Records from 2006 to 2025. Most recent: inspection, 6 November 2025.
Inspection history · 20
6 November 2025
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8261355
27 October 2025
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8259083
29 January 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8072305
12 February 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7864456
20 November 2023
Internal Structural Exam · Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7827484
8 February 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7634950
27 July 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7517583
25 January 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7385968
7 December 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7364134
3 December 2021
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7361766
17 November 2020
DAPI Audit · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7096350
14 January 2020
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6889391
3 December 2019
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6874563
5 February 2019
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6620274
24 April 2018
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6395707
5 December 2017
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6314978
21 March 2017
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6104894
7 June 2016
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5900635
7 June 2016
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5900984
12 January 2016
COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5795509
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 27 October 2025
No resolution recorded
O/O must enroll with consortium as a Marine Employer and provide a Drug and Alcohol Policy, Employee Assistance Program (EAP) and Supervisor Training to crew.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 February 2024
Resolved
The vessel requires (3) fire buckets but only (2) are onboard. Get (1) more fire bucket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2024
Resolved 29 January 2025
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 12 February 2024
Resolved
The vessel requires bilge high level alarms in all spaces with hull valves. The generator compartment did not have a high water alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2024
Resolved 27 October 2025
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 February 2024
Resolved
The generator is rated for 40 Celsius and needs to be derated top 80% full load rating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2024
Resolved 29 January 2025
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 February 2024
Resolved
Supervisor training must be provided to a member of the crew to determine whether reasonable suspicion exits to require a drug and/or alcohol test. No one has been provided this training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2024
Resolved 27 October 2025
Resolution: Re-issued.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 November 2020
Resolved
Secure Breaker Panel
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 10 December 2020
Resolution: Breaker panel properly secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 November 2020
Resolved
Label breakers on electrical panel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 10 December 2020
Resolution: All breakers have been properly labled on electrical panel.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 17 November 2020
Resolved
Replace folding ladder with Heavy Duty Ladder.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2020
Resolved 7 December 2021
Resolution: Attended vessel and verified new Heavy Duty Ladder.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 November 2020
Resolved
Replace 4 Lifejackets. Passenger count reduced to 19 until discrepancy is fixed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 December 2020
Resolution: Master replaced 4 adult life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 November 2020
Resolved
Missing placard for donning lifejacket.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 December 2020
Resolution: Master has provided proof of new donning placard for life jackets.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 November 2020
Resolved
Inoperable Smoke Detector in Berthing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 10 December 2020
Resolution: Smoke detector in forward berthing space has been replaced with new operational device.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 November 2020
Resolved
Dead end wires located in the starboard rack, under the starboard sink and the forward engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 10 December 2020
Resolution: Dead end wires located in starboard rack, under the starboard sink have been adjusted for safety concerns.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 November 2020
Resolved
Mount receptacle in galley area.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 10 December 2020
Resolution: Galley receptacle properly mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 November 2020
Resolved
Secure generator exhaust hanger.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 10 December 2020
Resolution: Generator exhaust properly secured in Engine Room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 November 2020
Resolved
Properly mount engine room bilge pump
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 10 December 2020
Resolution: Bilge pump properly mounted in the Engine Room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 November 2020
Resolved
Replace hose sectioned fuel lines
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 16 December 2020
Resolution: Hoses removed and copper tubing installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 November 2020
Resolved
DSC function inoperable. Provide proof of proper functionality.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2020
Resolved 10 December 2020
Resolution: DSC radio operational and functional.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 November 2020
Resolved
Properly mount A/C sea strainer.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 10 December 2020
Resolution: A/C sea strainer properly mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 November 2020
Resolved
Properly mount live well. Start Solenoid.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 10 December 2020
Resolution: Live well start solonoid properly mounted in Engine Room.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 November 2020
Resolved
Properly mount battery switch for pilot house. 12v system
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 10 December 2020
Resolution: Battery Switch for Pilot House 12V system, properly mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 November 2020
Resolved
Double hose clamp sewage discharge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 10 December 2020
Resolution: Sewage discharge double hose clamped.
Construction/Loadline › Hull › Side Shell
Issued 7 June 2016
Resolved
Haul vessel out to allow damage survey of hull structure following marine casualty
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 8 June 2016
Resolution: Vessel completed out of water hull damage survey
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 7 June 2016
Resolved
Following satisfactory hull inspection conduct underway operational test and systems test.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 21 June 2016
Resolution: Vessel conducted sat underway checks
Lifesaving › Lifefloat › Serviceable
Issued 7 June 2016
Resolved
Replace damaged unserviable lifefloat
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 16 June 2016
Resolution: Vessel replaced lifefloat
Construction/Loadline › Structures › Superstructure
Issued 7 June 2016
Resolved
Prior to making any repairs approval is required from USCG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 8 June 2016
Resolution: Repairs have been approved by USCG
Engineering › Bilge Water Management System › Interface Detector
Issued 12 January 2016
Resolved
Replace V berth indicating light for high level alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 January 2016
Resolved 13 January 2016
Resolution: Vesse; re[;aced alarm
Construction/Loadline › Structures › Scuttle
Issued 12 January 2016
Resolved
Reqork steering hatch so it can be opened without tools
Action required: 705 - Other - as specified
Due 26 January 2016
Resolved 13 January 2016
Resolution: Vessel reworked hatch
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 12 January 2016
Resolved
Provide lifesaving appliance for rescuing a person out of the water.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 January 2016
Resolved 13 January 2016
Resolution: Vessel provided appliance