS(81 AMEND) CHAP II-2 REG 26.1 ACTION-A16
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 9 February 2017
Resolution: received report and visual proof of proper closure of exposed A) bounderies. See attached documents
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 2 February 2017Resolved
Condition of the ship and its equipment shall be maintained to conform with the present regulations. Rolling shutter for the deep fat fryer on deck 10 main pool grill is not closing properly. SOLAS (14 CONS) CHAP I REG 11. ACTION-A16
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 3 February 2017
Resolution: PSCO witnessed proper operation of the rolling shutter.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 2 February 2016Resolved
Waste receptacles shall be non-combustible with no opening on side. Observed numerous combustible waste receptacles located throughout ship
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 16 February 2016
Resolution: non-combustible waste receptacles removed
Fire Fighting › Means of Escape › Escape Route Signs
Issued 2 February 2016Resolved
In addition to lighting, means of escape including stairway and exits shall be marked by lighting or strip indicators. Stairwell adjacent to the crew galley does not have low level lighting or signage.
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 2 February 2016
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 2 February 2016Resolved
Conditions of the ship and its equipment shall be maintained to conform with present regulations. Insulation missing in void space number 2, Deck 2,
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 16 February 2016
Resolution: insulation in affected area restored
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 2 February 2016Resolved
Where the contents and use of a space are such that there’s doubt to its classification or purpose, it shall be treated as such with most stringent requirements. Spaces are being utilized for storage improperly throughout the ship.
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 16 February 2016
Resolution: storage items were removed from spaces not categorized for storage.
Fire Fighting › Means of Escape › Doorways
Issued 2 February 2016Resolved
Escape doors from public spaces that are normally latched shall be fitted with means of quick release and not equipped with locking devices. Locks are equipped on glass doors on deck 11 (kids area) and deck 8 (admiralty lounge).
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 16 February 2016
Resolution: Locks were removed in affected area