← All vessels
CAROLINE
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southwest District (CGD-SW) · Other hulls named CAROLINE
CAROLINE is a 1987 passenger vessel (inspected). The Coast Guard has recorded 68 inspections since 1987, most recently in February 2025, along with 168 deficiencies — 1 with no resolution recorded —, 6 operational controls and 1 casualty investigation in 2023.
Records from 1987 to 2025. Most recent: inspection, 12 February 2025.
- Built
- 1987
- Last inspected
- 12 February 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 168 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2023
Identity
915541
WCY5169
278548
Flag
UNITED STATES
366752090
Maury page id
psix-278548
Inspections, by type
…with no type recorded3
Years with a record
34 calendar years (1987–2025)
The 68 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 15.8 ft × 7.6 ft
Registered tonnagegross 40 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMONTEREY, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 20 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Simplified, Gross Ton
32 - Simplified, Net Ton
32 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WCY5169MMSI 366752090 · active · compulsorily equipped · granted 25 April 2018, expires 1 July 2028
WTK7567MMSI not assigned · expired · compulsorily equipped · granted 10 October 1996, cancelled 17 February 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 68
12 February 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8069249
26 February 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7862018
29 January 2024
Drydock Exam · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7855811
26 January 2023
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7620623
23 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7612393
25 January 2022
Deficiency Check · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7383838
4 January 2022
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7375449
12 February 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7140139
20 March 2020
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6931105
20 March 2020
Simplified Stability Test · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6931559
17 January 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6891556
17 January 2020
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6891600
7 January 2019
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6600813
12 March 2018
Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6370260
5 March 2018
DAPI Audit · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6364345
7 February 2017
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6082022
3 February 2016
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5808705
11 January 2016
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5795031
4 March 2014
Examination of Repairs · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4809315
12 December 2011
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4206421
30 November 2010
Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3899065
15 December 2009
Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3651442
22 January 2009
Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3400496
7 January 2009
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3390445
17 November 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3358988
12 November 2008
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3358266
6 December 2005
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2547154
11 September 2005
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2489703
5 January 2005
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2270609
16 November 2004
Hull Examination · Plan Review "T" Boat
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2203177
4 November 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2203176
7 October 2003
Deficiency Check · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1963547
15 November 2002
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1705853
10 September 2002
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1671240
2 January 2002
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1474908
2 November 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1458011
22 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1076031
19 March 2001
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1373391
1 August 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1420370
9 August 1999
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 776640
26 April 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 790594
3 March 1999
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1432056
16 February 1999
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 804762
30 November 1998
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 807199
29 October 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 803330
10 June 1998
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 804226
8 September 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1368406
27 March 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1402412
20 August 1996
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1090074
11 December 1995
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1187682
18 October 1995
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 877462
17 February 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 850611
2 December 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1158064
20 October 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 871614
13 September 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1172024
20 August 1993
COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1463788
28 June 1993
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 845251
18 June 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 842633
15 September 1992
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1260310
18 September 1991
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 942367
7 February 1991
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1223101
10 July 1990
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 932617
1 November 1989
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1352942
18 January 1989
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1200959
4 November 1988
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1200827
8 September 1988
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1352860
9 February 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1329050
14 July 1987
Hull Examination · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1018223
Deficiency record · 168
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 February 2025
Resolved
The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway. Vessel was unable to get underway to test operation of the main propulsion machinery or man overboard and fire drills during annual inspection due to starboard engine inoperability. Conduct drills in presence of MI.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 12 February 2025
No resolution recorded
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter. Vessel does not have an operable SSB or SAT phone onboard. Vessel route restricted to within 20NM of land until required radio equipment is onboard.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 February 2025
Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side. Forward escape hatch was unable to be opened from the outside. Replace escape hatch.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 February 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 February 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Vessel is not equipped with a bilge pump visual indicator. Install visual indicator.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 February 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's anchor light is inop. Replace anchor light.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 February 2025
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel's name on lifering and lifefloat paddle is faded. Write vessel's name on life r
ring and paddle.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 12 February 2025
Resolved
A hatch exposed to the weather must be watertight. Engine room hatch cover seal is deteriorated. Replace and/or repair seal.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 March 2024
Resolved
A hatch exposed to the weather must be watertight. Port and starboard fuel shutoff valves are located on aft weatherdeck in a sealed bowl enclosure. Both enclosures are allowing deck water in which is seeping into the engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2024
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A second power pump is an acceptable alternative to a hand pump if it is supplied by a source of power independent of the first power bilge pump. Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Bilge pumping arrangements failed to actuate on initial and multiple subsequent attempts, bilge piping was found disconnected to lazarette and suction in engine room was clogged with debris.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 26 February 2024
Resolved
A hatch exposed to the weather must be watertight. The latching mechanism seal of the watertight hatch to the lazarette allows passage of water.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space. High level alarm panel not connected, high level alarms not providing audible or visual signals to bridge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 February 2024
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Port side tail shaft bolts are not tightened completely.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 February 2024
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Records of drills provided to Coast Guard were minimal and non descriptive. No drill records were available for significant time periods.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 February 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. There are unterminated wires in the forward compartment, as well as disconnected grounding cables for the anode in lazarette.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 February 2024
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. There is a pinhole opening in the watertight bulkhead between the engine room and the lazarette.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 February 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must have a means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Main engines could not actuate despite Fireboy override enabled. After troubleshooting discovered fireboy override connection was disconnected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2024
Resolved
A bilge pipe in a vessel of not more than 19.8 meters (65 feet) in length must be not less than 25 millimeters (1 inch) nominal pipe size. A bilge pipe in a vessel of more than 19.8 meters (65 feet) in length must be not less than 40 millimeters (1.5 inches) nominal pipe size. A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Engine room bilge suction filled with debris and missing strainer.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 26 February 2024
Resolved
Vessels subject to part III of title III of the Communications Act that operate in the waters described in § 80.901 must, at a minimum, be equipped as follows: (1) Vessels operated solely within 20 nautical miles of land must be equipped with a VHF–DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2), except that a VHF radiotelephone installation without DSC capability is permitted until one year after the Coast Guard notifies the Commission that shore-based sea area A1 coverage is established. Vessels in this category must not operate more than 20 nautical miles from land. Vessel’s VHF Radio is not equipped with MMSI or GPS positioning to meet DSC signaling requirements.
47 CFR 80.905(a)(1)
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 26 February 2024
Resolved
A vessel with installed toilet facilities must have a marine sanitation device that complies with 33 CFR part 159. No person may operate any vessel equipped with installed toilet facilities unless it is equipped with: An operable Type II or III device that has a label on it under § 159.16 or that is certified under § 159.12 or § 159.12a; or An operable Type I device that has a label on it under § 159.16 or that is certified under § 159.12, if the vessel is 19.7 meters (65 feet) or less in length. Vessels toilets are not connected to marine sanitation device.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 26 February 2024
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good
marine practice. Vessel has a detached, too short, unused shifter cable in engine space that is planned for removal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 February 2024
Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Port side wet exhaust is leaking minimal water and exhaust support structure on starboard side has deteriorated significantly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 February 2024
Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Starboard Racor filter is in extremely poor condition, as well as couplings leading to both starboard and port RACOR filters.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 26 February 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is
located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Electric solenoid valves must not be used, unless used in addition to the manual valve. Port and Starboard fuel lines are corroded around the fuel shut offs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 February 2024
Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. Life Float mounting brackets are cracked at the base and allowing water intrusion into deck house.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 February 2024
Resolved
For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. Forward 15-person life float has broken line attachments. Aft 15-person life float has broken attachments, separation, deterioration and discoloration of cover.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 January 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Electric solenoid valves must not be used, unless used in addition to the manual valve. Port fuel shutoff valve coming from main deck is connected via a reach rod and is showing signs of breaking. Replace reach rod.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 January 2023
Resolved
The lights prescribed in these Rules (Subpart C) shall have an intensity as specified in Annex I to these Rules (33 CFR part 84), so as to be visible at the following minimum ranges: (b) In a vessel of 12 meters or more in length: (i) A masthead light, 5 miles; except that where the length of the vesell is lass than 20 meters, 3 miles; (ii) A sidelight, 2 miles; (iii) A sternlight, 2 miles. Navigation light covers for the following lights found worn to the point where visibility is reduced: port sidelight, masthead, and stern. Replace covers for lights.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 January 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessel's first-aid kit contained multiple expired items. Discard expired items and provide a first-aid kit where all items are in serviceable condition.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 January 2023
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. NOAA EPIRB registration paperwork was not available for inspection. Provide copy of current NOAA EPIRB registration.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 January 2023
Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Where flexibility is necessary, a section of flexible metallic hose may be used. Nonmetallic hose may be used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, has a wall thickness sufficient to prevent collapsing or panting, and is double clamped where practicable. Port engine exhaust has slow leak near muffler and supports in engine room are wasted. STBD engine exhaust has extensive salt build-up in several locations indicating a leak is present. Repair both exhausts to ensure no leakage and properly supported.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 January 2023
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Several lights through engine room, heads, and sewage void did not have proper guards. Ensure all lights on vessel have proper guards.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 26 January 2023
Resolved
At each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition. Sewage void had multiple hoses connected to the sewage system that were no longer sufficiently connected with clamps. Ensure all sewage system connections are secure.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 26 January 2023
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. 3 of vessels port light covers are missing fasteners to provide proper weather-tight closure. Provide means to properly close covers.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 January 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, cause by or originating in electrical equipment, and electrical shock. FWD Bulkhead in engine room electrical junction box has exposed dead-end wires. Properly cap or remove unused or existing wires.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 January 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. FWD accommodation space closets contained flammable liquids, including solvents and paints. Remove all hazardous flammable liquids from vessel.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Risk evaluation, training and instruction to seafarers
Issued 26 January 2023
Resolved
For a vessel described by 46 CFR175.110(c), the training program in paragraph (a) of this section must address firefighting proficiency and must include all items referenced in this part. Provide required training and log into vessels training/drills logs. Federal Register/V.86 No. 245 46 CFR 185.420.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 26 January 2023
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. Deck rails must include a top rail with the minimum height required by this section, and lower courses or equivalent protection as required by this section. Vessel's rails have excessively loose wire rail courses. Tighten wire cable rail courses around entirety of vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 26 January 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: (g) Operational test of all overboard discharge and intake valves and watertight bulkhead pipe penetration valves. Marine Sanitation Device overboard discharge valve has vice grips installed in lieu of a valve handle. Unable to provide visual confirmation of open closed status. Provide proper valve handle to OVBD discharge valve.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 January 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Electric solenoid valves must not be used, unless used in addition to the manual valve. Housing around stbd fuel shutoff on main deck was disconnected from the deck and allowing water ingress into the engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 January 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: (h) Operational test of the means provided for pumping bilges. Pumping of fore-peak bilge space inoperable.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 January 2022
Resolved
Adult lift jackets must be provided for each person onboard a vessel. Vessel had 21 condemned kapok pfd's. Restricted to carrying 26 adult passengers for hire.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 January 2022
Resolved
Vessel must carry first aid kit approved under 160.041. First aid kit expired. Replace to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 January 2022
Resolved
At each inspection, bilges must be free from excessive oil in the bilges. Excessive oil under port main diesel engine. Determine cause of leak and clean oil from bilge.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 12 January 2022
Resolved
Vapor barriers must be provided in machinery spaces. Forward engine room bulkhead not vapor tight. Seal to satisfaction of marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 January 2022
Resolved
Electrical equipment installed must minimize accidental contact with electrical hazards. Dead end wires in sewage compartment. Remove or properly terminate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 January 2022
Resolved
Each electrical connection must be spliced IAW 46 CFR 183.340. Macerator pump wiring incorrectly spliced. Repair to satisfaction of MI.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 12 January 2022
Resolved
VHF Radio capable of DSC must have MMSI and Lat/Long input. MMSI and Lat/Long missing.
47CFR80
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 16 February 2021
Resolved
The float free link required by 180.130(a)(1) must be: Secured to the painter at one end and to the vessel on the other end. The life float lines need to be re-rigged so that all 4 life floats each connect to the painter.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 16 February 2021
Resolved
Each survival craft must be secured to the vessel by a painted with a float free link. The lines that connect the life floats to the painter and the lines that connect the lights to the life floats are deteriorated and need to be replaced.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 16 February 2021
Resolved
Each vessel that operates on the high seas must have on board an FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The EPIRB needs to be installed so that it can float free and activate.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 February 2021
Resolved
Each life float must be fitted with a lifeline, pendants, a painter, and a light. The lights attached to two of the Life Floats have expired batteries that need to be replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 February 2021
Resolved
Each ring life buoy on a vessel must be readily accessible and slower in a way that it can be rapidly cast loose. The mount for the ring buoy’s light is loose and needs to be repaired/tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2021
Resolved
A suitable metal type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Strainers must be leak free. There is a leak on the supply connection to the fuel filter that needs to be repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2021
Resolved
46 CFR 182.05-1(a) Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The shaft seal packing on the port engine is leaking water and needs to be repaired.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 March 2020
Resolved
All vessels must have navigation lights that are in compliance with the International and Inland Navigation Rules. The vessel's stern light is inoperable. The vessel is currently restricted to operating in daylight hours only. During periods of reduced visibility, the vessel is prohibited from operating.
46CFR183.420
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 25 February 2020
Resolved
Repairs or alterations to the machinery or equipment that affect the safety of the vessel without approval of the cognizant [name withheld] vessel repower, new engines and reduction gears are 600 pounds lighter requiring a new simplified stability test. Vessel required to maintain 300 pounds in bilge beneath port engine and 300 pounds in bilge beneath starboard engine and reduce maximum allowable passengers by 10 passengers until satisfactory simplified stability Test completion is witnessed by an attending qualified Marine Inspector.46 CFR 176.700 (a)
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 25 February 2020
Resolved
A propulsion engine control system, including pilothouse control must be designed so that a loss of power to the control systems does not result in an increase in shaft speed. Engine was repowered and power to ECM was not disconnected to prove increase in shaft speed does not happen when power is lost.46 CFR 184.620 (c)
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 10 February 2020
Resolved
Repairs or alterations to the machinery or equipment that affect the safety of the vessel without approval of the cognizant OCMI. Vessel propulsion machinery has been replaced. Stability test, machinery test, and sea trials must be completed prior to the carriage of passengers. 46 CFR 176.700 (c).
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 March 2019
Resolved
Rails on vessels engaged in excursion trips must be at least 39 1/2 inches high. Rail courses or equivalent must have bulwarks, chain link fencing or wire mesh with openings of not more than 4 inches or bar slats, rail courses or an equivalent spaced at intervals not more than 4 inches. Rails are not 39 1/2 inches and are gapped greater than 4 inches. Vessel is engaged in whale watching excursions.46 CFR 177.900
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 March 2019
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure, and personnel injury. Fuel filter outboard fittings have fuel soaked tape on them. Remove tape and repair leak. 46 CFR 182.01-5
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 March 2019
Resolved
All machinery shall be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Port Engine outboard exhaust non-metalic hose is crushed.
46 CFR 182.01-5
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 March 2019
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Three adult lifejackets were condemned and in need of replacement.46 CFR 180.71
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 January 2019
Resolved
Each item of survival craft equipment must be of good quality. 3 of 4 life lights were cracked and not servicable.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 March 2018
Resolved
07 PFDs found in poor, unserviceable condition & require replacement IAW 46 CFR 180.71.
Construction/Loadline › Penetrations › Gasket
Issued 5 March 2018
Resolved
04 holes identified in bulkhead between engine room & sewage compartment that require corrective actions to make vapor tight IAW 46 CFR 177.405(e).
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 7 February 2017
Resolved
Replace life jacket lights on PFDs. Vessel is restricted to carrying 21 pax. 46CFR180.75
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 7 February 2017
Resolved
Make collision bulkhead watertight. Needs more sealant on bunk room side of bulkhead. 46CFR171.085(h)
Engineering › Bilge Water Management System › Not Operational
Issued 7 February 2017
Resolved
Repair bilge high level alarm in aft lazarette. 46CFR182.115
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 December 2011
Resolved
Properly install machinery guards on port engines rotating belts. Cite: 46CFR 177.960. 12JAN2012
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 12 December 2011
Resolved
Properly secure or remove dead ended wire located outboard of the fire boy. Cite: 46CFR183.200. Due Date: 12JAN2012
Engineering › Bilge Water Management System › Strainer
Issued 12 December 2011
Resolved
Properly fit bilge suction strainer with 3x the pipe diameter for suction area in the cabin bunk bilge. Cite: 46CFR182.25-5(b). Due Date: 12JAN2012
Navigation › Piloting/Steering › Marine Charts
Issued 12 December 2011
Resolved
Provide updated chart with appropriate area for route specified on COI. Cite: 46CFR184.420. Due Date: 12JAN2012.
Navigation › Piloting/Steering › US Coast Pilot
Issued 12 December 2011
Resolved
Provide update Coast Pilot. Cite: 46CFR184.420. Due Date: 12JAN2012.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 December 2011
Resolved
Provide ammonia inhalants in first aid kit. Cite: 46CFR160.041(b). Due Date: 12JAN2012.
Communications › Alarms/Indicators › High Water Alarm
Issued 12 December 2011
Resolved
Label high level alarms located at the operating station. Cite: 46CFR182.530. Due Date: 12JAN2012.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 12 December 2011
Resolved
Prove proper services of the installed FIREBOY system IAW NFPA 10. Cite: 46CFR175.600. Due Date: 12JAN2012.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 12 December 2011
Resolved
Prove proper operation of Single Sideband radio to attending CG Marine Inspector. Cite: 47CFR80. Due Date: Prior to exceeding 20NM from shore.
Engineering › Bilge Water Management System › Piping
Issued 26 November 2010
Resolved
Reattach storage room bilge suction pipe to bilge line.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 November 2010
Resolved
Provide machinery guard to port MDE.
Deck/Cargo › Ballast › Valves
Issued 26 November 2010
Resolved
Prove proper operation of port raw water line intake.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 November 2010
Resolved
Properly dead end exposed wires in E/R.
Engineering › Fuel Oil Service System › Filter
Issued 26 November 2010
Resolved
Provide metallic plugs on RACOR fuel filters.
Engineering › Fuel Oil Service System › Valve
Issued 26 November 2010
Resolved
Renew port fuel shutoff valve.
Engineering › Steering Gear System › Rudder Stock
Issued 26 November 2010
Resolved
Properly install key stock on port rudder.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 26 November 2010
Resolved
Stencil adult lifejackets with vessel name in block letters.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 26 November 2010
Resolved
Provide lifejacket donning instructions for each specific lifejacket kept on board.
Lifesaving › Lifefloat › Serviceable
Issued 26 November 2010
Resolved
Replace 15 person lifefloat.
Lifesaving › Lifefloat › Painter
Issued 26 November 2010
Resolved
Renew all waterlight lanyards, lifelines, painter and pendants on lifefloats.
Lifesaving › Lifefloat › Serviceable
Issued 26 November 2010
Resolved
Repair damage on 10 person lifefloats in accordance with manufactures instructions.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 November 2010
Resolved
Provide current coast pilot, lightlist and chart.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 November 2010
Resolved
Provide EPIRB with valid registration prior to operating with passengers beyond 3 miles.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 November 2010
Resolved
Make wire passage to E/R from storage room airtight.
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009
Resolved
Company did not have result/exemptions for pre-employment testing prior for individuals working in a safety sensitive position, as required by 46 CFR 16.210.
Documentation › Logs/Records › Drug Test Records
Issued 15 December 2009
Resolved
Alcohol testing devices not onboard as required by 46 CFR 4.
Stability › Intact Righting Energy › General
Issued 7 January 2009
Resolved
Perform new Simplified Stability Test, after completion of the re-power for the vessel, and prior to carrying passenger for hire.
Construction/Loadline › Structures › End Bulkhead
Issued 12 November 2008
Resolved
Repair rotted frame for collision bulkhead hatch cover.
Electrical › Electric Supply System (service) › Battery Installation
Issued 12 October 2005
Resolved
Install battery cover to protect against falling objects in accordance with 46CFR 183.05-20.
Engineering › Steering Gear System › Hydraulic Hose
Issued 12 October 2005
Resolved
Replace hydraulic hose on STBD rudder with approved marine grade hose (SAE J1942) due to hose chaffing on transom.
Engineering › Bilge Water Management System › Not Operational
Issued 12 October 2005
Resolved
Prove proper operation of fixed bilge pump.
Electrical › Electric Supply System (service) › Cable
Issued 12 October 2005
Resolved
Replace chaffed/exposed wire inboard, above port MDE for amp meter.
Lifesaving › Lifefloat › Retroreflective Material
Issued 12 October 2005
Resolved
Replace all retro reflective tape on all four life floats. Existing retro reflective tape faded and worn.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 October 2005
Resolved
Replace retro reflective tape on life ring buoy. Retro reflective tape worn and faded.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 12 October 2005
Resolved
Install over current protection to red 12 gauge wire positive side of battery in engine room leading to lighting in fwd cabin.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 16 November 2004
Resolved
Properly install starboard sewage through hole fitting valve in engineroom.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 November 2004
Resolved
Properly secure 1 port and 1 starboard deck rail on the aft working deck.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 16 November 2004
Resolved
Renew fixed fire fighting system in the engineroom.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 16 November 2004
Resolved
Make both forward and aft bulkhead on the starboard side of the engineroom watertight.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 16 November 2004
Resolved
Remove oil in the engine room bilge.
Stability › Watertight Integrity › General
Issued 16 November 2004
Resolved
Renew starboard sewage vent tank gasket.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 4 November 2004
Resolved
Provide proof of current EPIRB registration IAW 46 CFR 180.64.
Engineering › Shafting/Propeller Arrangements › Thrust Shaft
Issued 4 November 2004
Resolved
Eliminate excessive water leakage from starboard shaft packing. Provide operational test of packing to the satisfaction of an attending MI.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 November 2004
Resolved
Provide covers for 3 overhead lights in way of engine room IAW 46 CFR 183.10.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 November 2004
Resolved
Renew anchor light IAW 46 CFR 183.420.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 4 November 2004
Resolved
Repair excessive cracks and damage to the surface of vessels 15-person life float IAW 46 CFR 180.175.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 4 November 2004
Resolved
Recharge B-1 portable fire extinguisher in way of pilothouse IAW 46 CFR 181.500.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 4 November 2004
Resolved
Provide of proof of current CPR qualification for 50% of vessel's crew IAW NVIC 1-91.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 4 November 2004
Resolved
Provide means to lock and secure 4 MSD overboard valves.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 4 November 2004
Resolved
Install weaklink for proper life float arrangement. COS.
Electrical › Electrical Distribution System (service) › Cable
Issued 4 November 2004
Resolved
Provide plans to install marine grade battery cable from starting batteries to port and starboard main engine starters to replace existing welding cable IAW 46 CFR 183.340.
Stability › Watertight Integrity › General
Issued 4 November 2004
Resolved
Make forward engine room bulkhead and forward accommodation space compartment bulkhead watertight in way of wire and flexible hose penetrations on port and starboard side IAW 46 CFR 179.320.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 November 2004
Resolved
Remove former name of vessel from life ring.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 4 November 2004
Resolved
Install securing device on centerline engine room hatch cover IAW 46 CFR 179.360.
Navigation › Collision/Grounding Avoidance › Radar
Issued 4 November 2004
Resolved
Prove proper operation of marine radar. Vessel's route restricted lake, bays, and sounds till corrected IAW 46 CFR 184.404.
Lifesaving › Visual Distress Signals (General) › Condition
Issued 4 November 2004
Resolved
Renew waterlight for 12 person life float. COS.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 4 November 2004
Resolved
Renew retro reflective tape on 1 adult and 2 child life jackets IAW 46 CFR 185.604. COS.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 4 November 2004
Resolved
Renew 2 waterlight batteries for 2 adult life jackets IAW 46 CFR 180.75. COS.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 4 November 2004
Resolved
Provide updated Notice to Mariners. COS.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 4 November 2004
Resolved
Make EPIRB retaining line float-free IAW 46 CFR 180.64. COS.
Lifesaving › Liferaft Equipment › Paddle
Issued 7 October 2003
Resolved
Secure two oars to each lifefloat with a lanyard.
Engineering › Bilge Water Management System
Issued 7 October 2003
Resolved
Prove proper operation of the LED light for the engine room bilge alarm.
Lifesaving › Hand Flares › Storage
Issued 7 October 2003
Resolved
Provide watertight brightly colored container marked "Distress Signals" for flare storage.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 7 October 2003
Resolved
Renew gasket, provide securing chain and eye ring for engine hatch cover to make watertight and secured to vessel.
Lifesaving › Inflatable Liferafts › Weak Link
Issued 7 October 2003
Resolved
Secure lifefloat weak link to the vessel.
Operations/Management › Drug and Alcohol Testing
Issued 10 September 2002
Resolved
Provide proof of current enrollment of vesel in a Drug & Alcohol Testing Program and a list to prove master and crew are enrolled. Proof must be faxed no later than 11SEP02. LEGACY COMPONENT DESC: Proof of Enrollment
Engineering › Bilge Water Management System
Issued 10 September 2002
Resolved
Renew high bilge alarm panel at operating station, to indicate which high bilge alarm is activated. Label visual alarms IAW 46CFR182.530(a)
Navigation › Piloting/Steering
Issued 10 September 2002
Resolved
Provide current copies of Coast Pilot and Light List. LEGACY COMPONENT DESC: US Coast Pilot
Communications › Radio Communications
Issued 10 September 2002
Resolved
Renew battery and NOAA registration for EPIRB, prior to operation more than 3 miles from shore, IAW 46CFR180.64. LEGACY COMPONENT DESC: EPIRB
Engineering › Bilge Water Management System
Issued 10 September 2002
Resolved
Install metallic shutoff valves on both sides (or one side w/ reach rod) of PVC pipe penetrating bulkheads forward and aft of the engine room, IAW 46CFR182.40-1(2)(ii) (Old T) LEGACY COMPONENT DESC: Piping
Lifesaving › Buoyant Apparatus
Issued 10 September 2002
Resolved
Renew damaged 15 person life floats (bottom- aft & forward) LEGACY COMPONENT DESC: Lifefloats
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 10 September 2002
Resolved
Repair engine shutdown system on fixed firefighting system.
New COI will not be issued until the engines shut down properly.
Fire Fighting
Issued 2 November 2001
Resolved
Prior to carriage of passangers, provide proof of annual servicing on B-II fire extinguisher in Forward Cabin.
Lifesaving
Issued 2 November 2001
Resolved
Route limited to not more than three nautical miles from shore until EPIRB hydrostatic release has been renewed and verified by CG Marine Inspector.
Lifesaving
Issued 2 November 2001
Resolved
Provide two additional marker lights (one for each life float) IAW 46CFR 180.175.
Navigation
Issued 1 August 2000
Resolved
PROVIDE A PROPER LIGHT FOR THE MAGNETIC COMPASS IAW 46 CFR 184.402(d). VSL IS RESTRICTED TO DAYLIGHT OPERATIONS UNTIL ITEM IS CLEARED BY AN ATTENDING MARINE INSPECTOR.
Engineering
Issued 1 August 2000
Resolved
PROVIDE PROPER MACHINERY GUARDS FOR PORT AND STBD MAIN ENGINES IAW 46 CFR 177.960.
Accommodation/Occupational Safety
Issued 1 August 2000
Resolved
REPLACE BROKEN WINDOW STARBOARD SIDE AFT IN PILOT HOUSE.
Lifesaving
Issued 29 October 1998
Resolved
MOUNT LIFEJACKET PLACARD
Navigation
Issued 29 October 1998
Resolved
UPDATE COMPASS DEVIATION CARD
Fire Fighting
Issued 29 October 1998
Resolved
SERVICE EXTINGUISHERS
Engineering
Issued 29 October 1998
Resolved
REPLACE FLAME SCREENS ON FUEL VENTS
Navigation
Issued 18 October 1995
Resolved
PROVIDE A CURRENT COPY OF THE NAVIGATIONAL RULES OF THE ROAD.
Electrical
Issued 18 October 1995
Resolved
PROPERLY DEAD END ABANDONED WIRING IN ENGINE ROOM.
Engineering
Issued 20 October 1994
Resolved
PROVIDE ENGINE GUARD FOR PULLEY ON FWD END OF STBD MDE (CLEARED CG-835 [CASE: MI94039544; 10/20/94] TO RE-INSTALL ENGINE GUARDS FOR BOTH MDE'S - MAIN GUARDS WERE INSTALLED).
Navigation
Issued 13 September 1994
Resolved
REPAIR VESSEL'S HORN. PROVIDE HANDHELD AIR HORN PRIOR TO CARRYING PASSENGERS.
Engineering
Issued 13 September 1994
Resolved
RE-INSTALL ENGINE GUARDS, BOTH MDE'S.
Lifesaving
Issued 20 August 1993
Resolved
REPAIR CRACKS IN LIFE FLOAT COATING AND REPAIR NET AT BOTTOM OF NETTING.
Lifesaving
Issued 20 August 1993
Resolved
PROVIDE 3 NEW ORANGE SMOKES AND 6 NEW RED FLARES. VESSEL RESTRICTED FROM CARRYING PASSENGERS UNTIL CLEARED.
Deck/Cargo
Issued 28 June 1993
Resolved
PROVIDE A MINIMUM OF 76 FEET OF ADDITIONAL ANCHOR LINE (MIN. 1/2") OR ANCHOR CHAIN (MIN. 3/8").
Navigation
Issued 28 June 1993
Resolved
DRILL AND PIN OR DOUBLE NUT THRU-BOLT CONNECTING PIN TO RUDDER LINKAGE PORTAND STBD.
Navigation
Issued 28 June 1993
Resolved
REPAIR HYDRAULIC FLUID LEAK TO PORT RUDDER ACTUATING RAM.
Construction/Loadline
Issued 28 June 1993
Resolved
ADD A CAPTIVE DEVICE TO CENTERLINE ENGINE ROOM HATCH TO PREVENT LOSS IN A SEAWAY.
Navigation
Issued 8 September 1988
Resolved
REPAIR OR REPLACE STBD RUNNING LIGHT AND PROVE OPERATION. VESSEL IS LIMITED TO DAYTIME OPERATIONS UNTIL THIS ITEM IS CLEARED.
Accommodation/Occupational Safety
Issued 8 September 1988
Resolved
REPAIR BROKEN WINDOW ON STBD SIDE OF MAIN CABIN.
Engineering
Issued 8 September 1988
Resolved
INSTALL GUARDS AROUND ALL BELTS ON FWD END OF BOTH MAIN ENGINES.
Construction/Loadline
Issued 8 September 1988
Resolved
ATTACH SUITABLE KEEPERS TO HATCH COVERS FOR ENGINE ROOM AND LAZARETTE.
Navigation
Issued 14 July 1987
Resolved
SWING MAGNETIC COMPASS AND PROVIDE A CURRENT DEVIATION TABLE PRIOR TO CARRYING PASSENGERS FOR HIRE.
Navigation
Issued 14 July 1987
Resolved
PROVIDE NAUTICAL CHARTS FOR WATERS OF OPERATION AND OTHER PUBLICATIONS AS PER 46 CFR 185.20-35 PRIOR TO CARRYING PASSENGERS FOR HIRE.
Casualty record · 1
31 December 2023Routine · role: Involved in a Marine Casualty · activity 7865803
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.