Records from 1987 to 2001. Most recent: inspection, 18 April 2001.
Inspection history · 38
18 April 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1064272
3 April 2001
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412278
15 April 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 47459
12 April 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1049217
9 February 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 60255
4 March 1999
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1423137
1 June 1998
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1127092
10 February 1998
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1463377
13 March 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446523
21 January 1997
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1416425
28 May 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1084656
28 March 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1409479
11 April 1995
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 874727
17 March 1995
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1455249
8 February 1994
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1162088
15 December 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 849396
27 October 1993
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1144955
12 May 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 833535
5 May 1993
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1151611
14 April 1993
Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1143835
14 April 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1151885
25 March 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 169623
12 June 1992
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1259430
3 June 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 949756
15 April 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1268005
30 September 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 955676
4 September 1991
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1309625
18 July 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 941599
13 March 1991
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 917106
7 March 1990
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1212772
16 February 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 902844
16 January 1990
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1232132
30 May 1989
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1208015
2 June 1988
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 898599
25 May 1988
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1206995
12 May 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1038751
5 April 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1313967
18 March 1987
Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1014265
Construction/Loadline
Issued 18 April 2001
Resolved
REMOVE ALL OIL AND DEBRIS FROM ALL BILGES AS REQUIRED BY 46 CFR 155.450
Condition: Unknown
Due 18 May 2001
Resolved 12 June 2001
Lifesaving
Issued 10 February 1998
Resolved
CONDUCT A SATISFACTORY FIRE AND MANOVERBOARD DRILL IN THE PRESENCE ON THE ATTENDING COAST GUARD INSPECTOR IN ACCORDANCE WITH 46 CFR 176.808 (g) AND COAST GUARD NVIC 1-91.
Condition: Unknown
Due 30 June 1998
Resolved 27 June 1998
Fire Fighting
Issued 13 March 1997
Resolved
INSTALL INDIVIDUAL SMOKE/FIRE DETECTIONDEVICES WITH UL-217 APPROVAL AS REQUIRED BY 46 CFR 181.450
Condition: Unknown
Due 13 April 1997
Resolved 4 August 1997
Construction/Loadline
Issued 21 January 1997
Resolved
PROVIDE DRAFT MARK READINGS WHICH ARE CONTRASTING TO THE VESSEL'S HULL COLOR IAW 46 CFR 185.602(C)(1).
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Construction/Loadline
Issued 21 January 1997
Resolved
PROPERLY RUN ALL CABLES THROUGH THE WATERTIGHT BULKHEAD LOCATED IN THE FUELTANK COMPARTMENT IAW 46 CFR 179.212.
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Construction/Loadline
Issued 21 January 1997
Resolved
RENEW/REPAIR THE WATERTIGHT HATCHES ON THE MAIN DECK. ENSURE ALL HATCHES ARE CAPABLE OF PROVIDING A WATERTIGHT SEAL IAW 46 CFR 179.360.
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Accommodation/Occupational Safety
Issued 21 January 1997
Resolved
PROVIDE MEANS FOR THE FORWARD EMERGENCY ESCAPE HATCH TO BE OPENED FROM BOTHSIDES AND REMOVE THE LOCKING MECHANISM FROM WITHIN THE VESSEL IAW 46 CFR 177.500(H).
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Fire Fighting
Issued 28 March 1996
Resolved
PROVIDE ONE 1.5" FIRE HOSE.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Lifesaving
Issued 28 March 1996
Resolved
RESTENCIL LIFE FLOAT WITH VESSEL NAME AND CAPACITY.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Fire Fighting
Issued 17 March 1995
Resolved
REPLACE BOTH FIRE HOSES.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Fire Fighting
Issued 17 March 1995
Resolved
PROVIDE PORTABLE FIRE EXTINGUISHERS WITH INSPECTION TAGS.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Navigation
Issued 17 March 1995
Resolved
REPAIR AND DEMOSTRATE OPERATION OF SIGNALLING HORN.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Fire Fighting
Issued 17 March 1995
Resolved
STENCIL NAME OF VESSEL ON FIRE AXE.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Electrical
Issued 17 March 1995
Resolved
INSTALL METAL WIRE CLAMPS AT INTERVALS OF 18" ON ALL OVERHEAD WIRE RUNS IN ENGINE ROOM.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Construction/Loadline
Issued 27 October 1993
Resolved
REPAIR CRACKS BOTH PORT/STBD SIDE TRANSOM FREEING PORTS AT DECK OVERBOARD DRAINS.
Condition: Unknown
Due 27 October 1993
Resolved 27 October 1993
Electrical
Issued 14 April 1993
Resolved
INSTALL PERMANENTLY MOUNTED APPROVED WIRING TO NEWLY INSTALLED ENGINE ROOM VENTILATION FANS.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Lifesaving
Issued 14 April 1993
Resolved
ATTACH SEA PAINTER TO THE BODY OF LIFE FLOAT WITH A WELL DONE SPLICE.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Engineering
Issued 14 April 1993
Resolved
REPAIR/RENEW STARBOARD MAIN DIESEL ENGINE TACH AND PORT MAIN DIESEL ENGINE CLUTCH OIL PRESSURE GAGE.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Lifesaving
Issued 14 April 1993
Resolved
INSTALL RETRO REFLECTIVE MATERIAL TO ONE ADULT LIFE PRESERVER.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Electrical
Issued 14 April 1993
Resolved
RELAMP GENERATOR SWITCHBOARD AVAILABILITY LIGHTS.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Engineering
Issued 14 April 1993
Resolved
REPAIR/RENEW WATER TEMPERATURE AND ENGINE OIL PRESSURE GAGE TO STBD GENERATOR PRIME MOVER.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Accommodation/Occupational Safety
Issued 14 April 1993
Resolved
INSTALL REMOTE SHUTDOWN TO NEWLY INSTALLED POWER VENTILATION TO ENGINE ROOM.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Navigation
Issued 14 April 1993
Resolved
INSTALL COTTER PIN TO PORT RUDDER POST RETAINING NUT IN STEERING COMPT.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Lifesaving
Issued 30 September 1991
Resolved
PROVIDE NEW BATTERY FOR EPIRB. PRESENT EPIRB BATTERY EXPIRES MAY 92.
Condition: Unknown
Due 30 September 1991
Resolved 30 September 1991
Fire Fighting
Issued 30 September 1991
Resolved
PROVIDE ADAPTER FOR SECOND FIRE HOSE AND HYDRO FIRE HOSE. _x001C_
Condition: Unknown
Due 30 September 1991
Resolved 30 September 1991
Accommodation/Occupational Safety
Issued 30 September 1991
Resolved
REPLACE BROKEN WINDOW GLASS IN WEATHERTIGHT DOOR LEADING TO SALON SPACE.
Condition: Unknown
Due 30 September 1991
Resolved 30 September 1991
Electrical
Issued 30 September 1991
Resolved
PROVE PROPER OPERATION OF STARBOARD GENERATOR._x001C_
Condition: Unknown
Due 30 September 1991
Resolved 30 September 1991
Accommodation/Occupational Safety
Issued 18 July 1991
Resolved
REMOVE TINT FILM FROM SIDE PILOTHOUSE WINDOWS._x001C_
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Deck/Cargo
Issued 18 July 1991
Resolved
RELOCATE A/C COOLING RAW WATER PUMP OUT OF BILGE IN ENGINE ROOM TO COMPLY WITH 46 CFR 183.10-5(C). ORIGINALLY ISSUED 13MAR91. CLEARED IN ERROR, REISSUED 25JUL91.
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Electrical
Issued 13 March 1991
Resolved
REPAIR OR REPLACE VOLT METER ON GENERATOR SWITCHBOARD_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Electrical
Issued 13 March 1991
Resolved
RELOCATE A/C COOLING RAW WATER PUMP OUT OF BILGE IN ENGINE ROOM TO COMPLY WITH 46 CFR 183.10-5(C)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Electrical
Issued 13 March 1991
Resolved
REPAIR OR REPLACE GROUND DETECTION SYSTEM ON SWITCHBOARD.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Unknown
Issued 16 February 1990
Resolved
STENCIL VESSEL NAME ON ONE(1) NEW APFD.
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Unknown
Issued 16 February 1990
Resolved
PROVE PROPER OPERATION OF BELT DRIVEN FIRE PUMP IAW 46CFR 181.10(C). 50GPM @ 60PSI @ PUMP PRESSURE GAUGE.
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Unknown
Issued 16 February 1990
Resolved
PROVE PROPER OPERATION OF BELT DRIVEN PUMP IN ALL COMPARTMENTS.
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Unknown
Issued 16 February 1990
Resolved
PROVIDE PROPER BRACKETS FOR AND MOUNT TWO(2) RING BUOYS IN ACCESSIBLE LOCATIONS.
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Unknown
Issued 30 May 1989
Resolved
PROVIDE PROPER SPANNER WRENCH FOR FIREHYDRANTS.
Condition: Unknown
Due 30 May 1989
Resolved 30 May 1989
Unknown
Issued 30 May 1989
Resolved
MOUNT FIRE AXE IN PILOT HOUSE.
Condition: Unknown
Due 30 May 1989
Resolved 30 May 1989
Unknown
Issued 30 May 1989
Resolved
PROVE PROPER OPERATION OF ENTIRE FIXED BILGE PUMP SYSTEM.
Condition: Unknown
Due 30 May 1989
Resolved 30 May 1989
Unknown
Issued 30 May 1989
Resolved
PROVE PROPER OPERATION OF STERN LIGHT.
Condition: Unknown
Due 30 May 1989
Resolved 30 May 1989
Unknown
Issued 30 May 1989
Resolved
RE-NEW PFD LIGHTS FOR -24- LIFE JACKETS.
Condition: Unknown
Due 30 May 1989
Resolved 30 May 1989