Records from 1996 to 2025. Most recent: inspection, 11 August 2025.
Documentation record
Registered dimensions (L × B × D)81.4 ft × 23.5 ft × 12.9 ft
Registered tonnagegross 134 / net 40
ITC dimensions (L × B × D)81.4 ft × 23.5 ft × 12.9 ft
ITC tonnagegross 134 / net 40
Builderbuilder not recorded · SAVANNAH · built 1961
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it134 - Convention (Subpart B), Gross Ton
40 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
11 August 2025
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8209182
23 July 2025
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8194246
1 May 2024
Examination of Repairs · Internal Structural Exam · Drydock Exam · Administrative Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7907975
19 July 2023
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7746896
3 June 2022
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7467679
21 April 2022
Initial Certification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7428607
22 November 2017
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6311638
15 August 2011
Industry Initiated Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4119392
14 November 2006
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2820704
3 January 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2576545
29 September 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2503547
1 February 2005
Hawser Check · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2286556
12 January 2005
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2273777
9 June 2004
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2113506
7 April 2003
Type not recorded
No type recorded · Station Fort Pierce · USCG Southeast District (CGD-SE) · Activity 1770867
7 April 2003
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1771532
3 December 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1481656
27 July 1999
Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1107501
14 August 1998
Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1131216
29 July 1998
Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1129414
14 May 1997
MARPOL Annex V Examination · Uninspected Towing Vessel · MARPOL Annex I Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1105730
9 January 1997
MARPOL Annex V Examination · MARPOL Annex I Examination · Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1102421
12 January 1996
Uninspected Towing Vessel · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1390176
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 August 2025
Resolved
Navigational Day Shapes; vessel fitted with one "Dimond", missing required three "Balls", iaw Inland Nav Rules 27 & 30.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2025
Resolved 11 August 2025
Resolution: Received e-mail with statement and photo reflecting items procured.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 8 August 2025
Resolved
Observed a new "Replacement" Fire Detection Alarm Panel installed in Pilot House. Equipment Spec's and PE letter be submitted. iaw 46 CFR 142.330
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2025
Resolved 8 August 2025
Resolution: Equipment Spec's and PE Letter provided and accepted.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 8 August 2025
Resolved
Vessel equipped with one line throwing device, four required & missing 1500 ft messenger line. Obtain and install iaw 46 CFR 141.385 & 46 CFR 160.040
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2025
Resolved 11 August 2025
Resolution: Received e-mail with statement and photo reflecting items procured.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 8 August 2025
Resolved
Engine Room, Air receiver relief valve failed to close after opening by hand. Service or renew, & provide Certificate of testing. IAW 46 CFR 143.300
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2025
Resolved 13 November 2025
Resolution: Cert, photo and statement received from company rep.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 August 2025
Resolved
Both SSDG' missing RPM gauges. Install per 46 CFR 143.230(c)(3).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2025
Resolved 11 August 2025
Resolution: Received e-mail with statement and photo's reflecting rpm gauges procured and installed.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 8 August 2025
Resolved
Missing and required MSD Approval Cert be provided. IAW 33 CFR, Part 159
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2025
Resolved 14 August 2025
Resolution: USCG Cert of Approval provided. MSD type approval number 159.015/702/0 Model 1200 Capacity 73.18 per day.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 May 2024
Resolved
Verification of compliance with the construction and arrangement design standards of this part must be performed according to the 46 CFR 144.135 table.
The vessel is hauled out and has made alterations to the hull and internal framing of the lazarette space.
Submit design standard plans for review to MSC and approved plans will need to be verified by attending CG Marine Inspector prior to operations.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2024
Resolution: Per MSC Letter H1-2403856, all Lazarette Structural Alterations, per Glowacki Engineering Dwg. No. 2418 S-1, Rev. (-), all Lazarette Structural Arrgts, Frames 45 Thru 52,” 3 were verified, satisfied and complete.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 April 2022
Resolved
Extension cords must not be used as a permanent connection. multiple ext cords and powerstrips were used for connectionon galley, berthing,and engine room
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 3 May 2022
Resolution: Rcvd photos of spaces
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 April 2022
Resolved
Nav assessment was not logged in vessel's logbook, Records of drills must also be logged
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 3 May 2022
Resolution: Vessel produced new Log Book with proper entries
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 April 2022
Resolved
VSO must ensure that at least one security drill is conducted every 3 months
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 3 June 2022
Resolution: Submitted photo evidence of quaterly drill.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 21 April 2022
Resolved
Each ship subject to the bridge-to-bridge act must have onboard a radio operator who holds a radiotelephone operator permit, Master did not have a permit
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 3 May 2022