Records from 1990 to 2003. Most recent: inspection, 30 October 2003.
Inspection history · 16
30 October 2003
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1939210
20 October 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1931967
27 December 2001
Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1474066
12 July 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 291890
21 April 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 277120
8 July 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 430484
29 January 1999
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 424840
2 February 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 412429
12 February 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 647163
10 February 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 400418
10 March 1994
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 365313
9 March 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 64907
13 August 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 504231
28 June 1993
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 450594
30 April 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 357901
8 August 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 338814
Electrical › Electrical Distribution System (emergency)
Issued 20 October 2003
Resolved
GROUND DETECTION ON EMERGENCY GENERATOR PANEL INOPERATIVE. THIRD PHASE LIGHT NOT FUNCTIONING DURING GROUND DETECTION TEST. MAKE REPAIR WITHIN 30 DAYS. LEGACY COMPONENT DESC: Ground Detection
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 30 October 2003
Resolution: cleared by MSO Tampa
Navigation
Issued 8 July 1999
Resolved
MAJOR VIBRATION IN SHIPS STEERING SYSTEM WHEN TURNING ON PUMPS IN HAND CONTROL MODE. THE WHOLE VESSEL VIBRATES VIOLENTLY._x001C_ _x001C_ SOLAS 60 REG I/11_x001C_
Condition: Unknown
Due 8 July 1999
Resolved 14 July 1999
Fire Fighting
Issued 29 January 1999
Resolved
Provide a pair of firemans boots on board for each firmans outfit that is on board the ship.
Condition: Unknown
Due 14 July 1999
Resolved 14 July 1999
Navigation
Issued 10 February 1997
Resolved
NOAA 11370, chart for the area transitted, was not onboard.
Condition: Unknown
Due 10 February 1997
Resolved 12 February 1997
Navigation
Issued 30 April 1993
Resolved
OLD GYRO REPEATERS WOULD NOT WORK WITH NEW GYRO SYSTEM
Condition: Unknown
Due 30 April 1993
Resolved 12 May 1993