Records from 1987 to 1997. Most recent: inspection, 4 April 1997.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 39
4 April 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1093295
2 April 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 401930
2 April 1997
Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1105138
14 November 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 384887
18 March 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 513513
21 February 1995
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1157589
29 November 1994
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 539354
29 November 1994
Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 868203
18 June 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 368043
18 June 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1405582
11 March 1994
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 854908
1 November 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 691836
16 October 1993
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1133327
6 May 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 691837
6 May 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 691838
4 May 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 691835
4 May 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 840962
3 May 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 154098
3 May 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 517796
1 May 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 4110
1 May 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 527009
4 February 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 461447
11 January 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 669455
15 November 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 178876
12 July 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 351970
12 July 1992
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 955338
6 February 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 520021
8 July 1991
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1245955
17 January 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 540873
8 July 1990
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1239385
21 December 1989
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 921857
4 November 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 537581
19 May 1989
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1195616
22 December 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 327519
12 November 1988
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 895861
23 February 1988
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 528179
23 February 1988
Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1024410
11 May 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 316210
11 May 1987
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1023692
Documentation
Issued 14 November 1995
Resolved
HAVE VESSEL RESPONSE PLAN REVIEWED BY REGULATING AUTHORITY TO INCLUDE HOUSTON/GALVESTON CAPTAIN OF THE PORT ZONE PRIOR TO ENTERING THE HOUSTON / GALVESTON AREA AND OR DESIGNATED LIGHTER AREA.
Condition: Unknown
Due 4 April 1997
Resolved 4 April 1997
Deck/Cargo
Issued 29 November 1994
Resolved
Make permanent repairs to starboard vent mast located next to the starboardking post where a tempoary repair now exits._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 November 1994
Resolved 29 November 1994
Deck/Cargo
Issued 29 November 1994
Resolved
Provide and install during cargo transfer operations, mechanical scupper plugs in accordance with 33 CFR 156.120(o)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 November 1994
Resolved 29 November 1994
Documentation
Issued 29 November 1994
Resolved
Provide for review a copy of the vessel's Cargo Ship Safety Construction Certificate's Exemption Certificate._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 November 1994
Resolved 1 December 1994
Electrical
Issued 29 November 1994
Resolved
Provide electrical ground wires and tighten bolts on all explosive proof lighting fixtures in the pumproom, stores and forecastle._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 November 1994
Resolved 29 November 1994
Navigation
Issued 29 November 1994
Resolved
Provide on board an operable ship's bell in accordance with the 72 COLREGS,Rule 33._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 November 1994
Resolved 29 November 1994
Documentation
Issued 29 November 1994
Resolved
Provide for review a copy of DNV's dry dock survey report for the vessel's last dry docking._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 November 1994
Resolved 1 December 1994
Navigation
Issued 18 June 1994
Resolved
PROVIDE A NON-SLIP SURFACE AT THE AUXILIARY STEERING STATION AT THE STEERING GEAR PRIOR TO THE NEXT U.S. VOYAGE.
Condition: Unknown
Due 1 December 1994
Resolved 1 December 1994
Navigation
Issued 18 June 1994
Resolved
CALIBRATE THE PRIMARY RUDDER ANGLE INDICATOR AT THE STEERING GEAR (AUXILIARY STEERING) TO THE BRIDGE PRIOR TO THE NEXT U.S. VOYAGE.
Condition: Unknown
Due 1 December 1994
Resolved 1 December 1994
Lifesaving
Issued 18 June 1994
Resolved
RENEW THE LIFEBOAT PYROTECHNICS (PORT & STARBOARD) PRIOR TO DEPARTURE FROM PORT.
Condition: Unknown
Due 24 June 1994
Resolved 24 June 1994
Electrical
Issued 18 June 1994
Resolved
MAKE THE ELECTRICAL FIXTURES IN THE LOWER CARGO PUMPROOM AND SECOND LEVEL VAPOR TIGHT PRIOR TO CARGO TRANSFER.
Condition: Unknown
Due 24 June 1994
Resolved 24 June 1994
Deck/Cargo
Issued 18 June 1994
Resolved
REPAIR THE RECORDING DEVICE ON THE OIL DISCHARGE MONITOR AND CONTROL SYSTEMPRIOR TO THE NEXT U.S. VOYAGE.
Condition: Unknown
Due 1 December 1994
Resolved 1 December 1994
Deck/Cargo
Issued 16 October 1993
Resolved
PRIOR TO NEXT U.S. PORT, MAKE PERMANENT REPAIRS TO THE #1 IGS BLOWER IMPELLER SHROULD. WHEN OPERATION OF IGS IS REQUIRED ONLY THE #2 AND #3 BLOWERS MAY BE PLACED IN SERVICE.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Deck/Cargo
Issued 16 October 1993
Resolved
PRIOR TO NEXT U.S. PORT, MAKE PERMANENT REPAIRS TO THE SCRUBBER IN WAY OF THE FLUE GAS UPTAKE FLANGE ON THE SCRUBBER TOWER AND THE RUBBER EXPANSION JOINT TO THE IG RETURN LINE.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Deck/Cargo
Issued 16 October 1993
Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE THE MARPOL STANDARD OIL DISCHARGE CONNECTION AS SPECIFIED ON THE VESSEL IOPP CERTIFICATE.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Engineering
Issued 16 October 1993
Resolved
PRIOR TO NEXT U.S. PORT, MAKE PERMANENT REPAIRS TO THE OILY WATER SEPARATORIN WAY OF THE HOLED PIPE CONNECTING THE COALESCER TO THE SEPARATOR. ALL BILGE AND MACHINERY SLOPS MUST REMAIN ON BOARD FOR DISCHARGE TO AN OIL RECEPTION FACILITY IN ACCORDANCE WITH OIL POLLUTION PREVENTION REGULATIONS.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Deck/Cargo
Issued 4 May 1993
Resolved
Prior to return to U.S. waters and prior to any transfer operations within U.S. waters, an examination to the vessel's valves associated with the ballast and cargo system shall be carried out, evaluated and certified by the class society to ensure all are in proper working order.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Deck/Cargo
Issued 12 November 1988
Resolved
PRIOR TO CARGO TRANSFER OPERATIONS, ISOLATE CARGO PIPING FROM INERT GAS PIPING IN THE AREA CROSS CONNECT PIPING.
Condition: Unknown
Due 12 November 1988
Resolved 12 November 1988
Deck/Cargo
Issued 12 November 1988
Resolved
MAKE PERMANENT REPAIRS TO THE CROSS CONNECTION PIPING BETWEEN THE INERT GAS SYSTEM AND THE CARGO PIPING SYSTEM TO THE SATISFACTION OF THE VESSEL'S CLASSIFICATION SOCIETY PRIOR TO THE NEXT U. S. PORT OF CALL.
Condition: Unknown
Due 12 November 1988
Resolved 12 November 1988