Records from 2016 to 2026. Most recent: inspection, 15 January 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 19
15 January 2026
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8296747
8 January 2025
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8062793
12 August 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7979447
15 July 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7955182
14 November 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7825496
21 December 2022
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7629124
16 August 2022
Administrative Inspection · Internal Structural Exam · In-Service Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7535959
30 July 2022
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7524778
18 October 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7334694
17 November 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7097780
17 September 2020
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7060005
23 October 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6840136
9 October 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6831126
21 November 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6581304
13 September 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6534769
11 October 2017
DAPI Audit · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6285262
13 October 2016
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6022272
1 September 2016
Internal Structural Exam · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5986627
23 August 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5981074
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 January 2026
Resolved
The fire pump outlet must be fitted with a pressure gauge.
The fire pump was not fitted with a pressure gauge.
46 CFR 181.300(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 26 January 2026
Resolution: Pressure gauge installed. Test Sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 January 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:Charts of large enough scale to make safe navigation possible. Vessel did not have up to date charts. Paper charts must be ENC-Derived Paper Charts. If Electronic chart plotter is utilized, it must be 7.8" X 7.8" display.
46 CFR 184.420(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 26 January 2026
Resolution: Charts purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 January 2026
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. 15 lifejackets had non-approved retroreflective tape.
46 CFR 186.604(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2026
Resolved 26 January 2026
Resolution: Retro replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 January 2025
Resolved
The number of penetrations in a watertight bulkhead must be minimized.
Exhaust that penetrates aft bulkhead must be watertight.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 15 January 2025
Resolved 10 January 2025
Resolution: New flange installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2025
Resolved
A suitable metal marine type strainer meeting the requirements of the engine manufactuer must be installed.
Metalic flame screen must be installed.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 15 January 2025
Resolved 10 January 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 January 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel iaw the terms of its COI.
Anchor mounting plate support needs cover to prevent water from entering void below.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2025
Resolved 10 January 2025
Resolution: Cover installed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 12 August 2024
Resolved
No vessel which is required by § 67.7 to be documented may engage in unlimited coastwise trade or the fisheries without being documented in accordance with the requirements of this part. Vessel's COD expired 31 July 2024.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 August 2024
Resolution: Vessel renewed COD.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 30 July 2022
Resolved
Vessel was found with its MSD system's valve open to allow discharge overboard within a restricted area.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 30 July 2022
Resolved 31 July 2022
Resolution: NOV was issued.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 11 October 2017
Resolved
Seal all penetrations in collision bulkhead and make watertight. 46 CFR 177.13
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 6 November 2017
Resolution: Operator submitted images, MI accepted welding, cleared def.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 October 2017
Resolved
Provide junction boxes for all spliced wires underneath operating station console (fly bridge). 46 CFR 188.340
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 6 November 2017
Resolution: Operator submitted images of junction boxes, MI accepted, cleared def.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 September 2016
Resolved
COI not posted in a conspicuous place on vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Posted COI
Documentation › Certificates/Documents › Stability Letter
Issued 1 September 2016
Resolved
Stability Letter not posted at operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Posted Stability Letter
Documentation › Markings/Placards › Lifejacket Placard
Issued 1 September 2016
Resolved
Lifejacket placard on upper deck was under lid of only one of many compartments. Provide lifejacket placard in a conspicuous location on upper deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Posted 4 placards in conspicous places.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 1 September 2016
Resolved
Rectoreflective material found heavily soiled and torn on several lifejackets. Renew as original.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Lifejackets replaced with brand new lifejackets
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 September 2016
Resolved
Dead-end wires found in fwd bulkhead in master pax cabin.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Dead end wires removed
Electrical › Electrical Distribution System (service) › Cable
Issued 1 September 2016
Resolved
Provide permanent wire connection for LED strip lights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Construction/Loadline › Structures › Scuttle
Issued 1 September 2016
Resolved
Forward hatch in way of collision bulkhead and aft lazerette hatch found without gaskets.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Gaskets renewed
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 September 2016
Resolved
Lanyard on life-ring light found excessively worn. Renew as orig.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: New lifeline
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 September 2016
Resolved
Replace wing-nut battery terminal connections with permanent connections.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: New connections used
Navigation › Piloting/Steering › Marine Charts
Issued 1 September 2016
Resolved
Vessel did not have any charts or publicaitons onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2016
Resolution: New Charts and all required publications were purchased and placed onboard vessel.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 September 2016
Resolved
Provide locking device for oven in galley.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Locking device created and installed
Engineering › Bilge Water Management System › Valve
Issued 1 September 2016
Resolved
Replace ball valve on bilge piping aft of collision bulkhead with screw-down type valve.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 25 November 2018
Resolution: Completed.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 1 September 2016
Resolved
Repair ventilation damper (forward/starboard side) in engine room. Damper would not properly close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Ventilation cover repaired
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 September 2016
Resolved
Cable guides for port side railing found wasted/broken.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Cable replaced
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 1 September 2016
Resolved
Repair emergency lighting and remove storage in forward staterooms. Reduced to 03 overnight accomodations.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Emergency lighting replaced and operational
Engineering › Lubricating Oil Service System › Piping
Issued 1 September 2016
Resolved
Repair oil leak on port maine engine in way of the fuel pump.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 22 September 2016
Resolution: Oil leak repaired
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 August 2016
Resolved
Vessel is prohibited from carrying passengers prior to completion of a COI renewal inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2017