Records from 1987 to 2009. Most recent: operational control imposed, 28 July 2009.
Inspection history · 15
22 July 2009
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3542352
4 May 2004
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2058898
25 April 2004
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2052285
25 June 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1826564
16 February 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 286862
10 November 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 505054
26 May 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 516204
17 March 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 349436
30 December 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 347942
10 October 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 671244
24 September 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 534189
3 January 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 334555
7 December 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 334134
20 April 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 315554
25 March 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 315065
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 24 July 2009
Resolved
24 volt electrical system for controls and alarms is inoperable. This system serves the bridge controls for main engine and steering, fire detection system and quick acting valves for oil distribution system. System failed during port call. Will be fixed prior to departure to the satisfaction of the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2009
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 24 July 2009
Resolved
Saftey valves on Economizer appear to be inoperable due to missing and stuck actuating pin.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2009
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 24 July 2009
No resolution recorded
Vessel does not have an operational depth sounding device. Shall be fixed to the satisfaction of the Coast Guard.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 24 July 2009
Resolved
Aft port diesel generator has oil soaked lagging around fuel supply and fuel return. There is also buildup of oil under thhe generator. This condition creates a fire hazard and shall be fixed to the satisfaction of the Coast Guard
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2009
Electrical › Electric Supply System (service) › Cable
Issued 24 July 2009
Resolved
Numerous exposed wiring in engine room including electrical temperature sensors on main engine, open control panel near boiler, missing switch covers on control panels and unsecured wiring near engine control room. These deficiencies shall be fixed to satisfaction of the RO.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2009
Engineering › Sea-water System (primary cooling) › Pump
Issued 24 July 2009
Resolved
The mechanical seal on the #2 sea water supply pump is leaking heavily and flooding the forward bilge. This shall be fixed to the satisfation of the RO.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2009
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 24 July 2009
Resolved
Collecting drains on main engine are clogged and do not allow for proper collection of leaking oil. This condition is a fire hazard and shall be fixed to satisfaction of the RO.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2009
Engineering › Steam Boiler (propulsion) › Superheater Tube
Issued 24 July 2009
Resolved
There are 2 steam leaks at the boiler in the steam distribution lines near the walkway. This condition is a saftey hazard and shall be fixed to the satisfaction of the RO.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 24 July 2009
Resolved
Numerous lights inoperable along the catwalk leading from the boiler to the exhaust stack. This shall be fixed to the satisfaction to the RO.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2009
Engineering › Steering Gear System › Follow-up Assembly
Issued 22 July 2009
Resolved
Means of Auxiliary steering control from remote and local positions are not functional. #2 steering pump must be repaired prior to departure to the satisfaction of class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2009
Lifesaving › Lifeboat › Carriage Requirement
Issued 22 July 2009
Resolved
Ship has flag dispensation to operate with inflatable life raft substitution of Port Lifeboat. Starboard lifeboat winch has been repaired, but crew must demonstrate launching/recovery capability and conduct load test to the satisfaction of class prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2009
Engineering › Shafting/Propeller Arrangements
Issued 25 April 2004
Resolved
Provided class report addressing the proper operations of the Vsl Propeller. LEGACY COMPONENT DESC: Propeller (controllable pitch)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 27 April 2004
Resolved 27 April 2004
Resolution: DNV provided report attesting to the vessel parameters being normal and and conditions for permanent repairs of the propeller have been imposed.
Engineering
Issued 7 December 1989
Resolved
THE BILGE MONITOR WAS INOPERABLE AND REMOVED FOR REPAIRS. REPLACEMENT PARTS WERE ON ORDER AT TIME OF BOARDING AND WERE EXPECTED TO BE RECEIVED ATNEXT U.S. PORT CALL. IAW 33CFR 155.370 33USC 1908(B)(1)
Condition: Unknown
Due 7 December 1989
Resolved 7 December 1989
Navigation
Issued 25 March 1987
Resolved
A VIO OF 33CFR164.30 IN THAT B.A. CHARTS 2563, 2603, AND 2604, USED BY THE VSL, WERE NOT CORRECTED, WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM CAPE HENLOPEN TO TIOGA MARINE TERMINAL.
Condition: Unknown
Due 25 September 1991
Resolved 25 September 1991
Navigation
Issued 25 March 1987
Resolved
A VIO OF 33CFR164.30 IN THAT THE STEERING GEAR OPERATING AND CHAGEOVER INSTRUCTIONS AND STEERING GEAR BLOCK DIAGRAM REQ BY 33CFR164.35(K) WERE NOTPERMANENTLY DISPLAYED ON THE BRIDGE OR STEERING GEAR COMPARTMENT.
Condition: Unknown
Due 25 September 1991
Resolved 25 September 1991
Documentation
Issued 25 March 1987
Resolved
A VIO OF 33CFR156.170 IN THAT THE EQUIP TEST AND INSPECTIONS REQ IAW 33CFR 156.170(F)(2) WERE NOT CONDUCTED BY THE VSL.
Condition: Unknown
Due 25 September 1991
Resolved 25 September 1991
Navigation
Issued 25 March 1987
Resolved
A VIO OF 33CFR164.30 IN THAT THE VSL DID NOT HAVE O/B U.S. CHART 12304 OR ITS FOREIGN EQUIV WHICH WERE REQ FOR THE VSL'S ROUTE FROM CAPE HENLOPEN TO ARNOLD PT.
Condition: Unknown
Due 25 September 1991
Resolved 25 September 1991