FUN RUNNER

FUN RUNNER is a 1987 passenger vessel (inspected). The Coast Guard has recorded 58 inspections since 1987, most recently in May 2025, along with 54 deficiencies and 1 operational control.

Records from 1987 to 2025. Most recent: inspection, 13 May 2025.

Built
1987
Last inspected
13 May 2025
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

277719
Flag
UNITED STATES
—
Maury page id
psix-277719

Inspections, by type

…with no type recorded5
Years with a record 34 calendar years (1987–2025)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.0 ft × 14.0 ft × 7.0 ft
Registered tonnagegross 27 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMUNSON MANUFACTURING INC. · EDMONDS, WA, UNITED STATES · built 1987
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portLAKE TAHOE, CA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Simplified, Gross Ton
22 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 58

13 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8135389
14 May 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7909447
16 May 2023 COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7681302
29 April 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7440851
20 September 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7316689
22 June 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7242382
5 October 2020 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7070187
31 July 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7037701
22 July 2019 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6761706
15 May 2019 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6761166
23 May 2018 Administrative Inspection · Internal Structural Exam · DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6415301
8 May 2017 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6137608
17 November 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6053705
18 August 2014 Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4965834
11 March 2014 Annual Inspection · Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4881494
16 May 2012 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4391043
16 June 2008 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3242962
14 December 2007 Hull Examination · Plan Review "T" Boat · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3115684
19 September 2007 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3061333
18 October 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2803265
9 May 2006 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2640843
5 May 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2353877
1 July 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2117885
12 May 2004 Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2095683
24 June 2003 In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1809527
29 May 2003 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1808548
23 August 2002 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1667674
27 May 2002 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1626521
2 November 2001 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1458012
21 August 2001 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1435269
3 May 2001 Excursion Permit
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1064259
26 July 2000 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1436443
16 June 1999 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 881285
19 May 1999 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1384158
28 April 1999 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 791591
23 June 1998 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1127461
27 June 1997 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1107116
13 November 1996 Hull Examination
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1180486
5 June 1996 COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1082326
21 June 1995 Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1191318
5 June 1995 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 873008
22 June 1994 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1331378
31 May 1994 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 860299
10 June 1993 COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1136672
9 June 1992 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1263281
12 May 1992 Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 954441
29 October 1991 Hull Examination
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 942698
28 October 1991 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 939101
17 July 1991 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1353167
4 June 1991 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 907667
11 June 1990 COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1215332
10 August 1989 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1343102
15 June 1989 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1351021
10 June 1988 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1198083
22 February 1988 Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1023600
29 July 1987 Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1025203
13 July 1987 Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1015871
9 June 1987 Hull Examination · Initial Certification
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1336611

Deficiency record · 54

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards. Engine room outfitted with four main batteries. Second inboard from port found with five connections on one terminal. Reduce connections to no more than four. 46 CFR 183.200 ABYC E-9
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 28 May 2025
Resolution: Accepted photo for correction.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 May 2025 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of person who have fallen overboard; the master shall conduct sufficient fire drills to make sure that each crew member is familiar with their duties. Drill logs not available for inspection. 46 CFR 185.520 46 CFR 185.524
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 28 May 2025
Resolution: Accepted photo for correction.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 22 June 2021 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Port and starboard main engine shafts were not suitably protected to prevent injury to personnel. Install cover or guard over both shafts.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2021
Resolved 28 October 2021
Resolution: Received photos showing installed guards.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2019 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Only 42 of the required 44 life jackets were available for inspection. Provide two additional Coast Guard approved life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 24 July 2019
Resolution: Provided 2 additional adult life jackets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2019 Resolved
All emergency exits used as means of escape must be marked on both sides in clearly legible letters. The method of exit in an emergency was unclear. Properly label means of escape.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 23 July 2019
Resolution: Properly labeled emergency exits.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 May 2017 Resolved
Ring buoy was not marked with vessel's name. - 46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 8 May 2017
Resolution: Operator marked ring buoy IAW 46 CFR 185.604(b).
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2017 Resolved
Several wires in fuel tank compartment were reinforced with duct tape. Vessel required to remove duct tape and protect with acceptable material. - 46 CFR 183.340(n)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 8 May 2017
Resolution: Operator removed duct tape and properly protected wires with suitable electrical insulation IAW 46 CFR 183.340(n).
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 December 2016 Resolved
Conduct satisfactory annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2017
Resolution: Satisfactory annual exam conducted on 09MAY2017
Construction/Loadline › Hull › Weld
Issued 14 December 2007 Resolved
Repair crack in two bilge stringers where they cross under the port engine.
Action required: 705 - Other - as specified
Resolved 25 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 14 December 2007 Resolved
Provide proof onboard of Drug and Alcohol program compliance.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2008
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 14 December 2007 Resolved
Properly post emergency instructions list for passengers to see.
Due 11 July 2008
Resolved 16 June 2008
Engineering › Fuel Oil Service System › Vent Pipe
Issued 14 December 2007 Resolved
Install 30 X 30 mesh flame screens fuel oil vent IAW 46 CFR 182.450 (e).
Due 11 July 2008
Resolved 16 June 2008
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 14 December 2007 Resolved
Provide onboard portable lighting IAW 46 CFR 183.430
Due 11 July 2008
Resolved 16 June 2008
Lifesaving › Hand Flares › Not on Board
Issued 14 December 2007 Resolved
Provide onboard required visual distress signals IAW 46 CFR 180.60 (b) (1) (2).
Due 11 July 2008
Resolved 16 June 2008
Construction/Loadline › Hull › Bottom Plating
Issued 14 December 2007 Resolved
Complete satisfactory drydock exam.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2008
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 18 October 2006 Resolved
Complete credited Hull exam prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2007
Resolved 19 September 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 May 2006 Resolved
Conduct underway drills (fire and man overboard) to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 31 December 2006
Resolved 19 September 2007
Lifesaving › Buoyant Smoke Signals › General
Issued 9 May 2006 Resolved
Provide 3 orange day smoke signals as required.
Action required: 705 - Other - as specified
Due 9 May 2006
Resolved 9 May 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 May 2006 Resolved
Prove proper operation of waterlight on buoyant apparatus.
Action required: 705 - Other - as specified
Due 9 May 2006
Resolved 9 May 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 May 2006 Resolved
Relabel vessel's name on lifebuoy- markings have faded.
Action required: 705 - Other - as specified
Due 9 May 2006
Resolved 9 May 2006
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 May 2006 Resolved
Relable stowage of child lifejackets to coincide correctly with the amount required.
Action required: 705 - Other - as specified
Due 9 May 2006
Resolved 9 May 2006
Lifesaving › Buoyant Apparatus › Marking
Issued 9 May 2006 Resolved
Relabel buoyant apparatus with vessel's name- marking has faded.
Action required: 705 - Other - as specified
Due 9 May 2006
Resolved 9 May 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 May 2005 Resolved
Renew waterlight batteries in lifefloats and life buoy.
Action required: 705 - Other - as specified
Resolved 5 May 2005
Documentation › Certificates/Documents › Stability Letter
Issued 5 May 2005 Resolved
Post stability letter at operating station.
Action required: 705 - Other - as specified
Resolved 5 May 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 5 May 2005 Resolved
Show proof of annual extinguisher service.
Action required: 705 - Other - as specified
Resolved 5 May 2005
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 14 May 2004 Resolved
Eliminate excessive exhaust leakage from the port engine turbocharger. LEGACY COMPONENT DESC: Piping (exhaust)
Due 12 June 2004
Resolved 25 June 2004
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 14 May 2004 Resolved
Provide proper means for the header block blow-by discharge for both engines.
Due 12 June 2004
Resolved 25 June 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 May 2004 Resolved
Provide machinery guards for both shafts and both alternator v-belts. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 12 June 2004
Resolved 25 June 2004
Electrical
Issued 12 May 2004 Resolved
Provide proper splice connections for all electrical wiring in way of operating station circuit panel.
Due 12 June 2004
Resolved 14 May 2004
Resolution: Provided.
Electrical
Issued 12 May 2004 Resolved
Provide supports for electrical wiring for speaker system every 24" interval in way of #2 compartment.
Due 12 June 2004
Resolved 14 May 2004
Resolution: Provided.
Lifesaving
Issued 12 May 2004 Resolved
Stencil name of vessel onto all lifejackets.
Due 12 June 2004
Resolved 14 May 2004
Resolution: Stenciled.
Lifesaving
Issued 12 May 2004 Resolved
Stencil name of vessel onto all lifefloats.
Due 12 June 2004
Resolved 14 May 2004
Resolution: Stenciled.
Documentation › Logs/Records
Issued 12 May 2004 Resolved
Provide crew training log.
Due 12 June 2004
Resolved 14 May 2004
Resolution: Provided.
Accommodation/Occupational Safety › Medical/First Aid
Issued 12 May 2004 Resolved
Renew bottle of eyewash in 1st aid kit.
Due 12 June 2004
Resolved 14 May 2004
Resolution: Renewed.
Operations/Management › Drills/Instruction
Issued 12 May 2004 Resolved
Post emergency instruction list per 46CFR185.510.
Due 12 June 2004
Resolved 14 May 2004
Resolution: Posted.
Engineering
Issued 12 May 2004 Resolved
Label fuel shutoff valve locations.
Due 12 June 2004
Resolved 14 May 2004
Resolution: Labeled.
Lifesaving
Issued 12 May 2004 Resolved
Provide slats for lifeloats.
Due 12 June 2004
Resolved 14 May 2004
Resolution: Provided.
Navigation › Piloting/Steering › Marine Charts
Issued 24 June 2003 Resolved
Provide chart of Lake Tahoe.
Due 25 June 2003
Resolved 25 June 2003
Lifesaving › Buoyant Apparatus
Issued 24 June 2003 Resolved
Properly label lifefloat paddles with the vessel name.
Due 25 June 2003
Resolved 25 June 2003
Operations/Management › Drills/Instruction
Issued 29 May 2003 Resolved
Prior to carrying Passengers conduct man overboard drills in presence of a U.S. Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Due 31 July 2003
Resolved 24 June 2003
Electrical › Lighting (service)
Issued 23 August 2002 Resolved
Repair or replace stern light. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 28 September 2002
Resolved 31 October 2002
Lifesaving › Hand Flares
Issued 23 August 2002 Resolved
Replace 3 red hand/held flares prior to carrying passengers. LEGACY COMPONENT DESC: Marking
Condition: Unknown
Due 28 September 2002
Resolved 31 October 2002
Operations/Management › Drills/Instruction
Issued 23 August 2002 Resolved
Prior to carrying passengers conduct fire and man overboard drills in presence of a U.S. Coast Guard marine inspector.
Condition: Unknown
Due 28 September 2002
Resolved 31 October 2002
Construction/Loadline
Issued 2 November 2001 Resolved
Mark vessel hull with draft marks as required by 46 CFR 185.602, in numbersat least 4 inchs in height, prior to the compliance date.
Condition: Unknown
Due 2 November 2001
Resolved 2 November 2001
Engineering
Issued 2 November 2001 Resolved
Tightend all main engine mounting bolts prior to the compliance date.
Condition: Unknown
Due 2 November 2001
Resolved 2 November 2001
Construction/Loadline
Issued 2 November 2001 Resolved
Adjust main sea suction ball valves (2) to insure full closure prior to thecompliance date.
Condition: Unknown
Due 2 November 2001
Resolved 2 November 2001
Accommodation/Occupational Safety
Issued 2 November 2001 Resolved
Repair railing on port side aft prior to the compliance date.
Condition: Unknown
Due 2 November 2001
Resolved 2 November 2001
Lifesaving
Issued 26 July 2000 Resolved
PROVIDE PENNANTS FOR THREE (3) BUOYANT APPARATUS, INSTALLED AS PER 46 CFR 160.010-4 PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 3 August 2000
Resolved 28 August 2000
Electrical
Issued 26 July 2000 Resolved
PROVIDE A PORTABLEE EMERGENCY LIGHT (FLASHLIGHT) PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 29 July 2000
Resolved 28 August 2000
Unknown
Issued 19 May 1999 Resolved
MARK VESSEL NAME AND HAILING PORT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Construction/Loadline
Issued 13 November 1996 Resolved
PROVIDE SUITABLE MEANS OF PROTECTING THROUGH HULL PLASTIC FITTINGS FOR THE SPEED LOG AND DEPTH SOUNDER.
Condition: Unknown
Due 13 November 1996
Resolved 13 November 1996
Fire Fighting
Issued 5 June 1995 Resolved
PRIOR TO 20 JUNE 1995 PROVIDE TO THIS OFFICE PROOF OF HYDRO/SERVICING OF ALL ON BOARD PORTABLE FIRE EXTINGUISHERS AS PER NFPA REGULATIONS.
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Lifesaving
Issued 17 July 1991 Resolved
PROVIDE PLANS FOR REVIEW, AND INSTALL A DAVIT OR OTHER SUITABLE EQUIPMENT TO ASSIST IN THE REMOVAL OF A DISABLED PERSON FROM THE WATER. THE DAVIT MUST HAVE A MINIMUM SAFE WORKING LOAD CAPACITY OF 160 LBS. THIS ITEM SHALL BE COMPLETED PRIOR TO THE START OF THE 1992 OPERATING SEASON.
Condition: Unknown
Due 17 July 1991
Resolved 17 July 1991
Engineering
Issued 9 June 1987 Resolved
PROVIDE EXHAUST INSULATION FOR THE MAIN DIESEL ENGINE EXHAUSTS FROM THE TURBOCHARGER TO THE MUFFLER. THE COMPLETION OF THIS REQUIREMENT SHALL BE REPORTED TO [name withheld] LETTER.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987

Ownership record