Records from 1999 to 2019. Most recent: inspection, 3 June 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 30
3 June 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6702072
5 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5876271
14 December 2015
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5781598
22 August 2014
Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4961320
5 August 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4939917
28 March 2014
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4824305
12 July 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4388036
1 June 2012
Annual Inspection · MARPOL Annex IV Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4329653
6 September 2011
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4133606
25 January 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3669727
1 July 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3519592
20 May 2008
Re-Inspection · Deficiency Check · Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3213033
2 May 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3197102
27 June 2006
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2666323
27 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502018
12 May 2005
Cargo Tank Internal · Examination of Repairs · MTSA/ISPS Verification · COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2355724
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2294016
17 June 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2101191
3 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979619
27 May 2003
Cargo Tank Internal · Re-Inspection · Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1796509
15 May 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1617089
30 July 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1069820
29 May 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387083
10 April 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 231915
21 July 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1051951
24 May 2000
Initial Construction-Excluding Oversight · Deadweight Survey · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1361510
31 March 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818368
9 January 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 814493
30 June 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 795306
1 February 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 813131
Lifesaving › Launching Appliances › Davit
Issued 5 August 2014
Resolved
Prior to operation, provide proof of rescue boat davit repair per manufactures specification (authorized service representative).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 August 2014
Resolved 3 September 2014
Resolution: Observed proper repair IAW manufacturer spec. All sat.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 5 August 2014
Resolved
Provide rescue boat release hook rig arrangement for operation and stowage (pelican hook in fall preventer needs shackle, rescue davit emergency self launch apparatus / cable pulleys broken and not aligned for emergency operation).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2014
Resolved 3 September 2014
Resolution: Inspected repair to rescue boat davit. All sat.
Fire Fighting › Fire Pumps › Suction Valve
Issued 5 August 2014
Resolved
Prove proper operation of emergency fire pump (pump unable to prime and maintain required PSI or any PSI).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 August 2014
Resolved 3 September 2014
Resolution: Observed operation of e-fire pump at 105 psi from helm guage. All sat.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 6 September 2011
Resolved
Automation test procedures not updated to include new bow thruster engine.
Action required: 705 - Other - as specified
Resolved 11 January 2012
Resolution: Automation procedures an board and approved.
Construction/Loadline › Structures › Door
Issued 6 September 2011
Resolved
Lower engine room door indicator switch needs adjustment
Due 6 October 2011
Resolved 5 October 2011
Resolution: Adjusted switch
Engineering › Fuel Oil Service System › Piping
Issued 6 September 2011
Resolved
#4 stbd fuel tank sounding tube cap striped and auto closing valve stuck
Action required: 705 - Other - as specified
Resolved 5 October 2011
Resolution: replaced valve and cap
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 6 September 2011
Resolved
Pipe supports on port Zdrive hydraulic lines broken
Due 6 October 2011
Resolved 5 October 2011
Resolution: repaired brackets
Communications › Internal Communications System › Sound-powered Telephone
Issued 6 September 2011
Resolved
Sound powered phone bell at aft steering station does not work
Due 6 October 2011
Resolved 5 October 2011
Resolution: Repaired bell
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 6 September 2011
Resolved
Oil leaking from rear of stbd generator prime mover and saturating generator windings
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2011
Resolution: Caterpillar tech rep replaced rear main seal on engine and cleaned generator windings
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 May 2008
Resolved
Renew copies of laminated fire and safety plans stowed on deck.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 5 June 2008
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 20 May 2008
Resolved
Repair or renew glass cover on stbd rudder angle indicator.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 21 May 2008
Communications › Public Address System › Audio Distribution System Silencing
Issued 20 May 2008
Resolved
Install and prove proper operation of public address interrupt for general alarm system.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 5 June 2008
Communications › Internal Communications System › Sound-powered Telephone
Issued 20 May 2008
Resolved
Repair/ renew audible bell on sound-powered phone at the emergency steering system.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 21 May 2008
Deck/Cargo › Holds/Tanks › Coaming
Issued 20 May 2008
Resolved
Adjust door closing device on foward watertight door in engine room.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 21 May 2008
Fire Fighting › Structural - A Class Divisions › Doors
Issued 27 June 2006
Resolved
Repair self-closing device on main deck engine room door.
Condition: Improper/Lack of Maintenance
Due 27 July 2006
Resolved 1 August 2006
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 June 2006
Resolved
Provide 2006 edition Coast Pilot
Condition: Unknown
Due 27 July 2006
Resolved 15 August 2007
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 27 June 2006
Resolved
Provide steering failure alarm. Submit proposal to add to vsl.
Condition: Improper Installation
Due 1 February 2007
Resolved 1 July 2009
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 27 June 2006
Resolved
Provide proper alarm panel for all required alarms in pilothouse (missing alarms for prime movers of generators). Provide proposal for making alteration.
Condition: Improper Installation
Due 1 February 2007
Resolved 1 September 2009
Resolution: Since vessel did not add proper alarms, manning was increased eliminating the need for the alarm.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 27 June 2006
Resolved
Provide 10-man liferaft rigged for eaasy side to side transfer in the event of a loss of the largest raft on either side.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 June 2004
Resolved
Provide proof for batteries being stowed in the 02 level space IAW 46 CFR 129.356.
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 23 June 2004
Resolution: Batteries were removed from a/c room and propely installed in the 01 stack level.
Stability › Watertight Integrity
Issued 28 May 2003
Resolved
Adjust watertight doors in engineroom LEGACY COMPONENT DESC: Watertight doors
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2003
Resolved 28 May 2003
Lifesaving › Lifebuoys
Issued 28 May 2003
Resolved
Provide SOLAS approved retro tape for rescue boat and all liferings. LEGACY COMPONENT DESC: Retro tape
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2003
Resolved 28 May 2003
Lifesaving › Launching Appliances › Davit
Issued 28 May 2003
Resolved
Renew or end-for-end rescue boat davit cable.
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 2 June 2003
Resolution: Davit cable was end-for-ended on 02 June 2003.
Engineering › Compressed Air System (control) › Valve
Issued 28 May 2003
Resolved
Renew relief valve on port air receiver tank.
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 2 June 2003
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 28 May 2003
Resolved
Renew 3 fuel oil hoses on main engines.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2003
Resolved 28 May 2003
Engineering › Fuel Oil Service System › Filter
Issued 15 May 2002
Resolved
PROVIDE AND INSTALL PLUGS IN ALL RACOR FILTER PETCOCKS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 June 2002
Resolved 16 May 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 15 May 2002
Resolved
PROVIDE AND POST FUEL OIL AND LIQUID MUD TRANSFER PROCEDURES. LEGACY COMPONENT DESC: TRANSFER PROCEDURES
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2002
Resolved 16 May 2002
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 May 2002
Resolved
PROVIDE PROPER BRACKETS OXY/ACETALENE CYLINDERS OR REMOVE FROM VESSEL.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2002
Resolved 16 May 2002
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 15 May 2002
Resolved
PROVIDE PROPER LOCATION OR PROOF FOR BATTERIES BEING STORED AND CHARGED IN THE 01 AND 02 LEVEL A/C SPACE. LEGACY COMPONENT DESC: BATTERY STORAGE
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2002
Resolved 23 June 2004
Resolution: Batterie were removed and properly installed in the 01 level space.
Electrical › Electrical Distribution System (emergency)
Issued 15 May 2002
Resolved
RENEW LEAKING BATTERIES IN THE 01 AND 02 LEVEL A/C SPACE. LEGACY COMPONENT DESC: BATTERIES
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2002
Resolved 16 May 2002
Engineering › Bilge Water Management System › Valve
Issued 15 May 2002
Resolved
REPAIR FOREPEAK REACH ROD.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2002
Resolved 15 May 2002
Engineering › Non-conventional Propulsion/Steering
Issued 15 May 2002
Resolved
PROVIDE AND INSTALL CHAFFING GEAR AS DISCUSSED ON PORT Z-DRIVE.
LEGACY COMPONENT DESC: FLEXIBLE HOSE (z-drive)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2002
Resolved 16 May 2002
Engineering › Non-conventional Propulsion/Steering
Issued 15 May 2002
Resolved
RENEW CHAFFED FLEXIBLE HOSE ON PORT Z-DRIVE. LEGACY COMPONENT DESC: FLEXIBLE HOSE (z-drive)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2002
Resolved 16 May 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 15 May 2002
Resolved
PROVIDE AND INSTALL 2 INCH EXTENSION ON END OF THE BRANCH LINE LOCATED IN THE PAINT LOCKER. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 June 2002
Resolved 16 May 2002
Construction/Loadline
Issued 29 May 2001
Resolved
INSTALL FLOODING ALARM IAW 46 CFR 130.400 AND 46 CFR 62. TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 29 May 2001
Resolved 29 May 2001
Deck/Cargo
Issued 24 May 2000
Resolved
Prior to loading cargo into Dry bulk tank #3, ser# 11745V3, provide: approval for repairs, NDT results, Hydrostatic test results and U1R._x001C_ Two 9x12inch holes were cut in tank to accomodate new bearings and pedestals for drive line._x001C_
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000