MAURY USCG vessel records Sign in
← All vessels

BECKY THATCHER

BECKY THATCHER is a 1987 passenger vessel (inspected). The Coast Guard has recorded 96 inspections since 1987, most recently in June 2024, along with 461 deficiencies.

Records from 1987 to 2024. Most recent: inspection, 17 June 2024.

Built
1987
Last inspected
17 June 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTN3171
280624
Flag
UNITED STATES
367176480
Maury page id
psix-280624

Inspections, by type

…with no type recorded9
Years with a record 34 calendar years (1987–2024)
The 96 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)92.0 ft × 30.0 ft × 5.6 ft
Registered tonnagegross 99 / net 84
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERVICE MARINE · AMELIA, LA, UNITED STATES · built 1987
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
84 - Regulatory (Subpart C or D), Net Ton
0 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ8564MMSI 367176480 · active · compulsorily equipped · granted 21 March 2026, expires 21 March 2036
WTN3171MMSI 367176480 · cancelled · compulsorily equipped · granted 2 May 2017, cancelled 16 March 2026 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AMERICAN EAGLE Passenger (Inspected) · MISLE 45008 · 4 July 1996 · activity 9040MURPHY'S LAW Passenger (Inspected) · MISLE 370735 · 4 July 1996 · activity 9040

Inspection history · 96

17 June 2024 Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7937979
3 April 2024 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7888696
6 September 2023 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7786437
16 May 2023 In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7694131
4 April 2023 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7661842
13 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576481
18 January 2022 In-Service Inspection · DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7381516
6 April 2021 In-Service Inspection · DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7168962
4 December 2020 In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7111566
1 April 2020 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6931765
22 January 2020 In-Service Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6893660
2 April 2019 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6651853
29 August 2018 Internal Structural Exam · Administrative Inspection · Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6489648
4 April 2018 MTSA Verification · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6381248
20 December 2016 COI Inspection · Administrative Inspection · MTSA Verification · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6060380
9 September 2016 Examination of Repairs · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5996442
5 April 2016 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5812546
9 July 2012 In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4373248
4 January 2012 MTSA Verification · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4217741
10 August 2011 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4111314
10 November 2010 In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3742312
6 October 2010 Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3864317
1 March 2010 MTSA Verification · Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3688013
30 March 2009 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3441160
22 October 2008 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3358855
7 October 2008 Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3340178
3 September 2008 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3315986
10 March 2008 Deficiency Check · Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3109224
17 September 2007 Underwater Inspection in lieu of Drydock · Internal Structural Exam · Drydock Extension
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3056615
3 January 2007 COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2846067
27 March 2006 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2609014
16 February 2006 In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2715975
3 October 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2506476
11 March 2005 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2308028
24 January 2005 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2279641
4 June 2004 MTSA Verification · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2105545
29 March 2004 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2033027
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1980145
28 October 2003 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1937475
16 October 2003 Hull Examination · Internal Structural Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1927853
8 July 2003 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1839814
24 March 2003 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1761828
4 January 2002 Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1476534
26 November 2001 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1460583
2 May 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1065252
26 March 2001 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1418877
28 February 2000 Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1467666
26 October 1999 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1449275
5 March 1999 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1460269
8 January 1999 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1444104
2 March 1998 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1421518
26 November 1997 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1466489
20 October 1997 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1112054
3 March 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1445176
4 July 1996 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 9040
17 June 1996 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1082251
29 May 1996 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 17199
8 January 1996 COI Inspection · Deficiency Check · Drydock Extension
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1442376
14 April 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 857019
21 February 1995 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 855715
8 November 1994 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1173825
28 October 1994 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1183635
12 May 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 858227
24 February 1994 Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 856601
7 December 1993 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1159439
24 February 1993 Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1148735
29 January 1993 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1139576
6 March 1992 Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1316902
5 March 1992 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1007252
18 November 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1261315
31 October 1991 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1003953
16 May 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 911851
11 March 1991 COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1306117
13 December 1990 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 926907
21 November 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 925345
27 October 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 924744
12 July 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 936292
27 June 1990 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1214720
25 May 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 915480
10 May 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1210877
19 March 1990 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1223867
14 February 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 926632
17 January 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 910402
25 May 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1212270
31 March 1989 COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1034214
15 February 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 896564
5 August 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1343081
12 May 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1346896
1 April 1988 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 993126
7 January 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013450
6 January 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317790
10 November 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1314322
21 July 1987 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1331240
21 July 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1334170
16 April 1987 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1027461
31 March 1987 Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1027066

Deficiency record · 461

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2024 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. MI observed that no guards were in place on generator in engine room. 46 CFR 177.35-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Guards were installed over rotating machinery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2024 Resolved
Exhaust piping shall be gastight throughout its length. Installation of diesel engine exhaust pipe shall be in accordance with 182.15-20. MI observed leak in the exhaust for the stbd engine. 46 CFR 182.15-20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Pine hole leak was welded over.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2024 Resolved
All electrical equipment including motors, generators, controllers, distribution panels, etc. shall be dripproof protected. Dripproof protected means that equipment and machinery is so constructed or protected that its successful operation is not interfered with when subjected to falling moisture or dirt. MI observed portable pump near stbd shaft that was connected via extension cord. 46 CFR 182.15-20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Junction box was installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 April 2024 Resolved
Each EAP education program must include at least the following; display and distribution of a community service hot-line telephone number for crew member assistance. Hotline number is not displayed onboard. 46 CFR 16.401
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 22 April 2024
Resolution: Hotline number is posted onboard the vsl.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 April 2024 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the following normally unmanned spaces; A machinery space bilge. High level alarm at operating station is not operable. 46 CFR 119.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2024
Resolved 22 April 2024
Resolution: Electrical wiring fault on bilge high level alarm was fixed, observed audible and visual alarm activation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 April 2023 Resolved
Vessel is overdue for annual servicing of fire extinguishers. Provide evidence of adequate fire fighting equipment servicing prior to commercial operation. 46 CFR 176.810
Action required: 60 - Rectify deficiencies prior to movement
Due 4 April 2023
Resolved 5 April 2023
Resolution: Fire extinguishers were serviced.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 4 April 2023 Resolved
Third deck is missing "299 max persons allowed" placard. Install new placard with "299 max persons allowed" on each access point to third deck. 46 CFR 185.602
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 5 April 2023
Resolution: Signed for max passengers was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 6 April 2021 Resolved
Excessive amounts of oil and debris are to be removed from underneath the port main engine and shaft.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 9 April 2021
Resolution: Received e-mail with photos of clean bilge underneath port main engine.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 April 2021 Resolved
Provide current and corrected charts and coast pilot for navigation area.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 16 April 2021
Resolution: Received photo with new publications onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 April 2021 Resolved
Station bill was not posted at the operating station. Station bill does not lay out vessel specific operations for emergencies such as recovery platform operation, fire pump operation. Submit an updated station bill for review.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 9 April 2021
Resolution: Received amended station bill that is more in line with shipboard specific operations.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 6 April 2021 Resolved
Ammonia inhalants and burn gel are expired in first aid kit. Provide updated equipment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2021
Resolved 16 April 2021
Resolution: Received photo of new burn gel and ammonia inhalants.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 April 2021 Resolved
Emergency escape hatch from the engine room was covered with carpet. Markings could not be read to alert passengers and crew to remain clear of the exit. Carpet was removed and the stenciled marking was clearly visible.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 6 April 2021
Resolved 6 April 2021
Resolution: Carpet was removed and stencil was visible on escape hatch cover.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 December 2020 Resolved
A self propelled vessel that is certificated to carry more than 150 passengers shall have an operational Coast Guard type-approved AIS Class A device. Vessel is not outfitted with an approved AIS.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2021
Resolved 18 January 2022
Resolution: AIS is installed and operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 December 2020 Resolved
On passenger decks of vessels engaged in a ferry or excursion type operation, rails shall be at least 42 inches high. Hand rails for ladders going from 2nd deck to 3rd deck measure less than 42 inches at the front edge of the steps. Make height for both port and starboard ladder hand rails a minimum of 42 inches at all points.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2021
Resolved 17 February 2021
Resolution: Rail heights extended to a minimum of 44" at the leading edge of all steps.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 April 2020 Resolved
Main deck port side emergency escape hatch is not labeled "Emergency Escape - Keep Clear". 46 CFR 185.30-15(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2020
Resolved 9 April 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 April 2020 Resolved
Junction box for port main engine starter is no longer watertight. 46 CFR 183.10-20(k)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2020
Resolved 9 April 2020
Navigation › Piloting/Steering › Marine Charts
Issued 4 April 2018 Resolved
Place current chart on board vessel with current notice to mariners. (46CFR181.420)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 12 April 2018
Resolution: Purchased new chart.
Fire Fighting › Fire Hoses › Connections
Issued 4 April 2018 Resolved
Place correct spanner wrench on most forward hose station. (46CFR176.800)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 1 May 2018
Resolution: Purchased proper spanner wrench.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 April 2018 Resolved
Replace stenciling on forward life ring and replace retro-relfective tape. Replace retroi-reflective tape on on stern-top-deck life ring. (
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 1 May 2018
Resolution: Re stenciled life rings and replaced retro.
Communications › Radio Communications › VHF Radiotelephone
Issued 4 April 2018 Resolved
Provide new FCC safety, bridge-to-bridge, do not go more than 1000' from shore until replaced. (47CFR80.59(a)
Action required: 705 - Other - as specified
Resolved 12 April 2018
Resolution: FCC inspector attended and issued new certifcates.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 January 2017 Resolved
Replace outlet cover in galley on 2nd deck. (46CFR 120.200(b)
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 25 January 2017
Resolution: New outlet cover placed.
Engineering › Fuel Oil Service System › Hose
Issued 20 December 2016 Resolved
Replace fuel return lines on port MDE and forward generator, insulation is worn. (46CFR 119.455(b)(2)
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 25 January 2017
Resolution: Replaced both fuel lines in kind.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 December 2016 Resolved
Replace retro on both life rings on 3rd deck. (46CFR 117.70(3)(b)(1)
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 25 January 2017
Resolution: retro properly replaced on both life rings.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 9 September 2016 Resolved
Complete welds in port side watertight bulkhead of forward void. 46 CFR 176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2016
Resolution: Welds completed in port side watertight bulkhead of forward void to the satisfaction of the Marine Inspector.
Construction/Loadline › Structures › Superstructure
Issued 9 September 2016 Resolved
Crop and renew forward port side framing of rub rail. 46 CFR 176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 September 2016
Resolution: Will be reviewed by Marine Inspector in Fort Myers after transit. 835 issued.
Construction/Loadline › Structures › Superstructure
Issued 9 September 2016 Resolved
Provide thickness measurements of port and starboard side prop mounts. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 28 September 2016
Resolution: Submitted and reviewed to the satisfaction of the Marine Inspector.
Construction/Loadline › Penetrations › Weld
Issued 9 September 2016 Resolved
Provide permanent repair to starboard side exhaust. 46 CFR 176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 October 2016
Resolution: Repaired to the satisfaction of the Marine Inspector.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 5 April 2016 Resolved
Provide on board a current FCC radio safety certificate. 47 CFR 80.903
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 15 April 2016
Documentation › Markings/Placards › Capacity Marking
Issued 5 April 2016 Resolved
Provide durable markings for maximum number of passengers for the 3rd deck at the entrance stairwells. 46 CFR 122.602(f)
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 April 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 April 2016 Resolved
Provide on board enough asprin IAW 160.041(b) (100 total) 46 CFR 160.04(b)
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 April 2016
Engineering › Pressure Vessel › Support
Issued 5 April 2016 Resolved
Re-mount hot water heater under galley. 46 CFR 119.320(c)
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 April 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 April 2016 Resolved
Hard wire freezer in compartment under galley. 46 CFR 111.60-13
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 April 2016
Lifesaving › Lifebuoys › Quantity
Issued 5 April 2016 Resolved
Vessel is required 03 ring life buoys. Vessel currently has only 02 on board. Provide on board 01 ring buoy in accordance with 46 CFR 117.70(3)
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 April 2016
Documentation › Markings/Placards › Warning Signs
Issued 5 April 2016 Resolved
Properly label STBD side emergency escape hatch. 46 CFR 116.500
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 April 2016
Stability › Weathertight Integrity › General
Issued 5 April 2016 Resolved
Make both 2nd deck weathertight doors, weathertight prior to credit drydock. 46 CFR 116.1160
Action required: 705 - Other - as specified
Resolved 11 April 2016
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 5 April 2016 Resolved
Label stern with hailing port. 46 CFR 67.123
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 11 April 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 April 2016 Resolved
Apply non-skid to all exterior decks.
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 15 April 2016
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 4 January 2012 Resolved
Provide records of EAP employee training and EAP supervisory training IAW 46CFR16.401 no later than 11JAN12.
Action required: 705 - Other - as specified
Due 12 January 2012
Resolved 24 January 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 4 January 2012 Resolved
Repair leak from hydraulic hose connection on the aft side of the Port main diesel engine IAW 46CFR115.830(b) prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2012
Resolution: Leak has been secured and new hose has been installed.
Fire Fighting › Nozzles › Number
Issued 4 January 2012 Resolved
Replace missing fire nozzle to engine room fire hose IAW 46CFR181.15-10(d)(2).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2012
Resolution: A new fire nozzle has been provided for the engine room fire hose.
Electrical › Electric Supply System (service) › Cable
Issued 4 January 2012 Resolved
Remove wire nuts in galley and replace with a heat shrink or crimp type connection IAW 46CFR183.05-50(b)(2).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2012
Resolution: A permanent crimp type connection has been installed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 4 January 2012 Resolved
Peramently mount junction box in the galley IAW 46CFR115.830. Junction box was found wire tied to a metal support frame.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2012
Resolution: Junction box has been permanenlty mounted to the frame.
Accommodation/Occupational Safety › Ventilation › General
Issued 4 January 2012 Resolved
Clean and clear galley vent fan and all grease build up behind cooking area IAW 46CFR115.830(b). Area found to have excess grease and dust build up.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 January 2012
Resolved 6 January 2012
Resolution: Area behing the cooking area has been cleaned and freed of grease. The vent fan has been cleaned of dust.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 4 January 2012 Resolved
Permanently mount junction box in refer room IAW 46CFR115.830. Electrical box was found dangling from its wire and not mounted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 January 2012
Resolved 6 January 2012
Resolution: Junction box has been mounted to the bulkhead.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 4 January 2012 Resolved
Make ship start air receivers available for inspection by removing all inspection ports for the attending CG marine inspector IAW 46CFR115.812.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2012
Resolution: Inspection ports have been opened for the inspector.
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 4 January 2012 Resolved
Provide a spanner wrench at each fire fighting station onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2012
Resolution: A spanner wrench has been provided at each fire station.
Engineering › Pressure Vessel › Shell Plate
Issued 4 January 2012 Resolved
Replace as original or hydrostatically test ship start air pressure vessels (two total) IAW 46CFR61.10-5. Severe pitting noted during inspection.
Action required: 705 - Other - as specified
Due 6 February 2012
Resolved 24 January 2012
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Valve
Issued 4 January 2012 Resolved
Replace/ Repair fuel filter and heat shield on PORT main diesel generator IAW 46CFR119.455(b)(5).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 January 2012
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 4 January 2012 Resolved
Replace/ Repair raw water cooling line on STBD side main diesel generator at exhaust IAW 46CFR119.430. Line found leaking and severely corroded prior to using the STBD side generator.
Action required: 705 - Other - as specified
Due 16 January 2012
Resolved 17 January 2012
Operations/Management › Pollution › Control of Discharge of Oil
Issued 4 January 2012 Resolved
Wipe down all excessive oil build up in engine room and make available for inspection IAW 46CFR115.830.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 January 2012
Engineering › Pressure Vessel › Marking and Stamping
Issued 4 January 2012 Resolved
Remove (2) total unfired pressure vessels for water head pressure. Both pressure vessels are not ASME approved IAW 46CFR54.01-5.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2012
Resolution: Both pressure vessels have been removed from the vessel.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Turbocharger
Issued 4 January 2012 Resolved
Replace coolant hose on Port main diesel generator IAW 46CFR182.20-10(b).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2012
Resolution: Coolant hose has been replaced.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Injector (fuel injection)
Issued 4 January 2012 Resolved
Secure fuel oil leaks as ID'd by inspector on the STBD main diesel generator IAW 46CFR115.830(b).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2012
Resolution: Fuel leaks have been secured.
Engineering › Steam Boiler (auxiliary/waste heat) › Mount
Issued 4 January 2012 Resolved
Properly secure hot water heater IAW 46CFR119.320(c). Hot water heater not mounted and showing signs of shifting while underway.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2012
Engineering › Compressed Air System (start air) › Piping
Issued 4 January 2012 Resolved
Replace Port side main diesel engine air shuttle hose IAW 46CFR119.410.
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 17 January 2012
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 4 January 2012 Resolved
Replace nipple on Port side generator on coolant return line IAW 46CFR119.430(d). Found to have excessive corrosion.
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 17 January 2012
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Turbocharger
Issued 4 January 2012 Resolved
Secure oil leak on supply line at turbo IAW 46CFR119.455. Prior to utilizing STBD side generator.
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 17 January 2012
Engineering › Compressed Air System (start air) › Piping
Issued 4 January 2012 Resolved
Replace STBD side MDE air hoses (total two) IAW 46CFR119.410. Hoses found rotted.
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 17 January 2012
Engineering › Compressed Air System (start air) › Piping
Issued 4 January 2012 Resolved
Replace Port side MDE air hose (aft) IAW 46CFR119.410. Hose found to be rotted.
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 17 January 2012
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 4 January 2012 Resolved
Repair exhaust leak on the STBD side generator IAW 46CFR119.430(b).
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 17 January 2012
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 4 January 2012 Resolved
Properly repair generator exhaust line IAW46CFR119.430(d). Exhaust wet line is leaking in the piping located aft of the engine compartment.
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 17 January 2012
Engineering › Bilge Water Management System › Piping
Issued 4 January 2012 Resolved
Properly repair bilge suction/discharge line in the piping located in compartment aft of engine room IAW 46CFR119.510. Pipe found to have "JB WELD" patch on it.
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 17 January 2012
Construction/Loadline › Structures › Deck Plating
Issued 4 January 2012 Resolved
Crop and renew (as original) deck plating on main deck in the life jacket storage area. Repairs must be at least 18" X 18" and approved by a USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 17 January 2012
Construction/Loadline › Structures › Deck Plating
Issued 4 January 2012 Resolved
Crop and renew (as original) deck plating in tool room on main deck. Repairs must be at least 18" X 18" and approved by a USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 11 January 2012
Resolved 17 January 2012
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 December 2010 Resolved
Vsl may not carry passengers starting at midnight on 02Jan11 until all worklist items issued by the Sector St. Pete Office on 27Oct10 are completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2011
Construction/Loadline › Structures › Deck Plating
Issued 28 October 2010 Resolved
Framing under foredeck; brow pin support- Replace flat bar frames by cropping and renewing or installing new frames adjacent to wasted frames.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 14 January 2011
Construction/Loadline › Structures › Deck Plating
Issued 28 October 2010 Resolved
Galley deck- Deterioration, wastage & holed STB side well inboard; crop and insert A-0 boundary.
Action required: 705 - Other - as specified
Due 30 December 2010
Resolved 7 January 2011
Construction/Loadline › Structures › Deck Plating
Issued 28 October 2010 Resolved
Lazarette overhead- Deterioration in PRT & STBD corners under refer flats and female head, also address incomplete welds in old deck inserts.
Action required: 705 - Other - as specified
Due 30 December 2010
Resolved 7 January 2011
Engineering › Steering Gear System › Rudder
Issued 28 October 2010 Resolved
Port & Starboard rudder stops- Temporary repair for return to Ft. Myers and may carry passengers with the temporary rudder stops. Permanent stops shall be installed with repairs made to paddle wheel structure, proposal required if design change.
Action required: 705 - Other - as specified
Due 15 November 2010
Resolved 7 January 2011
Construction/Loadline › Hull › Longitudinal Frame
Issued 28 October 2010 Resolved
False paddle wheel support structure- Crop and renew with like, kind and quality material as new and as designed. Passengers may be carried underway if false paddle wheel is locked in place with wood planks removed as to not cause drag.
Action required: 705 - Other - as specified
Due 30 December 2010
Resolved 7 January 2011
Construction/Loadline › Structures › Superstructure
Issued 28 October 2010 Resolved
Bottom corners of main deck windows (P&S)- Windows to be removed and overhauled as necessary (16 windows).
Action required: 705 - Other - as specified
Due 30 December 2010
Resolved 14 January 2011
Construction/Loadline › Structures › Deck Plating
Issued 28 October 2010 Resolved
Bitt at port side aft of WTD- Repair or replace bitt. Confirm deck in way of bitt is in good condition.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 7 January 2011
Construction/Loadline › Structures › Superstructure
Issued 28 October 2010 Resolved
Remove old boards and framing- on stern of vessel above paddle wheel.
Action required: 705 - Other - as specified
Due 15 November 2010
Resolved 10 November 2010
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 28 October 2010 Resolved
Old pipe for lube oil tank- Repair or remove. Lube oil tank no longer exists.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 20 December 2010
Construction/Loadline › Structures › Deck Plating
Issued 28 October 2010 Resolved
Deck under A/C units, 3rd deck- A/C units deck attachments are broken free. Confirm deck is in good condition prior to reattaching units.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 2 December 2010
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 28 October 2010 Resolved
Stern tube leaks- Owner to provide information on normal leakage for stern tube and packing.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 11 January 2011
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 28 October 2010 Resolved
Main engine leaks- Owner to identify causes of engine oil leaks and repair as necessary.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 14 January 2011
Construction/Loadline › Hull › Longitudinal Frame
Issued 28 October 2010 Resolved
Lazarette frame repair- refasten 1st longitudinal web frame from port side shell to bottom plate; repair crack in lower edge mid frame.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 2 December 2010
Electrical › Electric Supply System (service) › Cable
Issued 28 October 2010 Resolved
Repair/Replace damaged battery cables next to bridge.
Action required: 705 - Other - as specified
Due 7 November 2010
Resolved 10 November 2010
Construction/Loadline › Structures › Deck Plating
Issued 28 October 2010 Resolved
Crop and renew wasted and holed area inside the glass door on 2nd deck (in way of doubler).
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 7 January 2011
Construction/Loadline › Structures › End Bulkhead
Issued 28 October 2010 Resolved
Crop and renew wasted and holed area on exterior bulkhead around 2nd deck glass door.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 22 November 2010
Construction/Loadline › Structures › Deck Plating
Issued 28 October 2010 Resolved
Crop and renew multiple wasted and holed areas in way of the bar counter area on the 2nd deck. Replace A-60 fire protection insulation after repairs.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 3 December 2010
Construction/Loadline › Structures › Deck Plating
Issued 28 October 2010 Resolved
Crop and renew wasted and holed deck/overhead A-0 plating between 1st deck & 2nd deck galleys. Vessel is restricted from using the galley oven/stove while carrying passengers until repairs are complete.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 3 December 2010
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 28 October 2010 Resolved
Repair and properly install the through bulkhead electrical penetration for electric wire located above breaker panel in STBD side galley.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 14 January 2011
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 28 October 2010 Resolved
Reattach electrical junction box located behind the bridge. (Currently attached to a board that is loose).
Action required: 705 - Other - as specified
Due 7 November 2010
Resolved 10 November 2010
Construction/Loadline › Structures › Deck Plating
Issued 28 October 2010 Resolved
Properly repair thin area of wheel house (3rd deck) port side of center seating.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 18 November 2010
Construction/Loadline › Structures › Door
Issued 28 October 2010 Resolved
Provide proposal to replace sliding glass doors that have vinyl coated wood frames with acceptable approved replacements. IAW MSC plan approval letter Ser# H1-60107 dated 8JAN87.
Action required: 705 - Other - as specified
Due 30 December 2010
Resolved 14 January 2011
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 29 March 2010 Resolved
Provide Six Adult Lifejackets
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 12 April 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 March 2010 Resolved
Provide Ammonia Inhalants in First Aid Kit.
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 12 April 2010
Electrical › Lighting (service) › Lighting Fixture
Issued 29 March 2010 Resolved
Starboard Aft Engine Room Missing Light Globe.
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 12 April 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 March 2010 Resolved
Install Machinery Guard on Starboard Forward Engine.
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 12 April 2010
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 March 2010 Resolved
Provide Illumination for Magnetic Compass
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 12 April 2010
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 29 March 2010 Resolved
Replace Fire Control Plan and EEP. Post on all Decks
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 12 April 2010
Navigation › Piloting/Steering › US Coast Pilot
Issued 29 March 2010 Resolved
Provide Current Navigation Publications.
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 12 April 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 March 2010 Resolved
Secure Stair Treads from Main Deck Forward too Second Deck.
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 12 April 2010
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 29 March 2010 Resolved
Provide Designation Letter for Senior Deck Hand.
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 12 April 2010
Lifesaving › Lifebuoys › Serviceable
Issued 1 March 2010 Resolved
Replace Retro-reflective Tape on all Ring Lifebuoys.
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 12 April 2010
Engineering › Generator (propulsion-electric) › Junction Box
Issued 30 March 2009 Resolved
Make operable #2 generator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2009
Resolved 30 April 2009
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 March 2009 Resolved
Replace exhaust lagging on both engines and generators.
Action required: 705 - Other - as specified
Due 13 April 2009
Resolved 13 May 2009
Fire Fighting › Means of Escape › Escape Route Signs
Issued 30 March 2009 Resolved
Properly mark escape hatch 01 deck engine room.
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 13 May 2009
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 30 March 2009 Resolved
Replace buoyant lifeline on ring buoy fwd 03 deck
Action required: 705 - Other - as specified
Due 6 April 2009
Resolved 30 April 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 7 October 2008 Resolved
Repair raw water leaks on the stbd. generator and main engine exhaust mufflers.
Action required: 705 - Other - as specified
Due 21 October 2008
Resolved 22 October 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 7 October 2008 Resolved
Repair raw water leaks on the Port generator exhaust muffler and double clamp the same.
Action required: 705 - Other - as specified
Due 21 October 2008
Resolved 22 October 2008
Engineering › Steering Gear System › Ram
Issued 7 October 2008 Resolved
Renew excessively worn hardware on rudder ram.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2008
Engineering › Steering Gear System › Rudder
Issued 7 October 2008 Resolved
Renew excessively worn hardware on Port and stbd. rudders.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2008
Documentation › Markings/Placards › Capacity Marking
Issued 10 March 2008 Resolved
Re-stencil PFD stowage areas p/s with total.
Condition: Improper/Lack of Maintenance
Due 10 April 2008
Resolved 11 March 2008
Resolution: Re-stenciled.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 10 March 2008 Resolved
Replace galley and 2nd deck bar receptacles with GFI receptacles or replace receptacle breakers w/ GFI breakers.
Due 10 April 2008
Resolved 10 March 2008
Fire Fighting › Fire Main › Condition
Issued 10 March 2008 Resolved
Make proper repairs to fire main piping. The piping has two holes in it.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2008
Resolution: Witnessed operation of fire pump, examined piping and saw a steady stream of water thru hose.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 10 March 2008 Resolved
Seal bulkhead penatration in sewage space.
Action required: 705 - Other - as specified
Due 10 April 2008
Resolved 10 March 2008
Engineering › Bilge Water Management System › Strainer
Issued 10 March 2008 Resolved
Install bilge pipe screen as necessary.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2008
Resolved 11 March 2008
Resolution: Completed.
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Trunking
Issued 10 March 2008 Resolved
Repair dry stores port natural ventilation duct at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2008
Resolved 10 September 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 March 2008 Resolved
Label engine room breaker panel
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2008
Resolved 10 March 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 10 March 2008 Resolved
Provide six Type 1 adult life jackets.
Action required: 705 - Other - as specified
Due 10 April 2008
Resolved 14 March 2008
Resolution: purchased
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 March 2008 Resolved
Replace cover and plugs for junction box in dishroom overhead.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2008
Resolved 10 March 2008
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 10 March 2008 Resolved
Seal bulkhead penetrations in dishroom
Action required: 705 - Other - as specified
Due 10 April 2008
Resolved 11 March 2008
Resolution: Completed.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 March 2008 Resolved
Renew threshold plates for stairway doors.
Action required: 705 - Other - as specified
Due 10 April 2008
Resolved 10 March 2008
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 March 2008 Resolved
Adjust fire control boundary doors to ensure closure and latching.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2008
Resolved 10 March 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 10 March 2008 Resolved
Replace male head 2nd deck, deck penetrations with metallic fitting atleast 12 inches overall.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 April 2008
Resolved 10 March 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 10 March 2008 Resolved
Close or replace light fixture in storage room aft of engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2008
Resolved 11 March 2008
Resolution: Completed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 3 January 2007 Resolved
Secure CO2 cylinder Deck 3 bar.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 January 2007
Resolution: Cleared.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 January 2007 Resolved
Replace faceplate on the electrical outlet Deck 3 bar.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 January 2007
Engineering › Bilge Water Management System › Manifold
Issued 3 January 2007 Resolved
Re-label bilge maifold system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 January 2007
Engineering › Fuel Oil Service System › Piping
Issued 3 January 2007 Resolved
Replace missing cap for bottom of fuel sight glass.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 January 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 3 January 2007 Resolved
Remove all paint/flammables from the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 January 2007
Engineering › Bilge Water Management System › Not Operational
Issued 3 January 2007 Resolved
Demonstrate proper operation of the bilge management system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 January 2007
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 3 January 2007 Resolved
Remove extension cord from the overhead Deck 2 bar.
Action required: 705 - Other - as specified
Due 10 January 2007
Resolved 5 January 2007
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 3 January 2007 Resolved
Re-lable all breakers in the electrical boxes and ensure that all latches are operational.
Action required: 705 - Other - as specified
Due 10 January 2007
Resolved 10 January 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 3 January 2007 Resolved
Re-lable all knife switches.
Action required: 705 - Other - as specified
Due 10 January 2007
Resolved 10 January 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 January 2007 Resolved
Ensure that all lighting throughout the vessel has proper guards.
Action required: 705 - Other - as specified
Due 10 January 2007
Resolved 10 January 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 3 January 2007 Resolved
Remove quick disconnect from the raw water pump / in the interim, wire tie closed to prevent accidental release
Action required: 705 - Other - as specified
Due 10 January 2007
Resolved 10 January 2007
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 3 January 2007 Resolved
Provide proper stowage of the lifejackets deck one aft.
Action required: 705 - Other - as specified
Due 10 January 2007
Resolved 10 January 2007
Stability › Watertight Integrity › General
Issued 3 January 2007 Resolved
Seal all bulkhead penetrations in way of the wiring in the engine room.
Action required: 705 - Other - as specified
Due 10 January 2007
Resolved 10 January 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 January 2007 Resolved
Provide machinery guards for all rotating machinery throughout the vessel
Action required: 705 - Other - as specified
Due 10 January 2007
Resolved 10 January 2007
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 27 March 2006 Resolved
Tighten hand rails both PORT and STBD located in the aft stairwells.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 14 April 2006
Resolution: CLEARED
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 March 2006 Resolved
Refresh/restencil markings on all three (3) ringbuoys.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 14 April 2006
Resolution: CLEARED
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 27 March 2006 Resolved
Make permanent repairs to the 5th stair tread located in FWD stairwell.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 14 April 2006
Resolution: CLEARED
Engineering › Steering Gear System › Hydraulic Hose
Issued 27 March 2006 Resolved
Tighten hydrolic line located under operators console.
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 27 March 2006
Resolution: Cleared
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 27 March 2006 Resolved
Properly lable location with indicator arrows of all fire extinguishers.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 14 April 2006
Resolution: CLEARED
Accommodation/Occupational Safety › Potable Water System › General
Issued 27 March 2006 Resolved
Make permanent repairs to leaking main galley drain.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 14 April 2006
Resolution: CLEARED
Electrical › Electrical Distribution System (service) › Cable
Issued 27 March 2006 Resolved
Remove electrical tape from wiring located in the pantry and repalce with proper connectors.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 14 April 2006
Resolution: CLEARED
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 27 March 2006 Resolved
Remove welding cylinders from tool room adjacent to the pantry.
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 27 March 2006
Resolution: Cleared.
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 March 2006 Resolved
Replace wing nits with hex nut on all battery terminals.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 14 April 2006
Resolution: CLEARED
Construction/Loadline › Hull › Hull Plating
Issued 3 October 2005 Resolved
Make repairs to stbd side shell IWO the aft end of the lazarette, specifically IWO the rub rail connection.
Action required: 705 - Other - as specified
Due 5 November 2005
Resolved 17 October 2005
Fire Fighting › Ventilation Systems › Fans
Issued 3 October 2005 Resolved
Clean dirt and oil from the engine room exhaust fan and blower motor.
Action required: 705 - Other - as specified
Due 5 November 2005
Resolved 17 October 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 January 2005 Resolved
PROVIDE A PROPER BLANK IN OPEN SPACE OF ENGINEROOM ELECTRICAL PANEL.
Due 24 February 2005
Resolved 17 February 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 January 2005 Resolved
REMOVE WING NUTS AND RENEW WITH PROPER HEX NUTS IN WAY OF ALL BATTERY TERMINALS IN ENGINEROOM.
Due 24 February 2005
Resolved 17 February 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 January 2005 Resolved
RENEW LINE FOR WATERLIGHT ON RING BOUY WITH PROPER 3-6 FOOT OF NON-KINKING, FLOATING, UV RESISTANT LINE WITH A CORROSION RESISTANT CLIP.
Due 24 February 2005
Resolved 17 February 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 January 2005 Resolved
CORRECTLY SPLICE WIRES UNDER CONTROL CONSOLE.
Due 24 February 2005
Resolved 17 February 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 January 2005 Resolved
RESTOCK FIRST AID KIT WITH CURRENT DATED AND PROPER AMOUNT OF REQUIRED SUPPLIES.
Due 24 February 2005
Resolved 17 February 2005
Fire Fighting › Fire Pumps › Pressure
Issued 24 January 2005 Resolved
RENEW INOP PRESSURE GUAGE ON FIRE PUMP.
Due 24 January 2005
Resolved 24 January 2005
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 24 January 2005 Resolved
ADJUST 2ND DECK DOORS SO SELF CLOSURE DEVICES OPERATE PROPERLY.
Due 24 February 2005
Resolved 17 February 2005
Operations/Management › Drug and Alcohol Testing
Issued 29 March 2004 Resolved
PROVIDE DOCUMENTATION THAT ALL CREW ON THE EMERGENCY BILL ARE ENROLLED IN THE DAPI PROGRAM. LEGACY COMPONENT DESC: Employee Coverage
Due 29 April 2004
Resolved 20 April 2004
Engineering › Sea-water System (primary cooling)
Issued 4 November 2003 Resolved
Repair soft patch on port side engine cooling line. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 November 2003
Resolved 14 November 2003
Resolution: New pipe welded.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 4 November 2003 Resolved
Repair leak on raw water pump for port engine LEGACY COMPONENT DESC: Raw Water Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2003
Resolved 14 November 2003
Resolution: New gasket installed.
Construction/Loadline › Hull
Issued 4 November 2003 Resolved
Provide gaugings of the following areas; forepeak bottom plate starboard side under vent pipe; engine room bottom plate under old bilge suction; port side bottom plate in lazzarette near forward bulkhead. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2003
Resolved 14 November 2003
Resolution: Gaugings taken see activity for results.
Construction/Loadline › Structures
Issued 4 November 2003 Resolved
Crop and renew tripped bracket under foam floatation in void #1.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 November 2003
Resolved 14 November 2003
Resolution: Sat.
Construction/Loadline › Structures
Issued 4 November 2003 Resolved
Crop and renew tripped stiffener in way of foam floatation on aft bulkhead in void #1. LEGACY COMPONENT DESC: Stiffener
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2003
Resolved 14 November 2003
Resolution: Sat.
Construction/Loadline › Structures
Issued 4 November 2003 Resolved
Crop and renew wasted stiffener, portside in lazzarette, just forward of transom. LEGACY COMPONENT DESC: Transverse stiffener
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2003
Resolved 14 November 2003
Resolution: sat.
Engineering › Bilge Water Management System
Issued 28 October 2003 Resolved
Remove PVC piping from main engine room bilge system. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 November 2003
Resolved 14 November 2003
Resolution: New pipe installed that meets regs.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 28 October 2003 Resolved
Repair leaking exhaust pipe starboard side of lazzarette. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2003
Resolved 14 November 2003
Resolution: Sat.
Electrical › Electrical Distribution System (service)
Issued 28 October 2003 Resolved
Properly wire reefer on main deck - hard wire - no splices. LEGACY COMPONENT DESC: Conductor
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 November 2003
Resolved 9 December 2003
Stability
Issued 28 October 2003 Resolved
Verify draft readings in presence of CG Marine Inspector. LEGACY COMPONENT DESC: Excess Gear
Action required: 705 - Other - as specified
Due 8 December 2003
Resolved 9 December 2003
Fire Fighting › Structural Fire Protection - General
Issued 28 October 2003 Resolved
Remove dry-goods and liquor from void #1 and hydraulic room or install CG approved structural fire protection. Stowage not allowed in these areas per MSC letter dated 1987. LEGACY COMPONENT DESC: Accommodation Space Protection
Action required: 705 - Other - as specified
Due 8 December 2003
Resolved 21 April 2004
Construction/Loadline › Structures
Issued 28 October 2003 Resolved
Renew collar under foundation for brow pin. LEGACY COMPONENT DESC: Brow platform
Action required: 705 - Other - as specified
Due 8 December 2003
Resolved 9 December 2003
Construction/Loadline › Hull
Issued 28 October 2003 Resolved
Renew rub rail on port and starboard sides.
Action required: 705 - Other - as specified
Due 8 December 2003
Resolved 9 December 2003
Resolution: Recinded by MSD FT Myers
Stability › Incline Test
Issued 23 October 2003 Resolved
Demonstrate that over the vessel's service life, the vessel's light ship characterisitcs (displacement, trim, center of gravity) has not significantly changed by the addition, removal, or relocation of items which are included as a part of the vessel's light ship.
Condition: Unknown
Due 20 November 2003
Resolved 9 December 2003
Engineering › Bilge Water Management System
Issued 16 October 2003 Resolved
Remove oil and debris from machinery space bilges. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2003
Stability › Watertight Integrity
Issued 16 October 2003 Resolved
Make vessel available to [name withheld] in order for CG to record vessel's draft marks and conditions of tanks. Investigation narrative of ACT#9040 dated July 4, 1996, states that vessel draft exceeded the maximum allowable drafts as listed on the vessel's stability letter. LEGACY COMPONENT DESC: draft marks
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2003
Lifesaving › Lifejacket/PFD (General)
Issued 16 October 2003 Resolved
On Lakes, Bays and sounds route more than 1 nautical mile from land, provide primary lifesaving equipment iaw 46 CFR 117.207(c). LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2003
Resolution: Vessel has exemption when operating less than 1,000 feet from shore in TAMMS zone.
Lifesaving › Lifejacket/PFD (General)
Issued 16 October 2003 Resolved
On a Rivers route in cold water, provide prmary lifesaving equipment iaw 117.208. LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2003
Resolved 14 November 2003
Resolution: Vessel has waiver when operating in TAMMS zone
Lifesaving › Lifejacket/PFD (Type I)
Issued 16 October 2003 Resolved
Remove life jackets from void below the main deck and stow throughout accomodation spaces as required by 46 CFR 117.78. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 December 2003
Resolved 9 December 2003
Engineering
Issued 16 October 2003 Resolved
Renew port and starboard paddle wheel bearings. LEGACY COMPONENT DESC: paddle wheel bearings
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2003
Resolution: Bearings not deemed in need of replacement
Engineering
Issued 16 October 2003 Resolved
Make paddle wheel axle available for inspection. LEGACY COMPONENT DESC: paddle wheel axle
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2003
Resolution: Axle determined to be OK with adequate structure.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 October 2003 Resolved
Renew missing retaining clips on windows. LEGACY COMPONENT DESC: windows
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: New clips were installed.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 October 2003 Resolved
Remove all sealant and gasket materials on tonnage door located on the main deck, fwd. stbd. side. LEGACY COMPONENT DESC: tonnage door
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: Sealant allowed on tonnage door to make it weathertight.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 October 2003 Resolved
Renew vent screen on vent, port side forward of emergency exit. LEGACY COMPONENT DESC: vent screen
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 21 November 2003
Navigation › Piloting/Steering
Issued 16 October 2003 Resolved
Prove proper operation of rudder angle indicator. LEGACY COMPONENT DESC: Rudder angle indicator
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: Vessel not required to have a rudder angle indicator.
Navigation › Piloting/Steering
Issued 16 October 2003 Resolved
Renew port and starboard chains on rudder assembly. LEGACY COMPONENT DESC: Rudder assembly
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: Owner renewed chains.
Accommodation/Occupational Safety › Occupational Safety
Issued 16 October 2003 Resolved
Renew or remove wasted wooden boards on aft house on 01 deck. LEGACY COMPONENT DESC: 01 deck
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: Boards renewed.
Accommodation/Occupational Safety › Ventilation
Issued 16 October 2003 Resolved
Renew vent securing plating on AC vents, port and starboard sides. LEGACY COMPONENT DESC: AC vents
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 20 November 2003
Electrical › Electric Supply System (service)
Issued 16 October 2003 Resolved
Install cap on electrical outlet, stbd side forward at fire station on main deck. LEGACY COMPONENT DESC: outlet
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: It is a phone jack outlet.
Construction/Loadline › Structures
Issued 16 October 2003 Resolved
Renew port side forward door on main deck. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Due 9 December 2003
Resolved 9 December 2003
Construction/Loadline › Structures
Issued 16 October 2003 Resolved
Make all penetrations between main deck and number 1 void comply with A-class fire control boundary requirement of 46 CFR 116.415(a)(2)(ii). LEGACY COMPONENT DESC: End Bulkhead
Condition: Improper Installation
Due 20 November 2003
Resolved 14 November 2003
Resolution: Owner sealed penetrations with Fireshield silicone
Construction/Loadline › Structures
Issued 16 October 2003 Resolved
Make permanent repairs to deck drain in number 1 void where wasted. LEGACY COMPONENT DESC: number 1 void
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: New pipe welded in.
Engineering › Bilge Water Management System
Issued 16 October 2003 Resolved
Make permanent repairs to aft bilge line coming from manifold in ER. LEGACY COMPONENT DESC: Manifold
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: New pipe welded in.
Accommodation/Occupational Safety › Occupational Safety
Issued 16 October 2003 Resolved
Properly mount and stow soda CO2 bottles in number 1 void. LEGACY COMPONENT DESC: soda CO2 bottles
Condition: Improper Installation
Due 20 November 2003
Resolved 14 November 2003
Resolution: Sat.
Accommodation/Occupational Safety › Ventilation
Issued 16 October 2003 Resolved
Install 3 inch ball check valves on all tank vents located on main deck iaw MSC approved plans. LEGACY COMPONENT DESC: ball check valves
Condition: Unknown
Due 20 November 2003
Resolved 9 December 2003
Accommodation/Occupational Safety › Ventilation
Issued 16 October 2003 Resolved
Verify all main deck vents (storerooms, engine room, etc.) are capable of closure and built iaw MSC approved plans. LEGACY COMPONENT DESC: main deck vents
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 9 December 2003
Fire Fighting › Fire Pumps
Issued 16 October 2003 Resolved
Replace cracked fire pump gauge. LEGACY COMPONENT DESC: Arrangement
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: Gauge was actually on sewage pump.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 October 2003 Resolved
Repair soft patch on keel cooler forward of port engine. LEGACY COMPONENT DESC: keel cooler
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: New pipe welded in.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 October 2003 Resolved
Remove belzona from engine room drain holes. LEGACY COMPONENT DESC: E/R drain holes
Condition: Improper Installation
Due 20 November 2003
Resolved 14 November 2003
Resolution: Drain holes were cleaned out and inspected sat.
Electrical › Electric Generation Source (service)
Issued 16 October 2003 Resolved
Secure wet exhaust hoses on generators. LEGACY COMPONENT DESC: exhaust hose on generators
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 20 November 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 October 2003 Resolved
Renew/repair exhaust lagging on all generators and mains between exhaust cooling water inlet and engine exhaust ports. LEGACY COMPONENT DESC: exhaust lagging
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: Exhaust lagging replaced.
Fire Fighting › Structural Fire Protection - General
Issued 16 October 2003 Resolved
Renew missing SFP insulation on aft bulkhead and stbd forward bulkhead of ER. LEGACY COMPONENT DESC: Structural Bulkhead Construction
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: All sat.
Electrical › Lighting (service)
Issued 16 October 2003 Resolved
Renew light switch cover in number 1 void. LEGACY COMPONENT DESC: Switch
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: All sat.
Electrical › Lighting (service)
Issued 16 October 2003 Resolved
Remount centerline globe in E/R. LEGACY COMPONENT DESC: Switch
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: Sat.
Electrical › Electric Generation Source (service)
Issued 16 October 2003 Resolved
Properly mount and wire wet exhaust temperature switches. (Provide evidence that electrical wires are CG approved). LEGACY COMPONENT DESC: Switch
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: These are sensors, wire is sat.
Electrical › Electric Supply System (service)
Issued 16 October 2003 Resolved
Mount transducer wire in number 1 void. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 20 November 2003
Resolved 14 November 2003
Resolution: Sat.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 October 2003 Resolved
Make permanent repairs to deck drain in number 1 void. LEGACY COMPONENT DESC: NO. 1 void
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: Sat.
Electrical › Electrical Distribution System (service)
Issued 16 October 2003 Resolved
Repair electrical outlet/box in number 2 void. LEGACY COMPONENT DESC: electrical outlet box
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: Sat.
Electrical › Electric Supply System (service)
Issued 16 October 2003 Resolved
Remove wing nuts and properly connect batteries. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper Installation
Due 20 November 2003
Resolved 14 November 2003
Resolution: SAt.
Electrical › Electrical Distribution System (service)
Issued 16 October 2003 Resolved
Remove deadend wires coming from main distrbution panel. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 20 November 2003
Resolved 14 November 2003
Resolution: Wires are not live.
Electrical › Electric Supply System (service)
Issued 16 October 2003 Resolved
Repair latch on Panel A circuit breaker. LEGACY COMPONENT DESC: Overcurrent Device
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: Sat.
Electrical › Electric Supply System (service)
Issued 16 October 2003 Resolved
Install proper blank in panel B circuit breaker. LEGACY COMPONENT DESC: Overcurrent Device
Condition: Improper Installation
Due 20 November 2003
Resolved 14 November 2003
Resolution: Sat.
Electrical › Electric Generation Source (service)
Issued 16 October 2003 Resolved
Repair fuel pump leak on #1 generator, hook up fuel supply on #1 generator through Raycor filter. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 9 December 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 October 2003 Resolved
repair tach on starboard engine. LEGACY COMPONENT DESC: tachometer
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 9 December 2003
Accommodation/Occupational Safety › Potable Water System
Issued 16 October 2003 Resolved
Properly mount covers over heating elements on hot water heater. LEGACY COMPONENT DESC: hot water heater
Condition: Improper Installation
Due 20 November 2003
Resolved 14 November 2003
Resolution: Sat.
Electrical › Electric Generation Source (service)
Issued 16 October 2003 Resolved
Remove dead end wires on #1 generator. LEGACY COMPONENT DESC: Generator Cable
Condition: Improper Installation
Due 20 November 2003
Resolved 9 December 2003
Electrical › Electric Generation Source (service)
Issued 16 October 2003 Resolved
Repair soft patch on port generator exhaust in hydraulic room. LEGACY COMPONENT DESC: Generator
Condition: Improper Installation
Due 20 November 2003
Resolved 14 November 2003
Resolution: New pipe welded in.
Electrical › Electric Generation Source (service)
Issued 16 October 2003 Resolved
Repair leak on stbd generator exhaust in hydraulic room. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: Sat.
Electrical › Electric Generation Source (service)
Issued 16 October 2003 Resolved
Properly secure exhaust to hangars in hydraulic room. LEGACY COMPONENT DESC: Generator
Condition: Improper Installation
Due 20 November 2003
Resolved 14 November 2003
Resolution: Sat.
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 16 October 2003 Resolved
Repair soft patch on A/C drain on port side. LEGACY COMPONENT DESC: A/C drain
Condition: Improper Installation
Due 20 November 2003
Resolved 14 November 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 16 October 2003 Resolved
Install sea rails on grill. LEGACY COMPONENT DESC: sea rails on grill
Condition: Design Flaw
Due 20 November 2003
Resolved 14 November 2003
Electrical › Electrical Distribution System (service)
Issued 16 October 2003 Resolved
Remove extension cord in galley that is used to connect exhaust temp sensor to alarm in galley. Properly wire the same. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 20 November 2003
Resolved 14 November 2003
Resolution: sat.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 16 October 2003 Resolved
Secure CO2 bottle in stbd. closet over hydraulic room. LEGACY COMPONENT DESC: Location
Condition: Improper Installation
Due 20 November 2003
Resolved 14 November 2003
Resolution: Sat, bottle was removed.
Accommodation/Occupational Safety › Occupational Safety
Issued 16 October 2003 Resolved
Repair hole in deck over hydraulic room on port side. LEGACY COMPONENT DESC: hole in deck
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 14 November 2003
Resolution: New deck plate welded.
Engineering › Bilge Water Management System
Issued 16 October 2003 Resolved
Renew bilge piping in lazarrette on fwd bulkhead at bhd penetration. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 9 December 2003
Electrical › Electric Supply System (service)
Issued 16 October 2003 Resolved
Properly install shore tie connection. LEGACY COMPONENT DESC: shore tie connection
Condition: Improper Installation
Due 20 November 2003
Resolved 14 November 2003
Resolution: New shore tie installed.
Engineering › Steering Gear System
Issued 24 March 2003 Resolved
Properly secure steering system hoses to stern bulkhead exterior. LEGACY COMPONENT DESC: Hydraulic Hose
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 March 2003 Resolved
Provide original Certificate Of Documentation onboard vessel.
Due 25 March 2003
Resolved 25 March 2003
Navigation › Piloting/Steering
Issued 24 March 2003 Resolved
Provide a US Coast Pilot book onboard vessel. LEGACY COMPONENT DESC: US Coast Pilot
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Navigation › Piloting/Steering
Issued 24 March 2003 Resolved
Provide a Light List onboard vessel. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 24 March 2003 Resolved
Renew fractured starboard aft bridge window.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 24 March 2003 Resolved
Provide placard to mark location of B-II portable extinguisher under pilothouse. LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Engineering › Sea-water System (primary cooling)
Issued 24 March 2003 Resolved
Repair loss of exhaust cooling water sensor on port main engine. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 25 June 2003
Resolution: Sensor replaced.
Accommodation/Occupational Safety › Occupational Safety
Issued 24 March 2003 Resolved
Provide "Exit" placards for 2nd deck aft stairwell doors.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Communications › Alarms/Indicators
Issued 24 March 2003 Resolved
Porvide a proper audible/visible bilge alarm at the operating station. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Engineering › Bilge Water Management System
Issued 24 March 2003 Resolved
Clean bilges under port/starboard main engines.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Electrical › Electric Supply System (service)
Issued 24 March 2003 Resolved
Remove portable battery charger from aft bulkhead engineroom. LEGACY COMPONENT DESC: Battery Charger
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Lifesaving › Lifejacket/PFD (General)
Issued 24 March 2003 Resolved
Provide retroreflective tape for the 7 noted PFD's. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 24 March 2003 Resolved
Repair torn expanded metal in way of bow ramp access gate. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 June 2003
Resolution: Metal repaired.
Fire Fighting › Structural Fire Protection - General
Issued 24 March 2003 Resolved
Remove tape/make all fire door latches operational. LEGACY COMPONENT DESC: Accommodation Space Protection
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 24 March 2003 Resolved
Properly secure all beverage CO2 bottles throughout vessel.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Fire Fighting › Ventilation Systems
Issued 24 March 2003 Resolved
Service all ventilation closures for engineroom and void spaces and demonstrate proper operation. LEGACY COMPONENT DESC: Duct Hatches
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 24 March 2003 Resolved
Remove paint and combustables from dry storage void.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2003
Resolved 24 March 2003
Fire Fighting › Ventilation Systems
Issued 24 March 2003 Resolved
Degrease ventilation ducts in engineroom. LEGACY COMPONENT DESC: Ducts
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Engineering › Sea-water System (primary cooling)
Issued 24 March 2003 Resolved
Properly install correct metallic piping and properly support same in way of exhaust cooling system or remove same and restore exhaust system to its original dry exhaust configuration and install appropriate lagging. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 June 2003
Resolution: Installed
Engineering › Freshwater Generation System
Issued 24 March 2003 Resolved
Properly support potable water pumps in engineroom.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Engineering › Shafting/Propeller Arrangements
Issued 24 March 2003 Resolved
Re-pack starboard shaft packing gland. LEGACY COMPONENT DESC: Stern Gland
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 24 March 2003 Resolved
Hardwire all freezers and reefers on vessel- extension cords cannot be utilized. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 June 2003
Resolution: Completed
Accommodation/Occupational Safety › Potable Water System
Issued 24 March 2003 Resolved
Secure cap for potable water tank fill.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Fire Fighting › Structural Fire Protection - General
Issued 24 March 2003 Resolved
Remove flammable wall in way of main deck galley starboard side and configure area in accordance with the structural fire protection plan.
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 9 April 2003
Fire Fighting › Structural Fire Protection - General
Issued 24 March 2003 Resolved
Remove flammable bar located forward of 2nd deck dishwashing space and configure area in accordance with the structural fire protection plan.
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 June 2003
Resolution: Removed
Electrical › Electrical Distribution System (service)
Issued 24 March 2003 Resolved
Remove or renew exposed wire on transformer located aft of center generator. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Documentation › Safety/Response Plans/Programs
Issued 24 March 2003 Resolved
Provide updated emergency evacuation plan and include same info on a posted Fire Control Plan.
Action required: 705 - Other - as specified
Due 10 April 2003
Resolved 9 April 2003
Operations/Management › Drug and Alcohol Testing
Issued 8 January 2002 Resolved
Provide EAP training for crew and keep records of who participated in training. LEGACY COMPONENT DESC: EAP Training Requirements
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Resolution: Log is being kept and training material is now available.
Engineering › Bilge Water Management System
Issued 8 January 2002 Resolved
Replace PVC bilge piping in engine room with metallic piping or show that existing piping is what is shown on original approved plans. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Resolution: Piping was removed. Captain stated that piping was just to get better drainage from port and Stbd sides of engines.
Engineering › Bilge Water Management System
Issued 8 January 2002 Resolved
In aft void repair/replace bilge suction pipe and provide strainer for pipe. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Resolution: New check valve, pipe, and strainer were installed.
Electrical › Electric Supply System (service)
Issued 8 January 2002 Resolved
Replace automotive battery charger in engine room with marine type charger. LEGACY COMPONENT DESC: Battery Charger
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Resolution: Charger removed entirely. Engines are air start and battery charging for generator batteries is achieved by main engine alternators.
Engineering › Diesel Engine (auxiliary)
Issued 8 January 2002 Resolved
Replace flexible hose for generator intake cooling with metallic piping . Generator is a vital system due to primary source of power for fire pump. LEGACY COMPONENT DESC: Waste Heat Recovery
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Resolution: ACID determined that hose could remain. Hose was for cooling of exaust only and engine temp would not be affected by loss of this cooling hose.
Documentation › Logs/Records
Issued 4 January 2002 Resolved
Log specifics of drills conducted. LEGACY COMPONENT DESC: Logbook (official)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 4 January 2002
Documentation › Logs/Records
Issued 4 January 2002 Resolved
Log specific required lifesaving inspection results. LEGACY COMPONENT DESC: Logbook (official)
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Navigation › Piloting/Steering
Issued 4 January 2002 Resolved
Provide updated chart of area. LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Navigation › Piloting/Steering
Issued 4 January 2002 Resolved
Provide Coast Pilot LEGACY COMPONENT DESC: US Coast Pilot
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 9 April 2003
Navigation › Piloting/Steering
Issued 4 January 2002 Resolved
Provide deviation table LEGACY COMPONENT DESC: Deviation Table/Graph
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Fire Fighting › Structural Fire Protection - General
Issued 4 January 2002 Resolved
Replace missing insulation in overhead fire control boundry (1ST AND 2ND DECKS) LEGACY COMPONENT DESC: Accommodation Space Protection
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Fire Fighting › Structural Fire Protection - General
Issued 4 January 2002 Resolved
Plug all fire control boundry penetrations with approved filler. LEGACY COMPONENT DESC: Accommodation Space Protection
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 4 January 2002 Resolved
Re-weld chain guard fwd bow rail where it attaches to superstructure. LEGACY COMPONENT DESC: Lifeline
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Fire Fighting › Structural - A Class Divisions
Issued 4 January 2002 Resolved
Ensure door to womens head on main deck properly closes and repair/replace hatch. LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Fire Fighting › Structural - A Class Divisions
Issued 4 January 2002 Resolved
Install all fire doors per original plans. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 February 2002
Resolved 11 February 2002
Fire Fighting › Structural - A Class Divisions
Issued 4 January 2002 Resolved
Provide self closures for all fire doors. LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 9 April 2003
Fire Fighting › Combustible Materials
Issued 4 January 2002 Resolved
Re-evaluate fire load or remove wood bulkhead/partitions on 1st and 2nd deck. LEGACY COMPONENT DESC: Partial Bulkheads/Decks
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Resolution: Wood framing was removed vice re-evaluating fire load
Operations/Management › Vessel Safety Management
Issued 4 January 2002 Resolved
Provide updated emergency evacuation plan in pamphlet form. LEGACY COMPONENT DESC: Emergency Preparedness
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 9 April 2003
Accommodation/Occupational Safety › Ventilation
Issued 4 January 2002 Resolved
Provide secondary means of ventilation shut down. Secondary means must be located outside of the galley. Repair/replace main control switch of ventilation shut down in the galley.
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Resolution: Inspector tested both means. Secondary means of shutdown is located on exterior weather deck, main deck which is where it was shown to have been located per original plans.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 4 January 2002 Resolved
Provide annual service report for servicing of portable fire extinguishers LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Documentation › Safety/Response Plans/Programs
Issued 4 January 2002 Resolved
Post fire control plan LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 9 April 2003
Fire Fighting › Miscellaneous Items
Issued 4 January 2002 Resolved
Seal wire run penetrations in aft engine room bulkhead. LEGACY COMPONENT DESC: A Class Division Penetrations
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Fire Fighting › Miscellaneous Items
Issued 4 January 2002 Resolved
Replace missing insulation on aft engine room bulkhead. LEGACY COMPONENT DESC: Insulation (Penetration of Oil/Oil Vapors)
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Engineering › Bilge Water Management System
Issued 4 January 2002 Resolved
Remove debris from bilge in engine room. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Engineering › Pressure Vessel
Issued 4 January 2002 Resolved
Provide relief valve on port air receiver LEGACY COMPONENT DESC: Relief Valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Electrical › Electrical Distribution System (service)
Issued 4 January 2002 Resolved
Provide means of hard wiring freezer in void aft of engine room. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Resolution: Extention cord was removed. Amother outlet was installed next to freezer.
Electrical › Electric Supply System (service)
Issued 4 January 2002 Resolved
Provide cover for battery in engine room. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Electrical › Electrical Distribution System (service)
Issued 4 January 2002 Resolved
Provide adaquate support for wire run in forward stbd section of engine room. Must be supported at least every 24". LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Electrical › Electrical Distribution System (service)
Issued 4 January 2002 Resolved
properly secure junction box located in main deck galley overhead. LEGACY COMPONENT DESC: Junction Box
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Electrical › Electrical Distribution System (service)
Issued 4 January 2002 Resolved
Provide means of making outlet located in main deck fwd bar, under sink drip proof or install GFI outlet. LEGACY COMPONENT DESC: Outlet Box
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Electrical › Lighting (emergency)
Issued 4 January 2002 Resolved
Provide two flashlights. One for pilot house and second for engine room. LEGACY COMPONENT DESC: Battery Operated Lantern
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Electrical › Electrical Distribution System (service)
Issued 4 January 2002 Resolved
Properly wire ice machine on 3rd deck. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Electrical › Electric Supply System (service)
Issued 4 January 2002 Resolved
Properly attach wires to transformer in engine room. LEGACY COMPONENT DESC: Transformer
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Electrical › Electrical Distribution System (service)
Issued 4 January 2002 Resolved
Properly attach wires for freezer on 1st deck and main deck fwd bar. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Electrical › Lighting (service)
Issued 4 January 2002 Resolved
Re-wire forward spot light on fwd boom. Use approved marine wire for fixed installation or remove fixture and associated wiring. LEGACY COMPONENT DESC: Lighting Feeder
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Resolution: Light & associated wiring were removed.
Lifesaving › Lifejacket/PFD (Type I)
Issued 4 January 2002 Resolved
Stencil life jacket storage containers to indicate quantity and type stowed. LEGACY COMPONENT DESC: Storage
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Operations/Management › Drug and Alcohol Testing
Issued 4 January 2002 Resolved
Provide proof of availibility to have alcohol testing conducted if marine casualty occurs. LEGACY COMPONENT DESC: Testing, Serious Marine Incident
Action required: 705 - Other - as specified
Due 5 February 2002
Resolved 11 February 2002
Resolution: Letter from Drug Testing Consultants was presented to attending inspector.
Construction/Loadline
Issued 26 November 2001 Resolved
CROP AND INSERT PLATE INWAY OF HOLES LOCATED IN LAZARETTE OVERHEAD; PRT SIDE FWD CORNER, 62" FROM STBD SIDE AT TRANSOM, DIESEL EXHAUST PLATE PRT AND STBD, HYDRAULIC PIPE THROUGH CONNECTIONS, PRT SIDE BETWEEN FRAMES 1&2 IN OVERHEAD.
Condition: Unknown
Due 11 February 2002
Resolved 11 February 2002
Electrical
Issued 26 November 2001 Resolved
REPAIR AND PROPERLY MOUNT WATERTIGHT RECEPTICLE IN VOID NUMBER 3.
Condition: Unknown
Due 11 February 2002
Resolved 11 February 2002
Construction/Loadline
Issued 26 November 2001 Resolved
PROPERLY PLUG OR REMOVE DECK DRAINS IN REFER SPACE ON STBD SIDE MAIN DECK. DRAINS ARE PRESENTLY FILLED WITH SOME TYPE OF FOAM.
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Lifesaving
Issued 26 November 2001 Resolved
REMOVE ALL OIL AND DEBRI (ABSORBENT RAGS) FROM MACHINERY SPACE BILGES. IN PRESENT STATE BILGE PUMPING WOULD BE RENDERED UNUSABLE DUE TO CLOGGED SUCTION PIPE FROM DEBRI.
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Electrical
Issued 26 November 2001 Resolved
PROVIDE AND PROPERLY INSTALL A UL MARINE APPROVED FOR WET LOCATIONS BATTERYCHARGER. UNITS IS TO BE PROPERLY HARDWIRED AND MOUNTED.
Condition: Unknown
Due 15 December 2001
Resolved 11 February 2002
Resolution: Battery charger was removed entirely
Construction/Loadline
Issued 26 November 2001 Resolved
PLUG ABANDONED PIPE/ELECTRICAL FITTINGS ON PORT SIDE LAZARETTE FWD BULKHEAD.
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Construction/Loadline
Issued 26 November 2001 Resolved
CROP AND INSERT SIDE SHELL PLATE WHERE HOLED STBD SIDE JUST FWD AFT BULKHEAD IN VOID NUMBER 2.
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Construction/Loadline
Issued 26 November 2001 Resolved
REPAIR CRACKED FRAMES IN LAZARETTE PORT AND STBD SIDE AFT AREA APP. 62" FROM SIDE SHELL AS MARKED BY CG INSPECTOR.
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Electrical
Issued 26 November 2001 Resolved
REMOVE ALL ABANDONED CABLE FROM LAZARETTE, APPEARS TO BE FOR PADDLE WHEEL MOTORS THAT HAVE BEEN REMOVED.
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Electrical
Issued 26 November 2001 Resolved
REPLACE GLOBE ON LIGHT FIXTURE IN VOID NUMBER 4(FUEL TANK SPACE)
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Construction/Loadline
Issued 26 November 2001 Resolved
CROP AND INSERT NEW PLATE IN DECK HOUSE WHERE HOLED ON PORT AND STBD SIDE JUST FORWARD OF TRANSOM.
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Construction/Loadline
Issued 26 November 2001 Resolved
REMOVE ALL STORES FROM VOID NUMBER 3 INCLUDING BUT NOT LIMITED TO PAINT ANDFLAMABLES, TO ALLOW ACCESS TO VESSELS HULL.
Condition: Unknown
Due 11 February 2002
Resolved 11 February 2002
Construction/Loadline
Issued 26 November 2001 Resolved
CROP AND INSERT NEW PLATE WHERE CORRODED IN TRANSOM APPROXIMATELY 18 INCH BY 30 FEET.
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Lifesaving
Issued 26 March 2001 Resolved
PROVIDE CREW TO CONDUCT U/W DRILLS IAW STATION BILL. SEE MINS FOR DETAILS.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Lifesaving
Issued 26 March 2001 Resolved
OBTAIN 2 ADULT LIFEJACKETS. TOTAL PERSONS LIMITED TO 618 UNTIL THEY ARE OBTAINED.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Accommodation/Occupational Safety
Issued 26 March 2001 Resolved
CLEAN GREASE FROM GRIDDLE VENTILATION SYSTEM. SEE MINS FOR DETAILS.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Lifesaving
Issued 26 March 2001 Resolved
PROVIDE PRIMARY LIFESAVING EQUIPMENT. VESSEL LIMITED TO NOT MORE THAN ONE MILE FROM SHORE UNTIL OBTAINED. SEE MINS FOR DETAILS.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Electrical
Issued 26 March 2001 Resolved
INSTALL GLOBE ON LIGHT IN DRY STORES.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Construction/Loadline
Issued 26 March 2001 Resolved
REMOVE OIL ABSORBANT DIAPERS FROM BILGE AREAS. SEE MINS FOR DETAILS.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Engineering
Issued 26 March 2001 Resolved
REPLACE LAGGING ON ENGINE EXHAUST.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Construction/Loadline
Issued 26 March 2001 Resolved
CAP HOLE BETWEEN BULKHEAD FOR MACHINERY SPACE AND DRY STORES.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Electrical
Issued 26 March 2001 Resolved
PROPERLY INSTALL BATTERY CHARGER IN MACHINERY SPACE. SEE MINS FOR DETAILS.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Engineering
Issued 26 March 2001 Resolved
REPLACE HYDRAULIC HOSE ON PORT MAIN ENGINE POWER TAKE-OFF.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Fire Fighting
Issued 26 March 2001 Resolved
PROVIDE SPECIFICATIONS FOR FIRE NOZZLE IN MACHINERY SPACE.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Construction/Loadline
Issued 26 March 2001 Resolved
RECONNECT PIPE FOR BILGE SUCTION FORWARD OF COLLISION BULKHEAD OR PROVIDE HAND PORTABLE OR OTHER EQUIPMENT IAW 46CFR182.510
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Electrical
Issued 28 February 2000 Resolved
PROPERLY MOUNT AND INSTALL GLOBES ON LIGHTING IN THE MACHINERY SPACE, CANNED GOODS VOID, AND LAZARETTE.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Electrical
Issued 28 February 2000 Resolved
THROUGH-OUT THE MACHINERY SPACE MAKE PROPER WIRE CONNECTIONS AND USE METAL TIES TO KEEP WIRING OUT OF BILGE.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Electrical
Issued 28 February 2000 Resolved
PROPERLY MOUNT EXHAUST COOLING PUMPS ON PORT AND STARBOARD MAIN ENGINES ANDMAKE PROPER WIRE CONNECTIONS.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Lifesaving
Issued 28 February 2000 Resolved
PROPERLY STOW CO2 BOTTLES FOR SODA DISPENSER.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Construction/Loadline
Issued 28 February 2000 Resolved
CLEAN KNIFE EDGE ON WATERTIGHT DOOR AND CONDUCT CHALK TEST IN PRESENCE OF COAST GUARD MARINE INSPECTOR. THIS DOOR FAILED TWO PREVIOUS TEST DUE TO IMPROPER ADJUSTMENT.
Condition: Unknown
Due 15 May 2000
Resolved 23 June 2000
Lifesaving
Issued 28 February 2000 Resolved
CLEAN ALL OIL OFF DECKS AND FRAMES IN MACHINERY SPACE, REMOVE ALL DEBRI FROM DECKS (OIL DIAPERS).
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Electrical
Issued 28 February 2000 Resolved
PROPERLY HARDWIRE COFFEPOTS WITH AN APPROVED STRANDED WIRE VICE SOLID CORE HOUSEHOLD WIRING.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Electrical
Issued 28 February 2000 Resolved
PROVIDE ELECTRICAL MATTING AT MAIN SWITCHBOARD.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Electrical
Issued 28 February 2000 Resolved
MAKE RECEPTICLES IN WET LOCATIONS DRIP-PROOF.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Electrical
Issued 28 February 2000 Resolved
PROPERLY HARDWIRE INSTALLED EQUIPMENT THROUGH-OUT THE VESSEL.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Electrical
Issued 28 February 2000 Resolved
REMOVE ALL POWER STRIPS AND PORTABLE CORDS FROM THE VESSEL.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Documentation
Issued 28 February 2000 Resolved
PROVIDE FIRST AID/CPR CARDS FOR 50 PERCENT OF CREW.
Condition: Unknown
Due 15 May 2000
Resolved 23 June 2000
Documentation
Issued 28 February 2000 Resolved
PROVIDE FCC OPERATORS PERMIT FOR EACH MASTER AND COPY OF NEW FCC SAFETY CERTIFICATE UPON RENEWAL.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Engineering
Issued 28 February 2000 Resolved
INSTALL PROTECTIVE GUARDS ON FRONT OF BOTH MAIN PROPULSION ENGINES.
Condition: Unknown
Due 15 May 2000
Resolved 23 June 2000
Lifesaving
Issued 28 February 2000 Resolved
PROVIDE FULL CREW AND CONDUCT DRILLS IN PRESENCE OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Navigation
Issued 28 February 2000 Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Lifesaving
Issued 28 February 2000 Resolved
CLEAN GREASE FROM BEHIND GALLEY OVEN AND GRILL.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Accommodation/Occupational Safety
Issued 28 February 2000 Resolved
REPAIR BOTH EMERGENCY EXIT DOORS ON MAIN DECK PORT AND STARBOARD SIDES OF VESSEL.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Accommodation/Occupational Safety
Issued 28 February 2000 Resolved
POST SIGN TO KEEP CLEAR EMERGENCY ESCAPE AND REMOVE TABLE AND CHAIRS AWAY FROM ENGINE ROOM ESCAPE HATCH.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Accommodation/Occupational Safety
Issued 28 February 2000 Resolved
MARK ALL ENTRANCES TO UPPER DECK WITH MAX PERSONS ALLOWED.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Lifesaving
Issued 28 February 2000 Resolved
PROVIDE PROCEDURE FOR CONDUCTING PASSENGER SAFETY ORIENTATION.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Lifesaving
Issued 28 February 2000 Resolved
PROVIDE AND POST PFD DONNING PLACARDS ON ALL DECKS.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Lifesaving
Issued 28 February 2000 Resolved
MARK VESSEL NAME ON BOTH SIDES OF RING BUOYS.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Lifesaving
Issued 28 February 2000 Resolved
PROVIDE UP TO-DATE FIRST AID KIT IAW 46CFR160.041-4.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Fire Fighting
Issued 28 February 2000 Resolved
PROPERLY MOUNT BII PORTABLE FIRE EXTINGUISHER IN THE MACHINERY SPACE.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Fire Fighting
Issued 28 February 2000 Resolved
PROVIDE CORRECT FIRE NOZZLE FOR THE MACHINERY SPACE.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Lifesaving
Issued 28 February 2000 Resolved
REMOVE FLAMABLE PAINT FROM VESSEL OR STOW IN PROPER LOCKER.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Fire Fighting
Issued 28 February 2000 Resolved
MARK VESSEL NAME ON FIRE AXE.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Lifesaving
Issued 28 February 2000 Resolved
SUBMIT A MAN-OVERBOARD RESCUE PROCEDURE TO MSO TAMPA FOR APPROVAL.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Accommodation/Occupational Safety
Issued 28 February 2000 Resolved
REPLACE WASTE RECEPTICLES THROUGH-OUT THE VESSEL WITH NON-FLAMABLE TYPE.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Construction/Loadline
Issued 28 February 2000 Resolved
INSTALL AND DEMONSTRATE OPERATION OF HIGH BILGE ALARM IN MACHINERY SPACE.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Engineering
Issued 28 February 2000 Resolved
OPEN UP BOTH AIR TANKS IN MACHINERY SPACE FOR INSPECTION.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Electrical
Issued 28 February 2000 Resolved
PROPERLY MOUNT AND INSTALL COVER ON JUNCTION BOX BEHIND OVENS.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Engineering
Issued 28 February 2000 Resolved
REPLACE FUEL HOSE ON PORT MAIN ENGINE AND CHECK SEA WATER HOSES THROUGH-OUTMACHINERY SPACE AND INSTALL DOUBLE HOSE CLAMPS AS NEEDED.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Electrical
Issued 28 February 2000 Resolved
BLOCK BATTERIES TO PREVENT MOVEMENT AND MAKE CONNECTIONS TO TERMINALS WITH PROPER CONNECTORS.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Lifesaving
Issued 28 February 2000 Resolved
REPAIR OIL AND FUEL LEAKS THROUGH-OUT MACHINERY SPACE AND UNDER BRIDGE CONSOLE.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Construction/Loadline
Issued 28 February 2000 Resolved
PROVIDE SUITABLE HAND BILGE PUMP CAPABLE OF REMOVING WATER FROM VOIDS NOT SERVICED BY BILGE SYSTEM.
Condition: Unknown
Due 9 May 2000
Resolved 9 May 2000
Lifesaving
Issued 8 January 1999 Resolved
INSTALL RETRO TAPE ON ALL RING BUOYS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Lifesaving
Issued 8 January 1999 Resolved
RENEW ALL FLARES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Electrical
Issued 8 January 1999 Resolved
SUPPORT ELECTRICAL WIRING IN GALLEY OVERHEAD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Electrical
Issued 8 January 1999 Resolved
CLOSE OPENING IN BREAKER PANEL 2ND DECK AFT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Accommodation/Occupational Safety
Issued 8 January 1999 Resolved
LABEL ENGINE ROOM ESCAPE HATCH "EMERGENCY ESCAPE-KEEP CLEAR"._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Accommodation/Occupational Safety
Issued 8 January 1999 Resolved
CLEAN VENT HOOD IN GALLEY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Lifesaving
Issued 2 March 1998 Resolved
PROVIDE 18 ADULT PFD'S. TOTAL PERSONS REDUCED TO 602 UNTIL COMPLETE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1998
Resolved 28 May 1998
Fire Fighting
Issued 2 March 1998 Resolved
MOUNT GALLEY FIRE EXTINGUISHER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1998
Resolved 28 May 1998
Navigation
Issued 2 March 1998 Resolved
REPAIR/PROVE OPERATION OF POLARIS VHF RADIO._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1998
Resolved 28 May 1998
Fire Fighting
Issued 2 March 1998 Resolved
LABEL FIRE AXE W/VESSEL NAME._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1998
Resolved 28 May 1998
Lifesaving
Issued 2 March 1998 Resolved
INSTALL 3-6' OF LINE ON RING BUOY WATERLIGHT AND A HALYARD CLIP ON END THATATTACHES TO RB. ALSO RENEW 60' ON RING BUOY W/DARK COLORED FLOATING LINE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1998
Resolved 28 May 1998
Navigation
Issued 20 October 1997 Resolved
COMPETE THE FOLLOWING REPAIRS TO THE HYDRAULIC STEERING SYSTEM PRIOR TO THECARRIAGE OF PAX'S: 1. REPAIR FRACTURE TO 18" X 18" INSERT IN STERN HULL PLATING FORWARD OF STEERING UNIT 2. RENEW 2 BOLTS HOLDING STEERING ARMS TO TRIANGULAR PLATE 3. REPAIR FRACTURE TO MOUNTING PLATE BELOW STEERING UNIT.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Electrical
Issued 20 October 1997 Resolved
REPAIR EXHAUST LEAK ON STARBOARD GENERATOR.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Lifesaving
Issued 20 October 1997 Resolved
REMOVE EXCESS OIL FROM ENGINEROOM BILGES AND OPEN DRUM IN AFT STOWAGE COM- PARTMENT.
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Electrical
Issued 20 October 1997 Resolved
PROVIDE CLOSURE DEVICES FOR ELECTRICAL PANELS IN THE ENGINEROOM.
Condition: Unknown
Due 20 October 1997
Resolved 20 October 1997
Electrical
Issued 3 March 1997 Resolved
INSTALL COVER OVER OPENING IN POWER PANEL IN FORWARD PART OF THE ENGINEROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 March 1997
Resolved 12 May 1997
Construction/Loadline
Issued 3 March 1997 Resolved
PROVE OPERATION OF ENGINEROOM WATERTIGHT DOOR OPEN ALARM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 March 1997
Resolved 12 May 1997
Lifesaving
Issued 3 March 1997 Resolved
PROVIDE/POST EMERGENCY EVACUATION PLAN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 March 1997
Resolved 12 May 1997
Fire Fighting
Issued 3 March 1997 Resolved
INSTALL SPANNER WRENCHES ON ALL FIRE STATIONS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 March 1997
Resolved 12 May 1997
Accommodation/Occupational Safety
Issued 3 March 1997 Resolved
LABEL UPPER DECK 396 PERSONS MAXIMUM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 March 1997
Resolved 12 May 1997
Navigation
Issued 17 June 1996 Resolved
VESSEL MAY ONLY OPERATE WHILE ACCOMPANIED BY AN ASSIST TUG (MINIMUM 500HP) UNTIL PERMANENT REPAIRS ARE MADE TO STEERING SYSTEM. ASSIST TUG MUST BE CAPABLE OF RENDERING ASSISTANCE IN NO MORE THAN TWO MINUTES.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Navigation
Issued 17 June 1996 Resolved
MAKE PERMANENT REPAIRS TO STEERING SYSTEM TO SATISFACTION OF ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Construction/Loadline
Issued 8 January 1996 Resolved
CLOSE DECK PENETRATIONS IN LADIES HEAD MAIN DECK.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Electrical
Issued 8 January 1996 Resolved
REMOVE ABONDONED CABLE IN ENGINE ROOM.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Fire Fighting
Issued 8 January 1996 Resolved
MOUNT GALLEY FIRE EXTINGUISHER.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Navigation
Issued 8 January 1996 Resolved
PROVIDE CURRENT EDITIONS OF 46CFR 166-199, COAST PILOT, LIGHT LIST AND CHARTS OF AREA OF OPERATION.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Fire Fighting
Issued 8 January 1996 Resolved
SERVICE ALL FIRE EXTINGUISHER PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Unknown
Issued 8 January 1996 Resolved
CONDUCT CREW DRILLS; FIRE AND MAN OVERBOARD.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Lifesaving
Issued 8 January 1996 Resolved
REPAIR OR REPAINT ALL BUOYANT APPARATUS.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Fire Fighting
Issued 8 January 1996 Resolved
INSTALL METALLIC HOSE NOZZLE ON AFT MAIN DECK HOSE STAION.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Navigation
Issued 8 January 1996 Resolved
RENEW STARBOARD RUNNING LIGHT LENS.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Engineering
Issued 21 February 1995 Resolved
Install insulation on 2 main engine exhaust lines outboard on each main engine.
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Lifesaving
Issued 21 February 1995 Resolved
Repair 2 - 20 person buoyant apparatus and label all w/vessel name and capacity.
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Fire Fighting
Issued 21 February 1995 Resolved
Label fire axe with vessel name.
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Fire Fighting
Issued 21 February 1995 Resolved
Repair engine driven fire pump (prove operation). Vessel may not carry passengers until repaired.
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Construction/Loadline
Issued 21 February 1995 Resolved
Label 2 recently installed valves on bilge manifold.
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Electrical
Issued 21 February 1995 Resolved
Repair and label aft emergency light - second deck.
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Documentation
Issued 21 February 1995 Resolved
Provide FCC Safety Radio Telephony certificate. Vessels route is_x001C_ restricted to not more than 1000 feet from shore until satisfied.
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Electrical
Issued 21 February 1995 Resolved
Install guard on front of #1 generator.
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Lifesaving
Issued 21 February 1995 Resolved
Label all ring buoys with vessel.
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Construction/Loadline
Issued 28 October 1994 Resolved
RENEW PORT AND STBD. DECK SUPPORTS FOR PADDLE WHEEL PLATFORM.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Accommodation/Occupational Safety
Issued 28 October 1994 Resolved
REPLACE BROKEN WINDOWS TO MAIN DECK ACCOMMODATIONS PRIOR TO THE CARRIAGE OFPASSENGERS.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Electrical
Issued 28 October 1994 Resolved
REMOVE DEAD-END WIRING FROM ELECTRICAL PANEL WHICH SERVED PADDLE WHEEL MOTOR.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Lifesaving
Issued 28 October 1994 Resolved
REMOVE OILY WATER & DEBRIS FROM PORT MAIN DIESEL ENGINE BILGE POCKET PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Engineering
Issued 24 February 1994 Resolved
Install lagging on starboard engine exhaust mainfolds.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Engineering
Issued 24 February 1994 Resolved
Repack starboard tailshaft.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Electrical
Issued 24 February 1994 Resolved
Properly wire ice tea machine - main deck.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Lifesaving
Issued 24 February 1994 Resolved
Stencil new buoyant apparatus with vsl name and capacity.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Lifesaving
Issued 24 February 1994 Resolved
Stencil new ring buoy with vessels name.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Lifesaving
Issued 24 February 1994 Resolved
Repair waterlights for new ring buoy and buoyant apparatus.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Engineering
Issued 24 February 1993 Resolved
Open both air receivers for internal exam by USCG inspector.
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Fire Fighting
Issued 24 February 1993 Resolved
Replace one fire hose.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Lifesaving
Issued 24 February 1993 Resolved
Renew hand held signalling devices.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Navigation
Issued 24 February 1993 Resolved
Repair stern light.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Lifesaving
Issued 24 February 1993 Resolved
Provide 3 additional cheld pfd's. Vessel limited to not more than 510 total person until completed.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Fire Fighting
Issued 6 March 1992 Resolved
REPLACE FORE HOSE 2ND DECK, PORT SIDE.
Condition: Unknown
Due 20 March 1992
Resolved 20 March 1992
Documentation
Issued 6 March 1992 Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION_x001C_
Condition: Unknown
Due 20 March 1992
Resolved 20 March 1992
Accommodation/Occupational Safety
Issued 6 March 1992 Resolved
POST GARBAHGE PLACARDS AND PROVIDE GARBAGE MANAGEMENT PLAN.
Condition: Unknown
Due 20 March 1992
Resolved 20 March 1992
Documentation
Issued 6 March 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 20 March 1992
Resolved 20 March 1992
Engineering
Issued 6 March 1992 Resolved
REPAIREMERG. FUEL SHUTOFF.
Condition: Unknown
Due 20 March 1992
Resolved 20 March 1992
Lifesaving
Issued 6 March 1992 Resolved
PROVIDE ONE ADDITIONAL CHILD SIZE PFD.
Condition: Unknown
Due 20 March 1992
Resolved 20 March 1992
Construction/Loadline
Issued 31 October 1991 Resolved
PROPERLY ATTACH BILGE PIPING IN THE ENGINE ROOM.
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Construction/Loadline
Issued 31 October 1991 Resolved
RENEW REACH ROD TO VOID NUMBER ONE (1) BILGE SYSTEM VALVE.
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Electrical
Issued 31 October 1991 Resolved
SUPPLY APPROVED WIRING AND PROPER INSTALLATION FOR 220V HOT WATER HEATER AND 110V BOX REEFERS.
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Fire Fighting
Issued 11 March 1991 Resolved
PROVIDE NOZZLE FOR ER FIRE HOSE.
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Construction/Loadline
Issued 11 March 1991 Resolved
RENEW BELT ON ENGINE DRIVEN BILGE PUMP PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Lifesaving
Issued 11 March 1991 Resolved
STENCIL 39 ADULT AND 4 CHILD PFD'S WITH VESSEL'S NAME.
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Electrical
Issued 21 November 1990 Resolved
REPAIR "SHORETIE POWER AVAILABLE" LIGHT ON THE MAIN SWITCHBOARD.
Condition: Unknown
Due 21 November 1990
Resolved 21 November 1990
Lifesaving
Issued 21 November 1990 Resolved
PROVIDE 39 ADDITIONAL ADULT LIFE PRESERVERS. VESSEL IS LIMITED TO 361 PASSENGERS UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 21 November 1990
Resolved 21 November 1990
Navigation
Issued 27 October 1990 Resolved
DOUBLE NUT AND/OR SECURE BY COTTERPINS ALL TILLER ARMS BOLTS.
Condition: Unknown
Due 27 October 1990
Resolved 27 October 1990
Construction/Loadline
Issued 27 October 1990 Resolved
REPAIR WASTED BUMPER GUARDS
Condition: Unknown
Due 27 October 1990
Resolved 27 October 1990
Electrical
Issued 19 March 1990 Resolved
REMOVE EXTENSION CORDS AND MULTIPLE PRONG ADAPTERS IN THE 1ST DECK BAR (OVERHEAD AND FLOOR), BAND AREAS, 2ND DECK BAR, 2ND DECK GALLEY, 3RD DECK BAR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Engineering
Issued 19 March 1990 Resolved
MAKE BOTH AIR RECEIVERS AVAILABLE FOR INTERNAL INSPECTION BY 3MAR90.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Engineering
Issued 19 March 1990 Resolved
MARK THE REMOTE FUEL SHUTOFF VALVE IAW 46 CFR 185.30-20 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Engineering
Issued 19 March 1990 Resolved
RENEW THE AEROQUIP AE102/624 FIRESLEEVE ON THE PORT MAIN ENGINE FUEL SUPPLYHOSE OR RENEW THE HOSE WITH USCG APPROVED HOSE.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Engineering
Issued 19 March 1990 Resolved
INSTALL PROTECTIVE SHIELD ON BOTH AIR COMPRESSORS.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Electrical
Issued 19 March 1990 Resolved
PROVE OPERATION OF THE "GENERATOR AND SHORETIE PWR AVAILABLE LIGHTS" ON THEMAIN SWITCHBOARD.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Electrical
Issued 19 March 1990 Resolved
SUBMIT ELECTRICAL DWG FOR THE INSTALLATION OF THE FRESH H2O PUMPS, SHOWING LOADS, WIRE TYPE AND SIZE AND FUSE SIZES.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Electrical
Issued 19 March 1990 Resolved
PROPERLY CONNECT FRESH H20 PUMP WIRES (NO WIRE NUTS; SEE 183.05-50(B)(3)).
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Engineering
Issued 19 March 1990 Resolved
REMOVE PLASTIC TUBE SIGHT GLASS FROM DIESEL STORAGE TANK. THE NEW LIQUID LEVEL INDICATOR MUST MEET 46 CFR 182.20-25(A)(5). TO BE COMPLETED PRIOR TOCARRYING PASSENGERS.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Accommodation/Occupational Safety
Issued 19 March 1990 Resolved
REPAIR SEWAGE OVERBOARD LINE IN WAY OF SOFT PATCH IN E/R.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Engineering
Issued 19 March 1990 Resolved
PROVIDE AIR RECEIVER DATA PLATE FOR BOTH RECEIVERS SHOWING THAT THEY ARE DERATED TO 165 PSI.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Fire Fighting
Issued 19 March 1990 Resolved
PROVIDE A FIREAXE.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Electrical
Issued 19 March 1990 Resolved
PERMANENTLY WIRE ENOUGH OUTLETS TO SUPPLY ELECTRICITY FOR ALL DEMANDS. SUBMIT ELECTRICAL DWG ON NEW INST. SHOWING COMPLIANCE WITH 46 CFR PART 183.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Electrical
Issued 19 March 1990 Resolved
REMOVE EXTENSION CORD AND REWIRE REFRIGERATOR IN GALLEY.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Electrical
Issued 19 March 1990 Resolved
PROVIDE BLANK CIRCUIT BREAKER FOR MAIN DECK EQUIPMENT PANEL (PORT SIDE GALLEY).
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Navigation
Issued 19 March 1990 Resolved
REMOVE HYDRAULIC OIL STORED IN WHEELHOUSE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Electrical
Issued 19 March 1990 Resolved
REMOVE OR PERMANENTLY MOUNT AND REWIRE E/R TRANSFORMER.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Electrical
Issued 19 March 1990 Resolved
REMOVE 110V SJ WIRE FOR STEERING SYSTEM IN PILOT HOUSE CONTROL PANEL AND REWIRE IAW 46 CFR 183.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Electrical
Issued 19 March 1990 Resolved
REWIRE FLOOD LIGHT IN ACCORDANCE WITH 46 CFR 183.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Lifesaving
Issued 19 March 1990 Resolved
REPAIR/RENEW AFTER BUOYANT APPARATUS WATERLIGHT BRACKET.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Documentation
Issued 19 March 1990 Resolved
POST STABILITY LETTER IN WHEELHOUSE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Engineering
Issued 17 January 1990 Resolved
REMOVE ALL OIL FROM UNDER THE STBD ENGINE AND SLOW DOWN STUFFING BOX LEAK PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Lifesaving
Issued 17 January 1990 Resolved
RELOATE 2 AFTER BUOYANT APPARATUS TO THE TOP OF THE WHEELHOUSE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Lifesaving
Issued 17 January 1990 Resolved
ATTACH ALL 4 BUOYANT APPARATUS ON TOP OF WHEELHOUSE TO 100' PAINTER W/ 20' LINES. DO NOT FASTEN (TIE) TO BOAT. RAFTS MUST BE "FLOAT FREE". COMPLETE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Lifesaving
Issued 17 January 1990 Resolved
ATTACH WATERLIGHTS TO ALL BUOYANT APPARATUS WITH LANYARDS MEETING 46 CFR 180.15-5(D) (18' LONG) PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Lifesaving
Issued 31 March 1989 Resolved
MAKE UP ALL PENDANT LINES ON BUOYANT APPARATUS INTO HANKS
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Lifesaving
Issued 31 March 1989 Resolved
MARK AND MOUNT TWO ADDITIONAL RING BUOYS ON BOARD.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Fire Fighting
Issued 31 March 1989 Resolved
INSTALL PROPER SIZE PRESSURE GUAGE IN FIRE PUMP OUTLET THAT WILL NOT PEG OUT.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Construction/Loadline
Issued 31 March 1989 Resolved
ADJUST DOGS ON WATERTIGHT DOOR SO THAT ALL MAKE CONTACT WITH WEDGES.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Lifesaving
Issued 31 March 1989 Resolved
PROVIDE 60 FT. OF LINE FOR RING BUOY WITH WATERLIGHT.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Lifesaving
Issued 31 March 1989 Resolved
PROVIDE WATERLIGHTS ON 4 BUOYANT APPARATUS FORWARD.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Electrical
Issued 31 March 1989 Resolved
INSTALL VISUAL INDICATOR LIGHT IN PILOT HOUSE SHOWING STATUS OF WATERTIGHT DOOR IN ENGINE ROOM.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Electrical
Issued 31 March 1989 Resolved
INSTALL NON CONDUCTIVE RUBBER MAT IN FRONT OF SWITCHBOARD IN ENGINE ROOM.
Condition: Unknown
Due 31 March 1989
Resolved 31 March 1989
Documentation
Issued 1 April 1988 Resolved
PROVIDE COMMUNICATION ACT SAFETY RADIO TELEPHONE CERTIFICATE ISSUED BY FCC.UNTIL THIS ITEM IS CORRECTED THE VESSEL SHALL BE LIMITED TO NOT MORE THAN 1000 FEET FROM THE SHORE OPERATION.
Condition: Unknown
Due 1 April 1988
Resolved 1 April 1988
Engineering
Issued 1 April 1988 Resolved
PROVE PROPER OPERATION OF EMERGENCY FUEL OIL SHUT-OFF VALVE. CORRECT NOT LATER THAN 15APR88.
Condition: Unknown
Due 1 April 1988
Resolved 1 April 1988
Electrical
Issued 1 April 1988 Resolved
REMOVE "ROMEX" TYPE WIRING INSTALLED IN HOT WATER HEATER (2ND DECK) AND WIRING LIGHT TO ENTRANCE TO E/R (MAIN DECK). REPLACE WITH SHIPBOARD TYPE APPROVED FOR MARINE USE CABLE. CORRECT NLT 15APR88.
Condition: Unknown
Due 1 April 1988
Resolved 1 April 1988
Lifesaving
Issued 1 April 1988 Resolved
CONNECT BUOYANT APPARATUS TO THE VESSEL WITH FLOAT-FREE LINK. CORRECT NLT 15APR88.
Condition: Unknown
Due 1 April 1988
Resolved 1 April 1988
Construction/Loadline
Issued 31 March 1987 Resolved
PROVIDE COPIES OF APPROVED PLANS FOR THE ADDITION OF THE FIXED BALLAST TO THE FOREPEAK AND THE FOAM FLOTATION IN THE NUMBER ONE VOID. COMPLIANCE DATE IS 30APR87
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Construction/Loadline
Issued 31 March 1987 Resolved
PROVIDE COPIES OF APPROVED PLANS FOR THE MODIFICATION OF THE CORNER WELD WHERE THE SIDE SHELL AND DECK ARE CONNECTED. COMPLIANCE DATE IS 30APR87
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Construction/Loadline
Issued 31 March 1987 Resolved
PROVIDE COPIES OF APPROVED PLANS FOR THE ADDITION OF THE SPONSONS TO THE AFT BOTTOM OF THE VESSEL. COMPLIANCE DATE IS 30APR87
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Accommodation/Occupational Safety
Issued 31 March 1987 Resolved
PROVIDE PLANS AND DATA FOR APPROVAL OF INSTALLED AIR RECEIVERS IN ACCORDANCE WITH 46 CFR 54.01-5. COMPLIANCE DATE IS 30APR87
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Accommodation/Occupational Safety
Issued 31 March 1987 Resolved
PROVIDE MEANS FOR DETERMINING WHEN THE SEWAGE HOLDING TANK IS 3/4 FULL IN ACCORDANCE WITH 33 CFR 159.83 AND 46 CFR 56.50-9(A). COMPLIANCE DATE IS 30APR87
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Electrical
Issued 31 March 1987 Resolved
ALL ELECTRAICAL CONNECTIONS UNDER THE WHEEL HOUSE CONSOLE, WIRE JOINTS, AND SPLICES SHALL BE IN ACCORDANCE WITH 46 CFR 183.50-50. COMPLIANCE DATE IS 30APR87
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Navigation
Issued 31 March 1987 Resolved
PROVIDE A COMPASS DEVIATION TABLE AND POST IN THE WHEEL HOUSE. COMPLIANCE DATE IS 30APR87
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Documentation
Issued 31 March 1987 Resolved
THE VESSEL SHALL NOT BE PLACED INTO SERVICE OR CARRY PASSENGERS UNTIL A STABILITY LETTER IS ISSUED BY THE USCG AND POSTED IN ACCORDANCE WITH 46 CFR 170.120 AND 185.12 COMPLIANCE DATE IS 30APR87
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Lifesaving
Issued 31 March 1987 Resolved
THE TOTAL NUMBER OF PERSONS ALLOWED IS RESTRICTED TO 500 PERSONS UNTIL ADDITIONAL LIFE PRESERVERS AND BUOYANT APPARATUS ARE PROVIDED TO ACCOMMODATE 525 TOTAL PERSONS. COMPLIANCE DATE IS 30APR87
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.