MAURY USCG vessel records Sign in
← All vessels

RUD

RUD is a 1987 passenger vessel (inspected). The Coast Guard has recorded 124 inspections since 1987, most recently in September 2025, along with 136 deficiencies and 1 casualty investigation in 2004.

Records from 1987 to 2025. Most recent: inspection, 17 September 2025.

Built
1987
Last inspected
17 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN8560
279240
Flag
UNITED STATES
368318730
Maury page id
psix-279240

Inspections, by type

…with no type recorded55
Years with a record 37 calendar years (1987–2025)
The 124 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 16.0 ft × 5.0 ft
Registered tonnagegross 24 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYNN STEEL BOAT · SOUTH BOSTON, MA, UNITED STATES · built 1987
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSALEM, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Gross Ton
19 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN8560MMSI 368318730 · active · compulsorily equipped · granted 7 June 2023, expires 7 June 2033
WBG9360MMSI 367178940 · cancelled · compulsorily equipped · granted 16 March 2017, cancelled 18 April 2023
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

XL 713B Freight Barge · MISLE 118202 · 23 January 2004 · activity 1991651

Inspection history · 124

17 September 2025 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8233124
20 June 2024 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7927054
10 April 2024 Plan Review "T" Boat
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7892932
25 March 2024 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7879054
26 September 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7796581
15 June 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7672385
22 March 2022 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7407046
27 October 2021 Deficiency Check · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7333449
18 June 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7228866
28 May 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6956782
28 January 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6897581
26 September 2019 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6808449
28 June 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6727307
12 June 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6711595
4 April 2018 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6385065
28 January 2018 Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 6344896
10 January 2018 Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 6337090
31 August 2017 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6255884
27 March 2017 Excursion Permit
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6112211
27 March 2017 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6112275
16 March 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6105942
21 September 2016 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6005868
24 May 2016 Industry Initiated Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5885574
6 April 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5847759
31 March 2016 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5844228
13 August 2015 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5226924
5 June 2014 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4881216
3 May 2014 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 4849959
2 May 2012 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 4322419
25 February 2012 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 4251217
2 February 2012 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 4237276
2 February 2012 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 4237278
29 January 2012 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 4233924
29 January 2012 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 4233925
5 January 2012 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 4219600
5 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4201954
24 August 2011 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4126763
9 August 2011 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4110579
25 July 2011 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 4094628
25 July 2011 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 4094640
24 February 2011 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 3952173
21 February 2011 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 3949553
1 February 2011 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3939461
23 January 2011 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3939411
21 January 2011 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3939355
13 January 2011 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3939383
7 January 2011 Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 3922986
7 January 2011 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3939264
5 January 2011 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3939244
4 January 2011 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3939178
21 December 2010 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3922903
16 December 2010 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3922883
7 December 2010 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 3905804
5 December 2010 Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 3904645
28 November 2010 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 3899734
7 November 2010 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 3886432
3 November 2010 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 3965249
30 October 2010 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 3881320
25 October 2010 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 3878830
24 October 2010 Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 3876878
18 October 2010 Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 3875035
10 October 2010 Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 3867361
27 September 2010 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3858266
27 September 2010 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 3864398
26 September 2010 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 3857831
28 March 2010 Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 3704315
23 March 2010 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 3701730
22 March 2010 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 3706980
11 March 2010 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 3693968
23 February 2010 Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 3684905
17 February 2010 Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 3681810
13 February 2010 Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 3679588
12 February 2010 Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 3679594
17 November 2008 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3364837
2 April 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3176271
13 June 2007 Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2960491
28 March 2007 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2897040
14 April 2006 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2633245
9 September 2005 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2488385
30 August 2005 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2479654
7 September 2004 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2188819
23 January 2004 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1991651
12 August 2003 Hull Examination · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1874098
5 June 2003 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1850003
2 April 2002 COI Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1495850
29 October 2001 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 212764
29 October 2001 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1480010
22 August 2001 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1470330
26 March 2001 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1389343
27 April 2000 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1395416
25 August 1999 Hull Examination · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1118264
5 April 1999 Deficiency Check · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 786701
15 April 1998 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 791202
7 April 1998 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1123292
17 September 1997 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1121121
10 April 1997 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1098741
26 April 1996 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1081922
11 April 1996 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1080898
7 December 1995 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 877224
18 April 1995 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 851719
14 April 1994 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1167988
9 December 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1160039
19 November 1993 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 845170
29 April 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 835376
29 April 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1147630
20 April 1993 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 831638
7 July 1992 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 957558
16 April 1992 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1264775
23 September 1991 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1311224
13 May 1991 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 901733
10 April 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 910335
7 June 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1218197
17 April 1990 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1221100
10 April 1990 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 909795
10 April 1990 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 924592
13 April 1989 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1039697
29 March 1989 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 887449
22 November 1988 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 897287
8 September 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1204883
4 August 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1033880
14 April 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1031089
7 April 1988 Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1341055
8 October 1987 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1320851
2 April 1987 COI Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1023339

Deficiency record · 136

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 September 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided… 02 adult and 05 child life jackets were found missing or unserviceable. Vessel limited to 08 passengers due to only 01 serviceable child life jacket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2025
Resolved 29 September 2025
Resolution: Lifejackets renewed and COI minimum available onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 September 2025 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life jackets were not clearly separated from adult life jackets.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025
Resolved 29 September 2025
Resolution: Divider placed to separtate child and adult lifejackets.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 September 2025 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel missing portable light at the access to the machinery space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025
Resolved 29 September 2025
Resolution: Additional flash-light added.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 September 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) [ISO 18813:2006(E)] or a kit with equivalent contents and instructions. First aid kit contained expired medication.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025
Resolved 29 September 2025
Resolution: New first aid kit onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 June 2024 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. MI observed 0 firebuckets on board at the time of inspection.
Action required: 10 - Deficiency Rectified
Resolved 20 June 2024
Resolution: Operator installed the required fire buckets on the vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Wastage found at various points of superstructure and wheelhouse. Crop and renew to good steel prior to drydock credit and prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2024
Resolved 28 May 2024
Resolution: Operator renewed the wasted areas of the wheelhouse and passed an NDT in the presence of the MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Wastage found in aft bulkhead deck above lazarette. Crop and renew to good steel prior to drydock credit and prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2024
Resolution: Operator renewed the wasted areas of the wheelhouse and passed an NDT in the presence of the MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. A 4" long by 2" deep inset was observed on the port bow, forward compartment. Crop and renew to good steel prior to drydock credit and prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2024
Resolution: Operator renewed the wasted areas of the wheelhouse and passed an NDT in the presence of the MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Wastage was found around the forward most deck hatch in the deck. Crop and renew to good steel prior to drydock credit and prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2024
Resolution: Operator renewed the wasted areas of the wheelhouse and passed an NDT in the presence of the MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 28 March 2024 Resolved
For items not covered by standards in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Gasket for hatch on weather deck that leads into main storage compartment under wheelhouse does not provide an adequate seal. Replace gasket to the satisfaction of the attending marine inspector prior to drydock credit and prior to carrying passengers. 46 CFR 176.25-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2024
Resolution: MI observed that the hatch has been adjusted and is now watertight
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 28 March 2024 Resolved
For items not covered by standards in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Main deck hatch for lazarette was removed at time of hull exam with plywood covering the hatch opening in deck. Hatch to be properly installed and in good working order to the satisfaction of the attending marine inspector prior to drydock credit and prior to carrying passengers. 46 CFR 176.25-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2024
Resolution: Operator reinstalled hatch
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 March 2024 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. Numerous spliced wire connections were observed throughout the entire inside of the vessel and on deck. Wires/cables to be properly replaced or protected to the satisfaction of the attending marine inspector prior to drydock credit and prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2024
Resolution: MI observed that operator has installed junction boxes where electrical connections have been made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 March 2024 Resolved
A vessel of at least 7.9 meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. O/O is installing a new fire pump that ties into existing bilge pump and piping system. Install and test bilge piping system to ensure all suction points are properly operating as required to the satisfaction of the attending marine inspector prior to drydock credit and prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2024
Resolution: MI observed that the bilge system has been reinstalled and tested satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 15 June 2023 Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull, shall be made without the knowledge and approval of the Officer in Charge, Marine Inspection. Operator temporarily installed with straps, a F/W tank of approximately 140 gal. in the lazarette for ballast, and removed the solid ballast of 2150 pounds of sand bags which were required per the vessel's stability letter from 29Jun1990. Develop and submit plan to OCMI for approval. 46 CFR 176.20-1 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2023
Resolved 22 June 2023
Resolution: MI observed original sandbag ballast was reinstalled in the lazarette and the water from the newly installed F/W tank was removed.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 June 2023 Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull, shall be made without the knowledge and approval of the Officer in Charge, Marine Inspection. Operator cut out and installed a new deck hatch over the fantail and lazaratte area, cutting a longitudinal deck frame. Alteration remains incomplete and is open to the weather. Complete install, weld hatch to deck to a weather-tight condition, completing install to the satisfaction of attending Marine Inspector. 46 CFR 176.20-1 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2023
Resolved 23 June 2023
Resolution: MI inspected the welds visually and then witnessed a satisfactory water test on the welds. Operator informed MI that the new hatch was replacing an already existing hatch that had started to leak.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 June 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to the provisions for a seaworthy hull. Gasket material on all (03) weather-tight hatches on weatherdeck found worn or missing. 46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2023
Resolved 14 July 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 June 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. High level alarm visual indicator for engine room found inoperable. 46 CFR 182.530 46 CFR 182.115 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2023
Resolved 14 July 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Found numerous dead-end wires, exposed wiring, and temporary electrical connections. Remove unused wiring, cover or place exposed wiring in electrical box or receptacle, and remove extension cords when not utilizing maintenance equipment. 46 CFR 176.830 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2023
Resolved 14 July 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 June 2023 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. All lifejackets have old vessel name or are new without new name of vessel affixed. 46 CFR 185.604 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2023
Resolved 14 July 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 June 2023 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Lifering has only two strips of reflective material. Place additional reflective material per the specification above in an "X" pattern. 46 CFR 185.604 (i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2023
Resolved 14 July 2023
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 June 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Charts found onboard from 2009. Replace with currently corrected charts of area of operation. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2023
Resolved 14 July 2023
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 June 2023 Resolved
Each vessel must be marked as required by part 67, subpart I, of this chapter. Name of vessel and port of registry required per the Certificate of Documentation found not permanently affixed. 46 CFR 185.602
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2023
Resolved 14 July 2023
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 June 2021 Resolved
Each vessel that operates beyond the high seas must have onboard a FCC type approved EPIRB installed to automatically float free and activate. The HRU for the EPIRB is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2021
Resolved 25 June 2021
Resolution: New HRU installed.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 18 June 2021 Resolved
Each survival craft must be stowed so that inflates automatically. The vessels IBA HRU is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2021
Resolved 25 June 2021
Resolution: New HRU installed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 June 2019 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts of large enough scale to make safe navigation possible. Vessel has out dated navigation charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2019
Resolved 2 July 2019
Resolution: Vessel has current charts
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 June 2019 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Vessel's child life jackets are not separated from the adult life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2019
Resolved 2 July 2019
Resolution: child life jackets separated from adult life jackets
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 4 April 2018 Resolved
EPIRB test required shall be logged or otherwise documented. Log not being maintained.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 April 2018
Resolution: Log started.
Engineering › Bilge Water Management System › Pump
Issued 28 March 2017 Resolved
Bilge pump inoperable. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2017
Resolution: Repaired pump. Operational test completed.
Engineering › Bilge Water Management System › Pump
Issued 28 March 2017 Resolved
Portable hand pump missing. Provide portable pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 April 2017
Resolved 30 March 2017
Resolution: Portable pump on board.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 28 March 2017 Resolved
Retro on lifejackets worn. Replace retro tape on lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2017
Resolved 30 March 2017
Resolution: Retro installed on lifejackets.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 28 March 2017 Resolved
Means of escape not labeled. Properly mark means of escape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2017
Resolved 30 March 2017
Resolution: Escape marked.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 16 March 2017 Resolved
THE VESSEL'S 25-PERSON IBA HAS BEEN REMOVED FOR ANNUAL SERVICING AND HAS BEEN REPLACED WITH A SIX-PERSON LIFE RAFT. THE TOTAL NUMBER OF PERSONS ALLOWED ON BOARD IS LIMITED TO SIX UNTIL THE 25-PERSON IBA HAS BEEN REINSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 April 2017
Resolved 12 April 2017
Resolution: Received servicing certificate and photos of satisfactory reinstallation.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 31 March 2016 Resolved
THE VESSEL'S 25-PERSON IBA HAS BEEN REMOVED FOR ANNUAL SERVICING. THE VESSEL'S ROUTE IS LIMITED TO LAKES, BAYS & SOUNDS NOT MORE THAN ONE NAUTICAL MILE FROM SHORE UNTIL THE IBA HAS BEEN RE-INSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 7 April 2016
Resolution: Rcvd phone call and photo of installed IBA
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 6 June 2014 Resolved
Vent cover does not fit. repair.
Action required: 705 - Other - as specified
Due 19 June 2014
Resolved 23 June 2014
Resolution: Repaired vent cover, tested with satisfactory results.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 June 2014 Resolved
alcohol test kits were not onboard, Provide new kits.
Action required: 705 - Other - as specified
Due 19 June 2014
Resolved 23 June 2014
Resolution: Provided 2 new, approved blood alcohol test kits.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 November 2008 Resolved
Conduct survey of electrical system and provide proposal for repair. Repairs shall be conducted IAW 46 CFR Part 183.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 December 2008
Resolved 2 December 2008
Resolution: All repairs completed sat.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 17 November 2008 Resolved
Repair or install new windows IAW 46 CFR Subpart J.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 December 2008
Resolved 2 December 2008
Resolution: NEW WINDOWS INSTALLED SAT.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 April 2008 Resolved
Lenses on several nav lights faded and cracked, replace lenses
Action required: 705 - Other - as specified
Due 4 April 2008
Resolved 9 May 2008
Resolution: Lenses cleaned
Communications › Radio Communications › EPIRB
Issued 2 April 2008 Resolved
EPIRB battery expired, registration expired. Replace unit and re-register
Action required: 705 - Other - as specified
Due 4 April 2008
Resolved 13 May 2008
Resolution: EPIRB battery renewed
Lifesaving › Lifefloat › Serviceable
Issued 2 April 2008 Resolved
Lifefloat not properly maintained, clean, repaint, repair as necessary, replace retro, restencil, replace all lines
Action required: 705 - Other - as specified
Due 4 April 2008
Resolved 12 May 2008
Resolution: LF repaired
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 2 April 2008 Resolved
No lifesaving equipment log book on-board. Establish and maintain said log
Action required: 705 - Other - as specified
Due 4 April 2008
Resolved 12 May 2008
Lifesaving › Lifebuoys › Serviceable
Issued 2 April 2008 Resolved
Lifering body line deteriorated, replace line.
Action required: 705 - Other - as specified
Due 4 April 2008
Resolved 13 May 2008
Resolution: RB replaced
Operations/Management › Drills/Instruction › Abandon Ship
Issued 2 April 2008 Resolved
No training log book on board- establish and maintain log book
Action required: 705 - Other - as specified
Due 4 April 2008
Resolved 13 May 2008
Resolution: log book established
Communications › Audible Communications › Bell
Issued 28 March 2007 Resolved
Provide bell as per NAV RULES
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2007
Resolved 11 April 2007
Resolution: Bell provided sat.
Lifesaving › Lifefloat › Markings
Issued 28 March 2007 Resolved
Make repairs/reseal coated surface and re-stencil as per 46CFR185.604(e)
Action required: 705 - Other - as specified
Due 10 April 2007
Resolved 11 April 2007
Resolution: Lifefloat repaired sat.
Stability › Watertight Integrity › General
Issued 28 March 2007 Resolved
Adjust dogs on fwd deck scuttle
Action required: 705 - Other - as specified
Due 10 April 2007
Resolved 11 April 2007
Resolution: Scuttle repaired sat.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 28 March 2007 Resolved
Repair shackle and connect to bulkhead
Action required: 705 - Other - as specified
Due 10 April 2007
Resolved 11 April 2007
Resolution: New shackle installed sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 28 March 2007 Resolved
Mount hanging light fixture above main engine.
Action required: 705 - Other - as specified
Due 10 April 2007
Resolved 11 April 2007
Resolution: Light fixture re-installed sat.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 28 March 2007 Resolved
Post Emergency Broadcast Instructions
Action required: 705 - Other - as specified
Due 10 April 2007
Resolved 11 April 2007
Resolution: Emergency broadcast placard provided sat.
Construction/Loadline › Penetrations › Bottom Plug Seat
Issued 14 April 2006 Resolved
Make plug watertight in rudder post housing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 21 April 2006
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 14 April 2006 Resolved
Provide one additional type I adult life jacket.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2006
Resolved 21 April 2006
Navigation › Piloting/Steering › Compass Deviation Table
Issued 14 April 2006 Resolved
Update deviation table for vessel's compass.
Condition: Unknown
Due 21 April 2006
Resolved 21 April 2006
Communications › Radio Communications › EPIRB
Issued 9 September 2005 Resolved
Provide proof of registration
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 September 2005
Resolved 12 September 2005
Resolution: Provided
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 September 2005 Resolved
Stencil proper qty on storage lockers
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 30 September 2005
Resolution: Done
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 9 September 2005 Resolved
Provide 3 new PFD's. Passengers reduced until completed.
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 30 September 2005
Resolution: Done
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 9 September 2005 Resolved
Renew clogged flame screen on fuel tank vent.
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 30 September 2005
Resolution: Done
Electrical › Electric Supply System (service) › Cable
Issued 9 September 2005 Resolved
Renew all broken (all) electrical stuffing tubes penetrating pilot house roof.
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 30 September 2005
Resolution: Done
Engineering › Steering Gear System › Yoke
Issued 9 September 2005 Resolved
Make permenant repairs to binding steering linkage at rudder arm.
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 30 September 2005
Resolution: Done
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 September 2005 Resolved
Install metalic plugs in open threaded stuffing tube couplings in engine room forward bulkhead.
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 30 September 2005
Resolution: Done
Construction/Loadline › Structures › Superstructure
Issued 9 September 2005 Resolved
Renew badly wasted brackets for mast base.
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 30 September 2005
Resolution: New brackets and mast installed.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 September 2004 Resolved
VESSEL LIMITED TO CARRYING 32 PASSENGERS UNTIL 33 ADULT LIFE PRESERVERS ARE PROVIDED.
Action required: 705 - Other - as specified
Due 21 September 2004
Resolved 26 October 2004
Resolution: VESSEL HAS A TOTAL OF 33 ADULT LIFE PRESERVERS.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 September 2004 Resolved
PROVIDE PROPER RING BUOY LIFE LINE
Action required: 705 - Other - as specified
Due 21 September 2004
Resolved 26 October 2004
Resolution: PROPER LIFE LINE INSTALLED
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 September 2004 Resolved
PROVE OPERABILITY OF WATER LIGHTS ON LIFE RING AND LIFE FLOAT
Action required: 705 - Other - as specified
Due 21 September 2004
Resolved 10 November 2004
Resolution: OP TEST SAT
Communications › Radio Communications › EPIRB
Issued 7 September 2004 Resolved
PROVE EPIRB REGISTRATION
Action required: 705 - Other - as specified
Due 21 September 2004
Resolved 26 October 2004
Resolution: REGISTRATION PROVIDED.
Lifesaving › Lifefloat › Serviceable
Issued 7 September 2004 Resolved
REPAIR PUNCTURES ON LIFE FLOAT.
Action required: 705 - Other - as specified
Due 21 September 2004
Resolved 26 October 2004
Resolution: LIFE FLOATS REPAIRED.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 7 September 2004 Resolved
PROPERLY TIGHTEN STUFFING BOX ON SHAFT.
Action required: 705 - Other - as specified
Due 21 September 2004
Resolved 26 October 2004
Resolution: SHAFT STUFFING BOX TIGHTENED
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 7 September 2004 Resolved
PROPERLY SERVICE BII EXTINGUISHERS IN E/R
Action required: 705 - Other - as specified
Due 21 September 2004
Resolved 26 October 2004
Resolution: EXTINGUISHERS SERVICED.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 September 2004 Resolved
REPLACE FIRST AID KIT
Action required: 705 - Other - as specified
Due 21 September 2004
Resolved 26 October 2004
Resolution: FIRST AID KIT REPLACED.
Communications › Audible Communications › Horn/Whistle
Issued 7 September 2004 Resolved
PROPERLY REPAIR SHIP'S HORN.
Action required: 705 - Other - as specified
Due 21 September 2004
Resolved 26 October 2004
Resolution: SHIP''S HORN REPAIRED.
Construction/Loadline › Structures › Deck Plating
Issued 7 September 2004 Resolved
PROPERLY REPAIR/CROP AND RENEW PORTSIDE AFT DAMAGED DECK PRIOR TO NEXT DRYDOCK.
Action required: 705 - Other - as specified
Due 31 August 2005
Resolved 30 August 2005
Engineering › Fuel Oil Service System › Hose
Issued 7 September 2004 Resolved
PROPERLY REPLACE FUEL SUPPLY HOSE OFF FUEL TANK.
Action required: 705 - Other - as specified
Due 21 September 2004
Resolved 26 October 2004
Resolution: FUEL HOSE REPLACED
Engineering › Steering Gear System › Hydraulic Hose
Issued 7 September 2004 Resolved
PROPERLY REPLACE HYDRAULIC HOSES OFF PISTON CYLINDER
Action required: 705 - Other - as specified
Due 21 September 2004
Resolved 26 October 2004
Resolution: HOSES REPLACED.
Engineering › Bilge Water Management System › Pump
Issued 7 September 2004 Resolved
PROVE PROPER OPERATION OF MDE BILGE PUMP FOR ALL SPACES
Action required: 705 - Other - as specified
Due 21 September 2004
Resolved 26 October 2004
Resolution: OPS TEST SAT
Fire Fighting › Ventilation Systems › Ducts
Issued 7 September 2004 Resolved
PROVIDE FIRE DAMPNERS FOR VENTILATION INTAKES FOR E/R STACK
Action required: 705 - Other - as specified
Due 21 September 2004
Resolved 26 October 2004
Resolution: DAMPNERS PROVIDED.
Construction/Loadline › Structures
Issued 12 August 2003 Resolved
Prove watertight integrity of forepeak and crew quarters watertight hatches. LEGACY COMPONENT DESC: Manhole
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2003
Resolved 19 September 2003
Resolution: [name withheld] examined hatches and witnessed satisfactory hose test.
Construction/Loadline › Hull
Issued 12 August 2003 Resolved
Crop and renew as original/wasted deck logitudinal frame in forepeak IWO starboard side hatch. LEGACY COMPONENT DESC: Longitudinal Frame
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2003
Resolved 19 September 2003
Resolution: [name withheld] examined satisfactory renewed frame.
Communications › Radio Communications
Issued 5 June 2003 Resolved
Provide radio operators permit for [name withheld] (Master).
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 12 August 2003
Resolution: Cleared because [name withheld] no longer works for the company.
Lifesaving
Issued 5 June 2003 Resolved
Install proper weak link on lifefloat.
Due 3 July 2003
Resolved 12 August 2003
Resolution: Examined satisfactory weak link.
Engineering › Bilge Water Management System
Issued 5 June 2003 Resolved
Replace flexible hose for forepeak bilge system with an approved metalic bilge system.
Action required: 705 - Other - as specified
Due 3 July 2003
Resolved 12 August 2003
Resolution: Examined and found satisfactory new metalic bilge piping.
Operations/Management › Drills/Instruction
Issued 5 June 2003 Resolved
Post emergency instruction list.
Action required: 705 - Other - as specified
Due 3 July 2003
Resolved 12 August 2003
Resolution: Examined and found satisfactory posted emergency instructions.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 2 April 2002 Resolved
Remove B I and B II portable extinguishers from bilge
Due 16 April 2002
Resolved 2 April 2002
Documentation › Logs/Records
Issued 22 March 2002 Resolved
Log drills in vessel logbook LEGACY COMPONENT DESC: Logbook (official)
Due 16 April 2002
Resolved 18 April 2002
Navigation › Piloting/Steering
Issued 22 March 2002 Resolved
Obtain 2002 Current Tables and Light List LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Due 16 April 2002
Resolved 18 April 2002
Lifesaving › Lifebuoys
Issued 22 March 2002 Resolved
Provide buoyant, dark colored, uv resistant lifeline for ring buoy LEGACY COMPONENT DESC: Buoyant Lifeline
Due 16 April 2002
Resolved 18 April 2002
Lifesaving › Lifebuoys
Issued 22 March 2002 Resolved
Provide buoyant, dark colored, uv resistant lanyard for lifering waterlight LEGACY COMPONENT DESC: Self-igniting Lights
Due 16 April 2002
Resolved 18 April 2002
Lifesaving › Buoyant Apparatus
Issued 22 March 2002 Resolved
Stencil lifefloat with vessel name
Due 16 April 2002
Resolved 18 April 2002
Lifesaving › Buoyant Apparatus
Issued 22 March 2002 Resolved
Provide buoyant, dark colored, uv resistant painter for life float
Due 16 April 2002
Resolved 18 April 2002
Lifesaving › Buoyant Apparatus
Issued 22 March 2002 Resolved
Provide 2 paddles, minimum 4' in length for lifefloat
Due 16 April 2002
Resolved 18 April 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 22 March 2002 Resolved
Provide approved 1st aid kit LEGACY COMPONENT DESC: Medicine Chest
Due 16 April 2002
Resolved 18 April 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 22 March 2002 Resolved
Hydro test bridge B-II portable extinguisher LEGACY COMPONENT DESC: Condition
Due 16 April 2002
Resolved 18 April 2002
Electrical › Electric Supply System (service)
Issued 22 March 2002 Resolved
Remove unused wiring from 12 volt system in E/R LEGACY COMPONENT DESC: Battery Conductor
Due 16 April 2002
Resolved 18 April 2002
Construction/Loadline
Issued 22 August 2001 Resolved
Install suitably sized bilge suction strainer in Forepeak.
Condition: Unknown
Due 23 August 2001
Resolved 5 October 2001
Construction/Loadline
Issued 27 April 2000 Resolved
MAKE EMERGENCY ESCAPE HATCH IN SECOND COMPARTMENT OPERABLE, WATERTIGHT AND PROVIDE A HANDLE TO ENABLE OPENING FROM THE INSIDE.
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Lifesaving
Issued 27 April 2000 Resolved
VESSEL LIMITED TO NOT MORE THAN THREE MILES FROM LAND UNTIL THE VESSEL'S EPIRB IS BACK ON BOARD WITH A NEW BATTERY AND PROPERLY MOUNTED.
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Construction/Loadline
Issued 27 April 2000 Resolved
MAKE WATERTIGHT HATCH FOR FOREPEAK OPERABLE AND WATERTIGHT.
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Engineering
Issued 25 August 1999 Resolved
RENEW LEAKING GASKET FOR THE INTEGRAL FUEL TANK MANHOLE COVER.
Condition: Unknown
Due 10 September 1999
Resolved 1 October 1999
Engineering
Issued 5 April 1999 Resolved
RENEW SUPPLY AND RETURN FUEL FLEXIBLE LINES TO THE MAIN ENGINE.
Condition: Unknown
Due 19 April 1999
Resolved 27 April 1999
Navigation
Issued 5 April 1999 Resolved
INVESTIGATE PLAY IN STEERING QUADRANT BOLT/BRACKET ARRANGEMENT.
Condition: Unknown
Due 19 April 1999
Resolved 27 April 1999
Navigation
Issued 5 April 1999 Resolved
SECURE PORT NAVIGATION RUNNING LIGHT COVER.
Condition: Unknown
Due 19 April 1999
Resolved 27 April 1999
Construction/Loadline
Issued 7 April 1998 Resolved
PROVE WATERTIGHT INTEGRITY OF HATCH FOR FORWARD HOLD (COMP #2) AND FOREPEAK.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Electrical
Issued 7 April 1998 Resolved
PROPERLY DEADEND OR CONNECT LOOSE WIRES UNDER STEERING CONSOLE.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Construction/Loadline
Issued 7 April 1998 Resolved
PROPERLY SECURE VENT COVERS ON HOUSE ROOF.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Lifesaving
Issued 7 April 1998 Resolved
PROPERLY STENCIL VESSEL NAME ON 3 NEW LIFEJACKETS.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Construction/Loadline
Issued 7 April 1998 Resolved
DOUBLECLAMP BILGE PIPING AS PER 46 CFR 182.410(D)(1)
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Navigation
Issued 7 April 1998 Resolved
REPLACE TWO MISSING BOLTS ON CASE ENCLOSURE TO SHAFT SEAL.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Electrical
Issued 7 April 1998 Resolved
PROPERLY CRIMP WIRE LEADS TO BILGE PUMP.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Lifesaving
Issued 11 April 1996 Resolved
REPLACE ONE CHILDS LIFE PRESERVER WITH HOLE IN IT._x001C_
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Electrical
Issued 11 April 1996 Resolved
REFASTEN ELECTRICAL CABLES IN ENGINE ROOM ABOVE MAIN ENGINE WHERE HANGING.
Condition: Unknown
Due 15 April 1996
Resolved 15 April 1996
Construction/Loadline
Issued 11 April 1996 Resolved
REPLACE SATARBOARD FORWARD WINDOW (CRACKED) WITH APPROVED MATERIAL.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Fire Fighting
Issued 11 April 1996 Resolved
MAKE PERMANENT REPAIR TO SALT WATER LEAKING FIRE/BILGE PIPE.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Construction/Loadline
Issued 11 April 1996 Resolved
REPLACE GASKET ON THE SECOND HATCH FROM THE BOW.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Lifesaving
Issued 18 April 1995 Resolved
REPLACED MISSING ADULT PFD NOTED DURING SECOND REINSPECTION
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Accommodation/Occupational Safety
Issued 14 April 1994 Resolved
REPLACE CRACKED GLASS IN CABIN DOOR.
Condition: Unknown
Due 17 April 1994
Resolved 26 April 1994
Engineering
Issued 19 November 1993 Resolved
IN ACCORDANCE WITH 46CFR182.20-40(b)(7), CAP OR PLUG THE PET COCK CLEANING VALVES ON THE BOTTOM OF BOTH FUEL STRAINERS NO LATER THAN 03DEC93.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Engineering
Issued 19 November 1993 Resolved
INSTALL A THREADED CAP OF LIKE MATERIAL ON THE FUEL TANK DRAIN LINE NO LATER THAN 26NOV93.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Electrical
Issued 19 November 1993 Resolved
REMOVE FROM VESSEL THE OLD UNUSED BATTERY IN THE ENGINE ROOM NO LATER THAN 26NOV93.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Accommodation/Occupational Safety
Issued 20 April 1993 Resolved
REPLACE BROKEN PILOT HOUSE WINDOW PORTSIDE AFT.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Construction/Loadline
Issued 20 April 1993 Resolved
PRIOR TO PLACING VESSEL IN OPERATION PROVIDE HAND PUMP CAPABLE OF PUMPING. MINIMUM 5-GPM WITH SUFFICIENT HOSE TO REACH BILGE/OVERBOARD.
Condition: Unknown
Due 20 May 1993
Resolved 29 April 1993
Lifesaving
Issued 20 April 1993 Resolved
THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Lifesaving
Issued 20 April 1993 Resolved
PRIOR TO CARRYING PASSENGERS THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Documentation
Issued 20 April 1993 Resolved
PRIOR TO CARRYING PASSENGERS PROVIDE COPY OF VALID FCC OPERATORS PERMIT.
Condition: Unknown
Due 20 May 1993
Resolved 29 April 1993
Fire Fighting
Issued 16 April 1992 Resolved
CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD FIRE AND ABANDON SHIP PRIOR TO CARRYING PASSENGERS. DRILLS TO BE CONDUCTED BY MASTER WITH ALL REQUIRED CREW PRESENT. A LETTER OR COPY OF LOGBOOK ENTRY DESCRIBING THE_x001C_ DETAILS OF THE DRILLS SHALL BE SUBMITTED TO [name withheld].
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Documentation
Issued 16 April 1992 Resolved
RENEW EXPIRED FCC RADIO STATION LICENSE AND SAFETY CERTIFICATE. UNTIL SUCHTIME AS LICENSE AND CERTIFICATE ARE RENEWED VESSEL OPERATION IS LIMITED TO NOT MORE THAN 1000 FEET FROM LAND.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Fire Fighting
Issued 10 April 1990 Resolved
REPAIR OR REPLACE BROKEN FIRE EXTINGUISHER BRACKET STBD SIDE IN ENGINE ROOM.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Lifesaving
Issued 10 April 1990 Resolved
PROVIDE AN ADDITIONAL 4 ADULT 1 CHILD LIFE PRESERVERS, UNTIL SUCH TIME TOTAL PERSONS ALLOWED IS REDUCED TO 29.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Engineering
Issued 10 April 1990 Resolved
REMOVE EXCESS OIL FROM BILGE IN ENGINE ROOM.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Lifesaving
Issued 10 April 1990 Resolved
CONDUCT EMERGENCY DRILLS WITH CREW IN PRESENCE OF CG MARINE INSPECTOR
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Electrical
Issued 10 April 1990 Resolved
REPLACE OR REPAIR AFT DECK LIGHT ON STACK.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Lifesaving
Issued 29 March 1989 Resolved
PROCURE ONE CHILD TYPE I PFD.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Documentation
Issued 29 March 1989 Resolved
ALL OPERATORS PRESENT FCC MARINE OPERATOR PERMIT.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Navigation
Issued 29 March 1989 Resolved
REPAIR ALL STEERING SYSTEM HYDRALIC LEAKS
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Navigation
Issued 7 April 1988 Resolved
REPAIR LEAKING PIPING IN HYDRAULIC STEERING SYSTEM UNDER BRIDGE.
Condition: Unknown
Due 7 April 1988
Resolved 7 April 1988
Electrical
Issued 2 April 1987 Resolved
PROVIDE COVERS OVER BATTERIES INSTALLED IN ENGINE ROOM
Condition: Unknown
Due 2 April 1987
Resolved 2 April 1987
Engineering
Issued 2 April 1987 Resolved
INSULATE OR SUITABLY GUARD THE EXHAUST PIPE
Condition: Unknown
Due 2 April 1987
Resolved 2 April 1987
Engineering
Issued 2 April 1987 Resolved
PROVIDE A GUARD OVER THE BELTS AT THE FORWARD END OF THE ENGINE
Condition: Unknown
Due 2 April 1987
Resolved 2 April 1987
Engineering
Issued 2 April 1987 Resolved
PROVIDE A GUARD OVER THE SHAFT IN THE ENGINE ROOM BETWEEN THE ENGINE TO WHERE THE SHAFT EXITS THE HULL
Condition: Unknown
Due 2 April 1987
Resolved 2 April 1987

Casualty record · 1

23 January 2004Routine · role: Involved in a Marine Casualty · at BELT RAILROAD BRIDGE · activity 1991651
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

EILEEN C (2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.