Records from 1987 to 2007. Most recent: operational control imposed, 23 October 2007.
Inspection history · 26
23 October 2007
Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3085594
13 October 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3079056
13 September 2007
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3057124
12 September 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3057472
29 November 2005
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2542338
29 March 2004
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2033580
26 March 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2032627
12 February 2002
In-Service Inspection · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1485925
5 March 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 287347
17 March 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 275852
19 August 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 431782
14 June 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 429700
1 September 1998
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 419958
23 February 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 400539
14 February 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 34837
11 December 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 385708
10 March 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 375941
16 December 1993
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 363095
26 April 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 357777
14 October 1992
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 353679
18 January 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 348291
23 April 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 343301
6 March 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 328822
11 January 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 320681
30 July 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 317556
12 March 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 314961
Lifesaving › Launching Appliances › Davit
Issued 23 October 2007
Resolved
Vessel's STBD and PORT Lifeboats gravity break are inoperable. The breaks do not stop the decent of the lifeboats when released.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2007
Resolution: Received Class report attesting to the proper operation and repairs of the vessel''s starboard and port lifeboats.
Electrical › Electric Generation Source (emergency) › Generator
Issued 23 October 2007
Resolved
Vessel unable to start emergency generator using a secondary source of energy.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2007
Resolution: Vessel received new batteries for the secondary means of start for the emergency generator.
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 23 October 2007
Resolved
The rudder angular indicator is 4 degrees off when compared to bridge rudder angular indicator.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2007
Resolution: Vessel fixed rudder angular indicator to 01 degrees difference compared to the bridges rudder angular indicator. While PSCO''s were on board.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 23 October 2007
Resolved
Vessel does not have tank capacity for intended voyage, vessel must discharge all oily water and sewage from bilges, bilge water tank and aft peak tank.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2007
Resolution: Received receipt of discharge from mobile facility attesting to the proper removal of the sewage/water mixture from the bilges and overflow tanks.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 23 October 2007
Resolved
The vessels lifeboats have not been maneuvered in the water during an abandon ship drill within the last 3 months.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2007
Resolution: Received class report attesting to the satisfactory port side lifeboat drill. Received class permission to proceed to anchorage and conduct starboard side drill on or before 25NOV2007.
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 13 October 2007
Resolved
Vessel's 2 of 3 generators are inoperable and as such the vessel cannot operate its main propulsion system and/or the equipment and services required by SOLAS 74 amended, CH. II-I, REG 40.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2007
Resolution: Vessel submitted Class report attesting to the satisfactory operation of the number 2 and 3 generator.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 29 March 2004
Resolved
The main engine cooling water overboard piping has two doubler patches installed before the overboard valve. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2004
Resolved 24 August 2007
Resolution: Cleared by Coast Guard Inspector. Issuing authority paperwork clearing DF was not available due to ship changing owner and operator.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 29 March 2004
Resolved
Both jacket water coolers for the generators have cement patches on the outlet isolation valves. LEGACY COMPONENT DESC: Jacket Water Coolers
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2004
Resolved 24 August 2007
Resolution: Cleared by Coast Guard Inspector. Issuing authority paperwork clearing DF was not available due to ship changing owner and operator.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 29 March 2004
Resolved
The high pressure piping sheilding for NO.1 generator fuel pumps NO.4, 5 & 6 are missing or need replacing.
LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2004
Resolved 24 August 2007
Resolution: Cleared by Coast Guard Inspector. Issuing authority paperwork clearing DF was not available due to ship changing owner and operator.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 29 March 2004
Resolved
The high pressure piping sheilding for NO.2 generator fuel pumps NO.2 & 4 are missing or need replacing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2004
Resolved 24 August 2007
Resolution: Cleared by Coast Guard Inspector. Issuing authority paperwork clearing DF was not available due to ship changing owner and operator.
Engineering › Fuel Oil Service System
Issued 12 February 2002
Resolved
fuel oil sounding tubes self-closing device, are not operational to prevent escape of fluids. SOLAS 74/78 Am I/11. Repair to the satisfaction of the safety construction cert issuing authority. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2002
Resolved 14 February 2002
Resolution: Self-closing devices repaired.
Construction/Loadline › Structures
Issued 12 February 2002
Resolved
Various fire dampers are not operational for fire detection. ICLL 66 REG 1/19. Repair to the satisfaction of the load line cert issuing authority. LEGACY COMPONENT DESC: Ventilators
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2002
Resolved 14 February 2002
Resolution: Fire dampers are repair.
Lifesaving
Issued 5 March 2001
Resolved
Perform fire drill to satisfaction of U.S. Coast Guard Inspectors.
Condition: Unknown
Due 5 March 2001
Resolved 8 March 2001
Accommodation/Occupational Safety
Issued 5 March 2001
Resolved
Provide fresh hot & cold running water to galley, hospital space, and crew accomodation.
Condition: Unknown
Due 5 March 2001
Resolved 8 March 2001
Lifesaving
Issued 5 March 2001
Resolved
Prove proper operation of port life boat braking and davit system.
Condition: Unknown
Due 5 March 2001
Resolved 8 March 2001
Fire Fighting
Issued 19 August 1999
Resolved
PERFORM FIRE DRILL DRILL TO THE SATIFACTION OF USCG MARINE INSPECTOR PRIOR TO 23AUG99.
Condition: Unknown
Due 23 August 1999
Resolved 20 August 1999
Documentation
Issued 14 June 1999
Resolved
Chief 0fficer does not have a Liberian license. (STCW 95 II/1)
Condition: Unknown
Due 20 August 1999
Resolved 20 August 1999
Documentation
Issued 14 June 1999
Resolved
First Assistant Engineer does not have a Liberian license. (STCW 95 III/1)
Condition: Unknown
Due 20 August 1999
Resolved 20 August 1999
Deck/Cargo
Issued 1 September 1998
Resolved
At next scheduled annual survey, but not later than 31Dec98, have class surveyor examine anchor chain link cross members. Make repairs if necessary to the satisfaction of the class surveyor._x001C_ SOLAS 97, Chapter I, Regulation 10
Condition: Unknown
Due 19 February 1999
Resolved 19 February 1999
Navigation
Issued 11 January 1988
Resolved
33CFR164.33(A)(1) CHART 11324 WAS NOT CORRECTED. CHARTS 11327, 11328 AND 11329 WERE MISSING.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Navigation
Issued 11 January 1988
Resolved
33CFR164.33(A)(2)(I) COAST PILOT VOLUME 5 WAS UNCORRECTED.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Documentation
Issued 11 January 1988
Resolved
33CFR155.720 VESSEL'S OIL TRANSFER PROCEDURES FOR BUNKER OPERATIONS WERE INCOMPLETE.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988