MAURY USCG vessel records Sign in
← All vessels

TASSOS N

TASSOS N is a 1986 freight ship. The Coast Guard has recorded 27 inspections since 1987, most recently in June 2008, along with 23 deficiencies and 1 operational control.

Records from 1987 to 2008. Most recent: inspection, 7 June 2008.

Built
1986
Last inspected
7 June 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8412778 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
280706
Flag
PHILIPPINES
—
Maury page id
psix-280706

Inspections, by type

…with no type recorded17
Years with a record 17 calendar years (1987–2008)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it23624 - Convention (Subpart B), Gross Ton
23624 - Regulatory (Subpart C or D), Gross Ton
13532 - Convention (Subpart B), Net Ton
50168 - Displacement, Ton
41351 - Dead Weight, Ton
13532 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

7 June 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3229602
3 June 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3226630
27 February 2008 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3154820
6 April 2007 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2902893
14 March 2007 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2888138
25 October 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2807859
4 November 2005 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2527838
4 October 2005 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2507275
25 May 2005 Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2367251
20 May 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2363444
19 November 2004 PII Safety Exam · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2244202
1 September 2004 ISPS II Exam
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2183061
10 May 2004 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2064285
6 May 2003 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1787426
8 March 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 287519
9 August 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 280974
9 February 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 400115
13 November 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 397259
11 April 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 390058
31 January 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 729240
12 January 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 374833
20 March 1994 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 365474
1 April 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 490783
16 June 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 351473
8 May 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 343569
27 November 1989 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 333936
14 May 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 315982

Deficiency record · 23

Navigation › Piloting/Steering › Gyro Compass
Issued 7 June 2008 Resolved
The Master of the vessel reported that it has a malfunctioning Gyro Compass
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2008
Resolution: Received technician report stating the gyro compass is now in good working order.
Engineering › Bilge Water Management System › Pump
Issued 27 February 2008 Resolved
Gland packing on Fire/Ballast/Bilge pump leaked excessively when pump was energized. Replace packing and test pump ot the satisfaction of the a Coasrt Guard Marine Inspector prior to next U.S. port.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 28 February 2008
Resolution: Inspector found new packing on fire pump to be working properly under pressure
Fire Fighting › Fire Main › Condition
Issued 25 October 2006 Resolved
SMALL HOLE IN DISCHARGE PIPE ON FIREMAIN
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 October 2006
Fire Fighting › Fire Main › Condition
Issued 25 October 2006 Resolved
EXPOSED BELT ON EMERNGENCY FIRE PUMP
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 October 2006
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 25 October 2006 Resolved
SOFT PATCH ON GRAY WATER DISCHARGE PIPING NEEDS TO BE PERMENENT.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 October 2006
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 19 November 2004 Resolved
Three toilets did not flush or drain. Cite: ILO 147: Sanitary Facilities; 21 (f).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2004
Resolution: Toilets were fixed prior to the end of the boarding.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 19 November 2004 Resolved
Bunker line on main deck not pressure tested since August 2002. Must be pressure tested annually in U. S. Conduct required pressure test to 1.5 x the Maximum Allowable Working Pressure (MAWP) prior to bunkering in U.S. waters. Cite: 33 CFR 156.170 (c)(4)(e)(f)(3).
Condition: Placed in Improper Service
Action required: 703 - Prior to bunkering operations
Resolved 19 November 2004
Resolution: Received stamped and signed statement from Chief Engineer that the required pressure test was conducted.
Fire Fighting
Issued 9 August 2000 Resolved
PRIOR TO DEPARTURE DEMONSTRATE SATISFACTORY FIRE DRILL.
Condition: Unknown
Due 9 August 2000
Resolved 10 August 2000
Engineering
Issued 13 November 1996 Resolved
PRIOR TO DEPARTURE REMOVE ALL DEBRIS FROM CONTAINMENT AREAS.
Condition: Unknown
Due 13 November 1996
Resolved 14 November 1996
Fire Fighting
Issued 13 November 1996 Resolved
PRIOR TO 13DEC96 REPAIR 2 HOLES IN FIREMAIN LOCATED AT PORT SIDE #3 CARGO HOLD EXPANSION JOINT AND BETWEEN HOLDS #1 AND #2 AT FIREMAIN DRAIN.
Condition: Unknown
Due 1 March 1997
Resolved 1 March 1997
Fire Fighting
Issued 13 November 1996 Resolved
PRIOR TO 13DEC96 REPAIR INOPERATIVE FIRE DAMPER LOCATED 02 DECK AFT. (VENTILATES HALL WAY)
Condition: Unknown
Due 1 March 1997
Resolved 1 March 1997
Lifesaving
Issued 13 November 1996 Resolved
PRIOR TO DEPARTURE REPLACE/REPAIR INOPERATIVE PORT AND STARBOARD BRIDGE WING SMOKE/LIGHT LIFE-RING.
Condition: Unknown
Due 14 November 1996
Resolved 14 November 1996
Construction/Loadline
Issued 13 November 1996 Resolved
PRIOR TO 13DEC96 REPAIR HYDRAULIC LEAK ON CARGO HOLD #2 HATCH RAM.
Condition: Unknown
Due 1 March 1997
Resolved 1 March 1997
Navigation
Issued 12 January 1995 Resolved
WHEN INSPECTED BY THE BOARDING OFFICERS IT WAS NOTED THAT THE VESSEL TRANSITED PUGET SOUND WITH AREA CHARTS #18471, #18441, #18448 AND #18440 UNCORRECTED.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Navigation
Issued 12 January 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Navigation
Issued 12 January 1995 Resolved
VESSEL DID NOT HAVE CHANNEL 5A CAPABILITY WHILE TRANSITING PUGET SOUND
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Navigation
Issued 12 January 1995 Resolved
VESSELS SECOND RADAR WAS INOP. VESSEL OVER 10000 GT AND REQUIRED TO HAVE TWO PROPERLY OPERATING RADARS.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Navigation
Issued 20 March 1994 Resolved
VESSEL IS MISSING INLAND NAVIGATION RULES, IN ACCORDANCE WITH 33 CFR 88.05
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Navigation
Issued 27 November 1989 Resolved
APPROACH CHART FOR AREA TRANSITTED NOT CURRENT OR CURRENTLY CORRECTED AS PER 33 CFR 164.33(A)(II)
Condition: Unknown
Due 27 November 1989
Resolved 27 November 1989
Documentation
Issued 27 November 1989 Resolved
DECLARATION OF INSPECTION NOT ONBOARD AS PER 33CFR155.820(D)
Condition: Unknown
Due 27 November 1989
Resolved 27 November 1989
Navigation
Issued 14 May 1987 Resolved
VESSEL TRANSITED THE COLUMBIA RIVER TO PORTLAND, OREGON, WITH CHARTS OF THEAREA NAVIGATED NOT CURRENTLY CORRECTED UP TO DATE AS REQUIRED.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Navigation
Issued 14 May 1987 Resolved
VESSEL TRANSITED THE COLUMBIA RIVER TO PORTLAND, OREGON, WITH A LIGHT LIST OF THE AREA NAVIGATED NOT CURRENTLY CORRECTED UP TO DATE AS REQUIRED.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Navigation
Issued 14 May 1987 Resolved
VESSEL TRANSITED THE COLUMBIA RIVER TO PORTLAND, OREGON, WITH A COAST PILOTOF THE AREA NAVIGATED NOT CURRENTLY CORRECTED UP TO DATE AS REQUIRED.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.