Records from 2016 to 2026. Most recent: inspection, 6 May 2026.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2026
Resolved
Replace leaking fire hose on the main deck aft starboard side
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2026
Resolved 7 May 2026
Resolution: installed new hose, all sat
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 6 May 2026
Resolved
Replace guard on the fan on the Texas deck midship overhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2026
Resolved 20 May 2026
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 May 2026
Resolved
Reinstall all removed fire/smoke caulk in deck penetrations where new audio/ video wires were ran from the wheelhouse to Texas deck and in guide space aft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2026
Resolved 20 May 2026
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2026
Resolved
Find and repair exhaust leak on port main engine exhaust system
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2026
Resolved 20 May 2026
Resolution: all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2026
Resolved
Properly stow adult and children's life jackets. Adult life jackets were found in children's marked locations on the main deck aft starboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2026
Resolved 7 May 2026
Resolution: all, sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 May 2026
Resolved
Repair/ replace broken bilge high level alarm light on bridge for compartment #4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 20 May 2026
Resolution: all sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2026
Resolved
clean up and properly support all electrical wiring under the wheel house dash and remove dead end wire on the 02 deck port overhead junction box
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2026
Resolved 20 May 2026
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2026
Resolved
Properly mount fire extinguishers in the Texas deck fwd snack bar.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 20 May 2026
Resolution: all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2026
Resolved
Properly mark stowage locations of life jackets with size and number stored on aft Texas deck both sides
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 12 June 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 May 2025
Resolved
Prove proper operation of install alarm in bridge for port Main engine jacket water tank level
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 5 June 2025
Resolution: All sat
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 8 May 2025
Resolved
Replace broken light cover in Engine Room at the bottom of the ladder.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 5 June 2025
Resolution: All sat
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 8 May 2024
Resolved
Place high water alarm float for compartment #7 and fwd peak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 10 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 May 2023
Resolved
remark vessel’s name on all faded ring buoys
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 30 May 2023
Resolution: all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 May 2023
Resolved
Prove proper operation of life ring buoy light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 30 May 2023
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 May 2023
Resolved
Label all Exits on Texas deck and below the main deck to include arrows as needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 30 May 2023
Resolution: all sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2023
Resolved
Repair 220 Volt Outlet on Texas deck Fwd in galley
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 30 May 2023
Resolution: all sat
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 May 2023
Resolved
Prove proper operation of all emergency lights
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 3 July 2023
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 May 2022
Resolved
replace all combustible trash can with non-combustible trash can with no opens in the sides or bottom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 10 June 2022
Resolution: all sat
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 May 2022
Resolved
replace all expired items in the first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 10 June 2022
Resolution: all sat
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 6 May 2022
Resolved
Replace missing lagging on the port generator exhaust manifold.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 10 June 2022
Resolution: all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2022
Resolved
Repair/Replace 392 Adult Life jackets and 49 Children life jackets. Vessel is reduced to 538 Adult persons and 51 children until repaired / replaced
Action required: 705 - Other - as specified
Due 5 May 2022
Resolved 10 June 2022
Resolution: all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 May 2022
Resolved
Replace Expired life ring buoy light battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 18 May 2022
Resolution: all sat
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Certification, verification and control
Issued 11 May 2021
Resolved
Security plan must be locked in a secured location.
Action required: 10 - Deficiency Rectified
Due 11 May 2021
Resolved 11 May 2021
Resolution: Locked up security plan.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 May 2021
Resolved
Name of vessel must be legible on all life ring buoys.
Action required: 10 - Deficiency Rectified
Due 11 May 2021
Resolved 11 May 2021
Resolution: Remarked faded markings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2021
Resolved
Quantity of life jackets must marked in the stowage location.
Action required: 10 - Deficiency Rectified
Due 11 May 2021
Resolved 11 May 2021
Resolution: Labeled life jacket quantity.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2021
Resolved
Child life jackets must be physically separated from adult life jackets.
Action required: 10 - Deficiency Rectified
Due 11 May 2021
Resolved 11 May 2021
Resolution: Physically seperated child from adult life jackets.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 May 2021
Resolved
Structural fire protection on 2nd deck must be repaired.
Action required: 10 - Deficiency Rectified
Due 11 May 2021
Resolved 11 May 2021
Resolution: Repaired structural fire protection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2021
Resolved
Wiring on 2nd deck must be supported with approved hangers.
Action required: 10 - Deficiency Rectified
Due 11 May 2021
Resolved 11 May 2021
Resolution: Properly supported wiring.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2021
Resolved
Electrical outlet is missing the cover on the 1st deck galley.
Action required: 10 - Deficiency Rectified
Due 11 May 2021
Resolved 11 May 2021
Resolution: Installed missing outlet cover.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2021
Resolved
Battery boxes are missing covers in the engine room.
Action required: 10 - Deficiency Rectified
Due 11 May 2021
Resolved 11 May 2021
Resolution: Installed battery covers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2021
Resolved
Remove or properly insulate exposed wires above fuel shutoff in engine room.
Action required: 10 - Deficiency Rectified
Due 11 May 2021
Resolved 11 May 2021
Resolution: Insulated exposed low voltage wiring.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 May 2021
Resolved
The vessels COI must be posted.
Action required: 10 - Deficiency Rectified
Due 11 May 2021
Resolved 11 May 2021
Resolution: Posted COI.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 11 May 2021
Resolved
Must have senior deckhand IAW NVIC 1-91, training and designated in writing.
Action required: 10 - Deficiency Rectified
Due 11 May 2021
Resolved 11 May 2021
Resolution: Designated senior deckhand and training in writing IAW NVIC 1-91
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 11 May 2021
Resolved
Senior deckhand must have a TWIC card.
Action required: 10 - Deficiency Rectified
Due 11 May 2021
Resolved 11 May 2021
Resolution: Deckhand aquired TWIC.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 May 2021
Resolved
Provide firefighting servicing certs, to include HALON system.
Action required: 10 - Deficiency Rectified
Due 11 May 2021
Resolved 11 May 2021
Resolution: Provided Fire servicing reports.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 8 June 2017
Resolved
Background checks required by 49CFR40.25 not being conducted with background check form provided by DOT. This form is used to document the employers actions to comly with this requirement and the employees acknowledgnment of the requirement to answer the question of previous drug test history. Employr must complete and employee sign a background check form for each safety sensitive employee.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 7 July 2017
Resolution: employer must submit to this office a completed background check form for each new employee who performs a DOT safety sensitive function
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 8 June 2017
Resolved
Employer requiring DOT pre-employment tesing for non DOT covered employees and including them in random testing.
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 7 July 2017
Resolution: Employer must determine which employees meet the defenition of safety sensitive under DOT/USCG rules and submit the revised list to this office. All other employees must be removed from DOT testing
Operations/Management › Drug and Alcohol Testing › Testing, Reasonable Cause
Issued 8 June 2017
Resolved
Employer Reasonable Cause testing program and crew training to this policy exist but are insufficient.
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 7 July 2017
Resolution: Review/update program to identify which positions require training to recognize abuse/use of intoxicants, actions they take and who is authorized to require a reasonable cause test. Must include check list of observed behaviors.
Lifesaving › Lifebuoys › Serviceable
Issued 10 May 2016
Resolved
Remove chain on stbd bridge wing light to nylon lanyard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2016
Resolution: Chain removed, nylon lanyard installed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 May 2016
Resolved
Add "III" to port bridgewing life ring.
Due 19 May 2016
Resolved 11 May 2016
Resolution: "III" added.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 May 2016
Resolved
Re-stencil port 02 deck aft life ring.
Due 19 May 2016
Resolved 11 May 2016
Resolution: Life ring re-stenciled.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 May 2016
Resolved
Properly secure CO2 bottle for drink dispenser in bilge storage area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2016
Resolution: Bottle strapped to rack.
Construction/Loadline › Penetrations › Gasket
Issued 10 May 2016
Resolved
Reseal port and satarboard fathometer caps in space 8.
Due 19 May 2016
Resolved 19 May 2016
Resolution: Received pictures showing caps secured.
Electrical › Electric Supply System (service) › Cable
Issued 10 May 2016
Resolved
Properly cap dead end wires in space #1, stbd aft side.
Due 19 May 2016
Resolved 11 May 2016
Resolution: Dead end cables removed.