MAURY USCG vessel records Sign in
← All vessels

SAGE

SAGE is a 1983 industrial vessel. The Coast Guard has recorded 44 inspections since 1987, most recently in March 2008, along with 14 deficiencies and 1 casualty investigation in 2005.

Records from 1987 to 2008. Most recent: inspection, 4 March 2008.

Built
1983
Last inspected
4 March 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8218421 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WBR4900
280172
Flag
VANUATU
368433000 (licence lapsed)
Maury page id
psix-280172

Inspections, by type

…with no type recorded9
Years with a record 19 calendar years (1987–2008)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it297 - Regulatory (Subpart C or D), Gross Ton
744 - Convention (Subpart B), Gross Ton
202 - Regulatory (Subpart C or D), Net Ton
223 - Convention (Subpart B), Net Ton
947 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC4609MMSI 368433000 · cancelled · compulsorily equipped · granted 26 March 2005, cancelled 3 April 2008
WBR4900MMSI not assigned · expired · compulsorily equipped · granted 18 December 1997, cancelled 17 May 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 44

4 March 2008 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3162212
10 October 2007 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3076861
5 June 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2977584
19 September 2006 Type not recorded
No type recorded · USCGC CYPRESS (WLB 210) · USCG Heartland District (CGD-H) · Activity 2784669
15 February 2006 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2585839
20 May 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2363147
6 April 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2327614
28 March 2005 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2321108
15 March 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2311065
1 March 2005 Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2301681
12 January 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2276626
2 December 2004 COI Inspection · Examination of Repairs · Hull Examination · Cargo Tank Internal · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2251935
17 November 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2242884
22 August 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1664493
26 October 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433902
7 August 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 172644
15 May 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1063406
23 April 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1062687
21 July 2000 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401266
6 April 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 21381
15 September 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390606
5 August 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1117982
19 August 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1085014
5 October 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1183383
4 October 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355477
11 July 1995 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358839
28 November 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 45479
17 November 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401951
22 March 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1166172
12 November 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470375
11 March 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 840672
21 December 1992 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410764
21 December 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462322
12 November 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1253821
28 February 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1225318
28 January 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 924315
10 January 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 912159
11 June 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922906
8 November 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225327
17 July 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1196841
12 January 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1210304
6 May 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1345352
19 April 1988 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1032541
10 November 1987 Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1328064

Deficiency record · 14

Engineering › Bilge Water Management System
Issued 22 August 2002 Resolved
Several bilge lights inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2002
Resolution: Light bulbs replaced.
Deck/Cargo › Mooring/Anchoring
Issued 22 August 2002 Resolved
Anchor chain needed to be operated more frequently, or at least adequately lubricated to prevent future inoperability.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2002
Resolution: Chain greased.
Lifesaving › Line-Throwing Appliances › Lines
Issued 22 August 2002 Resolved
One more service line needed.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2002
Resolution: Line found and placed in proper place.
Lifesaving
Issued 15 September 1997 Resolved
PROVIDE MISSING PFD LIGHTS ON LIFEJACKETS.
Condition: Unknown
Due 15 September 1997
Resolved 15 September 1997
Lifesaving
Issued 15 September 1997 Resolved
MISSING DAYLIGHT SIGNALING LAMP (ALDIS LAMP).
Condition: Unknown
Due 15 September 1997
Resolved 15 September 1997
Engineering
Issued 12 November 1993 Resolved
MAKE AVAILABLE FOR INSPECTION THE FOUR DRY BULK RECEIVERS NLT 12DEC93. _x001C_
Condition: Unknown
Due 12 November 1993
Resolved 12 November 1993
Engineering
Issued 28 January 1991 Resolved
REPAIR HOLE IN MAIN ENGINE EXHAUST IN THE PORTSIDE STACK.
Condition: Unknown
Due 28 January 1991
Resolved 28 January 1991
Engineering
Issued 10 November 1987 Resolved
PROVIDE PROOF OF SUBMITTED OF THE FUEL OIL INLINE STRAILER DETAILS TO ABS.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Unknown
Issued 10 November 1987 Resolved
PROVIDE OVER PRESSURE PROTECTION ON THE DISCHARGE SIDE OF THE FIRE MONITOR PUMP AS REQUIRED BY 46 CFR 95.10-5.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Documentation
Issued 10 November 1987 Resolved
AMEND VESSELS CERTIFICATE OF DOCUMENTATION TO REFLECT THE VESSELS NEW NAME (SAGE), PORT OF DOCUMENTATION (NEW ORLEANS, LA), AND NEW OWNER.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Fire Fighting
Issued 10 November 1987 Resolved
PROVIDE PAGE 3 OF 3 OF THE BILGE, BALLAST AND FIRE PIPING BLUEPRINT AS APPROVED BY U.S. COAST GUARD.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Fire Fighting
Issued 10 November 1987 Resolved
PROVIDE U.S. COAST GUARD APPROVED FIRE MAIN SYSTEM BLUEPRINTS.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Electrical
Issued 10 November 1987 Resolved
PROVIDE A LOW VOLTAGE RELEASE FOR THE FIRE PUMP AS REQUIRED BY 46 CFR 111. 70-3(F).
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Unknown
Issued 10 November 1987 Resolved
PROVIDE PROOF OF SUBMITTED OF THE DRY MUD PIPING INTERNAL/EXTERNAL PRESSURECALCULATIONS AND STATIC/DYNAMIC LOADING CALCULATIONS.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987

Casualty record · 1

12 January 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2276626
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.