Records from 1987 to 2006. Most recent: inspection, 27 September 2006.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
27 September 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2787863
5 August 2006
ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2733787
12 May 2003
Security Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1791709
11 May 2003
Type not recorded
No type recorded · STATION (SM) BOSTON · USCG Northeast District (CGD-NE) · Activity 1796512
5 May 2003
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1786728
14 April 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1773459
13 April 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1772878
12 April 2003
Type not recorded
No type recorded · GROUP LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1772731
10 March 2003
Annual Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1751678
5 October 2002
Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1686538
14 January 2002
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1478468
5 January 2002
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1475791
22 January 1999
Quarterly Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1384030
21 September 1998
Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1368860
18 September 1998
Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 420283
30 September 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 486359
30 September 1997
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1119543
2 October 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 512127
27 October 1995
Administrative
Administrative · Marine Safety Center (MSC) · Activity 1186343
7 September 1995
MARPOL Annex V Examination · MARPOL Annex I Examination · Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1185031
20 February 1995
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 375544
22 December 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 846755
8 February 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 364440
31 January 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 364190
31 January 1994
MARPOL Annex V Examination · Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1366968
19 April 1993
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1149296
14 January 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 690939
10 January 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 355654
10 January 1993
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 829020
14 December 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 826492
6 September 1992
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1245643
1 September 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 517300
20 February 1987
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1323936
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 August 2006
No resolution recorded
Ship has installed a dry cleaning unit in the main laundry. Properly install the power supply cable to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 5 September 2006 — due date passed with no resolution recorded
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 5 August 2006
No resolution recorded
AC Room on the aft "B" deck has excessive stores inside. Remove all the stores or have this space reclassified as a store room, to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 5 August 2006 — due date passed with no resolution recorded
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 5 August 2006
Resolved
Vessel to provide proof that a Non Tank Vessel Response plan has been submitted to G-PCV-1 for review, as per NVIC 01-05 change 1.
Action required: 705 - Other - as specified
Resolved 8 August 2006
Resolution: Received confirmation that NTVP has been submitted for review.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 5 August 2006
Resolved
Sales shops (Cat 7 space) are separated from a corridor (Cat 3 space) by only glass with no proof of the fire rating of this glass, these corridors lead directly into a stair tower. Provide proof that this arrangement meets the Retro Fire Safety Amendments which does not allow a Category 7 space to lead directly into a stair tower SOLAS 74 II-2 41.2.4.5.
Action required: 705 - Other - as specified
Due 5 September 2006
Resolved 27 September 2006
Resolution: Received report from Germanischer Lloyd showing vessel built to SOLAS 74 81 Amendments. Spaces considered Cat 8.
Documentation › Certificates/Documents › Control Verification for Foreign Vessel (CG4504)
Issued 5 August 2006
No resolution recorded
Vessel must go through the US Coast Guard Control Verification Program, if the vessel embarks passengers in the United States or carries a US Citizen as a passenger. 46 USC 3505, Public Law 108-293 August 9, 2004.
Action required: 705 - Other - as specified
Navigation › Piloting/Steering
Issued 5 January 2002
Resolved
Missing steering block diagram on bridge. Corrected on the spot LEGACY COMPONENT DESC: steering gear instruction
Condition: Improper/Lack of Maintenance
Due 5 January 2002
Resolved 5 January 2002
Resolution: Corrected on the spot.
Fire Fighting
Issued 22 January 1999
No resolution recorded
Provide smoke detectors for storage closet in sauna room and main laundry staircase IAW SOLAS 74 amended II-2/41-2.
Condition: Unknown
Due 22 February 1999 — due date passed with no resolution recorded
Resolution: Corrected
Fire Fighting
Issued 22 January 1999
No resolution recorded
Provide remote releases for fire doors at main laundry IAW SOLAS 74 amendedII-2/41-2.
Condition: Unknown
Due 22 February 1999 — due date passed with no resolution recorded
Resolution: Corrected
Engineering
Issued 31 January 1994
Resolved
MISSING DESCRIPTION OF OIL PRODUCTS AND FIRST AID INFORMATION ON OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Documentation
Issued 10 January 1993
Resolved
OIL TRANSFER PROCEDURES NOT IN LANGUAGE OF THE CREW.
Condition: Unknown
Due 8 February 1994
Resolved 8 February 1994
Accommodation/Occupational Safety
Issued 10 January 1993
Resolved
REVISE EMERGENCY EXIT SIGNS AND EXIT SIGNS ON SHIP WITH EXCEPTION OF ENGINEROOM TO CLEARLY MARK EXITS. THESE MARIKINGS SHOULD AGREE WITH THE APPROVEDESCAPE PLANS. PLANS HAVE BEEN SENT TO MSC ACCORDING TO COMPANY REP. REQUIREMENT FIRST ISSUED 6 SEPT 92 BY NYCMI (REF CASE MI92033875).
Condition: Unknown
Due 10 January 1993
Resolved 10 January 1993
Fire Fighting
Issued 10 January 1993
Resolved
LAUNDRY CHUTE DOORS OPEN DIRECTLY INTO MAIN STAIRWAY. THESE SHOULD BE SECURED TO COMPLY WITH REG.II-2/29.2. REQUIREMENT FIRST ISSUED MI92033875.LIBRARY, CARD ROOM AND PANTRY (IN CREW STAIRS) HAVE DIRECT ACCESS TO STAIRWAY. THESE SPACES TO BE IN COMPLIANCE BY 1997 AMENDMENTS.
Condition: Unknown
Due 10 January 1993
Resolved 10 January 1993
Fire Fighting
Issued 10 January 1993
Resolved
REPLACE PLATE GLASS IN DISPLAY CASES IN JEWLERS SHOP ON THE PROMANADE DK WITH FIRE RESISTANT GLASS TO B-15 AS REQUIRED BY ITEM 12 [name withheld]92033875/ OR VESSEL TO PROVIDE DOCUMENTATION THAT THIS GLASS WAS REPLACEDIN LAST YARD PERIOD WITH THE PYRON TYPE GLASS PREVIOUSLY ACCEPTED BY CLASS.
Condition: Unknown
Due 10 January 1993
Resolved 10 January 1993
Documentation
Issued 10 January 1993
Resolved
VESSEL TO ENSURE ALL CREW (INCLUDING CONSESSIONAIRES CREW MEMBERS) HAVE MEDICAL CERTIFICATES AS REQUIRED BY I.L.O. 147.
Condition: Unknown
Due 10 January 1993
Resolved 10 January 1993
Fire Fighting
Issued 10 January 1993
Resolved
MODIFY GLASS DOORS ON EXISTS FROM RESTAURANT SO THAT WHEN FIRE SCREEN DOORSARE CLOSED THEY DO NOT BLOCK THE HANDLES TO THE DOORS.
Condition: Unknown
Due 10 January 1993
Resolved 10 January 1993
Accommodation/Occupational Safety
Issued 6 September 1992
Resolved
LAUNDRY CHUTE DOORS OPEN DIRECTLY INTO MAIN STAIRWAY. THESE SHOULD BE SECURED TO COMPLY WITH REG 29.2 PROTECTION OF STAIRWAYS.
Condition: Unknown
Due 6 September 1992
Resolved 6 September 1992
Accommodation/Occupational Safety
Issued 6 September 1992
Resolved
REPLACE PLATE GLASS IN DISPLAY CABINETS WITH FIRE RESISTANT GLASS TO B-15 CLASS INTEGRITY OF THESE BULKHEADS IN WAY OF SHOPS ON THE PROMENADE DECK.
Condition: Unknown
Due 6 September 1992
Resolved 6 September 1992
Accommodation/Occupational Safety
Issued 6 September 1992
Resolved
DOCUMENT THAT BOUNDARY BULKHEADS BETWEEN THE SALES SHOP AND PORT AND STARBOARD GALLERIES ARE NOT LESS THAN B-15 CLASS, INCLUDING GLASS.
Condition: Unknown
Due 6 September 1992
Resolved 6 September 1992
Accommodation/Occupational Safety
Issued 6 September 1992
Resolved
BULKHEAD EXTENSIONS ABOVE THE GLASS BULKHEADS ON THE PROMENADE DECK SHALL BE MADE TO B-CLASS.
Condition: Unknown
Due 6 September 1992
Resolved 6 September 1992
Fire Fighting
Issued 6 September 1992
Resolved
RESUBMIT THE ESCAPE PLAN WHICH WAS MODIFIED BY THE OWNERS REPS DURING CVE TO THE CLASS SOCIETY OR FLAG ADMIN FOR APPROVAL. THEN RESUBMIT ESCAPE PLAN TO USCG MARINE SAFETY CENTER FOR REVIEW. THE APPROVED ESCAPE PLAN MUST BE AVAILABLE TO THE USCG AT NEXT CVE.
Condition: Unknown
Due 6 September 1992
Resolved 6 September 1992
Accommodation/Occupational Safety
Issued 6 September 1992
Resolved
REVISE EMERGENCY EXIT SIGNS AND EXIT SIGNS ON SHIP WITH EXCEPTION OF ENGINEROOM TO CLEARLY MARK EXITS. THESE MARKINGS SHOULD AGREE WITH APPROVED ESCAPE PLAN.
Condition: Unknown
Due 6 September 1992
Resolved 6 September 1992
Accommodation/Occupational Safety
Issued 6 September 1992
Resolved
DOUBLE KEY LOCKS IN WAY OF ESCAPE DOORS SHOULD BE REMOVED SO THAT "MEANS OFESCAPE" ARE NOT BLOCKED BY LOCKED DOORS IN ANY CASE.
Condition: Unknown
Due 6 September 1992
Resolved 6 September 1992
Accommodation/Occupational Safety
Issued 6 September 1992
Resolved
INSTALL A B-CLASS BOUNDARY BETWEEN THE CORRIDOR / FOYER AND THE PURSER'S OFFICE. IN THE INTERIM THE MASTER SHALL ENSURE THAT THE STORAGE OF COMBUSTIBLES IN THE PURSERS OFFICE IS KEPT TO A BARE MINIMUM.
Condition: Unknown
Due 6 September 1992
Resolved 6 September 1992
Accommodation/Occupational Safety
Issued 6 September 1992
Resolved
THE PYRAN GLASS INSTALLED IN B-CLASS BULKHEADS IN WAY OF ENCLOSED SHOPPING AREAS OF PROMONADE DECK SHALL BE FIRE RESISTANT.
Condition: Unknown
Due 6 September 1992
Resolved 6 September 1992
Accommodation/Occupational Safety
Issued 6 September 1992
Resolved
REPLACE THE C-CLASS DOORS INSTALLED IN B-CLASS BULKHEADS THROUGHOUT VESSEL,DOORS IN WAY OF SHOPS SHOULD BE GIVEN PARTICULAR ATTENTION.
Condition: Unknown
Due 6 September 1992
Resolved 6 September 1992