Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)56.0 ft × 17.0 ft × 9.0 ft
Registered tonnagegross 57 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYD & MARINE · WESTPORT WA: SEDRO-WOOLLEY WA, UNITED STATES · built 1986
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portWARD COVE, AK
Endorsements, as the file codes themcw_un, fi, reg
DocumentationValid · issued 3 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Simplified, Gross Ton 45 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 20 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 20
1 July 2026Administrative Inspection · Deficiency Check
Any vessel of at least five net tons which engages in coastwise trade, must have a Certificate of Documentation. Provide proof of COD submittal once documentation center is operating.
Action required: 705 - Other - as specified
Resolved 1 July 2026
Resolution: Vessel received the COD from NVDC.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 22 April 2026Resolved
The Master shall determine whether there is any evidence of alcohol use by individuals directly involved in a casualty. Provide 3 valid alcohol test strips.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2026
Resolution: Operator purchased 3 test strips.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 April 2026Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Found EPIRB hydro expired. Replace hydro unit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2026
Resolution: Operator purchased new hydro for epirb.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 April 2026Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. Found swim step railing material unsat. Install additional material equivalent strength to fixed rails.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2026
Resolution: Operator installed satisfactory chain.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 16 April 2020Resolved
Prior to carrying passengers conduct man overboard and fire drill's. 46 CFR 176.808 (g)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2020
Resolved 26 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2019Resolved
A submersible electric bilge pump must have a positive shutoff valve is installed at the hull penetration. The currently installed discharge lines for the submersible pumps do not have a positive shutoff valve at the hull penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 16 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 3 April 2019Resolved
The vessel must have a serviceable life ring. Vessel's life has several cracks allowing water into the buoyancy
foam. Install a new life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 16 May 2019
Construction/Loadline › Hull › Strut/Cross Tie
Issued 11 June 2017Resolved
Make permanent repairs to the vessel’s hull as well as the port propeller shaft and shaft strut. The vessel’s rudder/hull connection must be repair if required. Damage was incurred from a grounding on 11JUN17. The repairs must be approved by the attending USCG Marine Inspector. A repair must be submitted to the MSD Ketchikan for approval.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2017
Resolved 26 June 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 18 May 2016Resolved
Vessel's Radio Safety Certificate is expired. Vessel needs current certificate
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Operations/Management › Vessel Activity › Other
Issued 18 May 2016Resolved
Pose emergency instruction in wheelhouse.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 18 May 2016Resolved
Prove operation of STBD side engine room auto bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 May 2016Resolved
Repair and prove proper operation/method of securing generator room ventilation.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 18 May 2016Resolved
Replace reflective tape on identified lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 May 2016Resolved
Post PFD quantity and location for PFDs stowed in foreard viewing area.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National