THE SUMMER WIND

THE SUMMER WIND is a passenger vessel (inspected). The Coast Guard has recorded 52 inspections since 1996, most recently in January 2026, along with 170 deficiencies.

Records from 1996 to 2026. Most recent: inspection, 15 January 2026.

Built
Not recorded
Last inspected
15 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD4031
279604
Flag
UNITED STATES
367555000
Maury page id
psix-279604

Inspections, by type

…with no type recorded3
Years with a record 26 calendar years (1996–2026)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)90.0 ft × 18.5 ft × 8.2 ft
Registered tonnagegross 91 / net 73
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNot recorded
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFORT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 3 August 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it91 - Regulatory (Subpart C or D), Gross Ton
73 - Regulatory (Subpart C or D), Net Ton
91 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD4031MMSI 367555000 · active · compulsorily equipped · granted 1 September 2016, expires 13 September 2026
WCV3579MMSI not assigned · expired · compulsorily equipped · granted 2 November 1995, cancelled 7 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 52

15 January 2026 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8296747
8 January 2025 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8062793
12 August 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7979447
15 July 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7955182
14 November 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7825496
21 December 2022 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7629124
16 August 2022 Administrative Inspection · Internal Structural Exam · In-Service Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7535959
30 July 2022 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7524778
18 October 2021 COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7334694
17 November 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7097780
17 September 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7060005
23 October 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6840136
9 October 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6831126
21 November 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6581304
13 September 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6534769
11 October 2017 DAPI Audit · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6285262
13 October 2016 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6022272
1 September 2016 Internal Structural Exam · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5986627
23 August 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5981074
16 November 2015 Internal Structural Exam · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5764841
2 September 2011 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4133605
18 August 2011 COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4117304
18 November 2010 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3892154
2 September 2010 Internal Structural Exam · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3839909
1 February 2010 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3674002
2 December 2009 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3646385
6 March 2009 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3428549
25 November 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3368214
30 July 2008 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3282701
3 December 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3107366
6 October 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2806271
28 June 2006 COI Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2694490
9 November 2004 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2237188
8 September 2004 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2190449
16 June 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2100689
20 November 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1951302
10 October 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1687978
21 August 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1664203
27 June 2002 Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1637445
28 March 2002 Hull Examination · Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1598455
22 March 2002 Administrative Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1495809
7 February 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1484688
22 August 2001 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1453930
12 September 2000 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1386885
8 March 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1376075
16 August 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1413584
2 December 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 806137
19 August 1998 MARPOL Annex V Examination · Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1131444
3 February 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 781259
14 November 1996 Initial Construction-Excluding Oversight
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1435826
8 July 1996 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 767549
28 June 1996 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 207174

Deficiency record · 170

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 January 2026 Resolved
The fire pump outlet must be fitted with a pressure gauge. The fire pump was not fitted with a pressure gauge. 46 CFR 181.300(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 26 January 2026
Resolution: Pressure gauge installed. Test Sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 January 2026 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:Charts of large enough scale to make safe navigation possible. Vessel did not have up to date charts. Paper charts must be ENC-Derived Paper Charts. If Electronic chart plotter is utilized, it must be 7.8" X 7.8" display. 46 CFR 184.420(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 26 January 2026
Resolution: Charts purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 January 2026 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. 15 lifejackets had non-approved retroreflective tape. 46 CFR 186.604(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2026
Resolved 26 January 2026
Resolution: Retro replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 January 2025 Resolved
The number of penetrations in a watertight bulkhead must be minimized. Exhaust that penetrates aft bulkhead must be watertight.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 15 January 2025
Resolved 10 January 2025
Resolution: New flange installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2025 Resolved
A suitable metal marine type strainer meeting the requirements of the engine manufactuer must be installed. Metalic flame screen must be installed.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 15 January 2025
Resolved 10 January 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 January 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel iaw the terms of its COI. Anchor mounting plate support needs cover to prevent water from entering void below.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2025
Resolved 10 January 2025
Resolution: Cover installed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 12 August 2024 Resolved
No vessel which is required by § 67.7 to be documented may engage in unlimited coastwise trade or the fisheries without being documented in accordance with the requirements of this part. Vessel's COD expired 31 July 2024.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 August 2024
Resolution: Vessel renewed COD.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 30 July 2022 Resolved
Vessel was found with its MSD system's valve open to allow discharge overboard within a restricted area.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 30 July 2022
Resolved 31 July 2022
Resolution: NOV was issued.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 11 October 2017 Resolved
Seal all penetrations in collision bulkhead and make watertight. 46 CFR 177.13
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 6 November 2017
Resolution: Operator submitted images, MI accepted welding, cleared def.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 October 2017 Resolved
Provide junction boxes for all spliced wires underneath operating station console (fly bridge). 46 CFR 188.340
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 6 November 2017
Resolution: Operator submitted images of junction boxes, MI accepted, cleared def.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 September 2016 Resolved
COI not posted in a conspicuous place on vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Posted COI
Documentation › Certificates/Documents › Stability Letter
Issued 1 September 2016 Resolved
Stability Letter not posted at operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Posted Stability Letter
Documentation › Markings/Placards › Lifejacket Placard
Issued 1 September 2016 Resolved
Lifejacket placard on upper deck was under lid of only one of many compartments. Provide lifejacket placard in a conspicuous location on upper deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Posted 4 placards in conspicous places.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 1 September 2016 Resolved
Rectoreflective material found heavily soiled and torn on several lifejackets. Renew as original.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Lifejackets replaced with brand new lifejackets
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 September 2016 Resolved
Dead-end wires found in fwd bulkhead in master pax cabin.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Dead end wires removed
Electrical › Electrical Distribution System (service) › Cable
Issued 1 September 2016 Resolved
Provide permanent wire connection for LED strip lights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Construction/Loadline › Structures › Scuttle
Issued 1 September 2016 Resolved
Forward hatch in way of collision bulkhead and aft lazerette hatch found without gaskets.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Gaskets renewed
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 September 2016 Resolved
Lanyard on life-ring light found excessively worn. Renew as orig.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: New lifeline
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 September 2016 Resolved
Replace wing-nut battery terminal connections with permanent connections.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: New connections used
Navigation › Piloting/Steering › Marine Charts
Issued 1 September 2016 Resolved
Vessel did not have any charts or publicaitons onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2016
Resolution: New Charts and all required publications were purchased and placed onboard vessel.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 September 2016 Resolved
Provide locking device for oven in galley.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Locking device created and installed
Engineering › Bilge Water Management System › Valve
Issued 1 September 2016 Resolved
Replace ball valve on bilge piping aft of collision bulkhead with screw-down type valve.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 25 November 2018
Resolution: Completed.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 1 September 2016 Resolved
Repair ventilation damper (forward/starboard side) in engine room. Damper would not properly close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Ventilation cover repaired
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 September 2016 Resolved
Cable guides for port side railing found wasted/broken.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Cable replaced
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 1 September 2016 Resolved
Repair emergency lighting and remove storage in forward staterooms. Reduced to 03 overnight accomodations.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Emergency lighting replaced and operational
Engineering › Lubricating Oil Service System › Piping
Issued 1 September 2016 Resolved
Repair oil leak on port maine engine in way of the fuel pump.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Oil leak repaired
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 August 2016 Resolved
Vessel is prohibited from carrying passengers prior to completion of a COI renewal inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 November 2015 Resolved
Provide service for fire extinguishing equipment. Service expires 17Nov15.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2015
Resolved 18 November 2015
Resolution: Received satisfactory service report.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 November 2015 Resolved
Operator to provide pot rails and oven latch for stove.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 19 November 2017
Fire Fighting › Fire Pumps › Pressure
Issued 16 November 2015 Resolved
Fire pump discharge pressure inadequate as determined by installed gauge. Provide satsfactory pressure.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 19 November 2017
Stability › Incline Test › General
Issued 18 August 2011 Resolved
Prior to 01DEC2011, comply with passenger weight and inspected vessel stability requirements: Final Rule (Federal Register Vol. 75, No. 239, USCG-2007-0030, December 14, 2010) IAW CG-543 Policy Letter 11-03 dated April 08, 2011.
Due 1 December 2011
Resolved 1 October 2012
Engineering › Bilge Water Management System › Piping
Issued 18 August 2011 Resolved
Remove plastic union in bilge piping located in the "pump room" in way of the elbow of the bilge line. Renew with approved metallic piping materials IAW 46 CFR 182.720.
Due 1 September 2011
Resolved 2 September 2011
Resolution: The owner removed the plastic union and installed a metallic union.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 18 August 2011 Resolved
Remove plastic waste receptacles and renew with non-combustible type IAW 46 CFR 177.405(f).
Due 1 September 2011
Resolved 2 September 2011
Resolution: The owner removed the plastic waste receptacle and purchased a non-combustible type.
Electrical › Electrical Distribution System (service) › Cable
Issued 18 November 2010 Resolved
Properly terminate all dead-end wires throughout vsl or remove.
Action required: 705 - Other - as specified
Due 2 December 2010
Resolved 4 January 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 November 2010 Resolved
Properly connect wires on/in stbd storage deck box/locker just aft of upper bar.
Action required: 705 - Other - as specified
Due 2 December 2010
Resolved 4 January 2011
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 18 November 2010 Resolved
Remove power/electrical wiring from old transfer pump or provide guard on rotating shaft.
Action required: 705 - Other - as specified
Due 2 December 2010
Resolved 4 January 2011
Construction/Loadline › Structures › Manhole
Issued 18 November 2010 Resolved
Provide dogs on the following windows below the main deck.
Action required: 705 - Other - as specified
Due 2 December 2010
Resolved 4 January 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 18 November 2010 Resolved
Make repairs to oil leak on stbd engine outboard side.
Action required: 705 - Other - as specified
Due 2 December 2010
Resolved 4 January 2011
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 18 November 2010 Resolved
Replace wasted engine room vent fan cage/grill.
Action required: 705 - Other - as specified
Due 2 December 2010
Resolved 4 January 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 November 2010 Resolved
Replace anchor light bulb and show proper operation.
Action required: 705 - Other - as specified
Due 2 December 2010
Resolved 4 January 2011
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 18 November 2010 Resolved
Provide non-conductive mat in front of switchboard in crew quarters.
Action required: 705 - Other - as specified
Due 2 December 2010
Resolved 4 January 2011
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 18 November 2010 Resolved
Properly mark all breakers in electrical panels throughout vessel.
Action required: 705 - Other - as specified
Due 2 December 2010
Resolved 4 January 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 November 2010 Resolved
Remove unused electrical wiring from speaker/audio control locker, main deck, fwd, port side.
Action required: 705 - Other - as specified
Due 2 December 2010
Resolved 4 January 2011
Engineering › Fuel Oil Service System › Valve, Control
Issued 18 November 2010 Resolved
Show proper operation of fuel shut off.
Action required: 705 - Other - as specified
Due 2 December 2010
Resolved 18 November 2010
Resolution: Corrected on the spot.
Construction/Loadline › Hull › Keel Plate
Issued 2 September 2010 Resolved
Submit repair proposal to renew hull plate IWO AFT stbd side keel where wasted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2010
Engineering › Bilge Water Management System › Piping
Issued 2 September 2010 Resolved
Replace plastic union on forepeak bilge suction line with aluminum union.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2010
Engineering › Bilge Water Management System › Manifold
Issued 2 September 2010 Resolved
Provide approval or acceptance of hose installed in bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2010
Construction/Loadline › Penetrations › Pipe Flange
Issued 2 September 2010 Resolved
Repair or replace spool piece port head sink drain (outboard).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2010
Engineering › Bilge Water Management System › Manifold
Issued 2 September 2010 Resolved
Replace/renew flexible hose IWO bilge pipe at manifold with original aluminum pipe (hard pipe) as specified on the "approved" plans.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2010
Engineering › Fuel Oil Service System › Piping
Issued 2 December 2009 Resolved
Make proper repair tom fuel leak on Stbd Gen IVO fuel injectors.
Action required: 705 - Other - as specified
Due 9 December 2009
Resolved 16 December 2009
Navigation › Piloting/Steering › Magnetic Compass
Issued 2 December 2009 Resolved
Prove proper operation of compass light on both compasses.
Action required: 705 - Other - as specified
Due 9 December 2009
Resolved 16 December 2009
Fire Fighting › Fire Pumps › Pressure
Issued 2 December 2009 Resolved
Prove main fire pump meets pressure requirements in 46 CFR 181.300 (b).
Action required: 705 - Other - as specified
Due 9 December 2009
Resolved 16 December 2009
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 December 2009 Resolved
Provide emergency lighting for aft port and stbd staterooms IAW 46 CFR 183.432.
Action required: 705 - Other - as specified
Due 2 January 2010
Resolved 18 November 2010
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 25 November 2008 Resolved
Mark bow of vessel with vessel name.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 6 March 2009
Documentation › Markings/Placards › Warning Signs
Issued 25 November 2008 Resolved
Provide and post at operating station emergency broadcast placard.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 8 December 2008
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 November 2008 Resolved
Provide cover for outlet below main deck wheel.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 8 December 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 November 2008 Resolved
Remove dead end wires under main deck operating station.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 8 December 2008
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 25 November 2008 Resolved
Secure warmer for sea.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 8 December 2008
Engineering › Bilge Water Management System › Strainer
Issued 25 November 2008 Resolved
Replace bilge pick up strainer FWD of collision BHD.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 8 December 2008
Communications › Radio Communications › EPIRB
Issued 25 November 2008 Resolved
Replace hydrostatic release on EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 November 2008 Resolved
Provide proper securing bracket for hatch, when open, IWO flying bridge operation station.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 8 December 2008
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 25 November 2008 Resolved
Provide bonding wire for flex hose for fuel fill pipe IWO tank.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 8 December 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 November 2008 Resolved
Relocate bilge high water float switch in eng. room (lower).
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 8 December 2008
Operations/Management › Pollution › Control of Discharge of Oil
Issued 25 November 2008 Resolved
Clean/degrease bilge just aft of the E/R fwd BHD alley.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 8 December 2008
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 25 November 2008 Resolved
Replace fuel hose on STBD generator with SAE J 1942 hose.
Action required: 705 - Other - as specified
Due 10 December 2008
Resolved 8 December 2008
Engineering › Bilge Water Management System › Not Operational
Issued 30 November 2007 Resolved
Prove proper operation of fixed bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2007
Resolved 6 December 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 30 November 2007 Resolved
Provide valid servicing certificate for engine room fixed system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2007
Resolved 6 December 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 30 November 2007 Resolved
Provide valid servicing certificate for B-I portable fire extinguisher located in the galley or replace with serviced one.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2007
Resolved 6 December 2007
Fire Fighting › Fire Pumps › Pressure
Issued 30 November 2007 Resolved
Make repairs to fire pump gauge.
Action required: 705 - Other - as specified
Due 10 December 2007
Resolved 6 December 2007
Communications › Alarms/Indicators › Rate of Turn Indicator
Issued 30 November 2007 Resolved
Provide RPM gauge for Port MDE
Action required: 705 - Other - as specified
Due 10 December 2007
Resolved 6 December 2007
Engineering › Bilge Water Management System › Manifold
Issued 30 November 2007 Resolved
Make corrections to bilge system operating instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2007
Resolved 6 December 2007
Personnel › Training › Familiarization Training
Issued 30 November 2007 Resolved
Provide crew familiarization training for bilge and fire systems.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2007
Resolved 6 December 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 30 November 2007 Resolved
Make repairs to aft portside deck (flood) lighting.
Action required: 705 - Other - as specified
Due 10 December 2007
Resolved 6 December 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 November 2007 Resolved
Provide Coast Guard approved first aid kit.
Action required: 705 - Other - as specified
Due 10 December 2007
Resolved 20 December 2007
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 5 September 2006 Resolved
Provide missing documentation for completion of drug audit.
Due 12 September 2006
Resolved 12 September 2006
Documentation › Certificates/Documents › FCC SSL
Issued 5 September 2006 Resolved
Provide FCC radio license for vessel.
Due 12 September 2006
Resolved 12 September 2006
Communications › Radio Communications › EPIRB
Issued 5 September 2006 Resolved
Properly log EPIRB test.
Due 12 September 2006
Resolved 3 October 2006
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 5 September 2006 Resolved
Repair fixed spotlight.
Due 12 September 2006
Resolved 3 October 2006
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 5 September 2006 Resolved
Properly mount GPS receiver.
Due 12 September 2006
Resolved 3 October 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 September 2006 Resolved
Properly mount electrical box in starboard life jacket locker in main salon.
Due 12 September 2006
Resolved 3 October 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 September 2006 Resolved
Properly mount electrical boxes and cable under port couch in main salon.
Due 12 September 2006
Resolved 3 October 2006
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 5 September 2006 Resolved
Properly mount AC unit under port couch un main salon and AC unit in galley.
Due 12 September 2006
Resolved 3 October 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 September 2006 Resolved
Remove dead ended wires under port couch in main salon.
Due 12 September 2006
Resolved 3 October 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 September 2006 Resolved
Properly mount electrical box in crew cabin port and above crew table starboard. Remove dead ended wires starboard.
Due 12 September 2006
Resolved 3 October 2006
Communications › Alarms/Indicators › Fire Alarm
Issued 5 September 2006 Resolved
Provide smoke detector batteries.
Due 12 September 2006
Resolved 3 October 2006
Fire Fighting › Means of Escape › Emergency Lighting
Issued 5 September 2006 Resolved
Properly repair emergency lighting bottom of main stairway.
Due 12 September 2006
Resolved 3 October 2006
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 5 September 2006 Resolved
Provide ground strap for fuel oil fill pipe in engine room.
Due 12 September 2006
Resolved 6 October 2006
Fire Fighting › Ventilation Systems › Operating Controls
Issued 5 September 2006 Resolved
Provide means to close top vent to engine room.
Due 12 September 2006
Resolved 3 October 2006
Engineering › Fuel Oil Service System › Filter
Issued 28 June 2006 Resolved
Provide plugs for the petcocks on all Raycor fuel filters.
Action required: 705 - Other - as specified
Resolved 24 August 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 June 2006 Resolved
Properly secure raw water piping for port MDE.
Action required: 705 - Other - as specified
Resolved 24 August 2006
Engineering › Steering Gear System › Rudder
Issued 28 June 2006 Resolved
Provide rudder stops.
Action required: 705 - Other - as specified
Resolved 24 August 2006
Engineering › Bilge Water Management System › Piping
Issued 28 June 2006 Resolved
Provide double clamps and renew flex hoses on all pipes at bilge manifold.
Action required: 705 - Other - as specified
Resolved 24 August 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 28 June 2006 Resolved
Replace broken light cover on port side.
Action required: 705 - Other - as specified
Resolved 24 August 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 June 2006 Resolved
Replace raw water hose on starboard generator.
Action required: 705 - Other - as specified
Resolved 24 August 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 June 2006 Resolved
Remove deadended wires on port side by eleectric bilge pump.
Action required: 705 - Other - as specified
Resolved 24 August 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 28 June 2006 Resolved
Clean oil from exhaust fans port side engine room.
Action required: 705 - Other - as specified
Resolved 24 August 2006
Construction/Loadline › Hull › Stringer
Issued 28 June 2006 Resolved
Re-weld deck stringer on starboard side outboard MDE.
Action required: 705 - Other - as specified
Resolved 24 August 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 June 2006 Resolved
Properly repair broken ladder riser (3rd from bottom) to ladder leading to engine room.
Action required: 705 - Other - as specified
Resolved 24 August 2006
Construction/Loadline › Hull › Transverse Frame
Issued 28 June 2006 Resolved
Drill stop cracks in aft fuel/water tank.
Action required: 705 - Other - as specified
Resolved 24 August 2006
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 28 June 2006 Resolved
Properly secure fuel oil pipe running through aft fuel/water tank.
Action required: 705 - Other - as specified
Resolved 24 August 2006
Engineering › Bilge Water Management System › Piping
Issued 28 June 2006 Resolved
Remove flex hose on forward bilge suction line and replace with metalic slip joint fiting.
Action required: 705 - Other - as specified
Resolved 24 August 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 28 June 2006 Resolved
Provide report for CO2 servicing.
Due 12 September 2006
Resolved 3 October 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 9 November 2004 Resolved
Provide proof of crew enrollment on the Drug and Alcohol Program Consortium and the crew roster.
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 18 January 2005
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 9 November 2004 Resolved
Provide proof of submission of MIS form for 2003.
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 18 January 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 November 2004 Resolved
Provide proof of proper operation of CO2 system for the engine room.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2004
Resolution: Technician went onboard and made proper repair for a satisfactory operation of the system.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 9 November 2004 Resolved
All accomodations require UL 217 Individual Modular Smoke Detectors.
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 18 January 2005
Personnel › Training › First Aid/CPR
Issued 9 November 2004 Resolved
Provide proof of CPR training for 50% of the crew on board. NVIC 1-91 Encl.(1) I/E.1
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 18 January 2005
Fire Fighting › Nozzles › Condition
Issued 9 November 2004 Resolved
Fire nozzle for Port Side fire station nor working properly.
Condition: Design Flaw
Due 9 December 2004
Resolved 9 December 2004
Resolution: Nozzle replaced and proved proper operation.
Communications › Alarms/Indicators › Speed/Distance Indicator
Issued 9 November 2004 Resolved
RPM gauge found inoperable.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 18 January 2005
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 9 November 2004 Resolved
Inoperative oil pressure gauge for the Port side engine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 18 January 2005
Construction/Loadline › Hull › Side Shell
Issued 9 November 2004 Resolved
Dogs missing for the Port and Starboard side port lights cover in Engine Room.
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 18 January 2005
Lifesaving › Lifejacket/PFD (Type II) › Retroreflective Material
Issued 9 November 2004 Resolved
Three Adults lifejackets require replacement of approved retro reflective tape.
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 9 December 2004
Resolution: All retro reflective tape replaced.
Engineering › Bilge Water Management System › Piping
Issued 9 November 2004 Resolved
Properly repair bilge piping where temporary repaired with rubber hose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 18 January 2005
Fire Fighting › Fire Main › Material
Issued 9 November 2004 Resolved
Properly repair fire piping where temporary repaired with rubber hose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 18 January 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 November 2004 Resolved
Service portable fire extinguisher in storage locker and the flying bridge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2004
Resolution: Extiguisher replaced by fire technician.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 9 November 2004 Resolved
Properly label bilge alarm panel and ensure all lights are working.
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 18 January 2005
Construction/Loadline › Structures › Deck Plating
Issued 9 November 2004 Resolved
Secure deck plates in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 18 January 2005
Construction/Loadline › Structures › Ventilators
Issued 9 November 2004 Resolved
Repair three ventilation fans in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 18 January 2005
Construction/Loadline › Hull › Hull Plating
Issued 8 September 2004 Resolved
Hull coatings failing making it difficult to inspected the hull. Possible pitting and damage under loose pieces of coating. Remove all loose material and properly prepare hull for inspection prior to new coating being applied.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All Dry Dock Items Clear, Credit for dry dock recommended.
Construction/Loadline › Penetrations › Bottom Plug
Issued 8 September 2004 Resolved
Plugs in keel fuel tank MAY have to be removed. Item to be reviewed by the Coast Guard Marine Safety Center (MSC). Provide any information in writing as to the installation, to the disposition of and/or and the need for plugs
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2004 Resolved
Dead end and improper cable in box on aft deck. Remove dead cable or properly terminate in an electrical box
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2004 Resolved
Improper splices and wire in main saloon and aft deck. Ensure all wire connection are properly made with Butt connecters or placed in a proper electrical box. All new work must be inspected to the satisfaction of the attending Marine inspector before being covered over.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2004 Resolved
Electrical box in fresh water tank storeroom was loose wiring and is missing a cover. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Engineering › Fuel Oil Service System › Tank
Issued 8 September 2004 Resolved
Fuel leak from fuel tank into cofferdam. Provide proof of location of the leak and submit a repair proposal prior to commencing work. Any repair to tank will have to be pressure tested in accordance with 46CFR58-50-10.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2004 Resolved
Improper wiring in Master's Cabin. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 8 September 2004 Resolved
Prove installation of lead ballast to the Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2004 Resolved
Improper wiring to port exhaust fan. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Engineering › Fuel Oil Service System › Tank
Issued 8 September 2004 Resolved
Have fuel tanks tested gas free and ready for inspection. Maintain a proper Chemist Certificate with the Yard's Competent Person.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2004
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Fire Fighting › Fire Main › Condition
Issued 8 September 2004 Resolved
Improper use of hose on fire main system. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2004 Resolved
Improper wiring to strb deck winch. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 8 September 2004 Resolved
No closure on fan in aft strb corner of main machinery space. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2004 Resolved
Improper wiring in port aft corner of machinery space next to batteries. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 8 September 2004 Resolved
Oil stow on and around batteries, fire hazard. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 8 September 2004 Resolved
Piping to the raw water discharge and v-drive cooling is PVC piping. This piping considered vital piping and therefore must be a ferrous material. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 8 September 2004 Resolved
Hole in overhead of machinery space. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Construction/Loadline › Penetrations › Valve Flange
Issued 8 September 2004 Resolved
Bilge pump and fire pump discharge must be fitted with a positive closing valve before any hoes are fitted. Hoses must be kept to a minimum and fitted with two hose clamps. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Fire Fighting › Fire Pumps › Bearings
Issued 8 September 2004 Resolved
Provide a second independent fire pump or a proper bilge pump cross over line and prove proper operation of both systems proper to carriage of passengers. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2004 Resolved
Dead and proper wiring throughout the machinery space. Remove dead cable or properly terminate in an electrical box.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Engineering › Bilge Water Management System › Piping
Issued 8 September 2004 Resolved
Provide strainer on bilge piping pickup in void aft of fore peak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2004 Resolved
Improper wiring in crew head. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Construction/Loadline › Penetrations › Valve Flange
Issued 8 September 2004 Resolved
Provide metallic nipple at through hull fitting in fwd void
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Engineering › Bilge Water Management System › Piping
Issued 8 September 2004 Resolved
Provide cutoff valve for fore peak void bilge piping
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Engineering › Bilge Water Management System
Issued 20 November 2003 Resolved
Demonstrate operation of the fixed bilge system. Currently unable to take suction from any space. CID authorized operation with portable submersible pumps until permenent repairs are completed. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Due 28 November 2003
Resolved 28 November 2003
Resolution: Renewed piping IWO numerous spaces. Satisfactory test observed in 3 compartments.
Fire Fighting › Ventilation Systems
Issued 21 August 2002 Resolved
Re-adjust ventilation closure pull cables to provide positive closure upon activation. LEGACY COMPONENT DESC: Ducts
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2002
Resolved 5 September 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 August 2002 Resolved
Install proper CO2 piping, brass piping not allowed. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2002
Resolved 5 September 2002
Fire Fighting › Remote Fuel Shutoff
Issued 21 August 2002 Resolved
Readjust fuel shut off valve pull cables, to provide positive closure upon activation.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2002
Resolved 5 September 2002
Electrical › Electric Supply System (service)
Issued 21 August 2002 Resolved
Remove jumper cable from starboard batteries. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2002
Resolved 5 September 2002
Electrical › Lighting (service)
Issued 21 August 2002 Resolved
Install lights in lower port side stateroom. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2002
Resolved 5 September 2002
Electrical › Lighting (emergency)
Issued 21 August 2002 Resolved
Repair emergency lighting in master stateroom. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2002
Resolved 28 November 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 21 August 2002 Resolved
Properly mount all portable fire extinguishers. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2002
Resolved 5 September 2002
Electrical › Lighting (service)
Issued 21 August 2002 Resolved
Install electrical switch covers throughout vessel. LEGACY COMPONENT DESC: Switch
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2002
Resolved 5 September 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 21 August 2002 Resolved
Repair port exhaust muffler hose water leak. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2002
Resolved 5 September 2002
Engineering › Fuel Oil Service System
Issued 21 August 2002 Resolved
Repair fuel leaks on day tank hose connections and valves. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 7 September 2002
Resolved 5 September 2002
Communications › Audible Communications
Issued 21 August 2002 Resolved
No overnight accomadations authorized until PA system is operational in all spaces. LEGACY COMPONENT DESC: Public Address System
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2002
Resolved 28 November 2003
Communications › Audible Communications
Issued 21 August 2002 Resolved
Provide second source of power for PA system. LEGACY COMPONENT DESC: Public Address System
Condition: Improper Installation
Due 30 January 2003
Resolved 28 November 2003
Construction/Loadline
Issued 22 August 2001 Resolved
Provide securing and retaining device for lazette hatch.
Condition: Unknown
Due 5 September 2001
Resolved 22 March 2002
Fire Fighting
Issued 22 August 2001 Resolved
Provide proper piping for CO2 fixed system in the engine room.
Condition: Unknown
Due 5 September 2001
Resolved 22 March 2002
Construction/Loadline
Issued 22 August 2001 Resolved
Provide valve on sink drain below crews quarters in AC compartment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2002
Resolved 10 October 2002
Engineering
Issued 22 August 2001 Resolved
Provide fuel filter flame shields.
Condition: Unknown
Due 4 September 2001
Resolved 22 March 2002
Documentation
Issued 22 August 2001 Resolved
Provide FCC operator's license for the Master.
Condition: Unknown
Due 5 September 2001
Resolved 22 March 2002
Engineering
Issued 22 August 2001 Resolved
Provide guards on both main engine alternators.
Condition: Unknown
Due 5 September 2001
Resolved 29 March 2002
Construction/Loadline › Hull › Side Shell
Issued 22 August 2001 Resolved
Provide dead covers for port lights prior to operating on Limited Coastwiseroute.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 November 2004
Resolution: All worklist items cleared, recommend credit for dry dock, 11/09/2004
Construction/Loadline
Issued 22 August 2001 Resolved
Provide visual and audio alarms to indicate high water level on the fly bridge since this is used as the operating station.
Condition: Unknown
Due 5 September 2001
Resolved 22 March 2002
Construction/Loadline
Issued 22 August 2001 Resolved
Provide valves on all thrugh hull penetrations that are within 6 inches of the deepest waterline.
Condition: Unknown
Due 28 March 2002
Resolved 17 October 2002
Construction/Loadline
Issued 22 August 2001 Resolved
Provide bilge suction line for aft compartment and high water alarm.
Condition: Unknown
Due 5 September 2001
Resolved 22 March 2002
Fire Fighting
Issued 22 August 2001 Resolved
Provide specific fire fighting procedures.
Condition: Unknown
Due 5 September 2001
Resolved 22 March 2002
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 22 August 2001 Resolved
Prior to Limited Coastwise charter, provide 406 Mhz EPIRB.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 November 2004
Resolution: Clear and re-addressed in 2235188
Accommodation/Occupational Safety
Issued 22 August 2001 Resolved
Secure overnight accomodations for crew and passengers until escape hatchesare made operable from both sides.
Condition: Unknown
Due 1 November 2001
Resolved 22 March 2002
Documentation
Issued 19 August 1998 Resolved
PROVIDE FCC SAFETY CERTIFICATE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Documentation
Issued 19 August 1998 Resolved
PROVIDE FCC OPERATOR'S PERMIT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.