MAURY USCG vessel records Sign in
← All vessels

PACIFIC HORIZON

PACIFIC HORIZON is a 1987 freight ship. The Coast Guard has recorded 32 inspections since 1987, most recently in August 2006, along with 9 deficiencies.

Records from 1987 to 2006. Most recent: inspection, 18 August 2006.

Built
1987
Last inspected
18 August 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8611776 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
279359
Flag
SOUTH KOREA
—
Maury page id
psix-279359

Inspections, by type

…with no type recorded23
Years with a record 18 calendar years (1987–2006)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it31488 - Regulatory (Subpart C or D), Gross Ton
31488 - Convention (Subpart B), Gross Ton
14754 - Regulatory (Subpart C or D), Net Ton
14754 - Convention (Subpart B), Net Ton
38891 - Dead Weight, Ton
46741 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 32

18 August 2006 PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2751219
5 June 2006 ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2670777
14 September 2004 PII Safety Exam · Ballast Water Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2195442
14 September 2004 ISPS II Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2195446
15 September 2003 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1905769
19 August 2002 Passenger/Freight Vessel Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1663471
19 March 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1494807
17 January 2002 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1479988
15 January 2002 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1477426
15 January 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1493234
5 July 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 291453
22 March 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 275805
3 January 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 436170
29 August 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 432088
29 December 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 423967
22 July 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 418628
6 January 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 412211
8 December 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 398284
13 September 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 395463
1 December 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 385317
30 March 1995 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1149887
28 July 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 368903
28 July 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 860879
30 June 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 359213
10 April 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 350110
29 May 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 344059
8 May 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 336878
23 March 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 329448
30 November 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 327010
10 April 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 322504
17 December 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 486451
11 April 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 315331

Deficiency record · 9

Fire Fighting › Firemans Outfit › Protective Clothing
Issued 18 August 2006 Resolved
Upon inspection of both firefighting suits it was noted that both pairs of gloves and one fire suit were severely tattered and damaged, compromising the fire protection capability.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 22 August 2006
Resolution: Received Class Report from Korean Register of Shipping satisfying the requirement.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 5 June 2006 Resolved
Make proper repairs to shipboard incinerator. Currently the unit iginitor is inoperable. Incinerator is not to be used until made to operate as designed to the satisfaction of the class. MARPOL V/5. Action 70a/70c.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 July 2006
Resolved 18 August 2006
Resolution: Deficiency was rectified to the satisfaction of the Coast Guard Marine Inspector.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 5 June 2006 Resolved
Renew rudder angle indicator for emergency steering at trick wheel (numbers cannot be read from control station) to the satisfaction of class. SOLAS 74 CH II-1/29. Action: 70a/70c.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 July 2006
Resolved 18 August 2006
Resolution: Deficiency was rectified to the satisfaction of the Coast Guard Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 June 2006 Resolved
Provide and install non-conductive matting at all decks in way of electrical panels in engine room. SOLAS 74 CH II-1/45. Action 70c.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 July 2006
Resolved 18 August 2006
Resolution: Deficiency was rectified to the satisfaction of the Coast Guard Marine Inspector.
Engineering › Steering Gear System › Power Unit
Issued 5 June 2006 Resolved
Address hydraulic leaks on steering gear to the satisfaction of class. SOLAS 74 CH II-2/29. Action 70a/70c.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 July 2006
Resolved 18 August 2006
Resolution: Deficiency was rectified to the satisfaction of the Coast Guard Marine Inspector.
Fire Fighting › Structural - Horizontal Zones › General
Issued 5 June 2006 Resolved
Make interior access door for engine room operate (door closure actuator) as designed. Apparatus currently disconnected. SOLAS 74 CH II-2/13. Action 70c.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 July 2006
Resolved 18 August 2006
Resolution: Deficiency was rectified to the satisfaction of the Coast Guard Marine Inspector.
Engineering › Sea-water System (primary cooling)
Issued 14 January 2002 Resolved
Main Engine Coolant System defect. Pin hole in salt water cooling tube allows lube oil to enter and permitting oily water discharge overboard. Prior to departure, control discharge of oil in way of lube oil system to prevent accidental discharge of additional oily waste. MARPOL Annex I, reg.9 LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2002
Resolved 17 January 2002
Resolution: According to class survey record faxed to MSO Puget Sound, leaking water tube was plugged with copper plug at both ends. After repair work, no leakage was found while pressurized at 4.7kg/cm2 oil. Other water tubes were examined and found to be intact.
Construction/Loadline
Issued 3 January 2000 Resolved
FOUND CEMENT SOFT PATCH ON BALLAST STRIPPING EDUCTOR (FWD CL ENG ROOM TO STBD OF BALLAST PUMP UNDER FLOOR BOARDS). MAKE PERMANENT REPAIR TO SATISFACTION OF CLASS PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Documentation
Issued 11 April 1987 Resolved
VESSEL TRANSITED THE COLUMBIA RIVER TO LONGVIEW, WA, WITHOUT HAVING CARGO INFORMATION CARDS FOR OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 11 April 1987
Resolved 11 April 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.