Records from 1987 to 2021. Most recent: inspection, 20 July 2021.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 36
20 July 2021
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7262188
15 June 2012
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4344624
22 July 2008
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3275804
31 May 2007
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2947294
11 April 2007
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2905684
8 June 2006
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2673748
25 April 2006
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2632806
19 September 2005
Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2496042
22 April 2005
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2340755
5 May 2004
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2059523
29 April 2003
Periodic Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1786715
22 April 2002
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1609712
25 April 2001
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1415595
4 October 2000
Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1405055
24 April 2000
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1420309
22 June 1999
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 761939
15 June 1999
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 194843
26 April 1999
Re-Inspection · Plan Review "T" Boat
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 794083
28 April 1998
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1124372
28 April 1997
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1434552
18 February 1997
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1105298
19 April 1996
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1080000
5 September 1995
Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 876507
30 May 1995
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 872132
17 April 1995
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1417764
18 April 1994
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1353579
20 April 1993
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 841413
20 April 1992
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 955734
15 April 1991
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 916204
21 March 1991
Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1304521
27 September 1990
Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1226592
25 April 1990
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1240285
1 May 1989
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1042711
3 May 1988
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1347466
5 June 1987
Initial Certification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1037805
6 May 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1020652
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 July 2008
Resolved
Provide on board fire extinguishers in current date.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2010
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 23 July 2008
Resolved
Provide on board life jackets and primary lifesaving equipment.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2010
Operations/Management › Drills/Instruction › Fire
Issued 23 July 2008
Resolved
Demonstrate man overboard and fire drill.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2010
Engineering › Bilge Water Management System › Pump
Issued 11 April 2007
Resolved
Repaired installed manual bilge pump.(Pump is in addition to automatic pump and portable hand bilge pump)
Condition: Improper/Lack of Maintenance
Due 2 June 2007
Resolved 31 May 2007
Resolution: Replaced pump diaphragm.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 April 2006
Resolved
Ensure wiring above starboard side of engine is supported by metal hangers every 24".
Due 25 May 2006
Resolved 7 June 2006
Stability › Watertight Integrity › Coaming
Issued 25 April 2006
Resolved
Ensure deck hatches are watertight.
Due 25 May 2006
Resolved 7 June 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 25 April 2006
Resolved
Replace fire extinguisher mount located next to helm.
Due 25 May 2006
Resolved 7 June 2006
Construction/Loadline › Hull › Bracket
Issued 19 September 2005
Resolved
Replace wooden combing that supports storage compartment covers in bow area.
Condition: Improper/Lack of Maintenance
Due 1 May 2006
Resolved 25 April 2006
Resolution: Wooden combing in storage compartment replaced.
Engineering › Steering Gear System › Rudder
Issued 19 September 2005
Resolved
Replace missing rudder post screws in steering compartment.
Condition: Improper/Lack of Maintenance
Due 1 May 2006
Resolved 25 April 2006
Resolution: Rudder post screws replaced.
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 September 2005
Resolved
Sister aft frame supporting the steering compartment hatch due to rot found on the pot side.
Condition: Improper/Lack of Maintenance
Due 1 May 2006
Resolved 25 April 2006
Resolution: Frame sistered. All sat.
Engineering › Bilge Water Management System › Hose
Issued 22 April 2005
Resolved
Raw water wash down hose, 5/5" x 18" in the engine room is severly dry-rotted and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2005
Resolved 11 May 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 22 April 2005
Resolved
Main diesel engine has accumulated rubber dust on the front of the engine due to severly loose alternator belts.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2005
Resolved 11 May 2005
Engineering › Steering Gear System › Linkage
Issued 22 April 2005
Resolved
Need to install a quick release pin for the steering system @ the link, for emergency steering evolutions. Currently there is a bolt in place which would make the emergency tiller set up lenghtly
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2005
Resolved 11 May 2005
Electrical › Electric Supply System (service) › Cable
Issued 22 April 2005
Resolved
Need to install steel wire hangors in the engine room for the new main engine wire harness, which currently is being hung by plastic wire ties.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2005
Resolved 11 May 2005
Engineering › Steering Gear System
Issued 29 April 2003
Resolved
Repair or replace the emergency tiller that is on board. LEGACY COMPONENT DESC: Trick Wheel
Action required: 705 - Other - as specified
Due 29 May 2003
Resolved 27 May 2003
Resolution: Cleared by [name withheld], repaired, braces welded on tiller arm.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 April 2002
Resolved
02 Adult and 03 Child Type I PFD's were replaced due to weather damage.
Due 22 April 2002
Resolved 22 April 2002
Engineering
Issued 28 April 1997
Resolved
Remove petcock from fuel filter and replace with pipe plug to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 5 May 1997
Resolved 4 June 1997
Unknown
Issued 28 April 1997
Resolved
Provide vessel with first aid kit as per 46 CFR 184.710 and 160.041 to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 13 May 1997
Resolved 4 June 1997
Navigation
Issued 28 April 1997
Resolved
Provide emergency radio instruction placard as per 46 CFR 184.506 to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 13 May 1997
Resolved 4 June 1997
Lifesaving
Issued 17 April 1995
Resolved
USING GOOD MARINE PRACTICE, REPAIR OR REPLACE LIFE FLOAT.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Documentation
Issued 15 April 1991
Resolved
PROVIDE ORIGINAL STABILITY LETTER.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Documentation
Issued 15 April 1991
Resolved
PROVIDE GARBAGE PLACARD
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991