MAURY USCG vessel records Sign in
← All vessels

MONTE CARLO

MONTE CARLO is a 1987 tank ship. The Coast Guard has recorded 24 inspections since 1987, most recently in December 2008, along with 21 deficiencies and 4 operational controls.

Records from 1987 to 2008. Most recent: inspection, 6 December 2008.

Built
1987
Last inspected
6 December 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8420232 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
279294
Flag
SINGAPORE
—
Maury page id
psix-279294

Inspections, by type

…with no type recorded13
Years with a record 7 calendar years (1987–2008)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it16555 - Convention (Subpart B), Gross Ton
8843 - Convention (Subpart B), Net Ton
35400 - Dead Weight, Ton
42971 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAN DO II Commercial Fishing Vessel · MISLE 187830 · 5 April 2008 · activity 3188930

Inspection history · 24

6 December 2008 COC-CHEM Annual · ISPS II Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3375134
5 April 2008 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3188930
29 March 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3173433
18 March 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3166697
17 March 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3165811
13 December 2007 Deficiency Check · Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3114414
2 December 2007 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3105094
20 February 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2874374
19 February 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2874134
19 February 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2879802
8 February 2007 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2869155
21 January 2007 Ballast Water Examination · PII Safety Exam · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2859258
30 October 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2525778
28 October 2005 MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex II Examination · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2524231
26 October 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2522958
23 February 2000 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 274969
24 December 1995 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 386027
3 April 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 202085
3 April 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 376885
3 April 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 765725
3 April 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1146802
11 May 1989 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1340689
11 April 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 315319
11 April 1987 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1330401

Deficiency record · 21

Personnel › Certificates/Documents/Licenses › STCW Certificate, Master
Issued 6 December 2008 Resolved
PSCO found that the Master's Singapore endorsement expired June 2008, Flag to provide appropriate Documentation to USCG prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2008
Resolution: PSCOs verified via email onboard vessel masters flag state endorsement.
Operations/Management › Drills/Instruction › Fire
Issued 6 December 2008 Resolved
PSCO noted that vessel's crew was unable to conduct a satisfactory Fire Drill and Boat drill, due to crew familiarization with equipment and procedures. Vessel to conduct satisfactory Fire and Abandon ship drills, prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2008
Resolution: Vessel demonstrated proper drills to PSCOs.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 2 December 2007 Resolved
3S high level alarm, 1C, 2P, and 3P overfill (high high level) alarms not operating on deck (no audible or visual alarm). All others alarming properly. Prior to loading cargo in US all level alarms must operate properly to sat of USCG.
Action required: 705 - Other - as specified
Resolved 13 December 2007
Resolution: Satisfactorily tested 3S high level alarm, 1C, 2P, and 3P overfill (high high level) alarms in cargo control room and on deck (audible and visual alarms).
Fire Fighting › Structural - B Class Divisions › Doors
Issued 21 January 2007 Resolved
Fire door leading from Engine Room to the Steering Gear Space failed to close completly. Fix to the satisfaction of Flag Adminstration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2007
Resolution: Rcvd DNV class survey report. Fire door repaired and tested satisfactorily.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 21 January 2007 Resolved
Failed to demonstrate proper operation and proof of calibration for fixed gas detection. To the satisfaction of Flag Administration.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 February 2007
Resolved 8 February 2007
Resolution: Received class report from Det Norske Veritas satisfying requirement.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 February 2000 Resolved
Renew cable straps in ballast pump room that were cut.
Condition: Unknown
Due 23 March 2000
Resolved 28 October 2005
Resolution: Cable was renewed.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 23 February 2000 Resolved
Update fire control plan to reflect sprinkler piping in paint locker.
Condition: Unknown
Due 23 March 2000
Resolved 28 October 2005
Resolution: Fire control plan was updated and approved by class.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 23 February 2000 Resolved
Conduct foam analysis and provide results to USCG Marine Safety Office.
Condition: Unknown
Due 23 March 2000
Resolved 28 October 2005
Resolution: Provided foam analysis report.
Navigation
Issued 3 April 1995 Resolved
PERMANENTLY AFFIX LABEL TO ARPA AS PER 33 CFR 164.38 (d)(1). PROVIDE LOCAL_x001C_COAST GUARD WITH SATISFACTORY CLASS SOCIETY SURVEYOR'S REPORT.
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Navigation
Issued 3 April 1995 Resolved
PROVIDE ANTI-BACKING NUTS OR DEVICES ON STEERING GEAR TELEMOTOR ARM TO_x001C_ SATISFACTION OF CLASS SOCIETY. PROVIDE LOCAL COAST GUARD WITH SATISFACTORY_x001C_SURVEYOR'S REPORT. SOLAS CHAPTER II-1 REG 29.
Condition: Unknown
Due 3 July 1995
Resolved 12 April 1995
Deck/Cargo
Issued 3 April 1995 Resolved
RENEW MANUAL VALVE HANDLES ON #4P AND #4S AND #6P CENTER TANK P/V VALVES._x001C_ PROVIDE LOCAL COAST GUARD WITH SATISFACTORY CLASS SOCIETY SURVEYOR'S REPORT._x001C_ 44 CFR 153.350.
Condition: Unknown
Due 3 July 1995
Resolved 12 April 1995
Documentation
Issued 3 April 1995 Resolved
(ON FOAM TANK) MARK VALVES WITH CORROSPONDING #'S FROM INSTRUCTIONS ONLY._x001C_ REMOVE #'S ON VALVES THAT DO NOT RELATE TO SYSTEM INSTRUCTIONS. PROVIDE _x001C_ LOCAL COAST GUARD WITH SATISFACTORY CLASS SOCIETY SURVEYOR'S REPORT._x001C_ SOLAS CHAPTER II-2.
Condition: Unknown
Due 3 July 1995
Resolved 12 April 1995
Deck/Cargo
Issued 3 April 1995 Resolved
PRESS UP P/V VALVE #1C CARGO TANK PRIOR TO LOADING #1C CARGO TANK. PROVIDE_x001C_LOCAL COASTGUARD WITH SATISFACTORY CLASS SOCIETY SURVEYOR'S REPORT TO LOCALCOASTGUARD.
Condition: Unknown
Due 3 April 1995
Resolved 7 April 1995
Deck/Cargo
Issued 3 April 1995 Resolved
PRIOR TO USING INERT GAS SYSTEM FOR CARGO REQUIRED TO BE INERTED PROVIDE N2GAS OF KNOWN PURITY/CONCERTRATION AND CALIBRATE SYSTEM CONDUCT IGS TEST ASREQUIRED BY SOLAS II-2 REG 62, THE SATISFACTION OF CLASS SOCIETY. PROVIDE_x001C_ LOCAL COAST GUARD WITH SATISFACTION SURVEYOR'S REPORT.
Condition: Unknown
Due 3 July 1995
Resolved 12 April 1995
Documentation
Issued 3 April 1995 Resolved
PRIOR TO LOADING CARGOES IN THE PORT OF HOUSTON, PROVIDE LETTER TO COTP_x001C_ HOUSTON IN REFRENCE TO VESSEL RESPONCE PLAN FOR PERMISSION TO LOAD CARGOES.33 CFR 155 SUBPART "D".
Condition: Unknown
Due 3 April 1995
Resolved 11 April 1995
Deck/Cargo
Issued 3 April 1995 Resolved
PRIOR TO CONDUCTING CLOSED CARGO LOADING OPERATIONS, RENEW VALVE ON VCS/IGSDRAIN LINE ON AFT MAIN DECK. PROVIDE SATISFACTORY CLASS SOCIETY SURVEYOR'S_x001C_REPORT TO LOCAL COAST GUARD. 46 CFR 39
Condition: Unknown
Due 3 July 1995
Resolved 12 April 1995
Fire Fighting
Issued 3 April 1995 Resolved
PROFESSIONALLY SERVICE SCBA'S (SELF-CONTAINED-BREATHING-APPARATUS).
Condition: Unknown
Due 3 July 1995
Resolved 12 April 1995
Unknown
Issued 3 April 1995 Resolved
PROVIDE ONBOARD TOXIC VAPOR TUBES FOR DRAGER.(TOLUENE, STYRENE, AND XYLENE)46 CFR 153.526
Condition: Unknown
Due 5 April 1995
Resolved 12 April 1995
Documentation
Issued 3 April 1995 Resolved
UPDATE OIL TRANSFER PROCEDURES AS PER 33 CFR 155.750
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Deck/Cargo
Issued 3 April 1995 Resolved
DEMONSTRATE PROPER OPERATION OF INERT GAS SYSTEM WITH ASSOCIATED ALARMS ANDSHUTDOWN MECHANISMS PRIOR TO LOADING CARGOES THAT REQUIRE TO BE INERTED. PROVIDE CLASS SOCIETY SURVEYOR'S REPORT TO U.S. COAST GUARD._x001C_ SOLAS 74, CHAP II-2, R 62
Condition: Unknown
Due 25 December 1995
Resolved 25 December 1995
Documentation
Issued 3 April 1995 Resolved
PROVIDE ON BOARD 46 CFR PARTS 140 TO 155 AS PER 46 CFR 153.905.
Condition: Unknown
Due 5 April 1995
Resolved 12 April 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.