MAURY USCG vessel records
← All vessels

BECKY THATCHER

BECKY THATCHER is a 1987 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in June 2024, along with 37 deficiencies.

Records from 2016 to 2024. Most recent: inspection, 17 June 2024.

Built
1987
Last inspected
17 June 2024
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 June 2024
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WTN3171
280624
Flag
UNITED STATES
Maury page id
psix-280624

Documentation record

Registered dimensions (L × B × D)92.0 ft × 30.0 ft × 5.6 ft
Registered tonnagegross 99 / net 84
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERVICE MARINE · AMELIA, LA, UNITED STATES · built 1987
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
84 - Regulatory (Subpart C or D), Net Ton
0 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

17 June 2024 Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7937979
3 April 2024 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7888696
6 September 2023 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7786437
16 May 2023 In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7694131
4 April 2023 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7661842
13 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576481
18 January 2022 In-Service Inspection · DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7381516
6 April 2021 In-Service Inspection · DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7168962
4 December 2020 In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7111566
1 April 2020 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6931765
22 January 2020 In-Service Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6893660
2 April 2019 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6651853
29 August 2018 Internal Structural Exam · Administrative Inspection · Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6489648
4 April 2018 MTSA Verification · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6381248
20 December 2016 COI Inspection · Administrative Inspection · MTSA Verification · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6060380
9 September 2016 Examination of Repairs · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5996442
5 April 2016 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5812546

Deficiency record · 37

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2024 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. MI observed that no guards were in place on generator in engine room. 46 CFR 177.35-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Guards were installed over rotating machinery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2024 Resolved
Exhaust piping shall be gastight throughout its length. Installation of diesel engine exhaust pipe shall be in accordance with 182.15-20. MI observed leak in the exhaust for the stbd engine. 46 CFR 182.15-20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Pine hole leak was welded over.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2024 Resolved
All electrical equipment including motors, generators, controllers, distribution panels, etc. shall be dripproof protected. Dripproof protected means that equipment and machinery is so constructed or protected that its successful operation is not interfered with when subjected to falling moisture or dirt. MI observed portable pump near stbd shaft that was connected via extension cord. 46 CFR 182.15-20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Junction box was installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 April 2024 Resolved
Each EAP education program must include at least the following; display and distribution of a community service hot-line telephone number for crew member assistance. Hotline number is not displayed onboard. 46 CFR 16.401
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Hotline number is posted onboard the vsl.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 April 2024 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the following normally unmanned spaces; A machinery space bilge. High level alarm at operating station is not operable. 46 CFR 119.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2024
Resolved 22 April 2024
Resolution: Electrical wiring fault on bilge high level alarm was fixed, observed audible and visual alarm activation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 April 2023 Resolved
Vessel is overdue for annual servicing of fire extinguishers. Provide evidence of adequate fire fighting equipment servicing prior to commercial operation. 46 CFR 176.810
Action required: 60 - Rectify deficiencies prior to movement
Due 4 April 2023
Resolved 5 April 2023
Resolution: Fire extinguishers were serviced.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 4 April 2023 Resolved
Third deck is missing "299 max persons allowed" placard. Install new placard with "299 max persons allowed" on each access point to third deck. 46 CFR 185.602
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 5 April 2023
Resolution: Signed for max passengers was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 6 April 2021 Resolved
Excessive amounts of oil and debris are to be removed from underneath the port main engine and shaft.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 9 April 2021
Resolution: Received e-mail with photos of clean bilge underneath port main engine.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 April 2021 Resolved
Provide current and corrected charts and coast pilot for navigation area.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 16 April 2021
Resolution: Received photo with new publications onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 April 2021 Resolved
Station bill was not posted at the operating station. Station bill does not lay out vessel specific operations for emergencies such as recovery platform operation, fire pump operation. Submit an updated station bill for review.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 9 April 2021
Resolution: Received amended station bill that is more in line with shipboard specific operations.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 6 April 2021 Resolved
Ammonia inhalants and burn gel are expired in first aid kit. Provide updated equipment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 16 April 2021
Resolution: Received photo of new burn gel and ammonia inhalants.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 April 2021 Resolved
Emergency escape hatch from the engine room was covered with carpet. Markings could not be read to alert passengers and crew to remain clear of the exit. Carpet was removed and the stenciled marking was clearly visible.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 6 April 2021
Resolved 6 April 2021
Resolution: Carpet was removed and stencil was visible on escape hatch cover.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 December 2020 Resolved
A self propelled vessel that is certificated to carry more than 150 passengers shall have an operational Coast Guard type-approved AIS Class A device. Vessel is not outfitted with an approved AIS.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2021
Resolved 18 January 2022
Resolution: AIS is installed and operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 December 2020 Resolved
On passenger decks of vessels engaged in a ferry or excursion type operation, rails shall be at least 42 inches high. Hand rails for ladders going from 2nd deck to 3rd deck measure less than 42 inches at the front edge of the steps. Make height for both port and starboard ladder hand rails a minimum of 42 inches at all points.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2021
Resolved 17 February 2021
Resolution: Rail heights extended to a minimum of 44" at the leading edge of all steps.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 April 2020 Resolved
Main deck port side emergency escape hatch is not labeled "Emergency Escape - Keep Clear". 46 CFR 185.30-15(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2020
Resolved 9 April 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 April 2020 Resolved
Junction box for port main engine starter is no longer watertight. 46 CFR 183.10-20(k)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2020
Resolved 9 April 2020
Navigation › Piloting/Steering › Marine Charts
Issued 4 April 2018 Resolved
Place current chart on board vessel with current notice to mariners. (46CFR181.420)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 12 April 2018
Resolution: Purchased new chart.
Fire Fighting › Fire Hoses › Connections
Issued 4 April 2018 Resolved
Place correct spanner wrench on most forward hose station. (46CFR176.800)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 1 May 2018
Resolution: Purchased proper spanner wrench.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 April 2018 Resolved
Replace stenciling on forward life ring and replace retro-relfective tape. Replace retroi-reflective tape on on stern-top-deck life ring. (
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 1 May 2018
Resolution: Re stenciled life rings and replaced retro.
Communications › Radio Communications › VHF Radiotelephone
Issued 4 April 2018 Resolved
Provide new FCC safety, bridge-to-bridge, do not go more than 1000' from shore until replaced. (47CFR80.59(a)
Action required: 705 - Other - as specified
Resolved 12 April 2018
Resolution: FCC inspector attended and issued new certifcates.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 January 2017 Resolved
Replace outlet cover in galley on 2nd deck. (46CFR 120.200(b)
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 25 January 2017
Resolution: New outlet cover placed.
Engineering › Fuel Oil Service System › Hose
Issued 20 December 2016 Resolved
Replace fuel return lines on port MDE and forward generator, insulation is worn. (46CFR 119.455(b)(2)
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 25 January 2017
Resolution: Replaced both fuel lines in kind.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 December 2016 Resolved
Replace retro on both life rings on 3rd deck. (46CFR 117.70(3)(b)(1)
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 25 January 2017
Resolution: retro properly replaced on both life rings.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 9 September 2016 Resolved
Complete welds in port side watertight bulkhead of forward void. 46 CFR 176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2016
Resolution: Welds completed in port side watertight bulkhead of forward void to the satisfaction of the Marine Inspector.
Construction/Loadline › Structures › Superstructure
Issued 9 September 2016 Resolved
Crop and renew forward port side framing of rub rail. 46 CFR 176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 September 2016
Resolution: Will be reviewed by Marine Inspector in Fort Myers after transit. 835 issued.
Construction/Loadline › Structures › Superstructure
Issued 9 September 2016 Resolved
Provide thickness measurements of port and starboard side prop mounts. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 28 September 2016
Resolution: Submitted and reviewed to the satisfaction of the Marine Inspector.
Construction/Loadline › Penetrations › Weld
Issued 9 September 2016 Resolved
Provide permanent repair to starboard side exhaust. 46 CFR 176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 October 2016
Resolution: Repaired to the satisfaction of the Marine Inspector.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 5 April 2016 Resolved
Provide on board a current FCC radio safety certificate. 47 CFR 80.903
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 15 April 2016
Documentation › Markings/Placards › Capacity Marking
Issued 5 April 2016 Resolved
Provide durable markings for maximum number of passengers for the 3rd deck at the entrance stairwells. 46 CFR 122.602(f)
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 April 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 April 2016 Resolved
Provide on board enough asprin IAW 160.041(b) (100 total) 46 CFR 160.04(b)
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 April 2016
Engineering › Pressure Vessel › Support
Issued 5 April 2016 Resolved
Re-mount hot water heater under galley. 46 CFR 119.320(c)
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 April 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 April 2016 Resolved
Hard wire freezer in compartment under galley. 46 CFR 111.60-13
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 April 2016
Lifesaving › Lifebuoys › Quantity
Issued 5 April 2016 Resolved
Vessel is required 03 ring life buoys. Vessel currently has only 02 on board. Provide on board 01 ring buoy in accordance with 46 CFR 117.70(3)
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 April 2016
Documentation › Markings/Placards › Warning Signs
Issued 5 April 2016 Resolved
Properly label STBD side emergency escape hatch. 46 CFR 116.500
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 April 2016
Stability › Weathertight Integrity › General
Issued 5 April 2016 Resolved
Make both 2nd deck weathertight doors, weathertight prior to credit drydock. 46 CFR 116.1160
Action required: 705 - Other - as specified
Resolved 11 April 2016
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 5 April 2016 Resolved
Label stern with hailing port. 46 CFR 67.123
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 April 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 April 2016 Resolved
Apply non-skid to all exterior decks.
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 15 April 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.