← All vessels
KAGHAN
Freight Ship · Bulk Carrier class · Built 1980s · USCG Heartland District (CGD-H) · Other hulls named KAGHAN
KAGHAN is a 1986 freight ship. The Coast Guard has recorded 28 inspections since 1987, most recently in February 2011, along with 28 deficiencies — 1 with no resolution recorded — and 6 operational controls.
Records from 1987 to 2011. Most recent: inspection, 24 February 2011.
- Built
- 1986
- Last inspected
- 24 February 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 28 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8513015 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FIM9
279360
Flag
PAKISTAN
—
Maury page id
psix-279360
Inspections, by type
…with no type recorded19
…past their stated due date1
Years with a record
18 calendar years (1987–2011)
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it36098 - Convention (Subpart B), Gross Ton
21824 - Convention (Subpart B), Net Ton
65716 - Dead Weight, Ton
76188 - Displacement, Ton
21824 - Convention (Subpart B), Net Ton
65716 - Dead Weight, Ton
76188 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 28
24 February 2011
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3939860
14 February 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3948543
11 February 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3943229
8 February 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3941597
24 October 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3876547
28 June 2005
Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2402995
22 March 2005
PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · ISPS III Exam · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2315843
11 July 2004
ISPS II Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2129166
10 June 2004
MTSA/ISPS Verification
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2095571
2 April 2004
Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2036302
4 January 2004
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1975182
10 October 2003
Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1923237
9 October 2003
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1925693
17 September 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1676463
15 June 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 290868
10 July 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 279603
30 March 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 276028
28 April 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 415272
23 October 1997
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 409011
16 March 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 388919
20 March 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 376013
25 October 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 361841
8 September 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 353046
6 November 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 515342
11 February 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 341898
18 January 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 334792
11 July 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 324340
16 April 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 315581
Deficiency record · 28
Deck/Cargo › Mooring/Anchoring › Winch
Issued 24 February 2011
No resolution recorded
1330 - Winches and capstans - After any survey of the ship has been completed, no changes shall be made in the structural arrangements, machinery, and equipment. Vessel reported an inoperable port anchor windlass and was granted a Letter of Deviation to transit the LMR. Class issued a condition to make repairs nlt May 2011. -SOLAS 74a I/11
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 24 February 2011
Resolved
1499 - Other (prop & aux machinery) - Each bunker line transfer pipe must be tested annually and not leak under static liquid pressure at least 1.5 times the max allowable working pressure. Vessel conducted annual test, however, air was used as a medium. - 33 CFR 156.170
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 22 March 2005
Resolved
The Ship does not have a Ballast Water Management plan on board developed specifically for the vessel. Provide a Ballast Water Management Plan on board that meets the requirements of the regulations.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 10 October 2003
Resolved
Perform hydrostatic test on the Halon fixed fire extinguishing system cylinders where the last test date was AUG 1985 and DEC 1984. Complete to the satisfaction of class to the Administration rules. SOLAS 74 amd 21
Documentation › Logs/Records › Oil Record Book
Issued 10 October 2003
Resolved
Commence making entries into the Oil Record Book as per the instructions found in Appendix III of Annex I of MARPOL 73/78 where the quantity of contents retained is missing under the C-12-2 and 3 entries.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 10 October 2003
Resolved
Update fire control plan where the stbd aft deck store has ben converted to a paint locker. SOLAS 74 I/11
Lifesaving › Launching Appliances › Falls
Issued 10 October 2003
Resolved
Investigate and repair as original the stbd lifeboat falls where the lifeboat was dropped during test. Ensure port side is also in satisfactory condition. Repair stbd lifeboat as original where fractured due to falls failure. SOLAS 74 I/11
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 October 2003
Resolved
Remove hold backs from A class fire doors in main stair tower, repair latch in doors between engine room and steering room and betweeen engine room and lower escape trunk. SOLAS 74 I/11
Construction/Loadline › Structures
Issued 10 October 2003
Resolved
Repair as original, where fractured, the main deck at forward stbd corner of number five cargo hold and aft port corner of number two cargo hold. ICLL 66. Received class report on 15-OCT-03. Condition of class issued, due Jan-04 LEGACY COMPONENT DESC: Deck Plating
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 October 2003
Resolved
Vessel issued Letter of Deviation for inoperable Radar.
Navigation › Piloting/Steering
Issued 17 September 2002
Resolved
Charts, Coast Pilot, & Light List required to navigate the COTP Philadelphia zone were not corrected up-to-date, as per NTM's for weeks 27-38. LEGACY COMPONENT DESC: Local Notices to Mariners
Lifesaving › Lifeboat Equipment
Issued 17 September 2002
Resolved
Radar Reflector's were missing from both the Port & Stbd lifeboats (a total of 02). LEGACY COMPONENT DESC: Radar Reflector
Construction/Loadline › Markings
Issued 17 September 2002
Resolved
The class society identifier is not permanitely affixed on either loadline, (vessel chg'd from BV to LR). LEGACY COMPONENT DESC: Load Line Mark
Construction/Loadline › Markings
Issued 17 September 2002
Resolved
The Loadline markings are not in a contrasting color to the hull. LEGACY COMPONENT DESC: Load Line Mark
Engineering › Generator (propulsion/auxiliary-electric)
Issued 17 September 2002
Resolved
A soft patch was observed on the aux. cooling water line for the ship's service generator located in the engine room. LEGACY COMPONENT DESC: Aux. cooling water line
Personnel › Certificates/Documents/Licenses
Issued 17 September 2002
Resolved
Ch. Officer does not hold a valid GMDSS license or endorsement as per STCW, ammend 95. The vessel's Safe Manning certificate requires all the navigational watchstanders to hold the same. LEGACY COMPONENT DESC: License, GMDSS Radio Operator
Lifesaving
Issued 30 March 2000
Resolved
PORT AND STARBOARD LIFEBOAT DEADMAN BRAKES NOT WORKING PROPERLY._x001C_ BRAKE NEEDS TO BE LUBRICATED AND MADE IN GOOD WORKING ORDER.
Documentation
Issued 28 April 1998
Resolved
SOPEP found not updated to new name of vessel, classification society, and flag state approval.
Navigation
Issued 23 October 1997
Resolved
Subject vessel arrived in the Port of Point Comfort with an inoperative ARPA. A Letter of Deviation was granted to the vessel to enter the Port. The joystick for targeting on the ARPA was malfunctioning, internal wres had been damaged on the voyage from Brazil.
Documentation
Issued 23 October 1997
Resolved
The subject vessel oil record book for machinery spaces did not have each action signed by the person in charge of the action. Instead each completepage was signed by the Chief engineer and the vessel master. This was not in accord with the directions for use in the manual.
Engineering
Issued 23 October 1997
Resolved
The data cards for oils transfered to the vessel were missing from the Oil Transfer Procedures. Spaces had been provided for these forms. The required information was not in the engine room. The oil information cardswere found posted in the passageway later in the boarding.
Engineering
Issued 20 March 1995
Resolved
Make permanent repairs to the boiler condenser salt water cooling piping inway of the two patches, (one on inlet, one on outlet), prior to departure, per SOLAS Chapter II-1 Reg 26.
Lifesaving
Issued 20 March 1995
Resolved
Clean entire engine room of excessive oil \ fuel that has overflowed from nearly all collection trays, prior to departure, per SOLAS Chapter II-2 Reg. 2.
Lifesaving
Issued 20 March 1995
Resolved
Make permanent repairs to the Rottmer releasing gear in both life boats. Test\launch both life boats to test gear. To be completed prior to departure. Per SOLAS Chapter III Reg 41(7.6).
Lifesaving
Issued 20 March 1995
Resolved
replace the missing drain plugs in the port life boat. Attach with a lanyard. To be completed prior to departure. Per SOLAS Chapter III Reg. 41(7.1).
Lifesaving
Issued 20 March 1995
Resolved
Replace the missing fire extinguisher in the stbd life boat, prior to departure, per SOLAS Chapter III Reg 41(8).
Lifesaving
Issued 20 March 1995
Resolved
Move all paint from the aft deck stores and steering gear room to the paintlocker, prior to departure, per SOLAS Chapter II-1 Reg 45(5.4).
Deck/Cargo
Issued 20 March 1995
Resolved
Permanently repair the leaking hydraulic rams, (fwd of #5 hold and aft of #1 hold), prior to departure, per 33 C.F.R. 151.10(b).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.