Records from 1987 to 2007. Most recent: operational control imposed, 16 February 2007.
Inspection history · 19
15 February 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2872801
15 February 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2872933
19 October 2006
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2803974
8 August 2006
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2739696
22 June 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2688938
18 June 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2684163
10 May 2006
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2646057
4 December 2005
Type not recorded
No type recorded · Vessel Traffic Service Houston-Galveston · USCG Heartland District (CGD-H) · Activity 2562565
19 July 2005
ISPS III Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2425551
14 July 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2426484
27 January 2005
NPV Safety Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2281580
11 December 2004
ISPS II Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2256476
10 December 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2257029
4 April 2004
Certificate of Compliance · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2035353
5 April 2003
MARPOL Annex I Examination · MARPOL Annex V Examination · Certificate of Compliance
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1764378
16 September 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 282072
16 September 2000
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 822515
3 April 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 315227
3 April 1987
Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1018890
Navigation › Piloting/Steering › Gyro Compass
Issued 15 February 2007
No resolution recorded
Received notification that the gyrocompass onboard is inoperable. Vessel must have a certified technician make repairs and fax a copy of the report to the USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Received satisfactory tech report that repairs have been made.
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 8 August 2006
Resolved
The vessels chief engineer does not posses a valid STCW endorsement from the vessels flag state (Malta). Chief engineer is to provide a valid STCW endorsement prior to returning to the U.S. after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 October 2006
Resolution: Current Chief Engineer has a Malta endorsed license.
Operations/Management › Ballast Water Managment › Submission of Report
Issued 19 July 2005
Resolved
Vessel failed to submit ballast water reporting form to NBIC. administration must provide vessel updated ballast water management ship specific plan in accordance with NVIC 07-04, change 1 prior to next U.S. port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 May 2006
Resolution: Received proper documentation from the vessel satisfying requirement.
Deck/Cargo
Issued 16 September 2000
Resolved
FOUR FLAME SCREENS ARE PAINTED OVER ON PRESSURE RELIEF VALVES. CORRECT TO SATISFACTION OF CLASS, PRIOR TO NEXT US PORT.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000
Electrical
Issued 16 September 2000
Resolved
EMERGENCY GENERATOR HAS NO MEANS FOR AUTOMATIC SHUT DOWN. CORRECT TO SATISFACTION OF CLASS, PRIOR TO NEXT US PORT OF CALL.
Condition: Unknown
Due 16 November 2000
Resolved 16 November 2000
Navigation
Issued 16 September 2000
Resolved
RUDDER ANGLE POSITION NOT ABLE TO BE READ IN STEERING GEAR ROOM. CORRECTEDON SCENE.
Condition: Unknown
Due 16 September 2000
Resolved 30 October 2000
Fire Fighting
Issued 16 September 2000
Resolved
CO2 BOTTLE DISCONNECTED FROM HOSE IN CO2 ROOM. CORRECT TO SATISFACTION OF CLASS, PRIOR TO NEXT US PORT.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000
Lifesaving
Issued 16 September 2000
Resolved
STARBOARD LIFEBOAT MISSING VESSEL MARKINGS AND RETRO REFLECTIVE TAPE. CORRECT TO THE SATISFACTION OF CLASS, PRIOR TO NEXT US PORT.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000
Deck/Cargo
Issued 16 September 2000
Resolved
BRACKETS MISSING FOR COW AND STEAM LINES. CORRECTED ON SCENE.
Condition: Unknown
Due 16 September 2000
Resolved 30 October 2000
Documentation
Issued 16 September 2000
Resolved
PORT LOADLINE IMPROPERLY MARKED. REPAINT TO MATCH LOADLINE CERTIFICATE, TOTHE SATISFACTION OF CLASS AND FAX REPORT TO USCG, PRIOR TO NEXT US PORT.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000