MAURY USCG vessel records Sign in
← All vessels

BEN FRANKLIN

BEN FRANKLIN is a 1987 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1987, most recently in July 2025, along with 208 deficiencies — 2 with no resolution recorded — and 4 operational controls.

Records from 1987 to 2025. Most recent: inspection, 22 July 2025.

Built
1987
Last inspected
22 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF5984
280677
Flag
UNITED STATES
367469370
Maury page id
psix-280677

Inspections, by type

…with no type recorded8
…past their stated due date2
Years with a record 36 calendar years (1987–2025)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)84.5 ft × 25.0 ft × 7.7 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFREEPORT SHIPBUILDING · FREEPORT, FL, UNITED STATES · built 1987
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPHILADELPHIA, PA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 4 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN2784MMSI 367469370 · active · compulsorily equipped · granted 30 June 2022, expires 30 June 2032
WDF5984MMSI 367469370 · expired · compulsorily equipped · granted 20 October 2010, cancelled 26 December 2020
WCZ8850MMSI not assigned · expired · compulsorily equipped · granted 19 June 2000, cancelled 21 August 2010 · licensed under a name not among this hull’s recorded names (not shown)
WCK3873MMSI not assigned · expired · compulsorily equipped · granted 28 July 1994, cancelled 2 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 82

22 July 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8191155
24 April 2025 Security Breach
Type not classified · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8119977
22 August 2024 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8012530
18 June 2024 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7937879
6 May 2024 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7907210
2 April 2024 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7888607
14 September 2023 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7791375
15 August 2023 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7769165
31 May 2023 In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7709908
8 March 2023 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7648095
3 March 2023 Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7640336
7 December 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7605468
24 June 2022 COI Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7480247
31 January 2022 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7388065
31 August 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7301036
1 April 2021 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7166967
19 March 2021 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7159354
26 August 2020 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7043710
2 July 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6998738
8 July 2019 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6741410
27 February 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6633495
9 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6506023
26 March 2018 Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6377147
9 March 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6369166
31 March 2017 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6115311
26 January 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6077982
1 July 2016 Annual Inspection · MTSA Verification · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5925562
7 May 2014 DAPI Audit · Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4878638
5 January 2012 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4218960
9 December 2010 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3907609
19 October 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3873036
28 January 2010 Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3671289
27 April 2009 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3462888
2 April 2008 Re-Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3175890
20 March 2008 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3168024
16 May 2007 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2931831
30 August 2006 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2763121
10 January 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2564313
19 May 2005 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2362305
17 May 2005 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2359533
11 May 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2061918
16 April 2004 Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2045506
7 January 2004 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1977295
13 May 2003 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1789376
21 May 2002 MARPOL Annex V Examination · COI Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1617999
19 March 2002 Administrative Inspection
Administrative · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1494797
28 January 2002 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1481755
12 June 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1444611
12 May 2001 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 48861
30 May 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1376192
6 April 2000 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1413693
20 January 2000 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 813913
10 August 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1432185
25 May 1999 COI Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1444163
3 June 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 792437
30 March 1998 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 786733
13 November 1997 Drydock Extension
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1121617
10 June 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1110449
20 March 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1103214
30 May 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1086033
21 November 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 949437
21 November 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1191257
5 June 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1188708
7 June 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1335901
13 April 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1168424
5 October 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1161503
7 June 1993 COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 846957
24 June 1992 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 943261
12 May 1992 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1433941
17 May 1991 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1235774
9 May 1991 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 922457
13 November 1990 Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1235072
24 May 1990 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1220966
1 March 1990 Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 910948
25 May 1989 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1204627
2 September 1988 Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1043138
17 June 1988 Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 892006
3 June 1988 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1198854
7 December 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1310565
11 August 1987 Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1337829
27 April 1987 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1308919
27 April 1987 Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1336056

Deficiency record · 208

14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 22 July 2025 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. MI observed engine room bilge had standing oily water. O/O is to remove oily water from engine room and provide MI receipt from company cleaning bilge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2025
Resolved 14 October 2025
Resolution: Owner cleaned bilges and took containers to Auto Zone to dispose.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 July 2025 Resolved
A hatch cover must: Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. The hatch chain was broken from the forward compartment. O/O is to install chain or device that would prevent hatch cover from being lost.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2025
Resolved 14 October 2025
Resolution: Owner placed chain on hatch to satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 July 2025 Resolved
Each life ring buoy must not be permanently secured in any way. MI observed life ring line was tied to the vessel and life ring. O/O untied the life line to satisfaction of MI.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 22 July 2025
Resolved 22 July 2025
Resolution: Owner untied life line from vessel to satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2025 Resolved
Each life jacket carried on board the vessel must be marked in accordance with § 122.604 of this chapter. The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jacket. The stowage containers for the life jackets were not marked with the quantity stowed. O/O marked stowage containers with appropriate quantity to satisfaction of MI.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 22 July 2025
Resolved 22 July 2025
Resolution: Owner marked stowage compartments for life jacktes to satisfaction of MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2025 No resolution recorded
Glass and other glazing material used in windows must be of material that will not break into dangerous fragments if fractured. MI discussed with O/O capability of replacing cracked window on main deck on forward part starboard side of vessel. O/O is to replace glass to satisfaction of MI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 December 2025 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2025 No resolution recorded
Electrical installations must be suitable for the roll, pitch, and vibration of the vessel underway. MI observed outlet in lazarette compartment was not suitable for wet environment. MI proposed installing a Ground Fault Circuit Interpreter (GFCI) outlet in space.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 December 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 June 2024 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump shall be fitted with a pressure gage. The vessel's fire pump's packing gland was leaking at the time of testing. Address the issue involving the packing leak on the vessel's fire pump. 46 CFR 181.10-1(c) "OLD T"
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 July 2024
Resolved 25 June 2024
Resolution: Fire pump seal was replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 18 June 2024 Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. FCC Station License expired in 2020. Replace with new. 47 CFR 80.13
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2024
Resolved 22 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2024 Resolved
Installation if diesel engine exhaust pipe shall be in accordance with 46 CFR 182.15-15; (182.15-15 (3): That part of the exhaust system between the point of cooling water injection and the engine manifold shall be water-jacketed or effectively insulated. MI observed a leak on the engine exhaust. Replace insulation to address leak.46 CFR 182.20-20 "OLD T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2024
Resolved 22 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 June 2024 Resolved
Each life jacket must be marked with Type I retroreflective material approved in accordance with § 164.018 in subchapter Q of this chapter, or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996 must be as specified by IMO Resolution A.658(16), “Use and Fitting of Retro-Reflective Materials on Life-Saving Appliances.” Observed that some of the vessel's PFDs needed new retroflective tape. Replace worn out tape with new.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 June 2024
Resolved 22 August 2024
Resolution: replaced with new retro tapes.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 June 2024 Resolved
Fire hose shall be 1.5 inches in diameter and 50 ft in length. MI observed holes on the fire hose located at Fire Hydrant #2. Replace with new fire hose meeting standards.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 June 2024
Resolved 22 August 2024
Resolution: replaced with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2023 Resolved
The rated relieving capacity of safety and relief valves for use on pressure vessels shall be based on actual flow test data and the capacity shall be certified by the manufacturer in accordance with one of the following.... MI observed a relief valve on the air receiver that did not re-seat. Vsl is require to replace and test new relief valve once install to the satisfaction of the attending Marine Inspector. CITE: 46 CFR 54.15-10(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 21 June 2023
Resolution: Replace relief valve wit a 150psi relief valve.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2023 Resolved
S and L. A voltage and an ammeter shall be provided that can be used for measuring voltage and current for each generator. MI observed that the ammeter for #1 gen was not working/inop. Vsl is required to repair/replace to the satisfaction of the attending Marine Inspector. CITE: 46 CFR 183.10-5(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 10 October 2023
Resolution: received photos of operation meters
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 June 2022 Resolved
Four (4) windows are cracked (1-3rd deck bridge, 1-2nd deck port side, 2-1st Deck Fwd). Each window must be capable of withstanding the maximum load from wave and wind conditions expected. Replace broken windows at next drydock. CITE: 46 CFR §116.1020
Action required: 705 - Other - as specified
Due 31 January 2023
Resolved 15 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 June 2022 Resolved
heir are various type PFDs onboard, but donning instructions for only one type. Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places for the PFDs available. Ensure that donning instruction placards are posted conspicuously for each type of PFD onbaord the vessel. CITE: 46 CFR §122.516
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 19 September 2022
Resolution: Photo submitted.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 24 June 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2022
Resolved 2 August 2022
Resolution: Received copy of Ben Franklin's new FCC Radio Sta Lic to Exp 2032
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 24 June 2022 Resolved
The overboard discharge valve for the MSD (sewage tank) is unlocked. Operator must secure MSD in a manner which prevents discharge. Secure valve to prevent accidental discharge of sewage. CITE: 33 CFR §159.7(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 9 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2022 Resolved
Each pressure vessel is to be examined every 5 years and it's safety or relief valves must be examined or tested twice in every 5 years. The air receiver and valve is past-due for examination/testing. The tank is to be hydro-tested to 1.25 MAWP. The serviced solenoid operates at 110 psi, and the relief valve is set to 150 psi, therefore 150 psi is to be the MAWP for the test; the hydrostatic test pressure is to be no more than 187.5 psi. CITE: 46 CFR §61.10-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2022
Resolved 27 October 2022
Resolution: Witnessed satisfactory hydrostatic test of P/V to >1.25 lifting pressure of safety relief valve; held w/o leaking water for 10 minutes.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2022 Resolved
Automotive-style blade fuses are installed in a circuit tapped off of both starters. Automotive-style fuses are not allowed. Properly rewire the circuits. CITE: 46 CFR §183.380(l)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 9 August 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 June 2022 Resolved
All fire fighting equipment must be ready for use. One of the vari-nozzles was inoperative. Replace with new or repair the broken nozzle. CITE: 46 CFR §181.320(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 9 August 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2022 Resolved
The vessel is not req'd to have a second generator, and current "back-up" generator does not have a data plate. Lock-out/Tag-out #2 generator to prevent inadvertent use until operating specs can be confirmed (may be used for emergency power only). CITE: 46 CFR §183.322(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 19 September 2022
Resolution: Photos were received showing gen is tagged out/locked out.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2022 Resolved
The interlock to prevent simultaneously energizing the vessel with shore power and either generators is not properly arranged. An interlock must be able to prevent simultaneously energizing the vessel with generator power and shore power. Properly configure interlock. CITE: 46 CFR §183.322(b)
Action required: 705 - Other - as specified
Due 28 February 2023
Resolved 15 August 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2022 Resolved
The Hz (current) gauge is inoperative for either generator in the engine room. Replace/repair Hz meter. CITE: 46 CFR §111.30 25(e)(1)(iii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2022
Resolved 8 March 2023
Resolution: Received photo of proper operation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2022 Resolved
The generator running indicator lights are inoperative for either generator in the engine room. Replace/repair generator running indicator lights. CITE: 46 CFR §111.30 25(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2022
Resolved 8 March 2023
Resolution: Received photos of proper operation.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 31 January 2022 Resolved
Extensive pitting identified port side chine area from bow to stern. Other areas identified: lazerette on the port side from chine to first longitudinal sniffer and scaling in the bottom plate around the port side. Clean all areas identified by Marine Inspectors and submit UT gauging report followed by repair proposal. Prior to credit dry dock. 46 CFR 176.25.
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 27 May 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 January 2022 Resolved
Port and Starboard rudders have cracked welds that separated the rudder stem from the rudder body. Rudder body has pitting with cracked welds that have wasted behind the filler metal. Grind out welds and clean up the rudder body in order to assess the extent of the damage. Submit plan for repair. Prior to credit dry dock. 46 CFR 176.25.
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 27 May 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 January 2022 Resolved
Port engine exhaust pipe is corroded and has pin holes. Support strut has been wasted from exhaust pipe. Submit repair proposal and replace both items. Prior to credit dry dock. Prior to credit dry dock. Prior to credit dry dock.46 CFR 182.20-20.
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 27 May 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 31 January 2022 Resolved
Gate valve on MSD was not removed for inspection and ball valve on fire pump uptake was ceased. Gate valve must removed for examination and ball valve on fire pump must be operable. 46 CFR 176.25.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2022
Resolved 27 May 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 January 2022 Resolved
Horizontal fire screen doors fitted to decks between galleys & accommodation spaces are to be fitted with doors that meet 46 CFR 72.05-25, 72.05-20(c), and 111.99. The currently installed horizontal deck plate door does not meet regulatory requirements. Establish an agreed-upon schedule with [name withheld] for retrofitting a compliant fire screen door. CITE: 46 CFR §72.05-10(c)(1) (see also MVI Policy Letter 15-93 para.4.b.ii)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 February 2023
Resolved 2 February 2024
Resolution: Attended vsl to observed the doors, all sat/approved.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 August 2020 Resolved
Vessel was unable to provide FCC safety radio telephony certificate. Provide certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2020
Resolution: Verified onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 August 2020 Resolved
Vessel FCC bridge to bridge certificate is expired. Provide certificate following inspection by licensed technician.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2020
Resolution: Verified onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 August 2020 Resolved
Floating waterlight does not function. Provide functioning waterlight. Vessel restricted to daylight operations.
Action required: 705 - Other - as specified
Resolved 18 September 2020
Resolution: Verified onboard.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 August 2020 Resolved
Vessel fire hydrants do not have spanner wrenches. Provide spanner wrenches at each hydrant.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2020
Resolution: Verified onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 26 August 2020 Resolved
Vessel does not have draft or loading marks. Ensure vessel has proper hull markings prior to completion of next credit drydock.
Action required: 705 - Other - as specified
Resolved 27 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 26 August 2020 Resolved
Vessel does not have a valid certificate of documentation. Provide valid certificate of documentation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2020
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 26 August 2020 Resolved
Watertight doors not marked. Mark watertight doors on both sides in clearly legible letters at least 1 inch in height “WATERTIGHT DOOR—KEEP CLOSED”.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2020
Resolution: Verified onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 August 2020 Resolved
Battery terminals on multiple batteries are corroded, terminals are damaged and there is standing water in battery boxes and on battery tops. Clean battery posts and terminals, replace damaged terminals and clean battery boxes and battery tops of water.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2020
Resolution: Verified onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 August 2020 Resolved
Multiple battery chargers do not have ammeters in the charging circuit. Replace battery chargers with a type t that have an ammeter or include an ammeter in the charging circuit. Submit proposal for rectifying this deficiency prior to replacing or installing equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 May 2021
Resolution: Resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 August 2020 Resolved
Fuel sight glass is not fitted with device which will automatically close in event of rupture of the gage or gage lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 August 2020 Resolved
Personal flotation device storage bins are not adequately marked. Mark bins with quantity of PFDs and size (adult/child) in letters and numbers at least 2 inches high. Adult and child PFDs are to be separate from adult life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2020
Resolution: Verified onboard.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 26 August 2020 Resolved
Vessel does not have man overboard or abandon ship drills and training logged. Perform man overboard and abandon ship drills and training.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2020
Resolution: Verified onboard.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 August 2020 Resolved
Vessel does not have fire drills and training logged. Perform fire drills and training.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2020
Resolution: Verified onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2020 Resolved
Remove dead ended wires in bar area on upper deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2020
Resolution: Verified onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 August 2020 Resolved
Flame shield bowls were missing on both MDEs. Install new bowls prior to operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2020
Resolution: Verified onboard.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 August 2020 Resolved
Port engine room fire extinguisher bracket was broken. Renew bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2020
Resolution: Verified onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 26 August 2020 Resolved
Starboard engine room pendant light was missing cage. Corrected on the spot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2020
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 26 August 2020 Resolved
Identified large open bucket of diesel fuel inside of the bilge. Corrected on the spot.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2020
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 August 2020 Resolved
Emergency exit in forward space of dining area on main deck was blocked. Ensure emergency exit is accessible.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2020
Resolution: Verified onboard.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 August 2020 Resolved
Watertight door leaving the engine room and entering the galley had a hold back in place damaging the A-60 fire boundary insulation. Replace insulation and ensure hold backs are not used when underway.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 March 2021
Resolution: Received proof of installation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 August 2020 Resolved
Hole identified in starboard side window of operating station. Repair to ensure A-0 fire boundary is maintained.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2020
Resolution: Verified onboard.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 August 2020 Resolved
Hole identified in the aft bulkhead of the operating station. Repair to ensure A-0 fire boundary is maintained
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2020
Resolution: Verified onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 July 2020 Resolved
Vessel has passed the 3 month window for it's annual inspection due NLT 03JUL2020. Vessel request a deferment of 1 month that is in routing. At this time, vessel is not allowed to operate with passengers until the annual inspection can be conducted by a Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2020
Resolved 21 January 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 July 2019 Resolved
Obtain valid FCC Bridge-to-Bridge Radio Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2019
Resolved 18 July 2019
Resolution: Vessel obtained a valid FCC Bridge-to-Bridge Cert.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 July 2019 Resolved
Provide date for last Vessel Security Assessment, or conduct a new one. Audits are an annual requirement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 8 August 2019
Resolution: Vessel completed a new Security Audit on their VSP.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 July 2019 Resolved
Ensure Watertight Door indicator light works on bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2019
Resolved 18 July 2019
Resolution: Watertight Door indicator light was repaired on the bridge.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 July 2019 Resolved
Replace bulb in stern navigation light. Vessel restricted to daylight operations until fixed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2019
Resolved 18 July 2019
Resolution: Vessel replaced stern navigation light bulb.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 July 2019 Resolved
Replace sight glass on fuel tank to make it one continuous piece.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2019
Resolved 8 August 2019
Resolution: Vessel purchased and installed a new sight tube made of a single piece of glass.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 July 2019 Resolved
Place protective lens over light in storage space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2019
Resolved 18 July 2019
Resolution: Vessel placed a protective lens over the light in the storage space.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 8 July 2019 Resolved
Replace worn lagging on port side exhaust in lazarette.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2019
Resolved 8 August 2019
Resolution: Vessel installed new lagging on the port side exhaust pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2019 Resolved
Place chaffing gear around port hydraulic hose on steering assembly. Replace hose if necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2019
Resolved 18 July 2019
Resolution: Vessel placed chaffing gear around the port hydraulic hose on the steering assembly.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018 Resolved
Vsl is broadcasting: No static draft information and no dimension information (AIS Antenna Position ABCD values equals 0).
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 6 November 2018
Resolution: AIS information updated.
Fire Fighting › Fire Hoses › Number
Issued 26 March 2018 Resolved
MAB01: One length of fire hose shall be provided for each hydant. Owner ID'd that fire hose is dry-rotted with pinholes. Provide vessel with fire hose.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2018
Resolution: New hose was purchased and installed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 26 March 2018 Resolved
MAB02: Provide vessel with alcohol testing strips.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2018
Resolved 29 March 2018
Resolution: Constorium provided MPAK kit to vessel.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 26 March 2018 Resolved
MAB04: Replace outlets next to galley sinks w/ GFI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 April 2018
Resolved 26 June 2018
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 March 2018 Resolved
MAB05: Place non-conductive matting next to all switchboards (adequate for voltage).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 April 2018
Resolved 26 June 2018
Documentation › Logs/Records › Drug Test Records
Issued 9 March 2018 Resolved
KB03. Provide proof of designation for drug and alcohol program designated employee representative. 49CFR40.3
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2018
Resolved 26 June 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2017 Resolved
EKO01 Remove oil soaked insulation and clean underneath pilothouse helm station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2017
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 3 April 2017 Resolved
Replace retroreflective tape on 96 adult lifejackets as identified. Passenger count limited to 242 total persons.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2017
Resolution: Supplied 60 lifejackets to meet 302 total persons.
Engineering › Steering Gear System › Hydraulic Hose
Issued 31 March 2017 Resolved
Remove hydraulic overflow draining bucket on bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 4 May 2017
Engineering › Steering Gear System › Hydraulic Hose
Issued 31 March 2017 Resolved
Repair bow thruster (hydraulic leaks and start from bridge). Prove proper operation to USCG. Bow thruster secured by attending USCG MI on 04MAY2017
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 9 March 2018
Resolution: Observed proper operation.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 31 March 2017 Resolved
Repair rudder angle indicator in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 9 March 2018
Resolution: Observed proper operation.
Engineering › Bilge Water Management System › Not Installed
Issued 31 March 2017 Resolved
Relabel bilge alarms on bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 4 May 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 March 2017 Resolved
Anchor light obstructed by radar. Make arch of visibility 360 degrees for anchor light. Prior to anchoring at night.
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Due 17 April 2017
Resolved 4 May 2017
Construction/Loadline › Penetrations › Gasket
Issued 31 March 2017 Resolved
Forward and aft hatches are missing securing line. Attach securing lines to hatch covers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 4 May 2017
Engineering › Diesel Engine (auxiliary) › Block
Issued 31 March 2017 Resolved
On port main engine flywheel is exposed and poses safety hazard. Place guard over front of port engine.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 4 May 2017
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 31 March 2017 Resolved
Conduct DAPI crew training.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 4 May 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 July 2016 Resolved
Masthead light does not have an arch of visibility of 225 degrees. Replaace with appropriate light of correct configuration.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 July 2016
Resolution: Vessel crew cut arc shield back, to allow 225 degree of visibility.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 July 2016 Resolved
Mounting housing on starboard sidelight is bent and obstructs arc of visibility. Restore to original condition.
Due 14 July 2016
Resolved 15 July 2016
Resolution: Vessel bent mounting plate that the side light rests on and it is no longer restricting visibility of the light.
Engineering › Steering Gear System › Follow-up Assembly
Issued 1 July 2016 Resolved
Remove overflow of hydraulic oil from bridge.
Condition: Improper Installation
Due 14 July 2016
Resolved 15 July 2016
Lifesaving › Lifebuoys › Stowage
Issued 1 July 2016 Resolved
Ring buoy on upper deck replace mounting bracket.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 15 July 2016
Resolution: New Bracket installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 July 2016 Resolved
Make VHF radio DSC capable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 15 July 2016
Resolution: DSC installed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 July 2016 Resolved
Vessel's COD expired in DEC 2014, vessel must get a valid COD.
Action required: 705 - Other - as specified
Due 14 August 2016
Resolved 4 August 2016
Resolution: COD obtained.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 1 July 2016 Resolved
Vessel must have alcohol test kit on board, provide 60 min supervisor training, and prove that company submitted MIS report to CG.
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 15 July 2016
Resolution: Verified alcohol test kits, training conducted, and MIS report submitted.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 1 July 2016 Resolved
Vessel needs current light list and Coast Pilot.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 15 July 2016
Resolution: Verified vessel obtained pubs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2016 Resolved
Remove dead end wire in 2nd deck lifejacket compartment.
Condition: Damaged By Earlier Event
Due 15 July 2016
Resolved 15 July 2016
Resolution: Wire removed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 1 July 2016 Resolved
Remove extra surge protectors from 2nd deck bar and E?R by fire pump, ensure all surge protectors are marine type.
Condition: Improper Installation
Due 15 July 2016
Resolved 15 July 2016
Resolution: Surge protectors removed.
Electrical › Electrical Distribution System (emergency) › Distribution Panel Bus
Issued 1 July 2016 Resolved
Install blank in electrical distribution box E/R port side.
Condition: Improper Installation
Due 15 July 2016
Resolved 15 July 2016
Resolution: Blank installed.
Lifesaving › Lifebuoys › Serviceable
Issued 1 July 2016 Resolved
Add retro relfective tape onto back of ring buoy on 3rd deck
Condition: Improper/Lack of Maintenance
Due 4 August 2016
Resolved 4 August 2016
Resolution: Correct tape installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 July 2016 Resolved
Anchor light inop, lense is frosted. Replace both to satisfaction of CGMI. Vessel is restricted from anchoring at night or periods of low visability.
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 29 July 2016
Resolution: Anchor light lense replaced.
Electrical › Lighting (service) › Lighting Feeder
Issued 7 May 2014 Resolved
Remove ALL dead end wiring located at the dj booth on 2nd deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 30 May 2014
Resolution: Dead end wiring removed. ALL SAT
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 7 May 2014 Resolved
Repair/Replace # 2 Gen muffler, currently causing exhaust leak and piping worn/wasted. Must be repaired prior to carrying PAX
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2014
Resolved 9 May 2014
Resolution: Replaced and tested. ALL SAT
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 7 May 2014 Resolved
Label 03 distribution panels loacted in engine room, galley and 2nd deck bar.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 30 May 2014
Resolution: 03 Panels Labled
Electrical › Electric Supply System (service) › Cable
Issued 7 May 2014 Resolved
Remove ALL Romex wiring located in the Galley and at the engine room aft entrance.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 May 2014
Resolved 21 May 2014
Resolution: Romex removed.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 7 May 2014 Resolved
Install/replace current PFD Donning Placard. Current Placard does NOT show current type I PFD on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2014
Resolved 9 May 2014
Resolution: Correct Placard Posted
Fire Fighting › Fire Main › Condition
Issued 7 May 2014 Resolved
Remove/repair soft patch piping repair on fire main piping in engineroom. Soft patch repairs are NOT allowed on vital systems. Prior to carrying PAX
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2014
Resolved 9 May 2014
Resolution: Patch repaired to the satisfaction of MI.
Construction/Loadline › Structures › Deck Plating
Issued 7 May 2014 Resolved
Repair/seal 03 above deck opening located in galley. Currently vessel has rags stuffed in openings. UNSAT
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 30 May 2014
Resolution: 03 deck opening sealed. ALL SAT
Construction/Loadline › Hull › Bottom Plating
Issued 28 January 2010 Resolved
Vessel is required to complete an outstanding Hull Exam prior to the carriage of passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2010
Resolved 1 March 2010
Resolution: Completed hull exam, issued 858 to amend COI.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 27 April 2009 Resolved
Provide approved Vessel Security Plan before carrying more than 150 passengers.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 22 September 2010
Resolution: attended vessel and reviewed security plan, also, provided owner with copy of approval letter, he stated he never got one. Item Cleared.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 April 2009 Resolved
Senior deckhand must prove that he is capable of returning vessel safely to port in accordance with U.S.C.G NVIC 1-91.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 22 September 2010
Resolution: witnessed senior deckhand [name withheld] get underway and moor vessel, cleared 835 item.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 27 April 2009 Resolved
Provide a certificate of documentation with the name change or change back name on vessel hull and all associated lifesaving equiptment prior to carrying passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 November 2009
Resolved 2 December 2009
Resolution: New COD issued and in MISLE system.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 2 April 2008 Resolved
Repair/Replace switchboard interlock in engineroom.
Due 10 April 2008
Resolved 14 April 2008
Resolution: Made necessary repairs to switchboard interlock. Interlock now functions properly.
Electrical › Electrical Distribution System (service) › Cable
Issued 2 April 2008 Resolved
Repair electrical shoretie plug on shore side.
Due 10 April 2008
Resolved 14 April 2008
Resolution: Repaired electrical shore tie plug on shore side.
Electrical › Electric Supply System (service) › Battery Charger
Issued 2 April 2008 Resolved
Permanently install battery charger on Port Side Engineroom.
Due 10 April 2008
Resolved 14 April 2008
Resolution: Permanently installed battery charger on Port Side Engineroom.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 April 2008 Resolved
Install light cover on overhead light in Engineroom.
Due 10 April 2008
Resolved 14 April 2008
Resolution: Installed light cover on overhead light in Engineroom.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 2 April 2008 Resolved
Secure electrical distribution panel door cover in engineroom.
Due 10 April 2008
Resolved 14 April 2008
Resolution: Secured electrical distribution panel door cover in engineroom.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 April 2008 Resolved
Remove damaged tube lighting above pilot house and inspect all other tube lighting for damage and proper operation.
Due 4 April 2008
Resolved 14 April 2008
Resolution: Removed damaged tube lighting above pilot house and inspected all other tube lighting for damage and proper operation.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 2 April 2008 Resolved
Repair outlet cover topside bar port side.
Due 10 April 2008
Resolved 14 April 2008
Resolution: Repaired outlet cover topside bar port side.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 April 2008 Resolved
Repair steam line wiring in galley.
Due 4 April 2008
Resolved 14 April 2008
Resolution: Repaired steam line wiring in galley.
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 April 2008 Resolved
Conduct security drills with crew prior to getting underway with passengers.
Due 4 April 2008
Resolved 4 April 2008
Resolution: Conducted security drills with crew prior to getting underway with passengers.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 2 April 2008 Resolved
Secure hot water heater covers.
Due 10 April 2008
Resolved 14 April 2008
Resolution: Secured hot water heater covers.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 2 April 2008 Resolved
Remove all items above engineroom escape hatch.
Due 2 April 2008
Resolved 2 April 2008
Resolution: Removed all items above engineroom escape hatch.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 April 2008 Resolved
Secure and Mount Lifejacket lockers on port and starboard side near pilot house.
Due 10 April 2008
Resolved 14 April 2008
Resolution: Secured and Mounted Lifejacket lockers on port and starboard side near pilot house.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 20 March 2008 Resolved
Replace 1" gate valve in way of sea chest or permanently cap the same.
Action required: 705 - Other - as specified
Due 20 March 2008
Resolved 20 March 2008
Engineering › Fuel Oil Service System › Hose
Issued 20 March 2008 Resolved
Replace unapproved aeroquip fuel hose in way of starboard generator fuel intake.
Action required: 705 - Other - as specified
Due 19 April 2008
Resolved 14 April 2008
Resolution: Replaced unapproved aeroquip fuel hose in way of starboard generator fuel intake, with approved fuel hose
Engineering › Fuel Oil Service System › Hose
Issued 20 March 2008 Resolved
Provide compression type fitting for flexible hose in way of starboard generator fuel return.
Action required: 705 - Other - as specified
Due 19 April 2008
Resolved 2 May 2008
Resolution: fitting installed
Construction/Loadline › Structures › Scuttle
Issued 20 March 2008 Resolved
Provide captive chain in way of forepeak deck hatch.
Action required: 705 - Other - as specified
Due 19 April 2008
Resolved 2 May 2008
Resolution: Noted captive chain was installed
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 20 March 2008 Resolved
Make air receiver in soda hold ready for internal inspection or conduct hydrostatic testing of the same.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2008
Resolution: Completed a satisfactory internal inspection.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 16 May 2007 Resolved
Replace RPM gauge on STBD MDE.
Condition: Damaged By Earlier Event
Due 30 May 2007
Resolved 30 May 2007
Documentation › Logs/Records › Drug Test Records
Issued 16 May 2007 Resolved
Provide verifacation that all supervisors have received EAP instruction.
Condition: Unknown
Due 23 May 2007
Resolved 23 May 2007
Engineering › Bilge Water Management System › Pump
Issued 16 May 2007 Resolved
Prove proper operation of bilge pump.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2007
Resolved 23 May 2007
Documentation › Markings/Placards › Warning Signs
Issued 30 August 2006 Resolved
Lable F/O emergency shut offs.
Condition: Unknown
Due 2 September 2006
Resolved 14 September 2006
Construction/Loadline › Structures › Deck Plating
Issued 30 August 2006 Resolved
Repair deck plate support beam in galley space
Condition: Damaged By Earlier Event
Due 15 September 2006
Resolved 14 September 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 30 August 2006 Resolved
Strap down all battery box covers
Condition: Placed in Improper Service
Due 14 September 2006
Resolved 14 September 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 30 August 2006 Resolved
Remove all fluid in battery boxs
Condition: Improper/Lack of Maintenance
Due 2 September 2006
Resolved 14 September 2006
Electrical › Electric Supply System (service) › Battery Conductor
Issued 30 August 2006 Resolved
Replace all wingnuts at battery terminals
Condition: Improper Installation
Due 2 September 2006
Resolved 14 September 2006
Electrical › Electric Generation Source (service) › Panelboard
Issued 30 August 2006 Resolved
Provide a dielectric mat for switchboard.
Condition: Placed in Improper Service
Due 2 September 2006
Resolved 14 September 2006
Documentation › Markings/Placards › Warning Signs
Issued 30 August 2006 Resolved
Lable bilge manifold.
Condition: Unknown
Due 2 September 2006
Resolved 14 September 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 30 August 2006 Resolved
Properly mount electric cable in galley.
Condition: Improper Installation
Due 2 September 2006
Resolved 14 September 2006
Electrical › Electrical Distribution System (service) › Conductor
Issued 30 August 2006 Resolved
Properly connect bilge pump controller wiring at stuffing tube connecter
Condition: Improper/Lack of Maintenance
Due 2 September 2006
Resolved 14 September 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 30 August 2006 Resolved
Repair lagging on port engine exaust
Condition: Improper/Lack of Maintenance
Due 2 September 2006
Resolved 14 September 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 30 August 2006 Resolved
Repair outlet box cover at firepump
Condition: Placed in Improper Service
Due 2 September 2006
Resolved 14 September 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 30 August 2006 Resolved
Properly mount outlet box at forward bulkhead engineroom centerline.
Condition: Placed in Improper Service
Due 2 September 2006
Resolved 14 September 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 August 2006 Resolved
Install port generator belt guard.
Condition: Placed in Improper Service
Due 2 September 2006
Resolved 30 August 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 30 August 2006 Resolved
Hard wire Soda CO2 system.
Condition: Improper Installation
Due 15 September 2006
Resolved 14 September 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 30 August 2006 Resolved
Install connectors for water pumps at connection boxes
Condition: Improper Installation
Due 15 September 2006
Resolved 14 September 2006
Communications › Alarms/Indicators › Propeller Speed Indicator
Issued 30 August 2006 Resolved
Repair or replace #1 SSDG RPM Indicator.
Condition: Unknown
Due 15 September 2006
Resolved 14 September 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 30 August 2006 Resolved
Properly install wiring at outlet box and lighting wiring in soda compartment.
Condition: Placed in Improper Service
Due 15 September 2006
Resolved 14 September 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 30 August 2006 Resolved
No crew available, could not conduct drills. Provide crew and conduct MTSA drill.
Condition: Unknown
Due 7 September 2006
Resolved 14 September 2006
Electrical › Electric Generation Source (service) › Generator
Issued 17 May 2005 Resolved
Stop oil leak generator #1 prior to 31 May 05.
Due 31 May 2005
Resolved 31 August 2005
Resolution: Per copy of mechanics receipt sent by O/O, receipt scanned into documents for this activity.
Documentation › Certificates/Documents
Issued 11 May 2004 Resolved
Provide safety Radio Telephony Certificate , until provided vessel is limited to 1000 ft. from shore. LEGACY COMPONENT DESC: Safety Radio Telephone
Due 11 June 2004
Resolved 27 May 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 7 January 2004 Resolved
Repair and replace overhead lagging in A.C. room LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Resolved 16 April 2004
Engineering › Diesel Engine (propulsion-electric)
Issued 7 January 2004 Resolved
Repair exhaust leaks on port engine in A.C. room
Action required: 705 - Other - as specified
Resolved 16 April 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 7 January 2004 Resolved
Reweld lazarette access ladder
Action required: 705 - Other - as specified
Resolved 11 May 2004
Accommodation/Occupational Safety
Issued 7 January 2004 Resolved
Reweld port side exhaust support as marked in lazarette
Action required: 705 - Other - as specified
Resolved 16 April 2004
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 7 January 2004 Resolved
Provide valid certificate for servicing of portable extinguishers - and service (3) that are showing discharge LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Resolved 16 April 2004
Operations/Management › Drills/Instruction › Fire
Issued 21 May 2002 Resolved
AMEND EMERGENCY INSTRUCTION LIST TO REFLECT ACTUAL FIRE AND MAN OVERBOARD PROCEDURES.
Due 21 June 2002
Resolved 8 July 2002
Documentation › Certificates/Documents › FCC SSL
Issued 21 May 2002 Resolved
VESSEL'S OPERATOR NEEDS TO PRESENT FCC RADIO OPERATORS PERMIT.
Due 21 June 2002
Resolved 8 July 2002
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 May 2002 Resolved
ATTACH LIFERING LIGHT TO LIFERING WITH LANYARD AND DETACHABLE CLIP.
Due 21 June 2002
Resolved 8 July 2002
Deck/Cargo › Holds/Tanks › Coaming
Issued 21 May 2002 Resolved
REPAIR WATERTIGHT DOOR CONTACT INDICATOR IN GALLEY.
Due 21 June 2002
Resolved 8 July 2002
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 May 2002 Resolved
REPAIR BOW THRUSTER COMPARTMENT HIGH LEVEL BILGE ALARM.
Due 21 June 2002
Resolved 8 July 2002
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 May 2002 Resolved
PROVIDE CURRENT TIDE/TIDAL CURRENT TABLES.
Due 21 June 2002
Resolved 8 July 2002
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 21 May 2002 Resolved
PROVIDE PLUG FOR FUEL CONTAINMENT.
Due 21 June 2002
Resolved 8 July 2002
Fire Fighting › Structural - A Class Divisions › Doors
Issued 21 May 2002 Resolved
PROVIDE DOCUMENTATION/MARKING FOR FIRE BOUNDRY DOOR TO ENGINEROOM.
Due 21 June 2002
Resolved 8 July 2002
Electrical › Lighting (service) › Outlet Box
Issued 21 May 2002 Resolved
PROVIDE BLANK FOR VACANT SPACE ON BRIDGE PORT SIDE ELECTRICAL PANEL.
Due 21 June 2002
Resolved 8 July 2002
Electrical › Electrical Distribution System (service) › Switchboard
Issued 21 May 2002 Resolved
REMOVE WIRE NUTS FROM OVEN WIRING IN GALLEY OR TERMINATE CONNECTIONS IN JUNCTION BOX.
Due 21 June 2002
Resolved 8 July 2002
Lifesaving › Lifebuoys › Stowage
Issued 21 May 2002 Resolved
REPOSITION LIFE RINGS ON THE MAIN DECK AND SECOND DECK TO MAKE THEM MORE ACCESIBLE
Due 21 June 2002
Resolved 8 July 2002
Engineering › Fuel Oil Service System › Valve, Control
Issued 21 May 2002 Resolved
PROVIDE REMOTE FUEL SHUT OFF FOR GENERATOR FUEL SUPPLY.
Due 21 June 2002
Resolved 8 July 2002
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 21 May 2002 Resolved
MOUNT B II FIRE EXTINGISHER LOCATED AT 2ND DECK BAR.
Due 21 June 2002
Resolved 8 July 2002
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 21 May 2002 Resolved
SECURE GRAVEL BALLAST IN FORE PEAK.
Due 21 June 2002
Resolved 8 July 2002
Fire Fighting › Structural Fire Protection - General
Issued 10 January 2002 Resolved
Replace door to shaft room with a fire door that meets an A-15 marine or an A-90 residential door according to NVIC 9-97. LEGACY COMPONENT DESC: Accommodation Space Protection
Due 31 March 2002
Resolved 13 May 2003
Fire Fighting › Miscellaneous Items
Issued 10 January 2002 Resolved
Replace missing insulation on ceiling of galley and galley door.
Due 31 March 2002
Resolved 13 May 2003
Electrical › Electrical Distribution System (emergency)
Issued 10 January 2002 Resolved
Ensure wiring in engine room is wire tied with metallic clamps every 24 inches. LEGACY COMPONENT DESC: Wiring
Due 31 March 2002
Resolved 13 May 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 10 January 2002 Resolved
Wrap exhaust pipe prior to shaft room. LEGACY COMPONENT DESC: Piping (exhaust)
Due 31 March 2002
Resolved 13 May 2003
Construction/Loadline › Structures
Issued 10 January 2002 Resolved
Ensure watertight bulkhead is repaired above the watertight door. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 31 March 2002
Resolved 13 May 2003
Construction/Loadline › Structures
Issued 10 January 2002 Resolved
Replace gasket to watertight door. LEGACY COMPONENT DESC: Door
Due 31 March 2002
Resolved 13 May 2003
Fire Fighting
Issued 12 June 2001 Resolved
PROVIDE CREW FOR FIRE DRILL.
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Fire Fighting
Issued 12 June 2001 Resolved
UNABLE TO REACH BOW THRUSTER COMPARTMENT FROM FIRE HYDRANT. PROVIDE PLANS FOR INSTALLATION OF NEW HYDRANT SO ALL AREAS OF VESSEL CAN BE REACHED BY SINGLE HOSE. REPAIR/RENEW
Condition: Unknown
Due 31 March 2002
Resolved 13 May 2003
Documentation
Issued 12 June 2001 Resolved
POST COI, STABILITY LTR AND FCC CERTS.
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Lifesaving
Issued 12 June 2001 Resolved
LABLE ALL STORAGE OF PFD'S WITH NUMBER OF PFD'S AND TYPE.
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Lifesaving
Issued 12 June 2001 Resolved
PROVIDE SUITABLE MEANS TO RETREIVE PFD'S 2ND DECK.
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Lifesaving
Issued 12 June 2001 Resolved
LABLE BILGE HIGH LEVEL ALARMS & WTD OPEN/CLOSED INDICATOR.
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Navigation
Issued 12 June 2001 Resolved
PROVIDE A TIDAL CURRENT TABLE AND CG LIGHT LIST.
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Lifesaving
Issued 12 June 2001 Resolved
POST PFD DONNING PLACARD.
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Engineering
Issued 12 June 2001 Resolved
FUEL SIGHT GLASS IMPROPER. REPAIR/RENEW
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Accommodation/Occupational Safety
Issued 12 June 2001 Resolved
AIR RECEIVER OVER DUE HYDRO. CONDUCT TEST, RECEIVER TO BE SECURED UNTIL COMPLETED.
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Construction/Loadline
Issued 12 June 2001 Resolved
NO HIGH LEVEL ALARM IN BOW THRUSTER COMPARTMENT.
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Electrical
Issued 12 June 2001 Resolved
ELECTRICAL RECEPTICAL IN GALLEY HAS MULTIPLE PLUG ADAPTOR. REPAIR/RENEW
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Construction/Loadline
Issued 12 June 2001 Resolved
AFTER STEERING BILGE PUMP HOSE PLASTIC. REPAIR/RENEW WITH REINFORCED HOSE.
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Accommodation/Occupational Safety
Issued 6 April 2000 Resolved
Properly lable emergency escape scuttles in compt #2 and engine room.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Electrical
Issued 6 April 2000 Resolved
Remove extention cords in compt #3, as discussed.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Electrical
Issued 6 April 2000 Resolved
Provide proper globe for light in compt #5 (shaft room).
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Electrical
Issued 6 April 2000 Resolved
Properly hardwire and provide proper circuit protection for soda system pumps in compt #5 (shaft room).
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Construction/Loadline
Issued 6 April 2000 Resolved
C/R stbd fwd gunnel, IWO stbd cabin window #2 from bow, to good metal, as marked.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Accommodation/Occupational Safety
Issued 6 April 2000 Resolved
Make permanent and proper repairs to port bow and rail, IWO boarding ramp area.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Construction/Loadline
Issued 6 April 2000 Resolved
C/R inner metal flange for scuttle opening and gasket seat, IWO forepeak.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Lifesaving
Issued 25 May 1999 Resolved
POST A WARNING SIGN AT THE ENTRANCE TO THE SHAFT CMPT WHERE THE SODA MACHINE CO2 CYL ARE STORED (WARN CREW MEMBERS OF DANGERS OF CO2 SPACE). INSURE ADEQUATE VENTILATION.
Condition: Unknown
Due 15 June 1999
Resolved 9 June 1999
Construction/Loadline
Issued 25 May 1999 Resolved
REPAIR DOOR AJAR ALARM FOR WTD IN AFD BHD OF E.R. FWD BHD.
Condition: Unknown
Due 15 June 1999
Resolved 9 June 1999
Construction/Loadline
Issued 25 May 1999 Resolved
REPAIR BILGE ALARM FLOAT IN CMPT FOR SHAFT STUFFING BOXS. (RETAINER CLIP MISSING).
Condition: Unknown
Due 15 June 1999
Resolved 9 June 1999
Electrical
Issued 5 June 1995 Resolved
BLANK OFF AND LABEL CIRCUIT BREAKER BOX CENTER FORWARD BULKHEAD IN ENGINE ROOM - 3 PORTS IN FACE OF PANEL.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Construction/Loadline
Issued 5 June 1995 Resolved
MAKE WATERTIGHT THE WIRE RUNS BETWEEN ENGINE ROOM AND GALLEY.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Construction/Loadline
Issued 5 June 1995 Resolved
MAKE WATERTIGHT OLD THRU BULKHEAD PENETRATIONS BETWEEN TANK ROOM AND LAZARETTE.
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Lifesaving
Issued 7 June 1994 Resolved
AT THE ENTRANCE WAY TO EACH UPPER DECK MARK IN 1" LETTERS THE MAXIMUM NUMBER OF PASSENGERS ALLOWED. MIDDLE UPPER DECK- 129 & SUN DECK 64. CITE: 46 CFR 185.30-3 9e), (1992 REVISION).
Condition: Unknown
Due 7 June 1994
Resolved 7 June 1994
Engineering
Issued 7 June 1994 Resolved
HYDROSTATICALLY TEST AIR RECEIVER TO 1 1/4 MAWP (250 PSI) TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 June 1994
Resolved 7 June 1994
Unknown
Issued 13 April 1994 Resolved
INSTALL DRAFT MARKS FORE & AFT-PORT & STBD SIDE.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Construction/Loadline
Issued 13 April 1994 Resolved
REPLACE BRACKET SUPPORT ON SCUTTLE TO FORE PEAK.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Engineering
Issued 7 June 1993 Resolved
PROVIDE LAGGING FOR STBD MDE EXHAUST LINE JUST AFT OF EXHAUST MANIFOLD.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Engineering
Issued 7 June 1993 Resolved
PROVE PROPER OPERATION OF MDE TACHOMETERS.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Fire Fighting
Issued 7 June 1993 Resolved
PROVE PROPER OPERATION OF PRESSURE GUAGE FOR FIRE PUMP. THE ABOVE REQUIREMENTS TO BE CLEARED BY 21JUN93 TO SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Engineering
Issued 7 June 1993 Resolved
PROVIDE PROOF THAT ENTIRE BOW THRUSTER INSTALLATION WAS IAW APPROVED PLANS.TO BE COMPLETED BY 09JUL93.
Condition: Unknown
Due 6 October 1993
Resolved 6 October 1993
Lifesaving
Issued 12 May 1992 Resolved
REPLACE EPIRB ABOARD, UNTIL ABOARD, VSL LIMITED TO RIVERS ONLY.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Lifesaving
Issued 12 May 1992 Resolved
PLACE NON-SKID ON RUNGS & PLATFORM ON RESCUE LADDER.
Condition: Unknown
Due 26 May 1992
Resolved 27 May 1992
Documentation
Issued 27 April 1987 Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987
Documentation
Issued 27 April 1987 Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987
Documentation
Issued 27 April 1987 Resolved
PROVIDE VALID FCC: A) SHIP AIRCRAFT RADIO STATION LICENSE. B) SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987
Lifesaving
Issued 27 April 1987 Resolved
PLACE ONBOARD, MARK AND PERMANENTLY SECURE PFD STORAGE BOXES TO DECK.
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987
Lifesaving
Issued 27 April 1987 Resolved
SATISFY LOCAL [name withheld] REQUIREMENT AND FIXED SEATING ARRANGEMENT.
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987
Deck/Cargo
Issued 27 April 1987 Resolved
PROVIDE PROOF THAT ENTIRE BOW THRUSTER INSTALLATION WAS IAW APPROVED PLANS.
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987
Documentation
Issued 27 April 1987 Resolved
PROVIDE COPY OF ADMEASUREMENT CERTIFICATE.
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987

Ownership record