Records from 1987 to 2026. Most recent: inspection, 17 March 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 61
17 March 2026
Administrative Inspection · Vessel Attendance · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8327462
12 February 2026
Drydock Exam · Vessel Attendance · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8304893
11 February 2025
Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8071080
16 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7896218
22 February 2024
Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7868754
21 February 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7639519
23 February 2022
Internal Structural Exam · Drydock Extension
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7400786
16 February 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7397120
28 December 2021
Type not recorded
No type recorded · USCGC SEA HORSE (WPB 87361) · USCG Heartland District (CGD-H) · Activity 7373431
24 February 2021
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7146037
12 February 2020
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6901508
8 January 2020
In-Service Inspection · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6886202
11 March 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6640324
24 August 2018
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6549309
3 April 2018
Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 6384703
28 February 2018
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6360404
12 February 2018
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6350422
22 February 2017
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6088419
29 February 2016
DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5815263
1 February 2016
Administrative Inspection · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5803991
11 July 2012
Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 4376180
6 February 2012
Hull Examination · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4237555
23 February 2011
Simplified Stability Test
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4155741
5 November 2010
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3885493
9 December 2009
Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3643323
1 December 2004
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2174285
12 November 2003
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1950429
20 March 2003
Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1759625
28 January 2003
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1733779
26 April 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1611449
19 March 2002
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1495116
8 May 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1401405
14 September 2000
Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 822413
27 July 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 151379
13 June 2000
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1452684
15 February 2000
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1378947
19 August 1999
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 779167
1 April 1999
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 808071
1 April 1999
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1461179
24 June 1998
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1364915
10 February 1997
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1434520
18 June 1996
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1402302
20 April 1995
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1214744
24 March 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1166392
7 February 1994
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 853580
31 August 1993
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1136274
20 May 1993
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 841809
8 July 1992
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1261275
22 October 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 941468
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1248295
28 August 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1251119
11 July 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1246742
20 June 1991
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 901058
9 August 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 927934
19 June 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 924330
22 February 1990
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899742
15 August 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1044380
26 July 1988
Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1341849
1 July 1988
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 895857
27 August 1987
Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1013013
26 August 1987
Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1025129
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2025
Resolved
Remote fuel shutoff valve for generator was missing valve handle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 12 February 2025
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 February 2025
Resolved
PFD stowage boxes required accurate quantity/labeling.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2025
Resolved 12 February 2025
Resolution: Corrected.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 29 February 2016
Resolved
Provide valid fire extinguisher service report for all extinguishers
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2016
Resolved 7 March 2016
Resolution: Vessel provide service report.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 29 February 2016
Resolved
Provide valid fixed system service report attesting that alarm and indicating light are properly operating
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2016
Resolved 7 March 2016
Resolution: Vessel provided service report.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 29 February 2016
Resolved
Provide valid FCC radio safety telephony certificat.
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 7 March 2016
Resolution: Vessel provided certificate
Documentation › Certificates/Documents › FCC SSL
Issued 12 November 2003
Resolved
PROVIDE COPY OF CURRENT FCC RADIOTELEPHONE SAFETY CERTIFICATE.
Action required: 705 - Other - as specified
Resolved 6 December 2005
Resolution: Vessel is out of service and doesn''t hold a COI. Valid FCC certificates must be obtained prior to obtaining COI.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 20 March 2003
Resolved
Repair engine shut-down via your FFFE system. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Due 20 March 2003
Resolved 21 March 2003
Resolution: fax documentation.
Lifesaving › Lifejacket/PFD (General)
Issued 20 March 2003
Resolved
Repair/replace all wasted retro-reflective tape and lights for all life preservers, as needed. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 20 March 2003
Resolved 21 March 2003
Resolution: fax documentation.
Navigation › Piloting/Steering
Issued 20 March 2003
Resolved
Re-locate mast light above bimini top. LEGACY COMPONENT DESC: Mast Light
Condition: Improper Installation
Due 20 March 2003
Resolved 12 November 2003
Resolution: RELOCATED.
Lifesaving › Buoyant Apparatus
Issued 20 March 2003
Resolved
Place name of vessel on life float and oars. LEGACY COMPONENT DESC: Name on LF and oars
Condition: Improper/Lack of Maintenance
Due 20 March 2003
Resolved 21 March 2003
Resolution: fax documentation.
Electrical › Electric Supply System (service)
Issued 20 March 2003
Resolved
Place covers over batteries or battery terminals. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 27 March 2003
Resolved 12 November 2003
Resolution: SAT
Construction/Loadline › Structures
Issued 20 March 2003
Resolved
Provide an inspection port for the void space under your anchor space. LEGACY COMPONENT DESC: Manhole
Condition: Unknown
Due 20 April 2003
Resolved 12 November 2003
Resolution: COMPARTMENT FOAM FILLED.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 20 March 2003
Resolved
Provide an inspected Type B-I portable fire extinguisher. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 20 March 2003
Resolved 21 March 2003
Documentation › Certificates/Documents
Issued 20 March 2003
Resolved
Provide an updated Certificate of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Improper/Lack of Maintenance
Due 27 March 2003
Resolved 12 November 2003
Resolution: SAT
Documentation › Certificates/Documents
Issued 20 March 2003
Resolved
Provide an FCC radiotelephone Safety Certificate. LEGACY COMPONENT DESC: FCC SSL
Condition: Improper/Lack of Maintenance
Due 27 March 2003
Resolved 12 November 2003
Resolution: RE-ISSUED.
Operations/Management › Drug and Alcohol Testing
Issued 19 March 2002
Resolved
PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE, PROVE ENROLLMENT OF ALL MARINE CREW MEMBERS IN A APPROVED CHEMICAL TESTING PROGRAM TO INCLUDE: PROOF OF CREW TRAINING, PRE-EMPLOYMENT TESTING, RANDOM SAMPLE TESTING, SERIOUS MARINE INCIDENT TESTING, REASONABLE CAUSE TESTING, EMPLOYEE CONSENT FORM. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2002
Resolved 26 April 2002
Resolution: ASAP PROGRAMS
Navigation › Piloting/Steering
Issued 19 March 2002
Resolved
PROVIDE COAST PILOT, LIGHT LIST, AND NAVIGATION RULES.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 April 2002
Resolved 26 April 2002
Resolution: SAT
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 19 March 2002
Resolved
ENSURE GENERATOR AUTOMATICALLY SHUTS DOWN INTEGRAL WITH FIXED FIRE FIGHTING SYSTEM. LEGACY COMPONENT DESC: Operating Controls
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 April 2002
Resolved 26 April 2002
Resolution: TEST SAT
Fire Fighting › Ventilation Systems
Issued 19 March 2002
Resolved
INSTALL VENT CLOSURES ON EACH ENGINE ROOM VENT.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2002
Resolved 26 April 2002
Resolution: CANVAS COVERS.
Fire Fighting › Miscellaneous Items
Issued 19 March 2002
Resolved
INSTALL 2 ADDITIONAL FIRE BUCKETS WITH LANYARDS. LEGACY COMPONENT DESC: Fire Buckets
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2002
Resolution: SAT
Lifesaving
Issued 8 May 2001
Resolved
Provide three (03) red flares to total 6 red/6 orange flares prior to carrying passengers.
Condition: Unknown
Due 15 May 2001
Resolved 19 March 2002
Lifesaving
Issued 8 May 2001
Resolved
Attach waterlight to lifering with corrosion resistant clip and 3-6 feet ofline.
Condition: Unknown
Due 8 June 2001
Resolved 19 March 2002
Documentation
Issued 8 May 2001
Resolved
Provide NOAA registration for EPIRB
Condition: Unknown
Due 8 June 2001
Resolved 19 March 2003
Accommodation/Occupational Safety
Issued 15 February 2000
Resolved
INSTALL RAILINGS ACCROSS THE TRANSOM OF THE VESSEL TO ENSURE A RAIL HEIGHT OF 30 INCHES THROUGHOUT THE PASSENGER ACCESSIBLE AREAS OF THE VESSEL. CURRENT TRANSOM RAIL HEIGHT IS BELOW 23 INCHES. INSTALLATION TO BE MADE BYNEXT DRYDOCK, BUT NO LATER THAN 24JUN00.
Condition: Unknown
Due 15 February 2000
Resolved 15 February 2000
Documentation
Issued 15 February 2000
Resolved
PROVIDE PASSENGER COUNT INFORMATION AT A SHORE SIDE LOCATION ACCESSABLE AT ALL TIMES SHOULD THE VESSEL BE OVERDUE OR FOUND WRECKED. THIS MAY BE PLACED IN A TUBE ON THE PIER OR KEPT WITH SOMEBODY WHO IS ACCESSABLE AROUNDTHE CLOCK IF NEED BE.
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Fire Fighting
Issued 15 February 2000
Resolved
SERVICE FIXED FIRE FIGHTING SYSTEM OR PROVE IT HAS BEEN INSTALLED OR SERVICED WITHIN THE PAST 12 MONTHS.
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Lifesaving
Issued 15 February 2000
Resolved
PROVIDE 3 ADDITIONAL RED HAND & 6 ORANGE SMOKE FLARES.
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Documentation
Issued 15 February 2000
Resolved
PROVIDE/POST AN EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Lifesaving
Issued 1 April 1999
Resolved
PROVIDE 1 ADDITIONAL ADULT LIFEJACKET PRIOR TO OPERATING ON LIMITED COASTWISE ROUTE W TOTAL OF 14 PERSONS.
Condition: Unknown
Due 1 April 1999
Resolved 1 April 1999
Documentation
Issued 1 April 1999
Resolved
PROVIDE WRITTEN TRAINING PROGRAM AND LOG DRILLS IAW 46CFR185.420
Condition: Unknown
Due 1 April 1999
Resolved 1 April 1999
Documentation
Issued 1 April 1999
Resolved
PROVIDE PROOF OF PAYMENT OF USER FEE FOR 1999-2000
Condition: Unknown
Due 1 August 1999
Resolved 1 August 1999
Engineering
Issued 1 April 1999
Resolved
INSTALL DOUBLE CLAMP ON WATER HOSE FROM BOOSTER IWO HEAT EXCHANGER ON MDE
Condition: Unknown
Due 1 April 1999
Resolved 1 April 1999
Documentation
Issued 1 April 1999
Resolved
PROVIDE EMPLOYER RUN DRUG TESTING PROGRAM IN WRITING IAW 46CFR16.
Condition: Unknown
Due 1 April 1999
Resolved 1 April 1999
Fire Fighting
Issued 1 April 1999
Resolved
PROVIDE AND INSTALL SMOKE DETECTOR IN OVERNIGHT ACCOMMODATION SPACE IAW 46CFR181.450
Condition: Unknown
Due 1 April 1999
Resolved 1 April 1999
Engineering
Issued 1 April 1999
Resolved
PROVE PROPER OPERATION OF AUTOMATIC ENGINE SHUTDOWN
Condition: Unknown
Due 1 April 1999
Resolved 1 April 1999
Engineering
Issued 1 April 1999
Resolved
INSTALL DOUBLE CLAMP ON PORTSIDE AFT FUEL TANK FLEXIBLE HOSE IWO TANK TOP
Condition: Unknown
Due 1 April 1999
Resolved 1 April 1999
Construction/Loadline
Issued 24 June 1998
Resolved
REPLACE CORRODED THRUOGH HULL FASTENERS FOR BAIT WELL SCREEN.
Condition: Unknown
Due 26 October 1998
Resolved 26 October 1998
Construction/Loadline
Issued 24 June 1998
Resolved
REPLACE DAMAGED A/C COOLING WATER INTAKE VALVE.
Condition: Unknown
Due 26 October 1998
Resolved 26 October 1998
Construction/Loadline
Issued 24 June 1998
Resolved
CAP AND PLUG UNUSED TRANSDUCER THROUGH HULL PENETRATIONS OR PROVIDE PERMANENT FRP CLOSURE PLANS AND SCHEDULE CG INSPECTION OF FRP REPAIRS.
Condition: Unknown
Due 26 October 1998
Resolved 26 October 1998
Documentation
Issued 10 February 1997
Resolved
PROVIDE DOCUMENTATION ON RANDOM DRUG TESTING EMPLOYEE ASSISTANCE PROGRAM (EAP) AND MIS INFORMATION.
Condition: Unknown
Due 18 February 1997
Resolved 25 February 1997
Lifesaving
Issued 10 February 1997
Resolved
REPAINT AND INSTALL REFLECTIVE MATERIAL ON LIFE FLOAT AND LIFE RING BUOY.
Condition: Unknown
Due 10 February 1997
Resolved 10 February 1997
Lifesaving
Issued 10 February 1997
Resolved
PROVIDE THREE (3) ORANGE SMOKE DAY SIGNALS.
Condition: Unknown
Due 18 February 1997
Resolved 25 February 1997
Lifesaving
Issued 10 February 1997
Resolved
PROVIDE THREE (3) LIGHTS FOR ADULT LIFE PRESERVERS.
Condition: Unknown
Due 18 February 1997
Resolved 25 February 1997
Fire Fighting
Issued 10 February 1997
Resolved
PROVIDE ONE (1) B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 18 February 1997
Resolved 25 February 1997
Fire Fighting
Issued 10 February 1997
Resolved
PROVIDE AND STENCIL THREE (3) 2.5 GALLON FIRE BUCKETS.
Condition: Unknown
Due 18 February 1997
Resolved 25 February 1997
Lifesaving
Issued 10 February 1997
Resolved
PROVIDE ONE (1) ADULT LIFE PRESERVER. PASSENGER CAPACITY REDUCED TO 11 UNTIL LIFE PRESERVER PROVIDED.
Condition: Unknown
Due 18 February 1997
Resolved 25 February 1997
Fire Fighting
Issued 20 April 1995
Resolved
Install fixed halon remote release operable from the steering station.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Engineering
Issued 7 February 1994
Resolved
Renew both fuel tank vents with a minimum 5/8 inch vent.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Engineering
Issued 7 February 1994
Resolved
Increase fuel tank vent for 2 fuel tanks on 1-vent.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Lifesaving
Issued 31 August 1993
Resolved
RENEW 3 ORANGE FLARES._x001C_
Condition: Unknown
Due 31 August 1993
Resolved 31 August 1993
Fire Fighting
Issued 31 August 1993
Resolved
SERVICE OR RENEW 1 B-I FIRE EXTINGUISHER._x001C_
Condition: Unknown
Due 31 August 1993
Resolved 31 August 1993
Electrical
Issued 31 August 1993
Resolved
REMOVE WIRE NUTS 5 LOCATIONS IN ENG. AND STEERING COMPARTMENTS.
Condition: Unknown
Due 31 August 1993
Resolved 31 August 1993
Documentation
Issued 31 August 1993
Resolved
RENEW DOCUMENT, RADIO STATION LICENSE AND RADIO OPERATOR'S LICENSE.
Condition: Unknown
Due 31 August 1993
Resolved 31 August 1993
Navigation
Issued 31 August 1993
Resolved
REPAIR EMERGENCY STEERING TILLER.
Condition: Unknown
Due 31 August 1993
Resolved 31 August 1993
Construction/Loadline
Issued 31 August 1993
Resolved
DOUBLE HOSE CLAMP 3 THRU HULL CONNECTIONS.
Condition: Unknown
Due 31 August 1993
Resolved 31 August 1993
Lifesaving
Issued 8 July 1992
Resolved
Provide 406MHZ EPIRB or class A manufactured after 1OCT88. Vessel restricted to coastwise service not more than 20 miles until this requirement is satisfied.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Engineering
Issued 28 August 1991
Resolved
MAKE PROPER REPAIR TO 2 FUEL LEAKS AT ENGINE ROOM BULKHEAD JUST FORWARD OF MAIN ENGINE TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Documentation
Issued 20 June 1991
Resolved
POST COI, FCC RADIOTELEPHONY CERTIFICATES.
Condition: Unknown
Due 12 July 1991
Resolved 12 July 1991
Fire Fighting
Issued 20 June 1991
Resolved
SERVICE HALON SYS IN ENGINE ROOM.
Condition: Unknown
Due 12 July 1991
Resolved 12 July 1991
Lifesaving
Issued 20 June 1991
Resolved
REPAIR LIGHTS ON RING BUOY AND LIFEFLOAT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 12 July 1991
Resolved 12 July 1991
Lifesaving
Issued 20 June 1991
Resolved
REPAIR/REPLACE EPIRB PRIOR TO EXCEEDING 20 MILES FROM LAND.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Lifesaving
Issued 20 June 1991
Resolved
REPLACE 1 LIFE FLOAT PADDLE, STENCIL BOTH AND LASH BOTH TO FLOAT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 12 July 1991
Resolved 12 July 1991
Lifesaving
Issued 20 June 1991
Resolved
REPLACE 5 PFD LIGHTS PRIOR TO EXCEEDING 20 MILES FROM LAND.
Condition: Unknown
Due 12 July 1991
Resolved 12 July 1991
Lifesaving
Issued 20 June 1991
Resolved
PROVIDE 6 RED & 6 ORANGE FLARES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 12 July 1991
Resolved 12 July 1991
Navigation
Issued 20 June 1991
Resolved
REPAIR PORT RUNNING LIGHT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 12 July 1991
Resolved 12 July 1991
Engineering
Issued 20 June 1991
Resolved
DOUBLE CLAMP FUEL TANK VENT HOSES.
Condition: Unknown
Due 12 July 1991
Resolved 12 July 1991
Navigation
Issued 20 June 1991
Resolved
PROVIDE WRENCH FOR TILLER ACCESS PLATE.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Construction/Loadline
Issued 20 June 1991
Resolved
PROVIDE ADEQUATE PORTABLE BILGE PUMP HOSE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Documentation
Issued 22 February 1990
Resolved
CREDIT DRYDOCK DUE 22AUG91. PLEASE CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Engineering
Issued 22 February 1990
Resolved
PROVIDE REMOTE FUEL SHUTOFFS FOR FUEL TANK SUCTIONS, OPERABLE FROM OUTSIDE TANK SPACE (WEATHERDECK).
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Lifesaving
Issued 22 February 1990
Resolved
PROVIDE 60' LINE ON RINGBUOY.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Navigation
Issued 22 February 1990
Resolved
RELOCATE EPIRB FLOATFREE.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Documentation
Issued 22 February 1990
Resolved
PROVIDE A VALID FCC RADIOTELEPHONY CERTFICATE. MAKE APPLICATION FOR THIS CERTIFICATE IMMEDIATELY.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Lifesaving
Issued 22 February 1990
Resolved
PROVIDE 1 NEW LIFEFLOAT PADDLE.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Lifesaving
Issued 22 February 1990
Resolved
STENCIL LIFEFLOAT "12 PERSON CAPACITY".
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Lifesaving
Issued 22 February 1990
Resolved
RELOCATE LIFEFLOAT LIGHT TO OFF OF RAFT.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Electrical
Issued 22 February 1990
Resolved
DEMONSTRATE OPERATION OF GENERATOR.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Navigation
Issued 22 February 1990
Resolved
DEMONSTRATE SSB OPERATION AFTER MOVING SSB TO HELM PRIOR TO OCEANS OPERATIONS.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Lifesaving
Issued 22 February 1990
Resolved
PROVIDE 1 ADDITIONAL ADULT PFD WITH LIGHT PRIOR TO CARRYING 10 PASSENGERS OCEANS.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990
Lifesaving
Issued 22 February 1990
Resolved
PROVIDE 1 ADDITIONAL PFD LIGHT PRIOR TO CARRYING 12 PASSENGERS COASTWISE.
Condition: Unknown
Due 22 February 1990
Resolved 22 February 1990