Records from 2016 to 2025. Most recent: inspection, 10 November 2025.
Inspection history · 13
10 November 2025
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8266767
28 August 2024
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7991780
8 August 2024
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7974780
7 July 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7734912
8 August 2022
Internal Structural Exam · Re-Inspection · Deficiency Check · Drydock Exam · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7528349
22 June 2021
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7232975
18 August 2020
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7032096
18 August 2020
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7144162
28 August 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6785211
2 October 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6543114
17 September 2018
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6540354
6 September 2017
COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6250203
14 September 2016
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5998670
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 August 2024
Resolved
Fireboy had not been serviced since 2022. Restricted from carrying pax until serviced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2024
Resolved 31 August 2024
Resolution: Serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 August 2024
Resolved
Vessels life ring beyond serviceable life.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2024
Resolved 31 August 2024
Resolution: Lifering replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 August 2024
Resolved
Waterlight was missing from the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2024
Resolved 31 August 2024
Resolution: Replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 August 2024
Resolved
Missing first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2024
Resolved 31 August 2024
Resolution: Replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 August 2024
Resolved
Missing horn
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2024
Resolved 31 August 2024
Resolution: Added
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 July 2023
Resolved
Bilge high level alarm inoperable due to loose wire and repaired on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 July 2023
Resolved 7 July 2023
Resolution: repaired
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 August 2022
Resolved
Prove proper operation of float light attached to life ring.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 August 2022
Resolved 7 September 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 June 2021
Resolved
Portable flashlight inop.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2021
Resolved 3 July 2021
Resolution: Vessel bought and installed new flashlights.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 June 2021
Resolved
Vessel first aid kit missing items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2021
Resolved 3 July 2021
Resolution: Vessel bought and installed new first aid kit.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure Gauge
Issued 14 September 2016
Resolved
Service 01 portable A-II fire extinguisher, gauge reads low.
Action required: 705 - Other - as specified
Due 21 September 2016
Resolved 15 September 2016
Resolution: Portable fire extinguisher was serviced to correct low pressure and place back into operational service.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 September 2016
Resolved
Replace water light on ring life buoy. Housing is cracked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2016
Resolved 15 September 2016
Resolution: New light was purchased along with new battery and reattached to ring life buoy.