Records from 2005 to 2025. Most recent: inspection, 3 October 2025.
Inspection history · 16
3 October 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8245876
27 May 2025
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8145241
15 October 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8018973
30 July 2024
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7969846
28 March 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7886595
2 August 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7758821
5 June 2023
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7709350
25 April 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7675443
11 May 2022
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7448710
29 March 2022
Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7439777
4 January 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7375372
10 September 2021
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7311531
10 June 2021
COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7218878
19 May 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7200804
12 May 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7199370
28 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6253986
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 12 November 2025
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. The compass was not illuminated. Repair to the satisfaction of the MI. 46 CFR 184.402(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2025
Resolved 12 May 2026
Resolution: Compass wired to provide light
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 November 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. An intermittent hydraulic leak was observed on a tank. Identify the source of the leak and repair to the satisfaction of the MI.46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2025
Resolved 16 July 2026
Resolution: Operator repaired the leak.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 12 November 2025
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. A licensed master had an expired medical certificate. Obtain a valid medical certificate to the satisfaction of the MI. 46 CFR 10.301(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2025
Resolved 16 July 2026
Resolution: Medical certificates were checked at COI inspection- all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 November 2025
Resolved
Except as noted in 176.114 of this part, each vessel inspected and certified under the provisions of this subchapter must, when any passengers are aboard during the tenure of the certificate be in full compliance with the terms of the certificate. Vessel operated with passengers 5 times after missing annual inspection by over 3 months.
Action required: 10 - Deficiency Rectified
Resolved 12 November 2025
Resolution: Completed annual inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 October 2025
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. MI was made aware that vessel was passed 3 month window for annual inspection. Vessel must conduct an annual inspection.
46 CFR 176.500(b)(1)
701c
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2025
Resolution: Completed annual inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 May 2025
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. MI received notice that vessel was passed required drydock date. Vessel may not operate as a SPV until drydock exam is conducted.
46 CFR 176.600(c)(1)
701c
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2025
Resolved 2 June 2025
Resolution: Completed dry dock inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2024
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Failure to address deficiencies for life ring and high water level alarms in unmanned spaces
issued on 23Jul2024
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2024
Resolution: defs were addressed. see videos.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 July 2024
Resolved
A vessel must have one or more ring life buoys as follows: (2) A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter; The vessel’s ring buoy seal plug was missing which affects the serviceability of the buoy. Replace with correct plug.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2024
Resolution: See video attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 July 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. The visual alarms for the following spaces were inoperable: bow, cabin, and fish hold. Replace bulbs/fixtures visual alarms to align with regulation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2024
Resolution: see video attached.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 30 July 2024
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. The master on board with Merchant Mariner credentials was not part of the DAPI consortium for the vessel. Ensure that all employees are part of the DAPI program.
Action required: 10 - Deficiency Rectified
Resolved 30 July 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 May 2022
Resolved
Boundaries that separate machinery spaces from accommodation spaces must be lined with noncombustibles panels or insulation approved IAW 46 CFR 164.009. Vessels engine room and generator room hatch does not have insulation. Install insulation that meets 164.009
46 CFR 177.410(c)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 30 June 2022
Resolution: Received photo of insulation installed on hatch
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2022
Resolved
At each inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Vessel had hydraulic leak of batteries in generator space. Repair hydraulic leak.
46 CFR 176.830(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 25 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 May 2022
Resolved
An exposed hazard, such as gears or rotating machinery must be properly protected by a cover, guard, or rail. Vessels port starboard side main engine had exposed belt that needs to be covered.
46 CFR 177.960
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 25 April 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 May 2022
Resolved
Emergency fuel shut off valves must be marked clearly at least 1 inch high legible letters indicating purpose of the valve and direction of operation. Vessel emergency fuel shut off valves were not labeled.
46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2022
Resolved 25 April 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2022
Resolved
Vessel missed required due date for plan submittal of monitoring device required by 3/28/2022. Granted 30 day extension for plan submittal. Failure to meet deadline will result in another 835 issued for no passenger overnight accommodations. 46 CFR 185.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2022
Resolved 25 April 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2022
Resolved
Vessel was issued 30 day extension to meet required plan submittal for watch monitoring device(s) per new Fire Safety of Small Passenger Vessels Federal Register/Vol 86, No. 245, dated December 27, 2021. Vessel failed to submit required plans, therefore vessel is not authorized to use overnight accommodations for passengers until plans are received and approved by local OCMI. 46 CFR 185.410(b)
Action required: 705 - Other - as specified
Due 2 May 2022
Resolved 25 April 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 4 January 2022
Resolved
A hatch exposed to the weather must be watertight. Make the forward chain locker watertight. Vessel cannot carry passengers/cargo until this deficiency is corrected and cleared by the USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2022
Resolved 11 May 2022
Resolution: Repairs were made to make chain locker watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2021
Resolved
Install metal hangers for runs of hose and wire/cable greater than 24"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 10 September 2021
Resolution: Visited vessel to confirm.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 June 2021
Resolved
Seal with firestop thru bulkhead penetrations in engine room and aft bulkhead with lazarette.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 10 September 2021
Resolution: Visited vessel to confirm.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 June 2021
Resolved
Mark escape hatch on outside of hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 10 September 2021
Resolution: Visited vessel to confirm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2021
Resolved
Install blank covers on electrical panel in accomodations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 10 September 2021
Resolution: Visited vessel to confirm.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 June 2021
Resolved
Make forward chain locker watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 11 May 2022
Resolution: Attending vessel for annual exam. Proper repairs were made to FWD hatch to make weathertight.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 June 2021
Resolved
Provide automatic emergency lighting in accomodations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 10 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2021
Resolved
Waterlight battery expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 29 June 2021
Resolution: Received photo's of batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 June 2021
Resolved
Properly install IBA painter at weak link.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2021
Resolution: Corrected prior to the end of the inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2021
Resolved
Provide 03 fire buckets with proper lanyard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2021
Resolution: Corrected prior to the end of the inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2021
Resolved
Cover battery bank with suitable cover to protect against falling object.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 10 September 2021
Resolution: Visited vessel to confirm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2021
Resolved
Repair hydraulic leak falling on batteries in gen space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 10 September 2021
Resolution: Visited vessel to confirm.