Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 12 July 2017
Resolved
L/B #2 had a kink on the deluge fire system at the stern of the boat
Condition: Improper/Lack of Maintenance
Due 9 August 2017
Resolved 1 August 2017
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 12 July 2017
No resolution recorded
L/B #2 bottle pressure was low on air.
Condition: Improper/Lack of Maintenance
Due 9 August 2017 — due date passed with no resolution recorded
Stability › Watertight Integrity › General
Issued 12 July 2017
No resolution recorded
Watertight boundaries MCTs were found to be wasted. CG/Class/Flag has agreed that MCTs repair will be done during next drydock and def will be cleared once proof of repair has been provided to CG prior to next drilling ops.
Condition: Improper/Lack of Maintenance
Due 9 August 2017 — due date passed with no resolution recorded
Fire Fighting › Fire Main › Condition
Issued 21 July 2016
Resolved
Multiple leaks found on steel firewater piping and on a valve body gland.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2016
Resolved 3 August 2016
Resolution: Received email from OIM with attached pictures of repair.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 21 July 2016
Resolved
FM200 tank used for protection of the emergency generator space found to be badly corroded. Replace, repair or prove that tank is in working condtion by use of NDT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2016
Resolved 11 August 2016
Resolution: Received email from OIM with accompanying pictures showing that the FM200 tank used for protection of the Emergency Generator space had been replaced.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 21 July 2016
Resolved
Stairwell door at top level found to have 2 through holes in it due to replacement of previous doorknob with a smaller doorknob. Replace/repair to original condition.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 August 2016
Resolved 22 July 2016
Resolution: Received email from OIM with attached pictures of stairwell door repair. Cleared item #3.
Electrical › Electrical Distribution System (service) › Conductor
Issued 21 July 2016
Resolved
Multiple connectors going to "gumbo box connector' in hazardous location found to be fractured, frayed and wasted. Replace connectors to original hazardous location specification.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 22 July 2016
Resolution: Received email from OIM with attached pictures of electical junction box repair. Cleared item #4.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 21 July 2016
Resolved
Several main deck MCTs were found to be wasted and worn causing failed watertight seak required by loadline. Replace/repair MCTs to original condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2016
Resolved 1 September 2016
Resolution: Received email from OIM with accompanying pictures showing that the watertight marine cable transits were repaired to satisfactory conditions.